cobalt has been researched along with Cadaver in 7 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 1 (14.29) | 18.7374 |
1990's | 1 (14.29) | 18.2507 |
2000's | 2 (28.57) | 29.6817 |
2010's | 3 (42.86) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
Arnholt, C; Kerkhof, AL; Kurtz, SM; Lowell, J; MacDonald, D; Mihalko, WM; Perkins, M | 1 |
de Cesar Netto, C; Fritz, J; Kumar, NM; Schon, LC | 1 |
Hsiao, HM; Nikanorov, A; Prabhu, S; Razavi, MK | 1 |
Austman, RL; Dunning, CE; King, GJ | 1 |
Busse, B; Delling, G; Hahn, M; Jobke, B; Katzer, A; Niecke, M; PĆ¼schel, K | 1 |
Ghanayem, A; Lewin, J; Petersilge, C; Yoo, JU | 1 |
Feinendegen, LE; Kasperek, K; Klein, HJ; Schicha, H | 1 |
7 other study(ies) available for cobalt and Cadaver
Article | Year |
---|---|
Is Soft Tissue Laxity Associated with Tissue Metal Concentrations after Total Knee Arthroplasty?
Topics: Aged; Aged, 80 and over; Arthroplasty, Replacement, Knee; Biomechanical Phenomena; Cadaver; Chromium; Cobalt; Female; Humans; Joint Instability; Knee; Knee Joint; Knee Prosthesis; Male; Metals; Middle Aged; Prosthesis Failure; Range of Motion, Articular; Rotation; Titanium | 2018 |
Metal Artifact Reduction Magnetic Resonance Imaging Around Arthroplasty Implants: The Negative Effect of Long Echo Trains on the Implant-Related Artifact.
Topics: Ankle; Arthroplasty, Replacement, Ankle; Artifacts; Cadaver; Chromium; Cobalt; Humans; Image Processing, Computer-Assisted; Magnetic Resonance Imaging; Metals; Prostheses and Implants | 2017 |
Respiration-induced kidney motion on cobalt-chromium stent fatigue resistance.
Topics: Algorithms; Cadaver; Chromium; Cobalt; Equipment Design; Equipment Failure; Finite Element Analysis; Fluoroscopy; Humans; Kidney; Materials Testing; Renal Circulation; Respiratory Mechanics; Retroperitoneal Space; Stents | 2009 |
Bone stresses before and after insertion of two commercially available distal ulnar implants using finite element analysis.
Topics: Alloys; Arthroplasty, Replacement; Cadaver; Chromium; Cobalt; Finite Element Analysis; Humans; Materials Testing; Prostheses and Implants; Prosthesis Design; Prosthesis Implantation; Stress, Mechanical; Titanium; Ulna; Weight-Bearing | 2011 |
Allocation of nonbirefringent wear debris: darkfield illumination associated with PIXE microanalysis reveals cobalt deposition in mineralized bone matrix adjacent to CoCr implants.
Topics: Aged; Bone Matrix; Cadaver; Cobalt; Electron Probe Microanalysis; Female; Hip Prosthesis; Humans; Lighting; Male; Middle Aged; Prosthesis Failure; Vitallium | 2008 |
Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine.
Topics: Artifacts; Bone Screws; Cadaver; Chromium; Cobalt; Humans; Lumbar Vertebrae; Predictive Value of Tests; Sensitivity and Specificity; Spinal Fusion; Titanium; Tomography, X-Ray Computed | 1997 |
[Determination of age dependence of trace element concentrations in human cerebral cortex and basal ganglia].
Topics: Activation Analysis; Adolescent; Adult; Age Factors; Aged; Basal Ganglia; Cadaver; Cerebral Cortex; Cesium; Child; Child, Preschool; Chromium; Cobalt; Humans; Infant; Infant, Newborn; Iron; Middle Aged; Motor Cortex; Rubidium; Scandium; Silver; Trace Elements; Zinc | 1972 |