chondroitin-sulfates and Tibial-Fractures

chondroitin-sulfates has been researched along with Tibial-Fractures* in 2 studies

Other Studies

2 other study(ies) available for chondroitin-sulfates and Tibial-Fractures

ArticleYear
In vivo effects of coating loaded and unloaded Ti implants with collagen, chondroitin sulfate, and hydroxyapatite in the sheep tibia.
    Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2007, Volume: 25, Issue:8

    The in vivo effects of coating titanium implants with organic extracellular matrix molecules were examined in the sheep tibia. Titanium screws (5.0 mm) were coated with type I collagen (Ti/Coll) or type I collagen and chondroitin sulfate (Ti/Coll/CS) by biomimetic fibrillogenesis. Uncoated screws (Ti) and screws coated with hydroxyapatite (Ti/HA) served as control. Six adult female sheep received one screw of each type to stabilize a midshaft tibial fracture with external fixation. Four cylindrical implants of 4-mm outer diameter and 3.3-mm inner diameter with the same coatings were inserted into the tibial head. No pin track infections were seen at the time of implant retrieval 6 weeks after implantation. Extraction torque was greater for Ti/HA (1181 Nmm) and Ti/Coll/CS (1088 Nmm) compared to Ti/Coll (900 Nmm) and Ti (904 Nmm) [N.S.]. Newly formed bone was noted around all coated screws within the medullary cavity. Macrophage and osteoclast activity was significantly reduced around Ti/Coll/CS in both types of implants compared to uncoated controls (p < 0.05). Osteoblast activity was significantly increased around loaded Ti/Coll and Ti/Coll/CS screws compared to uncoated Ti screws (p < 0.05). Microtomographic evaluation (SRmicroCT) revealed no significant differences in new bone formation around the unloaded tibial head implants. Coating of external fixation devices with of type I collagen and chondroitin sulfate appears to have similar effects with respect to stability and bone healing as HA but with less osteoclast activity. These findings were more pronounced under loaded than unloaded conditions in the sheeptibia.

    Topics: Animals; Bone Screws; Chondroitin Sulfates; Coated Materials, Biocompatible; Collagen Type I; Durapatite; External Fixators; Fracture Fixation; Implants, Experimental; Microscopy, Electron, Scanning; Radiography; Tibial Fractures; Titanium

2007
Use of Integra to resurface a latissimus dorsi free flap.
    British journal of plastic surgery, 2003, Volume: 56, Issue:1

    The successful use of Integra to cover a muscle flap as a secondary reconstructive procedure is presented.

    Topics: Accidents, Traffic; Adolescent; Ankle Injuries; Biocompatible Materials; Chondroitin Sulfates; Collagen; Female; Fibula; Humans; Plastic Surgery Procedures; Surgical Flaps; Tibial Fractures; Treatment Outcome

2003