d-alpha tocopherol has been researched along with Prosthesis Durability in 64 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 1 (1.56) | 18.2507 |
2000's | 1 (1.56) | 29.6817 |
2010's | 34 (53.13) | 24.3611 |
2020's | 28 (43.75) | 2.80 |
Authors | Studies |
---|---|
Malhi, AS; Muratoglu, OK; Oral, E; Wannomae, KK | 1 |
Christensen, SD; Micheli, BR; Muratoglu, OK; Rowell, SL; Schroeder, DW; Wannomae, KK | 1 |
Do, MU; Kim, KB; Lee, SM; Moon, NH; Shin, WC | 1 |
Amsler, F; Hart, A; Henckel, J; Hirschmann, MT; Hothi, H; Mathis, DT; Schmidli, J | 1 |
Buhagiar, J; Dalli, D; Mollicone, P; Schembri Wismayer, P | 1 |
Bergvinsson, H; Flivik, G; Sundberg, M; Tjörnstrand, J; Zampelis, V | 1 |
Alhasan, H; Aly, MK; Ebata, T; Iwasaki, N; Kida, H; Matsumae, G; Shimizu, T; Takahashi, D; Terkawi, MA; Uetsuki, K; Yokota, S; Yutani, T | 1 |
Ding, M; Kjærgaard, K; Overgaard, S; Varnum, C | 1 |
Deckard, ER; Meneghini, E; Meneghini, RM; Miller, B; Nielson, T; Owens, G | 1 |
Adams, JB; Berend, KR; Byrd, ZO; Crawford, DA; Lombardi, AV; Morris, MJ | 1 |
Affatato, S; Pezzotti, G; Shishido, T; Takahashi, Y; Tateiwa, T; Yamamoto, K | 1 |
Kurtz, SM; Spece, H; Yarbrough, RV | 1 |
Bedair, HS; Blackburn, AZ; Collins, AK; Feder, OI; Melnic, CM; Nepple, CM; Prasad, AK; Sauder, N | 1 |
Ishida, T; Matsuoka, T; Shishido, T; Takahashi, Y; Tateiwa, T; Yamamoto, K | 1 |
Ding, M; El-Sahoury, JAN; Hofbauer, C; Kjærgaard, K; Overgaard, S; Ovesen, O | 1 |
Hasegawa, M; Naito, Y; Sudo, A; Tone, S; Wakabayashi, H | 1 |
Klein, GR; Kurtz, SM; Lee, GC; MacDonald, DW; Mont, MA; Schachtner, JT; Spece, H | 1 |
Bodén, H; Chammout, G; Eisler, T; Mukka, SS; Rysinska, AD; Salemyr, M; Sköldenberg, OG | 1 |
Busch, A; Haversath, M; Jäger, M; Wegner, A | 1 |
Kamada, K; Masaoka, T; Pezzotti, G; Shishido, T; Takahashi, Y; Tateiwa, T; Yamamoto, K | 1 |
Baghdadi, J; Busch, A; Flörkemeier, T; Grupp, TM; Haversath, M; Hütter, F; Jäger, M; Klebingat, S | 1 |
Gast, A; Massier, JRA; Snijders, TE; Van Erp, JHJ | 1 |
Andreasen, CM; Bragdon, C; Ding, M; Hofbauer, C; Jensen, C; Kjærgaard, K; Malchau, H; Overgaard, S; Ovesen, O | 1 |
Gromov, K; Husted, H; Kallemose, T; Malchau, H; Sillesen, NH; Troelsen, A | 1 |
Nordsletten, L; Pripp, AH; Röhrl, SM; Thoen, PS | 1 |
Bourroux, E; Buia, G; Chapus, V; Dunet, J; Feron, M; Hulet, C; Praz, C; Remazeilles, M; Rochcongar, G | 1 |
Beck, M; Becker, R; Comtesse, S; de Gast, A; Dominkus, M; French, G; Helmy, N; Rehbein, P | 1 |
Ftaita, S; Thienpont, E; Vanden Berghe, A | 1 |
Afghanyar, Y; Dargel, J; Drees, P; Joser, S; Kutzner, KP; Rehbein, P; Tecle, J | 1 |
Baines, J; Beck, M; Becker, R; de Gast, A; Dominkus, M; French, GJ; Helmy, N; Hollmann, L; Mahmood, FF; Rehbein, P | 1 |
Eskelinen, A; Haapakoski, J; Hemmilä, M; Kettunen, J; Laaksonen, I; Mäkelä, KT; Matilainen, M; Pamilo, K; Puhto, AP | 1 |
Greene, ME; Laursen, MB; Malchau, H; Nebergall, AK; Nielsen, PT; Troelsen, A | 1 |
Johanson, PE; Kärrholm, J; Shareghi, B | 2 |
Bourroux, E; Buia, G; Chapus, V; Dunet, J; Hulet, C; Rochcongar, G | 1 |
Bulstra, SK; Lambert, B; Neut, D; van der Veen, HC | 1 |
Alexander, JJ; Bell, SN; Coghlan, J; Dallmann, F; Lerf, R | 1 |
Gul, RM; Li, ZM; Ren, Y; Wang, FY; Wang, J; Wei, ST; Wei, X; Xu, JZ; Xu, L | 1 |
Akase, H; Kaku, N; Kataoka, M; Tabata, T; Tagomori, H; Tsumura, H | 1 |
Beswick, AD; Foxall-Smi, M; Kunutsor, SK; Roberton, A; Whitehouse, MR; Wyatt, MC | 1 |
Bragdon, C; Galea, VP; Laursen, M; Malchau, H; Muratoglu, OK; Rojanasopondist, P | 2 |
Ahl, T; Bodén, H; Chammout, G; Muren, O; Salemyr, M; Sköldenberg, O; Stark, A | 1 |
Greene, ME; Laursen, MB; Malchau, H; Nebergall, AK; Nielsen, PT; Sillesen, NH; Troelsen, A | 1 |
Bragdon, C; Dion, NT; Freiberg, AA; Muratoglu, O | 1 |
Lovro, LR; Meneghini, RM; Wallace, JM; Ziemba-Davis, M | 2 |
Greene, ME; Malchau, H; Nebergall, AK; Rolfson, O; Rubash, HE; Troelsen, A | 1 |
Kubo, K; Masaoka, T; Shishido, T; Takahashi, Y; Tateiwa, T; Yamamoto, K | 1 |
Masaoka, T; Pezzotti, G; Shishido, T; Takahashi, Y; Tateiwa, T; Yamamoto, K | 1 |
Bodén, H; Chammout, G; Eisler, T; Muren, O; Rysinska, A; Salemyr, M; Sköldenberg, O | 1 |
Achour, S; Massin, P | 1 |
Kaddick, C; Kretzer, JP | 1 |
Affatato, S; Bracco, P; De Mattia, JS; Pavoni, E; Taddei, P | 1 |
Adams, JB; Berend, KR; Flament, EM; Hurst, JM; Lombardi, AV; Morris, MJ | 1 |
Anract, P; Babinet, A; Courpied, JP; Dumaine, V; Hamadouche, M; Scemama, C | 1 |
Beck, M; Pfluger, D; Weidner, J; Wyatt, M | 1 |
Cofske, J; Jarrett, BT; Malchau, H; Muratoglu, O; Oral, E; Rosenberg, AE | 1 |
Muratoglu, OK; Oral, E | 1 |
Alvarez, E; Bruce, DA; DesJardins, JD; Vaidya, C; Vinciguerra, J | 1 |
Allizond, V; Banche, G; Bistolfi, A; Boffano, M; Bracco, P; Cimino, A; Costa, L; Cuffini, AM; Del Prever, EM | 1 |
Doshi, B; Fung, M; Lyons, C; Muratoglu, OK; Neils, AL; Oral, E | 1 |
Bulstra, SK; van den Akker-Scheek, I; van der Veen, HC; van Raay, JJ | 1 |
Aoyama, E; Ikada, Y; Kitakura, T; Onmori, N; Tomita, N | 1 |
6 review(s) available for d-alpha tocopherol and Prosthesis Durability
Article | Year |
---|---|
In Vivo Performance of Vitamin E Stabilized Polyethylene Implants for Total Hip Arthroplasty: A Review.
Topics: Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E | 2023 |
Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature.
Topics: Antioxidants; Arthroplasty, Replacement; Biocompatible Materials; Humans; Immunity; Infections; Joint Prosthesis; Materials Testing; Osteolysis; Oxidative Stress; Polyethylenes; Prosthesis Design; Prosthesis Failure; Prosthesis-Related Infections; Vitamin E | 2019 |
Does vitamin E highly-crosslinked polyethylene convey an advantage in primary total hip replacement? A systematic review and meta-analysis.
Topics: Arthroplasty, Replacement, Hip; Femur Head; Hip Prosthesis; Humans; Polyethylene; Polyethylenes; Prosthesis Design; Prosthesis Failure; Vitamin E | 2020 |
Durability of highly cross-linked polyethylene in total hip and total knee arthroplasty.
Topics: Arthroplasty, Replacement, Hip; Arthroplasty, Replacement, Knee; Compressive Strength; Cross-Linking Reagents; Female; Hip Prosthesis; Humans; Knee Prosthesis; Male; Polyethylene; Prosthesis Design; Prosthesis Failure; Randomized Controlled Trials as Topic; Sensitivity and Specificity; Vitamin E | 2015 |
Wear products of total hip arthroplasty: The case of polyethylene.
Topics: Antioxidants; Arthroplasty, Replacement, Hip; Ceramics; Hip Prosthesis; Humans; Materials Testing; Molecular Weight; Osteolysis; Oxidation-Reduction; Polyethylenes; Prosthesis Design; Prosthesis Failure; Vitamin E | 2017 |
Vitamin E diffused, highly crosslinked UHMWPE: a review.
Topics: Animals; Antioxidants; Arthroplasty, Replacement, Hip; Cross-Linking Reagents; Diffusion; Dogs; Hip Prosthesis; Humans; In Vitro Techniques; Materials Testing; Osseointegration; Osteolysis; Oxidation-Reduction; Polyethylenes; Prosthesis Failure; Rabbits; Spectrophotometry, Infrared; Vitamin E | 2011 |
18 trial(s) available for d-alpha tocopherol and Prosthesis Durability
Article | Year |
---|---|
Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up.
Topics: Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Vitamin E | 2022 |
Vitamin E-diffused liners show less head penetration than cross-linked polyethylene liners in total hip arthroplasty: a ten-year multi-arm randomized trial.
Topics: Aged; Arthroplasty, Replacement, Hip; Female; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E | 2023 |
A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty.
Topics: Age Factors; Aged; Arthroplasty, Replacement, Hip; Double-Blind Method; Female; Foreign-Body Migration; Hip Prosthesis; Humans; Incidence; Male; Middle Aged; Osteoarthritis, Hip; Polyethylenes; Prognosis; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Risk Assessment; Severity of Illness Index; Sex Factors; Statistics, Nonparametric; Sweden; Vitamin E | 2019 |
Vitamin E-blended versus conventional polyethylene liners in prostheses : Prospective, randomized trial with 3-year follow-up.
Topics: Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Vitamin E | 2020 |
Vitamin E-blended highly cross-linked polyethylene liners in total hip arthroplasty: a randomized, multicenter trial using virtual CAD-based wear analysis at 5-year follow-up.
Topics: Acetabulum; Adult; Aged; Antioxidants; Arthroplasty, Replacement, Hip; Computer-Aided Design; Female; Follow-Up Studies; Germany; Hip Joint; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Polyethylenes; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiography; Vitamin E | 2020 |
A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Female; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Osteolysis; Outcome Assessment, Health Care; Polyethylene; Polyethylenes; Postoperative Complications; Prosthesis Design; Prosthesis Failure; Radiography; Vitamin E | 2020 |
Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.
Topics: Aged; Arthroplasty, Replacement, Hip; Female; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylene; Prosthesis Failure; Surveys and Questionnaires; Vitamin E | 2020 |
Results of a randomized controlled trial with five-year radiostereometric analysis results of vitamin E-infused highly crosslinked versus moderately crosslinked polyethylene in reverse total hip arthroplasty.
Topics: Acetabulum; Adult; Aged; Aged, 80 and over; Arthroplasty, Replacement, Hip; Biocompatible Materials; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Vitamin E | 2020 |
Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial.
Topics: Aged; Arthroplasty, Replacement, Hip; Female; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylene; Polyethylenes; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Vitamin E | 2021 |
Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis.
Topics: Adult; Aged; Arthroplasty, Replacement, Hip; Double-Blind Method; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Materials Testing; Middle Aged; Osteoarthritis, Hip; Patient Reported Outcome Measures; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Vitamin E | 2017 |
Wear of Vitamin E-Infused Highly Cross-Linked Polyethylene at Five Years.
Topics: Adult; Aged; Antioxidants; Arthroplasty, Replacement, Hip; Female; Femur; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Polyethylene; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Time Factors; Vitamin E; Young Adult | 2017 |
Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty: A Prospective Randomized Controlled Trial.
Topics: Adult; Aged; Arthroplasty, Replacement, Hip; Biomechanical Phenomena; Cross-Linking Reagents; Female; Hip Prosthesis; Humans; Male; Middle Aged; Molecular Weight; Osteolysis; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Vitamin E | 2018 |
Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis.
Topics: Adult; Aged; Arthroplasty, Replacement, Hip; Double-Blind Method; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Patient Reported Outcome Measures; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Titanium; Vitamin E | 2019 |
Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial.
Topics: Adult; Aged; Antioxidants; Arthroplasty, Replacement, Hip; Female; Femur Head; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Polyethylene; Prospective Studies; Prosthesis Failure; Radiostereometric Analysis; Vitamin E | 2015 |
Femoral Head Penetration of Vitamin E-Infused Highly Cross-Linked Polyethylene Liners: A Randomized Radiostereometric Study of Seventy Hips Followed for Two Years.
Topics: Aged; Arthroplasty, Replacement, Hip; Female; Femur Head; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Pain Measurement; Polyethylenes; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Range of Motion, Articular; Recovery of Function; Risk Assessment; Severity of Illness Index; Statistics, Nonparametric; Time Factors; Vitamin E | 2015 |
Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP).
Topics: Aged; Arthroplasty, Replacement, Hip; Double-Blind Method; Female; Hip Prosthesis; Humans; Longitudinal Studies; Male; Middle Aged; Osteoarthritis, Hip; Polyethylene; Prosthesis Failure; Radiostereometric Analysis; Regression Analysis; Treatment Outcome; Vitamin E | 2016 |
Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.
Topics: Acetabulum; Adult; Aged; Arthroplasty, Replacement, Hip; Female; Femur Head; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Osteolysis; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E | 2017 |
Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial.
Topics: Arthroplasty, Replacement, Hip; Bone Density; Double-Blind Method; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prosthesis Failure; Recovery of Function; Survival Rate; Treatment Outcome; Vitamin E | 2012 |
40 other study(ies) available for d-alpha tocopherol and Prosthesis Durability
Article | Year |
---|---|
Highly cross-linked ultrahigh molecular weight polyethylene with improved fatigue resistance for total joint arthroplasty: recipient of the 2006 Hap Paul Award.
Topics: alpha-Tocopherol; Biocompatible Materials; Biomechanical Phenomena; Materials Testing; Polyethylenes; Prosthesis Failure | 2008 |
Delamination and adhesive wear behavior of alpha-tocopherol-stabilized irradiated ultrahigh-molecular-weight polyethylene.
Topics: alpha-Tocopherol; Arthroplasty, Replacement, Knee; Biocompatible Materials; Equipment Failure Analysis; Knee Prosthesis; Materials Testing; Oxidation-Reduction; Polyethylenes; Prosthesis Design; Prosthesis Failure | 2010 |
Early unexpected failure of a vitamin E-infused highly cross-linked polyethylene liner: A case report.
Topics: Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Vitamin E | 2021 |
Comparative retrieval analysis of antioxidant polyethylene: bonding of vitamin-E does not reduce in-vivo surface damage.
Topics: Antioxidants; Arthroplasty, Replacement, Knee; Humans; Knee Prosthesis; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E; Vitamins | 2021 |
A novel hip joint prosthesis with uni-directional articulations for reduced wear.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Hip Joint; Hip Prosthesis; Humans; Materials Testing; Polyethylene; Polyethylenes; Prosthesis Design; Prosthesis Failure; Vitamin E | 2022 |
Determination of optimal concentration of vitamin E in polyethylene liners for producing minimal biological response to prosthetic wear debris.
Topics: Animals; Disease Models, Animal; Mice; Osteolysis; Polyethylene; Polyethylenes; Prosthesis Failure; Skull; Tumor Necrosis Factor-alpha; Vitamin E | 2022 |
Revision Risk of Total Hip Arthroplasty With Vitamin E Doped Liners: Results From the Danish Hip Arthroplasty Register.
Topics: Arthroplasty, Replacement, Hip; Denmark; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Vitamin E | 2022 |
Large Femoral Heads in Total Hip Arthroplasty With Vitamin E Highly Cross-Linked Polyethylene: Head Penetration Rates Compared to Highly Cross-Linked Polyethylene.
Topics: Arthroplasty, Replacement, Hip; Femur Head; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Vitamin E | 2022 |
Mid-Term Survival of Total Hip Arthroplasty in Patients Younger Than 55-year-old.
Topics: Arthroplasty, Replacement, Hip; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Periprosthetic Fractures; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Retrospective Studies; Treatment Outcome; Vitamin E | 2022 |
To what extent could the acetabular liner thickness be reduced yet remaining tribologically acceptable in metal-on-vitamin E-diffused crosslinked polyethylene hip arthroplasty?
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Metals; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E | 2022 |
Minimum 7-Year Follow-Up of Vitamin E-Diffused and Highly Cross-Linked Polyethylene Liners in Total Hip Arthroplasty: Findings From a Prospective, International, Multicenter Study of 977 Patients.
Topics: Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Vitamin E | 2023 |
In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty.
Topics: Arthroplasty, Replacement, Hip; Child; Follow-Up Studies; Hip Prosthesis; Humans; Osteolysis; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E; Vitamins | 2023 |
Minimum 7-year results of cementless total hip arthroplasty with vitamin E-diffused and 2-methacryloyloxyethyl phosphorylcholine-grafted highly cross-linked polyethylene.
Topics: Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Vitamin E | 2023 |
Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty.
Topics: Aged; Antioxidants; Arthroplasty, Replacement, Knee; Female; Humans; Knee Joint; Knee Prosthesis; Male; Middle Aged; Oxidation-Reduction; Polyethylene; Prosthesis Design; Prosthesis Failure; Spectroscopy, Fourier Transform Infrared; Vitamin E | 2019 |
Influence of liner offset and locking mechanism on fatigue durability in highly cross-linked polyethylene total hip prostheses.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Biocompatible Materials; Cross-Linking Reagents; Hip Prosthesis; Humans; Mechanical Phenomena; Metals; Polyethylenes; Prosthesis Design; Prosthesis Failure; Spectrum Analysis, Raman; Vitamin E | 2020 |
Safety of vitamin E-infused highwall liners for routine use in primary total hip arthroplasty: single centre, short-term follow-up of 1221 cases.
Topics: Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Vitamin E | 2022 |
Wear and migration are not influenced by head size in a vitamin E-infused highly cross-linked polyethylene acetabular cup.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Vitamin E | 2021 |
Vitamin E-enriched polyethylene bearings are not inferior to Arcom bearings in primary total knee arthroplasty at medium-term follow-up.
Topics: Arthroplasty, Replacement, Knee; Humans; Knee Prosthesis; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Retrospective Studies; Treatment Outcome; Vitamin E | 2021 |
The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Vitamin E | 2021 |
Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study.
Topics: Acetabulum; Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Patient Reported Outcome Measures; Prospective Studies; Prosthesis Design; Prosthesis Failure; Reoperation; Survivorship; Vitamin E | 2021 |
Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register.
Topics: Aged; Antioxidants; Arthroplasty, Replacement, Hip; Female; Finland; Hip Prosthesis; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Osteoarthritis, Hip; Polyethylene; Proportional Hazards Models; Prosthesis Design; Prosthesis Failure; Registries; Reoperation; Vitamin E | 2021 |
The effect of vitamin E-enhanced cross-linked polyethylene on wear in shoulder arthroplasty-a wear simulator study.
Topics: Antioxidants; Arthroplasty, Replacement, Shoulder; Glenoid Cavity; Humans; Humeral Head; Materials Testing; Polyethylene; Polyethylenes; Prosthesis Design; Prosthesis Failure; Shoulder Prosthesis; Vitamin E | 2019 |
High Oxidation Stability of Tea Polyphenol-stabilized Highly Crosslinked UHMWPE Under an in Vitro Aggressive Oxidative Condition.
Topics: Antioxidants; Camellia sinensis; Catechin; Free Radicals; Joint Prosthesis; Oxidation-Reduction; Plant Extracts; Polyethylenes; Prosthesis Failure; Squalene; Time Factors; Vitamin E | 2019 |
Efficacy of vitamin E for mechanical damage and oxidation of polyethylene rim by stem neck impingement.
Topics: Antioxidants; Arthroplasty, Replacement, Hip; Cross-Linking Reagents; Equipment Failure Analysis; Humans; Materials Testing; Polyethylenes; Prosthesis Failure; Surface Properties; Vitamin E | 2019 |
Infographic: Total hip arthroplasty component wear and stability.
Topics: Aged; Arthroplasty, Replacement, Hip; Follow-Up Studies; Hip Prosthesis; Humans; Osteoarthritis, Hip; Polyethylene; Prosthesis Design; Prosthesis Failure; Titanium; Treatment Outcome; Vitamin E | 2019 |
Three Year RSA Evaluation of Vitamin E Diffused Highly Cross-linked Polyethylene Liners and Cup Stability.
Topics: Acetabulum; Adult; Aged; Arthroplasty, Replacement, Hip; Ceramics; Chromium Alloys; Cobalt; Cross-Linking Reagents; Female; Femur Head; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Oxygen; Patient Safety; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Time Factors; Titanium; Vitamin E | 2015 |
Large Metal Heads and Vitamin E Polyethylene Increase Frictional Torque in Total Hip Arthroplasty.
Topics: Arthroplasty, Replacement, Hip; Ceramics; Chromium Alloys; Corrosion; Femur Head; Friction; Hip Prosthesis; Humans; Polyethylene; Prosthesis Design; Prosthesis Failure; Torque; Vitamin E | 2016 |
Five-Year Experience of Vitamin E-Diffused Highly Cross-Linked Polyethylene Wear in Total Hip Arthroplasty Assessed by Radiostereometric Analysis.
Topics: Adult; Aged; Arthroplasty, Replacement, Hip; Chromium Alloys; Female; Femur Head; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis; Oxygen; Polyethylene; Prospective Studies; Prosthesis Design; Prosthesis Failure; Radiostereometric Analysis; Self Report; Severity of Illness Index; Stress, Mechanical; Tantalum; Time Factors; Titanium; Treatment Outcome; Vitamin E | 2016 |
Size and thickness effect on creep behavior in conventional and vitamin E-diffused highly crosslinked polyethylene for total hip arthroplasty.
Topics: Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Polyethylenes; Prosthesis Design; Prosthesis Failure; Vitamin E | 2016 |
Improved Resistance to Neck-Liner Impingement in Second-Generation Highly Crosslinked Polyethylene-The Role of Vitamin E and Crosslinks.
Topics: Acetabulum; Hip Prosthesis; Humans; Materials Testing; Polyethylene; Polyethylenes; Prosthesis Design; Prosthesis Failure; Tensile Strength; Vitamin E | 2016 |
Response to Letter to the Editor on "Large Metal Heads and Vitamin E Polyethylene Increase Frictional Torque in Total Hip Arthroplasty".
Topics: Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Metals; Polyethylene; Prosthesis Design; Prosthesis Failure; Torque; Vitamin E | 2016 |
Letter to the Editor on "Large Metal Heads and Vitamin E Polyethylene Increase Frictional Torque in Total Hip Arthroplasty".
Topics: Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Metals; Polyethylene; Prosthesis Design; Prosthesis Failure; Torque; Vitamin E | 2016 |
Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test.
Topics: Acetabulum; Animals; Cattle; Hip Prosthesis; Materials Testing; Polyethylenes; Prosthesis Failure; Vitamin E | 2016 |
Early Experience with Vitamin E Antioxidant-Infused Highly Cross-Linked Polyethylene Inserts in Primary Total Knee Arthroplasty.
Topics: Antioxidants; Arthroplasty, Replacement, Knee; Female; Follow-Up Studies; Humans; Knee Joint; Knee Prosthesis; Male; Middle Aged; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Retrospective Studies; Vitamin E | 2016 |
The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups.
Topics: Acetabulum; Aged; Arthroplasty, Replacement, Hip; Coated Materials, Biocompatible; Cohort Studies; Female; Femur Head Necrosis; Follow-Up Studies; Hip Fractures; Hip Prosthesis; Humans; Male; Middle Aged; Osteoarthritis, Hip; Prospective Studies; Prosthesis Design; Prosthesis Failure; Risk Assessment; Switzerland; Time Factors; Titanium; Vitamin E | 2017 |
In vivo biological response to vitamin E and vitamin-E-doped polyethylene.
Topics: Analysis of Variance; Animals; Arthroplasty, Replacement, Hip; Biopsy, Needle; Disease Models, Animal; Dogs; Drug Carriers; Female; Immunohistochemistry; Injections, Intralesional; Knee Joint; Male; Materials Testing; Osteolysis; Polyethylenes; Prostheses and Implants; Prosthesis Design; Prosthesis Failure; Rabbits; Random Allocation; Risk Factors; Treatment Outcome; Vitamin E | 2010 |
Reduction of total knee replacement wear with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene.
Topics: Biocompatible Materials; Biomechanical Phenomena; Biomedical Engineering; Cross-Linking Reagents; Equipment Failure Analysis; Humans; In Vitro Techniques; Knee Prosthesis; Materials Testing; Polyethylenes; Prosthesis Failure; Vitamin E | 2011 |
Vitamin E blended UHMWPE may have the potential to reduce bacterial adhesive ability.
Topics: Antioxidants; Bacterial Adhesion; Humans; In Vitro Techniques; Materials Testing; Microscopy, Electron, Scanning; Oxidation-Reduction; Polyethylenes; Prostheses and Implants; Prosthesis Failure; Prosthesis-Related Infections; Spectroscopy, Fourier Transform Infrared; Staphylococcal Infections; Staphylococcus epidermidis; Vitamin E | 2011 |
Surface cross-linked UHMWPE can enable the use of larger femoral heads in total joints.
Topics: Antioxidants; Cross-Linking Reagents; Emulsifying Agents; Feasibility Studies; Femur Head; Gamma Rays; Hip Prosthesis; Humans; Materials Testing; Polyethylenes; Prosthesis Design; Prosthesis Failure; Stress, Mechanical; Tensile Strength; Vitamin E | 2013 |
Prevention of fatigue cracks in ultrahigh molecular weight polyethylene joint components by the addition of vitamin E.
Topics: Biocompatible Materials; Humans; In Vitro Techniques; Joint Prosthesis; Materials Testing; Molecular Weight; Polyethylenes; Prosthesis Failure; Stress, Mechanical; Surface Properties; Vitamin E | 1999 |