Page last updated: 2024-08-24

chloroquine diphosphate and Sensitivity and Specificity

chloroquine diphosphate has been researched along with Sensitivity and Specificity in 5 studies

Research

Studies (5)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's0 (0.00)18.2507
2000's4 (80.00)29.6817
2010's1 (20.00)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Bellows, DS; Clarke, ID; Diamandis, P; Dirks, PB; Graham, J; Jamieson, LG; Ling, EK; Sacher, AG; Tyers, M; Ward, RJ; Wildenhain, J1
Elliott, P; G'Sell, M; Ross, SE; Snyder, LM; Ventura, V1
Guo, M; Yao, S; Yin, F1
Burgess, G; Halverson, GR; Hart, K; Lee, E; Reid, ME1
Guo, M; Huang, Y; Pan, W; Yao, S1

Other Studies

5 other study(ies) available for chloroquine diphosphate and Sensitivity and Specificity

ArticleYear
Chemical genetics reveals a complex functional ground state of neural stem cells.
    Nature chemical biology, 2007, Volume: 3, Issue:5

    Topics: Animals; Cell Survival; Cells, Cultured; Mice; Molecular Structure; Neoplasms; Neurons; Pharmaceutical Preparations; Sensitivity and Specificity; Stem Cells

2007
Automated acoustic detection of mouse scratching.
    PloS one, 2017, Volume: 12, Issue:7

    Topics: Acoustics; Algorithms; Animals; Automation; Chloroquine; Mice, Inbred C57BL; Models, Theoretical; Pruritus; Reproducibility of Results; Sensitivity and Specificity; Skin; Time Factors

2017
Kinetics of DNA binding with chloroquine phosphate using capacitive sensing method.
    Biosensors & bioelectronics, 2003, Dec-15, Volume: 19, Issue:4

    Topics: Adsorption; Binding Sites; Biosensing Techniques; Chloroquine; DNA; Electric Capacitance; Electrochemistry; Electrodes; Kinetics; Macromolecular Substances; Online Systems; Reproducibility of Results; Sensitivity and Specificity

2003
Efficacy of murine monoclonal antibodies in RBC phenotyping of DAT-positive samples.
    Immunohematology, 2006, Volume: 22, Issue:4

    Topics: Anemia, Hemolytic, Autoimmune; Animals; Antibodies, Monoclonal; Autoantibodies; Blood Grouping and Crossmatching; Chloroquine; Erythrocytes; False Negative Reactions; False Positive Reactions; Flow Cytometry; Fluorescent Antibody Technique; Hemagglutination Tests; Humans; Isoantibodies; Mice; Sensitivity and Specificity

2006
Capillary electrophoresis with end-column electrochemiluminescence for the analysis of chloroquine phosphate and the study on its interaction with human serum albumin.
    Journal of chromatography. A, 2007, Jun-22, Volume: 1154, Issue:1-2

    Topics: Binding Sites; Chloroquine; Clomiphene; Electrochemistry; Electrophoresis, Capillary; Humans; Luminescent Measurements; Organometallic Compounds; Piperidines; Reproducibility of Results; Sensitivity and Specificity; Serum Albumin

2007