Page last updated: 2024-10-24

caffeine and Sensitivity and Specificity

caffeine has been researched along with Sensitivity and Specificity in 182 studies

Sensitivity and Specificity: Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed)

Research Excerpts

ExcerptRelevanceReference
"We have previously shown that a combination of glucosyl hesperidin (G-hesperidin) plus caffeine reduces accumulation of body fat, whereas G-hesperidin or caffeine alone shows little effect on high-fat diet-induced obesity in mice."9.22Oral intake of a combination of glucosyl hesperidin and caffeine elicits an anti-obesity effect in healthy, moderately obese subjects: a randomized double-blind placebo-controlled trial. ( Murosaki, S; Muroyama, K; Ohara, T; Yamamoto, Y, 2016)
"The most commonly used laboratory test for predicting malignant hyperthermia susceptibility is the caffeine halothane contracture test."9.07Prediction of malignant hyperthermia susceptibility in low-risk subjects. An epidemiologic investigation of caffeine halothane contracture responses. The North American Malignant Hyperthermia Registry. ( Bunn, JS; Diaz, M; Landis, JR; Larach, MG, 1992)
" The center followed the diagnostic protocols of the North America MH Group, in which the contractures of biopsies from the vastus lateralis muscle are analyzed after exposure to caffeine and halothane (CHCT)."7.76Use of the caffeine-halothane contracture test for the diagnosis of malignant hyperthermia in Brazil. ( Abreu, AV; Aguiar, MI; Cardoso, LA; Carmo, PL; Cunha, LB; Matos, AR; Sudo, RT; Trachez, MM; Zapata-Sudo, G, 2010)
" Clearance (Cl) was calculated using the equation of Cl = Kel x Vd (Kel = elimination rate constant, Vd = volume of distribution) and half-life was determined using pharmacokinetic analysis."5.31Caffeine clearance in patients with hepatocellular carcinoma after transcatheter oily chemoembolization treatment. ( Janchai, A; Mahachai, V; Tangkijvanich, P; Thong-Ngam, D; Thumvijit, L; Wittayalertpanya, S, 2002)
"We have previously shown that a combination of glucosyl hesperidin (G-hesperidin) plus caffeine reduces accumulation of body fat, whereas G-hesperidin or caffeine alone shows little effect on high-fat diet-induced obesity in mice."5.22Oral intake of a combination of glucosyl hesperidin and caffeine elicits an anti-obesity effect in healthy, moderately obese subjects: a randomized double-blind placebo-controlled trial. ( Murosaki, S; Muroyama, K; Ohara, T; Yamamoto, Y, 2016)
"This multicenter, randomized, double-blind, placebo-controlled, parallel-group study includes patients with suspected coronary artery disease who regularly consume caffeine."5.15Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: rationale and design of a prospective, randomized, multicenter study. ( Franks, B; Iskandrian, AE; McNutt, BE; Tejani, FH; Thompson, RC, 2011)
"The purpose of this study was to evaluate caffeine clearance, a quantitative measurement of metabolizing capacity of the liver, in chronic hepatitis B and C before and after interferon treatment."5.09Caffeine clearance in patients with chronic viral hepatitis: before and after interferon therapy. ( Mahachai, V; Wittayalertpanya, S, 2001)
"The most commonly used laboratory test for predicting malignant hyperthermia susceptibility is the caffeine halothane contracture test."5.07Prediction of malignant hyperthermia susceptibility in low-risk subjects. An epidemiologic investigation of caffeine halothane contracture responses. The North American Malignant Hyperthermia Registry. ( Bunn, JS; Diaz, M; Landis, JR; Larach, MG, 1992)
" Extreme PB was identified in 76 infants and in 45% was temporally associated with clinical events including infection or necrotizing enterocolitis (NEC), immunizations, or caffeine discontinuation."3.83Clinical associations with immature breathing in preterm infants: part 2-periodic breathing. ( Delos, J; Fairchild, K; Kattwinkel, J; Lake, D; Mohr, M; Moorman, JR; Patel, M; Sinkin, RA, 2016)
" The center followed the diagnostic protocols of the North America MH Group, in which the contractures of biopsies from the vastus lateralis muscle are analyzed after exposure to caffeine and halothane (CHCT)."3.76Use of the caffeine-halothane contracture test for the diagnosis of malignant hyperthermia in Brazil. ( Abreu, AV; Aguiar, MI; Cardoso, LA; Carmo, PL; Cunha, LB; Matos, AR; Sudo, RT; Trachez, MM; Zapata-Sudo, G, 2010)
"We have examined the modulation of radiosensitivity by using caffeine in two human sarcoma cell lines both with a p53 mutation (US8-93 and LMS6-93)."3.71Loss of G2/M arrest correlates with radiosensitization in two human sarcoma cell lines with mutant p53. ( Bache, M; Bartel, F; Dunst, J; Meye, A; Pigorsch, S; Rath, FW; Schmidt, H; Taubert, H; Würl, P, 2001)
"Caffeine has been extensively used as a probe to measure CYP1A2 activity in humans with caffeine clearance or the paraxanthine (major metabolite of caffeine) to caffeine concentration ratio being regarded as the preferred metric."2.75Caffeine and paraxanthine HPLC assay for CYP1A2 phenotype assessment using saliva and plasma. ( Gross, AS; McLachlan, AJ; Perera, V, 2010)
" To evaluate the sensitivity of the Finometer in recording longer-term effects of a daily dosage of 1000 mg vitamin C, 800 mg vitamin E and 10 mg folic acid, 14 young males took placebo and 17 took the vitamins for 12 weeks in a double-blind study."2.71Sensitivity of the Finometer device in detecting acute and medium-term changes in cardiovascular function. ( Huisman, HW; Jerling, JC; Oosthuizen, W; Schutte, AE; Van Rooyen, JM, 2003)
"Caffeine is a non-selective antagonist at the adenosine receptors, which is expected to reverse both the intended (coronary vasodilation) and unintended (hypotension, flushing) effects of exogenously administered adenosine and adenosine-related compounds."1.43Caffeine reduces the sensitivity of vasodilator MPI for the detection of myocardial ischaemia: Pro. ( Reyes, E, 2016)
" Here, a 3-h caffeine/colcemid co-treatment before harvesting at 55 h post-exposure is used so that the dicentric analysis using Giemsa staining is based predominantly on lymphocytes released from the G2-block, increasing thus dicentric yield and enabling construction of a dose-response calibration curve with improved precision of high-dose estimates."1.43Biodosimetry for High-Dose Exposures Based on Dicentric Analysis in Lymphocytes Released from the G2-Block by Caffeine. ( Dimitriou, P; Hatzi, V; Karachristou, I; Karaiskos, P; Karakosta, M; Pantelias, A; Pantelias, G; Terzoudi, GI; Thanassoulas, A, 2016)
"Caffeine has attracted abundant attention due to its extensive existence in beverages and medicines."1.39Make caffeine visible: a fluorescent caffeine "traffic light" detector. ( Agrawalla, BK; Chang, YT; Cho, YK; Er, JC; Kale, AA; Kim, TH; Xu, W; Zhai, D; Zhang, L, 2013)
" This method can be applied to the pharmacokinetic study of norfloxacin and enoxacin after repeated administration to assess changes in CYP1A2 activity in healthy subjects."1.37A simple chromatographic method for determining norfloxacin and enoxacin in pharmacokinetic study assessing CYP1A2 inhibition. ( Homma, M; Kobayashi, D; Kobayashi, T; Kohda, Y; Momo, K, 2011)
"Genotyping N-acetyltransferase 2 (NAT2) is of high relevance for individualized dosing of antituberculosis drugs and bladder cancer epidemiology."1.37Genotyping NAT2 with only two SNPs (rs1041983 and rs1801280) outperforms the tagging SNP rs1495741 and is equivalent to the conventional 7-SNP NAT2 genotype. ( Albers, P; Angeli-Greaves, M; Aslam, M; Bánfi, G; Barski, D; Blaszkewicz, M; Bolt, HM; Brenner, W; Dietrich, H; Ebbinghaus, R; Ekici, AB; Falkenstein, M; Frees, S; Gerullis, H; Golka, K; Guballa, C; Hassan Rizvi, SA; Hengstler, JG; Ickstadt, K; Klein, T; Kress, A; Lehmann, ML; Löhlein, D; Moormann, O; Niegisch, G; Otto, T; Ovsiannikov, D; Prager, HM; Reckwitz, T; Roemer, HC; Romics, I; Roth, G; Schöps, W; Schwender, H; Seidel, T; Selinski, S; Steffens, M; Thüroff, JW; Truss, MC; Weistenhöfer, W; Winterpacht, A; Zimmermann, A, 2011)
"The theanine in the tea was extracted with water."1.36[Theanine, EGCG and caffeine determinated by HPLC]. ( Cui, X; Diao, F; Dong, F; Guo, D; Liu, N; Wang, Q, 2010)
" The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described."1.34Stereospecific determination of cis- and trans-resveratrol in rat plasma by HPLC: application to pharmacokinetic studies. ( Chen, X; He, H; Ma, L; Ren, W; Wang, G; Yang, B; Yu, Q, 2007)
"Caffeine was determined in ground and instant coffee with precision and accuracy that meet Brazilian norms about such products."1.34Determination of caffeine in coffee products by dynamic complexation with 3,4-dimethoxycinnamate and separation by CZE. ( do Lago, CL; Nogueira, T, 2007)
" The results of the proposed method were in excellent agreement with those obtained from PLS and HPLC methods and can be satisfactorily used for routine analysis of multicomponent dosage forms."1.33Content uniformity and dissolution tests of triplicate mixtures by a double divisor-ratio spectra derivative method. ( Koundourellis, JE; Malliou, ET; Markopoulou, CK, 2005)
"Oxyphenbutazone in the sample was found to be present at a level below the quantification level of 10."1.32Analysis of adulterants in a traditional herbal medicinal product using liquid chromatography-mass spectrometry-mass spectrometry. ( Holmes, MJ; Koh, HL; Lau, AJ; Woo, SO, 2003)
" Clearance (Cl) was calculated using the equation of Cl = Kel x Vd (Kel = elimination rate constant, Vd = volume of distribution) and half-life was determined using pharmacokinetic analysis."1.31Caffeine clearance in patients with hepatocellular carcinoma after transcatheter oily chemoembolization treatment. ( Janchai, A; Mahachai, V; Tangkijvanich, P; Thong-Ngam, D; Thumvijit, L; Wittayalertpanya, S, 2002)
"Smoking during pregnancy is a significant public health issue, and studies of the effectiveness of interventions to reduce maternal smoking require accurate measurement of smoking status."1.31A simple high-pressure liquid chromatography cotinine assay: validation of smoking status in pregnant women. ( Brennecke, S; Greaves, R; Janus, E; Trotter, L, 2001)
"Caffeine was also very frequently present in river and ground water, although its presence in lake water was rare."1.31Use of an automated on-line SPE-HPLC method to monitor caffeine and selected aniline and phenol compounds in aquatic systems of Macedonia-Thrace, Greece. ( Koukourikou, A; Papadakis, E; Papadopoulou-Mourkidou, E; Patsias, J, 2001)
" MHEh muscles revealed a dose-response curve similar to that found in MHN specimens."1.30Classification of malignant hyperthermia-equivocal patients by 4-chloro-M-cresol. ( Bittner, RE; Fricker, R; Gilly, H; Kress, HG; Musat, I; Steinbereithner, K, 1997)
" The type of fibres (type I: oxidative, slow; type II: glycolytic, fast) were determined with strontium dose-response curves."1.30[Caffeine skinned fiber tension test: application to the diagnosis of susceptibility to malignant hyperthermia]. ( Adnet, P; Börtlein, ML; Etchrivi, T; Haudecoeur, G; Krivosic-Horber, R; Nivoche, Y; Tavernier, B, 1999)
"A rapid simple and robust reversed-phase HPLC method was developed for rapid screening in bioavailability studies or comparative bioequivalence studies."1.29Rapid high-performance liquid chromatographic determination of vancomycin in human plasma. ( Luksa, J; Marusic, A, 1995)
"30 hours, and bioavailability of 99."1.29Application of an enzyme-multiplied immunoassay technique for determination of caffeine elimination kinetics as a test of liver function in clinically normal dogs. ( DeGraves, FJ; Golden, DL; Spano, JS; Whatley, EM; Wilson, RC, 1994)
" Cumulative dose-response curves for chlordiazepoxide were obtained before and during chronic chlordiazepoxide administration and during chronic saline administration."1.29Tolerance to the behavioral effects of chlordiazepoxide: pharmacological and biochemical selectivity. ( Alastra, AJ; Cohen, C; Goldberg, SR; Marley, RJ; Sannerud, CA; Serdikoff, SL, 1993)
"Caffeine sensitivity was defined as the threshold concentration inducing > 10% of the maximal tension obtained after the fiber was loaded with a 1."1.29In vitro human masseter muscle hypersensitivity: a possible explanation for increase in masseter tone. ( Adnet, PJ; Etchrivi, T; Haudecoeur, G; Krivosic, I; Krivosic-Horber, R; Reyford, H; Tavernier, BM, 1996)

Research

Studies (182)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's45 (24.73)18.2507
2000's85 (46.70)29.6817
2010's46 (25.27)24.3611
2020's6 (3.30)2.80

Authors

AuthorsStudies
Diamandis, P1
Wildenhain, J1
Clarke, ID1
Sacher, AG1
Graham, J1
Bellows, DS1
Ling, EK1
Ward, RJ1
Jamieson, LG1
Tyers, M1
Dirks, PB1
Li, H1
Sun, J1
Sui, X1
Liu, J1
Yan, Z1
Liu, X1
Sun, Y1
He, Z1
Sebaiy, MM1
El-Adl, SM1
Mattar, AA1
Mendes, VM1
Coelho, M1
Tomé, AR1
Cunha, RA1
Manadas, B1
van Assen, M1
Kuijpers, DJ1
Schwitter, J1
Ahmad, R1
Ahmad, N1
Al-Anaki, WS1
Ismail, FA1
Al-Jishi, F1
Eagles, SK1
Wang, X1
Gross, AS2
McLachlan, AJ2
Zhang, YS2
Lee, HE1
Kwan, CC1
Schwartz, GW1
Fawzi, AA1
Ibrahim, H1
Hamdy, AM1
Merey, HA1
Saad, AS1
De Luca, S1
Ciotoli, E1
Biancolillo, A1
Bucci, R1
Magrì, AD1
Marini, F1
Williams, TM1
Nyati, S1
Ross, BD1
Rehemtulla, A1
Hadad, GM1
Abdel Salam, RA1
Soliman, RM1
Mesbah, MK1
Talio, MC1
Alesso, M1
Acosta, M1
Acosta, MG1
Luconi, MO1
Fernández, LP1
Xu, W1
Kim, TH1
Zhai, D1
Er, JC1
Zhang, L2
Kale, AA1
Agrawalla, BK1
Cho, YK1
Chang, YT1
Peris-Vicente, J1
Rambla-Alegre, M1
Durgavanshi, A1
Bose, D1
Esteve-Romero, J2
Marco-Peiró, S1
Manthorpe, DP1
Lockley, WJ1
Lboutounne, Y1
Silva, J1
Pazart, L1
Bérard, M1
Muret, P1
Humbert, P1
Carlsson, M1
Jögi, J1
Markenroth Bloch, K1
Hedén, B1
Ekelund, U1
Ståhlberg, F1
Arheden, H1
Rezaei, B1
Khalili Boroujeni, M1
Ensafi, AA1
Mohanty, SK1
Yu, CL1
Gopishetty, S1
Subramanian, M1
Alur, P1
Bollampalli, V1
Bell, T1
Hussain, N1
Liss, J1
Mutsaerts, HJ1
Steketee, RM1
Heijtel, DF1
Kuijer, JP1
van Osch, MJ1
Majoie, CB1
Smits, M1
Nederveen, AJ1
Ghosn, R1
Yahia-Cherif, L1
Hugueville, L1
Ducorps, A1
Lemaréchal, JD1
Thuróczy, G1
de Seze, R1
Selmaoui, B1
Jordan, NY1
Mimpen, JY1
van den Bogaard, WJ1
Flesch, FM1
van de Meent, MH1
Torano, JS1
De Kesel, PM1
Lambert, WE1
Stove, CP1
Saito-Shida, S1
Nemoto, S1
Teshima, R1
Ohara, T1
Muroyama, K1
Yamamoto, Y1
Murosaki, S1
Reyes, E2
Patel, M1
Mohr, M1
Lake, D1
Delos, J1
Moorman, JR1
Sinkin, RA1
Kattwinkel, J1
Fairchild, K1
Karachristou, I1
Karakosta, M1
Pantelias, A1
Hatzi, V1
Pantelias, G1
Thanassoulas, A1
Karaiskos, P1
Dimitriou, P1
Terzoudi, GI1
Dhodapkar, R1
Kumar, A1
Bessems, JGM1
Paini, A1
Gajewska, M1
Worth, A1
Niedorf, F1
Schmidt, E1
Kietzmann, M1
Katsu, T1
Tsunamoto, Y1
Hanioka, N1
Komagoe, K1
Masuda, K1
Narimatsu, S1
Ogawa, A1
Maeda, M1
Filimonova, AA1
Ziganshina, LE1
Chichirov, AA1
Ganio, MS1
Klau, JF1
Casa, DJ2
Armstrong, LE2
Maresh, CM2
Klimacka-Nawrot, E1
Suchecka, W1
Xie, S1
Walton, SP1
Thabano, JR1
Breadmore, MC1
Hutchinson, JP1
Johns, C1
Haddad, PR1
Nováková, L1
Spácil, Z1
Seifrtová, M1
Opletal, L1
Solich, P2
Carvalho, JJ1
Weller, MG1
Panne, U1
Schneider, RJ2
Diao, F1
Dong, F1
Wang, Q1
Liu, N1
Guo, D1
Cui, X1
Choong, CL1
Milne, WI1
Chen, ML1
Zheng, MM1
Feng, YQ1
Banko, LT1
Haq, SA1
Rainaldi, DA1
Klem, I1
Siegler, J1
Fogel, J1
Sacchi, TJ1
Heitner, JF1
Sudo, RT1
Cunha, LB1
Carmo, PL1
Matos, AR1
Trachez, MM1
Cardoso, LA1
Aguiar, MI1
Abreu, AV1
Zapata-Sudo, G1
Panchal, JG1
Patel, RV1
Menon, SK1
Kobayashi, T1
Homma, M1
Momo, K1
Kobayashi, D1
Kohda, Y1
Fujima, N1
Kudo, K1
Terae, S1
Ishizaka, K1
Yazu, R1
Zaitsu, Y1
Tha, KK1
Yoshida, D1
Tsukahara, A1
Haacke, ME1
Sasaki, M1
Shirato, H1
Perera, V1
Tejani, FH1
Thompson, RC1
Iskandrian, AE1
McNutt, BE1
Franks, B1
Serra, A1
Macià, A1
Romero, MP1
Piñol, C1
Motilva, MJ1
Selinski, S1
Blaszkewicz, M1
Lehmann, ML1
Ovsiannikov, D1
Moormann, O1
Guballa, C1
Kress, A1
Truss, MC1
Gerullis, H1
Otto, T1
Barski, D1
Niegisch, G1
Albers, P1
Frees, S1
Brenner, W1
Thüroff, JW1
Angeli-Greaves, M1
Seidel, T1
Roth, G1
Dietrich, H1
Ebbinghaus, R1
Prager, HM1
Bolt, HM1
Falkenstein, M1
Zimmermann, A1
Klein, T1
Reckwitz, T1
Roemer, HC1
Löhlein, D1
Weistenhöfer, W1
Schöps, W1
Hassan Rizvi, SA1
Aslam, M1
Bánfi, G1
Romics, I1
Steffens, M1
Ekici, AB1
Winterpacht, A1
Ickstadt, K1
Schwender, H1
Hengstler, JG1
Golka, K1
Kujawinski, DM1
Jochmann, MA1
Schmidt, TC1
Pinhancos, R1
Maass, S1
Ramanathan, DM1
Lee, JC1
Fraser, JF1
Barnett, AG1
Johnson, LP1
Wilson, MG1
McHenry, CM1
Walters, DL1
Warnholtz, CR1
Khafagi, FA1
Liu, Y1
Li, X1
Yang, C1
Tai, S1
Zhang, X1
Liu, G1
Mahapatra, AK1
Roy, J1
Sahoo, P1
Mukhopadhyay, SK1
Mukhopadhyay, AR1
Mandal, D1
Lopez-Avila, V1
Cooley, J1
Urdahl, R1
Thevis, M1
Grandke, J1
Oberleitner, L1
Resch-Genger, U1
Garbe, LA1
Izu, LT1
McCulle, SL1
Ferreri-Jacobia, MT1
Devor, DC1
Duffey, ME1
Zheng, XM1
Williams, RC1
Islander, G3
Ording, H4
Bendixen, D3
Ranklev Twetman, E2
Sekella, PT1
Rueda, D1
Walter, NG1
Doherty, M1
Smith, PM1
Davison, RC1
Hughes, MG1
Chen, Z1
Pavelic, P1
Dillon, P1
Naidu, R1
Reeves, RR1
Struve, FA1
Patrick, G1
Gardinali, PR1
Zhao, X1
Conney, AH1
Lu, YP1
Lou, YR1
Huang, MT1
Lau, AJ1
Holmes, MJ1
Woo, SO1
Koh, HL1
Thong-Ngam, D2
Thumvijit, L1
Tangkijvanich, P2
Janchai, A1
Mahachai, V3
Wittayalertpanya, S3
Schneider, H1
Ma, L2
Glatt, H1
Wappler, F2
Anetseder, M1
Baur, CP1
Censier, K1
Doetsch, S1
Felleiter, P1
Fiege, M1
Fricker, R2
Halsall, PJ2
Hartung, E2
Heffron, JJ2
Heytens, L2
Hopkins, PM1
Klingler, W1
Lehmann-Horn, F2
Nivoche, Y3
Tegazzin, V2
Tzanova, I1
Urwyler, A2
Weisshorn, R1
Schulte am Esch, J1
Zhang, LQ1
Wu, XH1
Tang, X1
Zhu, XL1
Su, WT1
Zhang, J1
Zhang, XS1
Huang, XR1
Fu, CM1
Liu, WN1
Zhang, ZH1
Song, WS1
Huang, J1
Wang, SX1
Sawyer, M1
Kumar, V1
Schutte, AE1
Huisman, HW1
Van Rooyen, JM1
Oosthuizen, W1
Jerling, JC1
Taylor, ES1
Smith, AD1
Cowan, JO1
Herbison, GP1
Taylor, DR1
Haller, CA1
Jacob, P1
Benowitz, NL1
Satínský, D1
Neto, I1
Sklenákova, H1
Conceição, M1
Montenegro, BS1
Araújo, AN1
Jerdi, MC1
Daali, Y1
Oestreicher, MK1
Cherkaoui, S1
Dayer, P1
Emara, S1
Tang, K1
Page, JS1
Smith, RD1
Zydroń, M1
Baranowski, J1
Baranowska, I1
Martinavarro-Domínguez, A1
Boseb, D1
Durgbanshi, A2
Gil-Agustí, M1
Capella-Peiró, ME1
Broch, SC1
Ling, Y1
Zhao, YF1
Li, ZJ1
Zhang, G1
Wu, Y1
Lambert, JP1
Mullett, WM1
Kwong, E1
Lubda, D1
Markopoulou, CK1
Malliou, ET1
Koundourellis, JE1
Dalmázio, I1
Santos, LS1
Lopes, RP1
Eberlin, MN1
Augusti, R1
Ito, H1
Gonthier, MP1
Manach, C1
Morand, C1
Mennen, L1
Rémésy, C1
Scalbert, A1
Zhang, QL1
Lian, HZ1
Wang, WH1
Chen, HY1
Heaps, DA1
Griffiths, PR1
Hansen, JL1
Reed, DR1
Wright, MJ1
Martin, NG1
Breslin, PA1
Verenitch, SS1
Lowe, CJ1
Mazumder, A1
Tort, AB1
Neto, WP1
Amaral, OB1
Kazlauckas, V1
Souza, DO1
Lara, DR1
Tarantino, G1
Conca, P1
Capone, D1
Gentile, A1
Polichetti, G1
Basile, V1
Gilbert-López, B1
Llorent-Martínez, EJ1
Ortega-Barrales, P1
Molina-Díaz, A2
Begas, E1
Kouvaras, E1
Tsakalof, A1
Papakosta, S1
Asprodini, EK1
Redshaw, N1
Dickson, SJ1
Ambrose, V1
Horswell, J1
Chen, X1
He, H1
Wang, G1
Yang, B1
Ren, W1
Yu, Q1
Babu, VR1
Patra, S1
Karanth, NG1
Kumar, MA1
Thakur, MS1
Bassini-Cameron, A1
Sweet, E1
Bottino, A1
Bittar, C1
Veiga, C1
Cameron, LC1
Weaver, PJ1
Laures, AM1
Wolff, JC1
Pellegrini, M1
Marchei, E1
Rossi, S1
Vagnarelli, F1
García-Algar, O1
Vall, O1
Pichini, S1
Nogueira, T1
do Lago, CL1
Mendu, DR1
Chou, PP1
Soldin, SJ1
Shrivas, K1
Wu, HF1
Borre, Y1
Chandrashekar, S1
Dougan, JD1
Heidenreich, BA1
Farmer-Dougan, V1
Ellegård, EK1
Hay, KD1
Morton, RP1
Yamauchi, Y1
Nakamura, A1
Kohno, I1
Hatanaka, K1
Kitai, M1
Tanimoto, T1
Boylan, SM1
Cade, JE1
Kirk, SF1
Greenwood, DC1
White, KL1
Shires, S1
Simpson, NA1
Wild, CP1
Hay, AW1
Sökmen, B1
Kraemer, WJ1
Dias, JC1
Judelson, DA1
Hoffman, JR1
Ratamess, NA1
Ross, R1
Shanklin, M1
Kang, J1
Faigenbaum, AD1
Mohr, FC1
Alojipan, SV1
Dunston, SK1
Pessah, IN1
Burnett, JR1
Lim, CW1
Mahoney, GN1
Crooke, MJ1
Sarter, M1
Bushnell, PJ1
Hieda, Y1
Kashimura, S1
Hara, K1
Kageura, M1
Luksa, J1
Marusic, A1
Poulsen, JC1
Caspersen, C1
Mathiasen, D1
East, JM1
Tunwell, RE1
Lai, FA1
Maeda, N1
Mikoshiba, K2
Treiman, M1
Golden, DL1
Spano, JS1
Wilson, RC1
DeGraves, FJ1
Whatley, EM1
Nakazato, Y1
Tani, Y1
Teraoka, H1
Sugawara, T1
Asano, T1
Ohta, T1
Ito, S1
Lukkari, P1
Sirén, H1
Pantsar, M1
Riekkola, ML1
Ryan, AJ1
Squires, S1
Strutt, HL1
Evans, A1
Johnson, RT1
Paul, S1
Kurunwune, B1
Biaggioni, I1
Sannerud, CA1
Marley, RJ1
Serdikoff, SL1
Alastra, AJ1
Cohen, C1
Goldberg, SR1
Damiani, E1
Larsson, L1
Margreth, A1
Kirischuk, S1
Voitenko, N1
Kostyuk, P1
Verkhratsky, A1
Schreiber-Deturmeny, E1
Bruguerolle, B1
Adnet, PJ1
Reyford, H1
Tavernier, BM1
Etchrivi, T2
Krivosic, I1
Krivosic-Horber, R3
Haudecoeur, G2
Peng, Y1
Huchet-Cadiou, C1
Bonnet, V1
Même, W1
Léoty, C1
Delbeke, FT1
De Backer, P1
O'Brien, PJ1
Li, G1
Rostami-Hodjegan, A1
Nurminen, S1
Jackson, PR1
Tucker, GT1
Gilly, H1
Musat, I1
Bittner, RE1
Steinbereithner, K1
Kress, HG1
Mösli Waldhauser, SS1
Gillies, FM1
Crozier, A1
Baumann, TW1
Zimmermann, GR1
Jenison, RD1
Wick, CL1
Simorre, JP1
Pardi, A1
Brancadoro, V1
Cozzolino, S1
Ellis, FR1
Glauber, V2
Gonano, EF1
Kozak-Ribbens, G1
Kress, H1
Mortier, W1
Ranklev-Twetman, E1
Sigurdsson, S1
Snoeck, M1
Stieglitz, P1
Maruyama, T1
Kanaji, T1
Nakade, S1
Kanno, T1
Ben Abraham, R1
Zweig, A1
Perel, A1
Fagerlund, TH1
Berg, K1
Regal, KA1
Howald, WN1
Peter, RM1
Gartner, CA1
Kunze, KL1
Nelson, SD1
Evans, KW1
Boan, JA1
Evans, JL1
Shuaib, A1
Twetman, ER1
Schrader, E1
Klaunick, G1
Jorritsma, U1
Neurath, H1
Hirsch-Ernst, KI1
Kahl, GF1
Foth, H1
Ou-Yang, DS1
Huang, SL1
Xie, HG1
Wang, CY1
Zhou, HH1
Kusonsolboon, T1
Koch, JP1
ten Tusscher, GW1
Koppe, JG1
Guchelaar, HJ1
Adnet, P1
Börtlein, ML1
Tavernier, B1
Scott, RJ1
Palmer, J1
Lewis, IA1
Pleasance, S1
Jin, W1
Yu, D1
Dong, Q1
Ye, X1
Ruiz Medina, A1
Fernandez de Córdova, ML1
Liang, C1
Peng, H1
Bao, X1
Nie, L1
Yao, S1
Li, B1
Yang, Y1
Gan, Y1
Eaton, CD1
He, P1
Jones, AD1
Mittal, S1
Alexander, KS1
Dollimore, D1
Bendriss, EK1
Markoglou, N1
Wainer, IW1
Ishihama, Y1
Katayama, H1
Asakawa, N1
Kanazawa, H1
Kizu, J1
Matsushima, Y1
Patsias, J2
Papadopoulou-Mourkidou, E2
Garrigues, JM1
Bouhsain, Z1
Garrigues, S1
de la Guardia, M1
Bache, M1
Pigorsch, S1
Dunst, J1
Würl, P1
Meye, A1
Bartel, F1
Schmidt, H1
Rath, FW1
Taubert, H1
Brown, J1
Kreiger, N1
Darlington, GA1
Sloan, M1
Simon, RE1
Walton, LK1
Liang, Y1
Denton, MB1
Cubero-Castillo, E1
Noble, AC1
Greaves, R1
Trotter, L1
Brennecke, S1
Janus, E1
Georgia, KA1
Samanidou, VF1
Papadoyannis, IN1
Pura Naik, J1
Rosenberg, H1
Antognini, JF1
Muldoon, S1
Papadakis, E1
Koukourikou, A1
Bispo, MS1
Veloso, MC1
Pinheiro, HL1
De Oliveira, RF1
Reis, JO1
De Andrade, JB1
Mohamed, I1
Klauke, N1
Hentschel, J1
Cohen, J1
Plattner, H1
Copello, JA1
Barg, S1
Sonnleitner, A1
Porta, M1
Diaz-Sylvester, P1
Fill, M1
Schindler, H1
Fleischer, S1
Jelmert, O1
Hansteen, IL1
Langård, S1
Bonaïti-Pellié, C1
Poisson, N1
Bechtel, Y1
Bechtel, P1
Kuba, K1
Hua, SY1
Nohmi, M1
Larach, MG1
Landis, JR1
Bunn, JS1
Diaz, M1
Teeuwen, HW1
Elbers, EL1
van Rossum, JM1

Clinical Trials (5)

Trial Overview

TrialPhaseEnrollmentStudy TypeStart DateStatus
A Double-blind, Randomized, Placebo-controlled Study to Evaluate the Effects of a Weight Management Program on Body Weight in Individuals Who Are Overweight and Otherwise Healthy[NCT04107155]54 participants (Actual)Interventional2019-07-23Completed
A Randomized Controlled Trial to Evaluate the Effects of Repeated Periods of Modified Fasting to Support Healthy Natural Weight Management and Prevention of Weight Gain in Overweight But Generally Healthy Adults Over the Winter Holiday Period[NCT03372109]23 participants (Actual)Interventional2017-11-14Completed
Does Combined Caffeine and Carbohydrate Ingestion Counter the Exercise-mediated Fall in Glycaemia in Individuals With Type 1 Diabetes on Insulin Degludec? The DE-CAF Study[NCT04671043]21 participants (Actual)Interventional2022-02-04Completed
Pharmacokinetics (PK) and Safety of Caffeine in Neonates With Hypoxic Ischemic Encephalopathy Receiving Therapeutic Hypothermia[NCT05295784]Phase 118 participants (Anticipated)Interventional2024-06-30Not yet recruiting
A Phase 3b, Multicenter, Randomized, Double-Blind, Placebo-Controlled Study to Evaluate the Effect of Caffeine Intake on Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging (MPI) in Subjects Administered Regadenoson[NCT00826280]Phase 3347 participants (Actual)Interventional2009-03-24Completed
[information is prepared from clinicaltrials.gov, extracted Sep-2024]

Trial Outcomes

Change From Baseline in Diastolic Blood Pressure

"Baseline is the last non-missing measurement on or before first dose of regadenoson.~Change is calculated as the time point minus baseline." (NCT00826280)
Timeframe: Baseline, Day 5 (-3 min), Day 5 (+3 min), Day 5 (+15 min)

,,
InterventionmmHg (Median)
Baseline [N= 113; 116;116]Change at Day 5 (- 3 min) [N=67; 70; 71]Change at Day 5 (+ 3 min) [N=67; 70; 72]Change at Day 5 (+15 min) [N=66; 72; 72]
Caffeine 200 mg Plus Regadenoson74.04.04.03.0
Caffeine 400 mg Plus Regadenoson73.06.03.04.0
Placebo Plus Regadenoson78.00.0-1.0-2.0

Change From Baseline in Heart Rate

"Baseline is the last non-missing measurement on or before first dose of regadenoson~Change is calculated as the time point minus baseline." (NCT00826280)
Timeframe: Baseline, Day 5 (-3 min), Day 5 (+3 min), Day 5 (+15 min)

,,
InterventionBeats per minute (Median)
Baseline [N=113; 116; 116]Change at Day 5 (- 3 min) [N=67; 70; 71]Change at Day 5 (+3 min) [N=67; 70; 72]Change at Day 5 (+15 min) [N=66; 72; 72]
Caffeine 200 mg Plus Regadenoson62.0-1.05.01.0
Caffeine 400 mg Plus Regadenoson64.0-2.00.0-1.0
Placebo Plus Regadenoson66.0-2.09.04.0

Change From Baseline in Systolic Blood Pressure

"Baseline is the last non-missing measurement on or before first dose of regadenoson.~Change is calculated as the time point minus baseline." (NCT00826280)
Timeframe: Baseline, Day 5 (-3 min), Day 5 (+3 min), Day 5 (+15 min)

,,
InterventionmmHg (Median)
Baseline [N=113; 116; 116]Change at Day 5 (- 3 min) [N=67;70;71]Change at Day 5 (+3 min) [N=67; 70; 72]Change at Day 5 (+15 min) [N=66; 72; 72]
Caffeine 200 mg Plus Regadenoson131.012.08.08.0
Caffeine 400 mg Plus Regadenoson135.011.07.55.0
Placebo Plus Regadenoson135.00.00.0-2.0

Change in Number of Reversible Defects

"Each segment of the 17-Segment Model was assessed for radiotracer uptake on a scale of 0 (normal uptake) to 4 (absent uptake). Segments were counted as having a reversible defect if the stress score was greater than the rest score and the stress score was ≥ 2.~Change was calculated as the number of reversible defects using regadenoson with caffeine/placebo (Day 5) minus the number of reversible defects using regadenoson alone (Day 3)." (NCT00826280)
Timeframe: Day 3 and Day 5

,,
InterventionReversible Defects (Mean)
Baseline Stress Scan (Day 3)Double-Blind Stress Scan (Day 5)DoubleBlind - Baseline (Day 5 - Day 3)
Caffeine 200 mg Plus Regadenoson1.010.40-0.61
Caffeine 400 mg Plus Regadenoson1.000.38-0.62
Placebo Plus Regadenoson0.670.800.12

Change in Number of Reversible Defects Assessed by Computerized Quantitation

"Each segment of the 17-Segment Model was assessed for radiotracer uptake on a scale of 0 (normal uptake) to 4 (absent uptake). Segments were counted as having a reversible defect if the stress score was greater than the rest score and the stress score was ≥ 2.~Change was calculated as the number of reversible defects using regadenoson with caffeine/placebo (Day 5) minus the number of reversible defects using regadenoson alone (Day 3)." (NCT00826280)
Timeframe: Day 3 and Day 5

,,
InterventionReversible Defects (Mean)
Baseline Stress Scan (Day 3) [N=64; 69; 70]Double-Blind Stress Scan (Day 5) [N=66; 70; 71]DoubleBlind - Baseline (Day 5-Day 3)[N=64; 69; 70]
Caffeine 200 mg Plus Regadenoson2.001.46-0.59
Caffeine 400 mg Plus Regadenoson2.191.42-0.81
Placebo Plus Regadenoson1.471.740.31

Change in Summed Difference Score (SDS) Across All 17 Segments

"The Summed Difference Score was calculated as the difference in the Summed Stress Score across the 17 segments (scan run under stress condition) minus the Summed Rest Score across the 17 segments (scan run under rest conditions).~Change in SDS was calculated as the SDS for regadenoson with caffeine/placebo stress scan (Day 5) minus the SDS for regadenoson only stress scan (Day 3).~The full range of the SDS is -68 to 68, where 0 represents no change between Summed Stress Score and Summed Rest Score. A higher positive score indicates more severe coronary artery disease (CAD)." (NCT00826280)
Timeframe: Day 3 and Day 5

,,
InterventionSum Difference Score (Mean)
Baseline Stress Scan (Day 3)Double-Blind Stress Scan (Day 5)DoubleBlind - Baseline (Day 5 - Day 3)
Caffeine 200 mg Plus Regadenoson2.451.42-1.03
Caffeine 400 mg Plus Regadenoson2.531.27-1.25
Placebo Plus Regadenoson2.242.360.11

Change in Summed Difference Score Across All 17 Segments Assessed by Computerized Quantitation

"The Summed Difference Score was calculated as the difference in the Summed Stress Score across the 17 segments (scan run under stress condition) minus the Summed Rest Score across the 17 segments (scan run under rest conditions).~Change in SDS was calculated as the SDS for regadenoson with caffeine/placebo stress scan (Day 5) minus the SDS for regadenoson only stress scan (Day 3).~The full range of the SDS is -68 to 68, where 0 represents no change between Summed Stress Score and Summed Rest Score. A higher positive score indicates more severe coronary artery disease (CAD)." (NCT00826280)
Timeframe: Day 3 and Day 5

,,
InterventionSummed Difference Score (Mean)
Baseline Stress Scan (Day 3) [N=64; 69; 70]Double-Blind Stress Scan (Day 5) [N=66; 70; 71]DoubleBlind - Baseline (Day 5-Day 3)[N=64; 69; 70]
Caffeine 200 mg Plus Regadenoson4.463.10-1.45
Caffeine 400 mg Plus Regadenoson4.292.46-1.84
Placebo Plus Regadenoson3.344.411.02

Reviews

5 reviews available for caffeine and Sensitivity and Specificity

ArticleYear
MRI perfusion in patients with stable chest-pain.
    The British journal of radiology, 2020, Sep-01, Volume: 93, Issue:1113

    Topics: Artifacts; Caffeine; Central Nervous System Stimulants; Chest Pain; Coronary Angiography; Coronary A

2020
Effect of caffeine on sport-specific endurance performance: a systematic review.
    Journal of strength and conditioning research, 2009, Volume: 23, Issue:1

    Topics: Athletic Performance; Caffeine; Central Nervous System Stimulants; Female; Humans; Male; Muscle, Ske

2009
[Methods of taste sensitivity examination].
    Wiadomosci lekarskie (Warsaw, Poland : 1960), 2008, Volume: 61, Issue:7-9

    Topics: Caffeine; Citric Acid; Electrodiagnosis; Humans; Sensitivity and Specificity; Sodium Chloride; Sodiu

2008
Caffeine use in sports: considerations for the athlete.
    Journal of strength and conditioning research, 2008, Volume: 22, Issue:3

    Topics: Athletic Performance; Caffeine; Central Nervous System; Evidence-Based Medicine; Female; Humans; Mal

2008
[Simultaneous determination of theophylline and its metabolites by HPLC].
    Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan, 2000, Volume: 120, Issue:10

    Topics: Caffeine; Chromatography, High Pressure Liquid; Humans; Sensitivity and Specificity; Theophylline; X

2000

Trials

21 trials available for caffeine and Sensitivity and Specificity

ArticleYear
Submaximal adenosine-induced coronary hyperaemia with 12 h caffeine abstinence: implications for clinical adenosine perfusion imaging tests.
    Clinical physiology and functional imaging, 2015, Volume: 35, Issue:1

    Topics: Adenosine; Adult; Blood Flow Velocity; Caffeine; Coronary Circulation; Drug Administration Schedule;

2015
Reproducibility of pharmacological ASL using sequences from different vendors: implications for multicenter drug studies.
    Magma (New York, N.Y.), 2015, Volume: 28, Issue:5

    Topics: Brain; Caffeine; Cerebrovascular Circulation; Dose-Response Relationship, Drug; Drug Evaluation; Equ

2015
Radiofrequency signal affects alpha band in resting electroencephalogram.
    Journal of neurophysiology, 2015, Apr-01, Volume: 113, Issue:7

    Topics: Adult; Alpha Rhythm; Caffeine; Cell Phone; Electroencephalography; Female; Humans; Hydrocortisone; M

2015
Oral intake of a combination of glucosyl hesperidin and caffeine elicits an anti-obesity effect in healthy, moderately obese subjects: a randomized double-blind placebo-controlled trial.
    Nutrition journal, 2016, Jan-19, Volume: 15

    Topics: Abdominal Fat; Adiposity; Adult; Aged; Anti-Obesity Agents; Body Mass Index; Caffeine; Dose-Response

2016
Oral intake of a combination of glucosyl hesperidin and caffeine elicits an anti-obesity effect in healthy, moderately obese subjects: a randomized double-blind placebo-controlled trial.
    Nutrition journal, 2016, Jan-19, Volume: 15

    Topics: Abdominal Fat; Adiposity; Adult; Aged; Anti-Obesity Agents; Body Mass Index; Caffeine; Dose-Response

2016
Oral intake of a combination of glucosyl hesperidin and caffeine elicits an anti-obesity effect in healthy, moderately obese subjects: a randomized double-blind placebo-controlled trial.
    Nutrition journal, 2016, Jan-19, Volume: 15

    Topics: Abdominal Fat; Adiposity; Adult; Aged; Anti-Obesity Agents; Body Mass Index; Caffeine; Dose-Response

2016
Oral intake of a combination of glucosyl hesperidin and caffeine elicits an anti-obesity effect in healthy, moderately obese subjects: a randomized double-blind placebo-controlled trial.
    Nutrition journal, 2016, Jan-19, Volume: 15

    Topics: Abdominal Fat; Adiposity; Adult; Aged; Anti-Obesity Agents; Body Mass Index; Caffeine; Dose-Response

2016
Incidence of caffeine in serum of patients undergoing dipyridamole myocardial perfusion stress test by an intensive versus routine caffeine history screening.
    The American journal of cardiology, 2010, May-15, Volume: 105, Issue:10

    Topics: Aged; Caffeine; Coronary Disease; Dipyridamole; Drug Interactions; Exercise Test; Female; Hemodynami

2010
Caffeine and paraxanthine HPLC assay for CYP1A2 phenotype assessment using saliva and plasma.
    Biomedical chromatography : BMC, 2010, Volume: 24, Issue:10

    Topics: Area Under Curve; Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 CYP1A2; Drug Stab

2010
Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: rationale and design of a prospective, randomized, multicenter study.
    Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2011, Volume: 18, Issue:1

    Topics: Adenosine A2 Receptor Antagonists; Administration, Oral; Adult; Aged; Aged, 80 and over; Caffeine; C

2011
Effect of caffeine on adenosine-induced reversible perfusion defects assessed by automated analysis.
    Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2012, Volume: 19, Issue:3

    Topics: Adenosine; Blood Flow Velocity; Caffeine; Coronary Artery Disease; Coronary Circulation; Drug Intera

2012
Serum caffeine levels after 24-hour abstention: clinical implications on dipyridamole (201)Tl myocardial perfusion imaging.
    Journal of nuclear medicine technology, 2002, Volume: 30, Issue:3

    Topics: Aged; Blood Pressure; Caffeine; Central Nervous System Stimulants; Dipyridamole; Exercise Test; Fals

2002
Caffeine is ergogenic after supplementation of oral creatine monohydrate.
    Medicine and science in sports and exercise, 2002, Volume: 34, Issue:11

    Topics: Adult; Anaerobic Threshold; Analysis of Variance; Blood Chemical Analysis; Blood Gas Analysis; Caffe

2002
Topographic quantitative EEG response to acute caffeine withdrawal: a comprehensive analysis of multiple quantitative variables.
    Clinical EEG (electroencephalography), 2002, Volume: 33, Issue:4

    Topics: Adolescent; Adult; Alpha Rhythm; Analysis of Variance; Beta Rhythm; Brain Mapping; Caffeine; Cerebra

2002
Multicentre evaluation of in vitro contracture testing with bolus administration of 4-chloro-m-cresol for diagnosis of malignant hyperthermia susceptibility.
    European journal of anaesthesiology, 2003, Volume: 20, Issue:7

    Topics: Biopsy; Caffeine; Cresols; Disease Susceptibility; Halothane; Humans; In Vitro Techniques; Malignant

2003
Sensitivity of the Finometer device in detecting acute and medium-term changes in cardiovascular function.
    Blood pressure monitoring, 2003, Volume: 8, Issue:5

    Topics: Adolescent; Adult; Blood Pressure; Blood Pressure Determination; Caffeine; Central Nervous System St

2003
Effect of caffeine ingestion on exhaled nitric oxide measurements in patients with asthma.
    American journal of respiratory and critical care medicine, 2004, May-01, Volume: 169, Issue:9

    Topics: Administration, Oral; Adolescent; Adult; Aged; Analysis of Variance; Anti-Asthmatic Agents; Anti-Inf

2004
Enhanced stimulant and metabolic effects of combined ephedrine and caffeine.
    Clinical pharmacology and therapeutics, 2004, Volume: 75, Issue:4

    Topics: Adolescent; Adult; Area Under Curve; Biological Availability; Blood Pressure; Caffeine; Cardiovascul

2004
Effect of caffeine supplementation on haematological and biochemical variables in elite soccer players under physical stress conditions.
    British journal of sports medicine, 2007, Volume: 41, Issue:8

    Topics: Adult; Analysis of Variance; Anthropometry; Biomarkers; Blood Chemical Analysis; Caffeine; Creatine

2007
Effect of a pre-exercise energy supplement on the acute hormonal response to resistance exercise.
    Journal of strength and conditioning research, 2008, Volume: 22, Issue:3

    Topics: Adult; Amino Acids, Essential; Analysis of Variance; Area Under Curve; Blood Chemical Analysis; Caff

2008
Caffeine clearance study in hepatocellular carcinoma.
    Journal of the Medical Association of Thailand = Chotmaihet thangphaet, 1999, Volume: 82, Issue:3

    Topics: Adult; Aged; Caffeine; Carcinoma, Hepatocellular; Female; Humans; Liver; Liver Cirrhosis; Liver Func

1999
Effect of compound sequence on bitterness enhancement.
    Chemical senses, 2001, Volume: 26, Issue:4

    Topics: Administration, Oral; Adult; Area Under Curve; Caffeine; Drug Administration Schedule; Drug Interact

2001
Caffeine clearance in patients with chronic viral hepatitis: before and after interferon therapy.
    Journal of the Medical Association of Thailand = Chotmaihet thangphaet, 2001, Volume: 84 Suppl 1

    Topics: Administration, Oral; Adult; Caffeine; Chromatography, High Pressure Liquid; Female; Hepatitis B, Ch

2001
Prediction of malignant hyperthermia susceptibility in low-risk subjects. An epidemiologic investigation of caffeine halothane contracture responses. The North American Malignant Hyperthermia Registry.
    Anesthesiology, 1992, Volume: 76, Issue:1

    Topics: Adolescent; Adult; Aged; Biopsy; Caffeine; Child; Contracture; Disease Susceptibility; Female; Halot

1992

Other Studies

156 other studies available for caffeine and Sensitivity and Specificity

ArticleYear
Chemical genetics reveals a complex functional ground state of neural stem cells.
    Nature chemical biology, 2007, Volume: 3, Issue:5

    Topics: Animals; Cell Survival; Cells, Cultured; Mice; Molecular Structure; Neoplasms; Neurons; Pharmaceutic

2007
First-principle, structure-based prediction of hepatic metabolic clearance values in human.
    European journal of medicinal chemistry, 2009, Volume: 44, Issue:4

    Topics: Computational Biology; Drug Discovery; Hepatocytes; Humans; Hydrogen-Ion Concentration; Liver; Metab

2009
Different techniques for overlapped UV spectra resolution of some co-administered drugs with paracetamol in their combined pharmaceutical dosage forms.
    Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 2020, Jan-05, Volume: 224

    Topics: Acetaminophen; Caffeine; Diclofenac; Linear Models; Models, Chemical; Orphenadrine; Reproducibility

2020
Validation of an LC-MS/MS Method for the Quantification of Caffeine and Theobromine Using Non-Matched Matrix Calibration Curve.
    Molecules (Basel, Switzerland), 2019, Aug-07, Volume: 24, Issue:16

    Topics: Caffeine; Chromatography, Liquid; Humans; Reproducibility of Results; Sensitivity and Specificity; T

2019
Solvent and temperature effect of accelerated solvent extraction (ASE) coupled with ultra-high-pressure liquid chromatography (UHPLC-PDA) for the determination of methyl xanthines in commercial tea and coffee.
    Food chemistry, 2020, May-01, Volume: 311

    Topics: Caffeine; Chromatography, High Pressure Liquid; Coffee; Sensitivity and Specificity; Solvents; Tea;

2020
An improved cytochrome P450 phenotyping cocktail with a simplified and highly sensitive UHPLC-MS/MS assay in human plasma.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2020, Mar-01, Volume: 1140

    Topics: Biosensing Techniques; Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 Enzyme Syste

2020
Caffeine Delays Retinal Neurovascular Coupling during Dark to Light Adaptation in Healthy Eyes Revealed by Optical Coherence Tomography Angiography.
    Investigative ophthalmology & visual science, 2020, 04-09, Volume: 61, Issue:4

    Topics: Adaptation, Ocular; Adult; Age Factors; Caffeine; Dark Adaptation; Female; Fluorescein Angiography;

2020
Simultaneous Determination of Paracetamol, Propyphenazone and Caffeine in Presence of Paracetamol Impurities Using Dual-Mode Gradient HPLC and TLC Densitometry Methods.
    Journal of chromatographic science, 2021, Jan-14, Volume: 59, Issue:2

    Topics: Acetaminophen; Aminophenols; Antipyrine; Caffeine; Chromatography, High Pressure Liquid; Chromatogra

2021
Simultaneous quantification of caffeine and chlorogenic acid in coffee green beans and varietal classification of the samples by HPLC-DAD coupled with chemometrics.
    Environmental science and pollution research international, 2018, Volume: 25, Issue:29

    Topics: Caffeine; Chlorogenic Acid; Chromatography, High Pressure Liquid; Coffee; Least-Squares Analysis; Se

2018
Molecular imaging of the ATM kinase activity.
    International journal of radiation oncology, biology, physics, 2013, Aug-01, Volume: 86, Issue:5

    Topics: Animals; Ataxia Telangiectasia Mutated Proteins; Benzeneacetamides; Caffeine; Cell Cycle Proteins; C

2013
HPLC-DAD determination of seven antioxidants and caffeine in different phytopharmaceuticals.
    Journal of chromatographic science, 2014, Volume: 52, Issue:7

    Topics: Antioxidants; Caffeine; Camellia sinensis; Chromatography, High Pressure Liquid; Chromatography, Rev

2014
Caffeine monitoring in biological fluids by solid surface fluorescence using membranes modified with nanotubes.
    Clinica chimica acta; international journal of clinical chemistry, 2013, Oct-21, Volume: 425

    Topics: Caffeine; Calibration; Female; Filtration; Humans; Male; Membranes, Artificial; Nanotubes, Carbon; N

2013
Make caffeine visible: a fluorescent caffeine "traffic light" detector.
    Scientific reports, 2013, Volume: 3

    Topics: Biosensing Techniques; Caffeine; Fluorescent Dyes; Microfluidic Analytical Techniques; Nuclear Magne

2013
Xanthine derivatives quantification in serum by capillary zone electrophoresis.
    Journal of chromatographic science, 2014, Volume: 52, Issue:9

    Topics: Buffers; Caffeine; Electrophoresis, Capillary; Hydrogen-Ion Concentration; Limit of Detection; Repro

2014
Digitally enhanced thin layer chromatography: further development and some applications in isotopic chemistry.
    Journal of labelled compounds & radiopharmaceuticals, 2013, Volume: 56, Issue:11

    Topics: Anthraquinones; Caffeine; Carotenoids; Chromatography, Thin Layer; Image Processing, Computer-Assist

2013
Microclimate next to the skin: influence on percutaneous absorption of caffeine (ex-vivo study).
    Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI), 2014, Volume: 20, Issue:3

    Topics: Administration, Cutaneous; Adult; Air Conditioning; Caffeine; Ecosystem; Environment, Controlled; Eq

2014
Caffeine electrochemical sensor using imprinted film as recognition element based on polypyrrole, sol-gel, and gold nanoparticles hybrid nanocomposite modified pencil graphite electrode.
    Biosensors & bioelectronics, 2014, Oct-15, Volume: 60

    Topics: Caffeine; Conductometry; Electrodes; Equipment Design; Equipment Failure Analysis; Gold; Graphite; M

2014
Validation of caffeine dehydrogenase from Pseudomonas sp. strain CBB1 as a suitable enzyme for a rapid caffeine detection and potential diagnostic test.
    Journal of agricultural and food chemistry, 2014, Aug-06, Volume: 62, Issue:31

    Topics: Bacterial Proteins; Beverages; Caffeine; Food Analysis; Humans; Indicators and Reagents; Milk, Human

2014
Serum caffeine concentrations and short-term outcomes in premature infants of ⩽29 weeks of gestation.
    Journal of perinatology : official journal of the California Perinatal Association, 2015, Volume: 35, Issue:6

    Topics: Caffeine; Chronic Disease; Gestational Age; Hospital Charges; Humans; Infant, Premature; Length of S

2015
Analysis of caffeine and paraxanthine in human saliva with ultra-high-performance liquid chromatography for CYP1A2 phenotyping.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2015, Jul-15, Volume: 995-996

    Topics: Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 CYP1A2; Humans; Linear Models; Phen

2015
Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study.
    Analytica chimica acta, 2015, Jun-30, Volume: 881

    Topics: Blood Specimen Collection; Caffeine; Chromatography, Gas; Dried Blood Spot Testing; Healthy Voluntee

2015
Multiresidue determination of pesticides in tea by gas chromatography-tandem mass spectrometry.
    Journal of environmental science and health. Part. B, Pesticides, food contaminants, and agricultural wastes, 2015, Volume: 50, Issue:11

    Topics: Acetonitriles; Caffeine; Chemical Precipitation; Food Analysis; Food Contamination; Gas Chromatograp

2015
Caffeine does not significantly reduce the sensitivity of vasodilator stress MPI: Rebuttal.
    Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2016, Volume: 23, Issue:3

    Topics: Caffeine; Exercise Test; Myocardial Perfusion Imaging; Sensitivity and Specificity; Vasodilator Agen

2016
Caffeine reduces the sensitivity of vasodilator MPI for the detection of myocardial ischaemia: Pro.
    Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2016, Volume: 23, Issue:3

    Topics: Administration, Oral; Caffeine; Drug Interactions; Evidence-Based Medicine; Humans; Myocardial Ische

2016
Clinical associations with immature breathing in preterm infants: part 2-periodic breathing.
    Pediatric research, 2016, Volume: 80, Issue:1

    Topics: Caffeine; Cohort Studies; Electric Impedance; Enterocolitis, Necrotizing; Female; Gestational Age; H

2016
Biodosimetry for High-Dose Exposures Based on Dicentric Analysis in Lymphocytes Released from the G2-Block by Caffeine.
    Radiation protection dosimetry, 2016, Volume: 172, Issue:1-3

    Topics: Biological Assay; Caffeine; Cells, Cultured; Chromosome Aberrations; Cytogenetic Analysis; Dose-Resp

2016
Offline solid-phase extraction for preconcentration of pharmaceuticals and personal care products in environmental water and their simultaneous determination using the reversed phase high-performance liquid chromatography method.
    Environmental monitoring and assessment, 2016, Volume: 188, Issue:9

    Topics: Acetaminophen; Benzophenones; Caffeine; Carbanilides; Chromatography, High Pressure Liquid; Chromato

2016
The margin of internal exposure (MOIE) concept for dermal risk assessment based on oral toxicity data - A case study with caffeine.
    Toxicology, 2017, 12-01, Volume: 392

    Topics: Administration, Cutaneous; Administration, Oral; Animals; Caffeine; Calibration; Dose-Response Relat

2017
The automated, accurate and reproducible determination of steady-state permeation parameters from percutaneous permeation data.
    Alternatives to laboratory animals : ATLA, 2008, Volume: 36, Issue:2

    Topics: Animals; Automation; Caffeine; Cattle; Diffusion; Mammary Glands, Animal; Models, Biological; Permea

2008
A caffeine-sensitive membrane electrode: previous misleading report and present approach.
    Analytica chimica acta, 2008, Jul-14, Volume: 620, Issue:1-2

    Topics: Caffeine; Calibration; Chromatography, High Pressure Liquid; Electrodes; Hydrogen-Ion Concentration;

2008
Simple and rapid colorimetric detection of cofactors of aptazymes using noncrosslinking gold nanoparticle aggregation.
    Bioorganic & medicinal chemistry letters, 2008, Dec-15, Volume: 18, Issue:24

    Topics: Biosensing Techniques; Caffeine; Chemistry, Pharmaceutical; Colorimetry; Cross-Linking Reagents; DNA

2008
[Chromatographic determination of caffeine and its metabolites in saliva and plasma].
    Klinicheskaia laboratornaia diagnostika, 2008, Issue:10

    Topics: Caffeine; Chromatography, Liquid; Cytochrome P-450 CYP1A2; Cytochrome P-450 CYP2E1; Cytochrome P-450

2008
Application and analysis of structure-switching aptamers for small molecule quantification.
    Analytica chimica acta, 2009, Apr-13, Volume: 638, Issue:2

    Topics: Aptamers, Nucleotide; Biosensing Techniques; Caffeine; Nucleic Acid Conformation; Polymerase Chain R

2009
Silica nanoparticle-templated methacrylic acid monoliths for in-line solid-phase extraction-capillary electrophoresis of basic analytes.
    Journal of chromatography. A, 2009, Jun-19, Volume: 1216, Issue:25

    Topics: Beverages; Caffeine; Electrophoresis, Capillary; Humans; Ion Exchange; Methacrylates; Nanoparticles;

2009
Rapid qualitative and quantitative ultra high performance liquid chromatography method for simultaneous analysis of twenty nine common phenolic compounds of various structures.
    Talanta, 2010, Mar-15, Volume: 80, Issue:5

    Topics: Caffeine; Chromatography, High Pressure Liquid; Coumarins; Flavonoids; Phenols; Reproducibility of R

2010
A highly sensitive caffeine immunoassay based on a monoclonal antibody.
    Analytical and bioanalytical chemistry, 2010, Volume: 396, Issue:7

    Topics: Antibodies, Monoclonal; Caffeine; Food Analysis; Immunoassay; Reproducibility of Results; Sensitivit

2010
[Theanine, EGCG and caffeine determinated by HPLC].
    Wei sheng yan jiu = Journal of hygiene research, 2010, Volume: 39, Issue:1

    Topics: Caffeine; Catechin; Chromatography, High Pressure Liquid; Glutamates; Sensitivity and Specificity; T

2010
Dynamic modulation of detection window in conducting polymer based biosensors.
    Biosensors & bioelectronics, 2010, Jun-15, Volume: 25, Issue:10

    Topics: Biosensing Techniques; Caffeine; Conductometry; Equipment Design; Equipment Failure Analysis; Polyme

2010
Preparation of organic-inorganic hybrid silica monolith with octyl and sulfonic acid groups for capillary electrochromatograhpy and application in determination of theophylline and caffeine in beverage.
    Journal of chromatography. A, 2010, May-21, Volume: 1217, Issue:21

    Topics: Acetonitriles; Beverages; Caffeine; Capillary Electrochromatography; Electroosmosis; Food Analysis;

2010
Use of the caffeine-halothane contracture test for the diagnosis of malignant hyperthermia in Brazil.
    Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas, 2010, Volume: 43, Issue:6

    Topics: Adolescent; Adult; Aged; Anesthetics, Inhalation; Biopsy; Caffeine; Child; Child, Preschool; Contrac

2010
Development and validation of GC/MS method for determination of pramipexole in rat plasma.
    Biomedical chromatography : BMC, 2011, Volume: 25, Issue:4

    Topics: Animals; Benzothiazoles; Caffeine; Dopamine Agonists; Drug Stability; Gas Chromatography-Mass Spectr

2011
A simple chromatographic method for determining norfloxacin and enoxacin in pharmacokinetic study assessing CYP1A2 inhibition.
    Biomedical chromatography : BMC, 2011, Volume: 25, Issue:4

    Topics: Adult; Caffeine; Chromatography, High Pressure Liquid; Chromatography, Reverse-Phase; Cytochrome P-4

2011
Non-invasive measurement of oxygen saturation in the spinal vein using SWI: quantitative evaluation under conditions of physiological and caffeine load.
    NeuroImage, 2011, Jan-01, Volume: 54, Issue:1

    Topics: Adult; Caffeine; Female; Humans; Hyperventilation; Male; Oxygen; Reference Values; Respiratory Physi

2011
Rapid methods to determine procyanidins, anthocyanins, theobromine and caffeine in rat tissues by liquid chromatography-tandem mass spectrometry.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2011, Jun-01, Volume: 879, Issue:19

    Topics: Animals; Anthocyanins; Caffeine; Chromatography, High Pressure Liquid; Male; Proanthocyanidins; Rats

2011
Genotyping NAT2 with only two SNPs (rs1041983 and rs1801280) outperforms the tagging SNP rs1495741 and is equivalent to the conventional 7-SNP NAT2 genotype.
    Pharmacogenetics and genomics, 2011, Volume: 21, Issue:10

    Topics: Acetylation; Arylamine N-Acetyltransferase; Caffeine; Case-Control Studies; Ethnicity; Female; Genot

2011
High-temperature reversed-phase liquid chromatography coupled to isotope ratio mass spectrometry.
    Rapid communications in mass spectrometry : RCM, 2011, Oct-30, Volume: 25, Issue:20

    Topics: Caffeine; Carbon Dioxide; Carbon Isotopes; Chromatography, Reverse-Phase; Equipment Design; Hot Temp

2011
High-resolution mass spectrometry method for the detection, characterization and quantitation of pharmaceuticals in water.
    Journal of mass spectrometry : JMS, 2011, Volume: 46, Issue:11

    Topics: Caffeine; Chromatography, Liquid; Drinking Water; Drug Stability; Linear Models; Pharmaceutical Prep

2011
UPLC-MS-MS method for simultaneous determination of caffeine, tolbutamide, metoprolol, and dapsone in rat plasma and its application to cytochrome P450 activity study in rats.
    Journal of chromatographic science, 2013, Volume: 51, Issue:1

    Topics: Animals; Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 Enzyme System; Dapsone; Dr

2013
Fluorescence sensing of caffeine in aqueous solution with carbazole-based probe and imaging application in live cells.
    Bioorganic & medicinal chemistry letters, 2012, Sep-01, Volume: 22, Issue:17

    Topics: Caffeine; Candida albicans; Carbazoles; Cell Survival; Fluorescent Dyes; Microscopy, Fluorescence; M

2012
Determination of stimulants using gas chromatography/high-resolution time-of-flight mass spectrometry and a soft ionization source.
    Rapid communications in mass spectrometry : RCM, 2012, Dec-15, Volume: 26, Issue:23

    Topics: Caffeine; Central Nervous System Stimulants; Cocaine; Codeine; Dopamine Uptake Inhibitors; Equipment

2012
Quality assurance in immunoassay performance--comparison of different enzyme immunoassays for the determination of caffeine in consumer products.
    Analytical and bioanalytical chemistry, 2013, Volume: 405, Issue:5

    Topics: Alkaline Phosphatase; Animals; Antibodies, Monoclonal; Benzidines; Beverages; Caffeine; Chromatograp

2013
Vasoactive intestinal peptide-stimulated Cl- secretion: activation of cAMP-dependent K+ channels.
    The Journal of membrane biology, 2002, Apr-01, Volume: 186, Issue:3

    Topics: Caffeine; Cell Line; Chlorides; Cyclic AMP-Dependent Protein Kinases; Electric Conductivity; Humans;

2002
Reproducibility of in vitro contracture test results in patients tested for malignant hyperthermia susceptibility.
    Acta anaesthesiologica Scandinavica, 2002, Volume: 46, Issue:9

    Topics: Adult; Anesthetics, Inhalation; Biopsy; Caffeine; Disease Susceptibility; Female; Halothane; Humans;

2002
A biosensor for theophylline based on fluorescence detection of ligand-induced hammerhead ribozyme cleavage.
    RNA (New York, N.Y.), 2002, Volume: 8, Issue:10

    Topics: Base Pairing; Base Sequence; Binding Sites; Biosensing Techniques; Caffeine; Fluorescence Resonance

2002
Determination of caffeine as a tracer of sewage effluent in natural waters by on-line solid-phase extraction and liquid chromatography with diode-array detection.
    Water research, 2002, Volume: 36, Issue:19

    Topics: Automation; Caffeine; Central Nervous System Stimulants; Chromatography, High Pressure Liquid; Envir

2002
Trace determination of caffeine in surface water samples by liquid chromatography--atmospheric pressure chemical ionization--mass spectrometry (LC-APCI-MS).
    Environment international, 2002, Volume: 28, Issue:6

    Topics: Atmospheric Pressure; Caffeine; Central Nervous System Stimulants; Chromatography, Liquid; Environme

2002
Inhibitory effects of tea and caffeine on UV-induced carcinogenesis: relationship to enhanced apoptosis and decreased tissue fat.
    European journal of cancer prevention : the official journal of the European Cancer Prevention Organisation (ECP), 2002, Volume: 11 Suppl 2

    Topics: Adipose Tissue; Administration, Oral; Administration, Topical; Animals; Anticarcinogenic Agents; Apo

2002
Analysis of adulterants in a traditional herbal medicinal product using liquid chromatography-mass spectrometry-mass spectrometry.
    Journal of pharmaceutical and biomedical analysis, 2003, Feb-26, Volume: 31, Issue:2

    Topics: Caffeine; Chromatography, Liquid; Drug Contamination; Herbal Medicine; Mass Spectrometry; Oxyphenbut

2003
Caffeine clearance in patients with hepatocellular carcinoma after transcatheter oily chemoembolization treatment.
    Journal of the Medical Association of Thailand = Chotmaihet thangphaet, 2002, Volume: 85, Issue:12

    Topics: Adult; Aged; Analysis of Variance; Caffeine; Carcinoma, Hepatocellular; Chemoembolization, Therapeut

2002
Extractionless method for the determination of urinary caffeine metabolites using high-performance liquid chromatography coupled with tandem mass spectrometry.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2003, Jun-15, Volume: 789, Issue:2

    Topics: Caffeine; Chromatography, High Pressure Liquid; Humans; Reference Standards; Sensitivity and Specifi

2003
[Research into simultaneous spectrophotometric determination of components in cough syrup by principal component regression method].
    Guang pu xue yu guang pu fen xi = Guang pu, 2002, Volume: 22, Issue:3

    Topics: Acetaminophen; Aminophenols; Analgesics, Non-Narcotic; Caffeine; Chlorpheniramine; Drug Combinations

2002
[Assay for paracetamol by derivative spectrophotometry in compound amantadine tablets].
    Guang pu xue yu guang pu fen xi = Guang pu, 2002, Volume: 22, Issue:4

    Topics: Acetaminophen; Amantadine; Antiviral Agents; Caffeine; Drug Combinations; Pharmaceutical Preparation

2002
[Determination of naoning pian by multi-wavelength linear regression method].
    Guang pu xue yu guang pu fen xi = Guang pu, 2001, Volume: 21, Issue:6

    Topics: Analgesics, Non-Narcotic; Antipyrine; Caffeine; Drug Combinations; Linear Models; Pharmaceutical Pre

2001
A rapid high-performance liquid chromatographic method for the simultaneous quantitation of aspirin, salicylic acid, and caffeine in effervescent tablets.
    Journal of chromatographic science, 2003, Volume: 41, Issue:8

    Topics: Aspirin; Caffeine; Chromatography, High Pressure Liquid; Reference Standards; Reproducibility of Res

2003
Sequential injection chromatographic determination of paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets.
    Journal of separation science, 2004, Volume: 27, Issue:7-8

    Topics: Acetaminophen; Aspirin; Caffeine; Chromatography; Indicators and Reagents; Sensitivity and Specifici

2004
A simplified analytical method for a phenotyping cocktail of major CYP450 biotransformation routes.
    Journal of pharmaceutical and biomedical analysis, 2004, Sep-03, Volume: 35, Issue:5

    Topics: Biotransformation; Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 Enzyme System; D

2004
Simultaneous determination of caffeine, theophylline and theobromine in human plasma by on-line solid-phase extraction coupled to reversed-phase chromatography.
    Biomedical chromatography : BMC, 2004, Volume: 18, Issue:8

    Topics: Buffers; Caffeine; Chromatography, High Pressure Liquid; Humans; Hydrogen-Ion Concentration; Methano

2004
Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometry.
    Journal of the American Society for Mass Spectrometry, 2004, Volume: 15, Issue:10

    Topics: Caffeine; Models, Chemical; Reserpine; Sensitivity and Specificity; Spectrometry, Mass, Electrospray

2004
Separation, pre-concentration, and HPLC analysis of methylxanthines in urine samples.
    Journal of separation science, 2004, Volume: 27, Issue:14

    Topics: Caffeine; Calibration; Chromatography, High Pressure Liquid; Humans; Molecular Structure; Reproducib

2004
Monitoring bronchodilators with direct injection.
    Journal of chromatography. A, 2005, May-06, Volume: 1073, Issue:1-2

    Topics: Bronchodilator Agents; Caffeine; Calibration; Chromatography, Liquid; Humans; Reproducibility of Res

2005
[Determination of catechins and caffeine in tea and tea beverages by high-performance liquid chromatography].
    Wei sheng yan jiu = Journal of hygiene research, 2005, Volume: 34, Issue:2

    Topics: Caffeine; Camellia sinensis; Catechin; Chromatography, High Pressure Liquid; Sensitivity and Specifi

2005
Stir bar sorptive extraction based on restricted access material for the direct extraction of caffeine and metabolites in biological fluids.
    Journal of chromatography. A, 2005, May-20, Volume: 1075, Issue:1-2

    Topics: Caffeine; Chromatography, High Pressure Liquid; Humans; Reproducibility of Results; Sensitivity and

2005
Content uniformity and dissolution tests of triplicate mixtures by a double divisor-ratio spectra derivative method.
    Farmaco (Societa chimica italiana : 1989), 2005, Volume: 60, Issue:9

    Topics: Acetaminophen; Aspirin; Caffeine; Chlorpheniramine; Chromatography, High Pressure Liquid; Reproducib

2005
Advanced oxidation of caffeine in water: on-line and real-time monitoring by electrospray ionization mass spectrometry.
    Environmental science & technology, 2005, Aug-15, Volume: 39, Issue:16

    Topics: Automation; Caffeine; Chromatography, High Pressure Liquid; Environmental Monitoring; Gas Chromatogr

2005
Polyphenol levels in human urine after intake of six different polyphenol-rich beverages.
    The British journal of nutrition, 2005, Volume: 94, Issue:4

    Topics: Adult; Beverages; Biomarkers; Cacao; Caffeine; Calibration; Case-Control Studies; Chromatography, Hi

2005
Separation of caffeine and theophylline in poly(dimethylsiloxane) microchannel electrophoresis with electrochemical detection.
    Journal of chromatography. A, 2005, Dec-09, Volume: 1098, Issue:1-2

    Topics: Animals; Caffeine; Dimethylpolysiloxanes; Electrochemistry; Electrophoresis, Capillary; Hydrogen-Ion

2005
Off-line direct deposition gas chromatography/surface-enhanced Raman scattering and the ramifications for on-line measurements.
    Applied spectroscopy, 2005, Volume: 59, Issue:11

    Topics: Caffeine; Chromatography, Gas; Computer Systems; Microchemistry; Online Systems; Phenols; Reproducib

2005
Heritability and genetic covariation of sensitivity to PROP, SOA, quinine HCl, and caffeine.
    Chemical senses, 2006, Volume: 31, Issue:5

    Topics: Adolescent; Adult; Caffeine; Child; Female; Genetic Variation; Humans; Inheritance Patterns; Male; M

2006
Determination of acidic drugs and caffeine in municipal wastewaters and receiving waters by gas chromatography-ion trap tandem mass spectrometry.
    Journal of chromatography. A, 2006, May-26, Volume: 1116, Issue:1-2

    Topics: Acids; Caffeine; Calibration; Gas Chromatography-Mass Spectrometry; Pharmaceutical Preparations; Ref

2006
A simple webcam-based approach for the measurement of rodent locomotion and other behavioural parameters.
    Journal of neuroscience methods, 2006, Oct-15, Volume: 157, Issue:1

    Topics: Algorithms; Amphetamine; Animals; Behavior, Animal; Caffeine; Central Nervous System Stimulants; Diz

2006
Reliability of total overnight salivary caffeine assessment (TOSCA) for liver function evaluation in compensated cirrhotic patients.
    European journal of clinical pharmacology, 2006, Volume: 62, Issue:8

    Topics: Adult; Caffeine; Case-Control Studies; Chromatography, High Pressure Liquid; Humans; Liver Cirrhosis

2006
Development of a multicommuted flow-through optosensor for the determination of a ternary pharmaceutical mixture.
    Journal of pharmaceutical and biomedical analysis, 2007, Jan-17, Volume: 43, Issue:2

    Topics: Antipyrine; Buffers; Caffeine; Flow Injection Analysis; Methanol; Pharmaceutical Preparations; Repro

2007
In vivo evaluation of CYP1A2, CYP2A6, NAT-2 and xanthine oxidase activities in a Greek population sample by the RP-HPLC monitoring of caffeine metabolic ratios.
    Biomedical chromatography : BMC, 2007, Volume: 21, Issue:2

    Topics: Adult; Aryl Hydrocarbon Hydroxylases; Arylamine N-Acetyltransferase; Caffeine; Chromatography, High

2007
A preliminary investigation into the use of biosensors to screen stomach contents for selected poisons and drugs.
    Forensic science international, 2007, Oct-25, Volume: 172, Issue:2-3

    Topics: Biosensing Techniques; Caffeine; Escherichia coli; Forensic Pathology; Gastrointestinal Contents; Hu

2007
Stereospecific determination of cis- and trans-resveratrol in rat plasma by HPLC: application to pharmacokinetic studies.
    Biomedical chromatography : BMC, 2007, Volume: 21, Issue:3

    Topics: Animals; Caffeine; Calibration; Chromatography, High Pressure Liquid; Drug Stability; Molecular Stru

2007
Development of a biosensor for caffeine.
    Analytica chimica acta, 2007, Jan-23, Volume: 582, Issue:2

    Topics: Biosensing Techniques; Caffeine; Calibration; Chromatography, High Pressure Liquid; Enzymes, Immobil

2007
Investigation of the advanced functionalities of a hybrid quadrupole orthogonal acceleration time-of-flight mass spectrometer.
    Rapid communications in mass spectrometry : RCM, 2007, Volume: 21, Issue:15

    Topics: Caffeine; Pharmaceutical Preparations; Reproducibility of Results; Reserpine; Sensitivity and Specif

2007
Liquid chromatography/electrospray ionization tandem mass spectrometry assay for determination of nicotine and metabolites, caffeine and arecoline in breast milk.
    Rapid communications in mass spectrometry : RCM, 2007, Volume: 21, Issue:16

    Topics: Arecoline; Caffeine; Chromatography, High Pressure Liquid; Humans; Milk, Human; Nicotine; Reproducib

2007
Determination of caffeine in coffee products by dynamic complexation with 3,4-dimethoxycinnamate and separation by CZE.
    Electrophoresis, 2007, Volume: 28, Issue:19

    Topics: Anions; Beverages; Binding Sites; Caffeine; Chlorogenic Acid; Cinnamates; Coffee; Electric Conductiv

2007
An improved application for the enzyme multipled immunoassay technique for caffeine, amikacin, and methotrexate assays on the Dade-Behring Dimension RxL Max clinical chemistry system.
    Therapeutic drug monitoring, 2007, Volume: 29, Issue:5

    Topics: Amikacin; Anti-Bacterial Agents; Antimetabolites, Antineoplastic; Caffeine; Central Nervous System S

2007
Rapid determination of caffeine in one drop of beverages and foods using drop-to-drop solvent microextraction with gas chromatography/mass spectrometry.
    Journal of chromatography. A, 2007, Nov-02, Volume: 1170, Issue:1-2

    Topics: Beverages; Caffeine; Calibration; Chemical Fractionation; Chloroform; Food Analysis; Gas Chromatogra

2007
Changes in sensitivity of response distributions to changing reinforcement ratios during exposure to ephedrine, caffeine, and ephedrine-caffeine combinations.
    Behavioural pharmacology, 2007, Volume: 18, Issue:7

    Topics: Analysis of Variance; Animals; Behavior, Animal; Caffeine; Central Nervous System Stimulants; Condit

2007
Is electrogustometry useful for screening abnormalities of taste?
    The Journal of laryngology and otology, 2007, Volume: 121, Issue:12

    Topics: Adult; Aged; Aged, 80 and over; Caffeine; Citric Acid; Electrodiagnosis; Female; Humans; Male; Mass

2007
Quasi-flow injection analysis for rapid determination of caffeine in tea using the sample pre-treatment method with a cartridge column filled with polyvinylpolypyrrolidone.
    Journal of chromatography. A, 2008, Jan-04, Volume: 1177, Issue:1

    Topics: Caffeine; Chromatography, High Pressure Liquid; Flow Injection Analysis; Povidone; Reference Standar

2008
Assessing caffeine exposure in pregnant women.
    The British journal of nutrition, 2008, Volume: 100, Issue:4

    Topics: Adult; Biomarkers; Caffeine; Diet Records; Feeding Behavior; Female; Humans; Pregnancy; Pregnancy Ou

2008
The delta isomer of hexachlorocyclohexane induces rapid release of the myo-inositol-1,4,5-trisphosphate-sensitive Ca2+ store and blocks capacitative Ca2+ entry in rat basophilic leukemia cells.
    Molecular pharmacology, 1995, Volume: 48, Issue:3

    Topics: Adenosine Triphosphate; Animals; Antigens; Binding, Competitive; Caffeine; Calcium; Calcium-Transpor

1995
A method for the separation of delta bilirubin using Cibacron Blue affinity chromatography.
    Clinica chimica acta; international journal of clinical chemistry, 1995, Jul-31, Volume: 239, Issue:1

    Topics: Adult; Benzoates; Bilirubin; Caffeine; Chromatography, Affinity; Chromatography, High Pressure Liqui

1995
Testing vigilance: validity, reliability and sensitivity in methods development.
    Psychopharmacology, 1995, Volume: 118, Issue:2

    Topics: Attention; Caffeine; Diphenhydramine; Humans; Reproducibility of Results; Research Design; Sensitivi

1995
Highly sensitive and rapid determination of theophylline, theobromine and caffeine in human plasma and urine by gradient capillary high-performance liquid chromatography-frit-fast atom bombardment mass spectrometry.
    Journal of chromatography. B, Biomedical applications, 1995, May-19, Volume: 667, Issue:2

    Topics: Caffeine; Capillary Action; Chromatography, High Pressure Liquid; Humans; Reproducibility of Results

1995
Rapid high-performance liquid chromatographic determination of vancomycin in human plasma.
    Journal of chromatography. B, Biomedical applications, 1995, May-19, Volume: 667, Issue:2

    Topics: Acetaminophen; Aspirin; Caffeine; Chromatography, High Pressure Liquid; Humans; Quality Control; Sen

1995
Thapsigargin-sensitive Ca(2+)-ATPases account for Ca2+ uptake to inositol 1,4,5-trisphosphate-sensitive and caffeine-sensitive Ca2+ stores in adrenal chromaffin cells.
    The Biochemical journal, 1995, May-01, Volume: 307 ( Pt 3)

    Topics: Adrenal Medulla; Animals; Caffeine; Calcium; Calcium Channels; Calcium-Transporting ATPases; Cattle;

1995
Application of an enzyme-multiplied immunoassay technique for determination of caffeine elimination kinetics as a test of liver function in clinically normal dogs.
    American journal of veterinary research, 1994, Volume: 55, Issue:6

    Topics: Administration, Oral; Animals; Caffeine; Dogs; Enzyme Multiplied Immunoassay Technique; Evaluation S

1994
Inhibitory effects of caffeine on secretagogue-induced catecholamine secretion from adrenal chromaffin cells of the guinea-pig.
    British journal of pharmacology, 1994, Volume: 111, Issue:3

    Topics: 8-Bromo Cyclic Adenosine Monophosphate; Acetylcholine; Adrenal Glands; Animals; Bucladesine; Caffein

1994
Determination of ten beta-blockers in urine by micellar electrokinetic capillary chromatography.
    Journal of chromatography, 1993, Feb-19, Volume: 632, Issue:1-2

    Topics: Adrenergic beta-Antagonists; Caffeine; Chromatography; Gas Chromatography-Mass Spectrometry; Humans;

1993
Different fates of camptothecin-induced replication fork-associated double-strand DNA breaks in mammalian cells.
    Carcinogenesis, 1994, Volume: 15, Issue:5

    Topics: Animals; Caffeine; Camptothecin; Cell Line; CHO Cells; Chromosome Aberrations; Cricetinae; DNA; DNA

1994
Caffeine withdrawal: apparent heterologous sensitization to adenosine and prostacyclin actions in human platelets.
    The Journal of pharmacology and experimental therapeutics, 1993, Volume: 267, Issue:2

    Topics: Adenosine; Adenosine-5'-(N-ethylcarboxamide); Adolescent; Adult; Alprostadil; Blood Platelets; Caffe

1993
Tolerance to the behavioral effects of chlordiazepoxide: pharmacological and biochemical selectivity.
    The Journal of pharmacology and experimental therapeutics, 1993, Volume: 267, Issue:3

    Topics: Amphetamine; Animals; Behavior, Animal; Caffeine; Carbolines; Chlordiazepoxide; Chlorides; Chlorine;

1993
Age-related abnormalities in regulation of the ryanodine receptor in rat fast-twitch muscle.
    Cell calcium, 1996, Volume: 19, Issue:1

    Topics: Aging; Animals; Antibiotics, Antineoplastic; Binding Sites; Caffeine; Calcium; Calcium Channel Block

1996
Calcium signalling in granule neurones studied in cerebellar slices.
    Cell calcium, 1996, Volume: 19, Issue:1

    Topics: Acetylcholine; Age Factors; Animals; Animals, Newborn; Caffeine; Calcium; Calcium Channel Agonists;

1996
Simultaneous high-performance liquid chromatographic determination of caffeine and theophylline for routine drug monitoring in human plasma.
    Journal of chromatography. B, Biomedical applications, 1996, Mar-03, Volume: 677, Issue:2

    Topics: Caffeine; Chromatography, High Pressure Liquid; Humans; Reference Standards; Reproducibility of Resu

1996
In vitro human masseter muscle hypersensitivity: a possible explanation for increase in masseter tone.
    Journal of applied physiology (Bethesda, Md. : 1985), 1996, Volume: 80, Issue:5

    Topics: Caffeine; Calcium; Humans; In Vitro Techniques; Masseter Muscle; Muscle Contraction; Muscle Fibers,

1996
Ryanodine-sensitive component of calcium transients evoked by nerve firing at presynaptic nerve terminals.
    The Journal of neuroscience : the official journal of the Society for Neuroscience, 1996, Nov-01, Volume: 16, Issue:21

    Topics: Animals; Caffeine; Calcium; Calcium Channel Blockers; Calcium Channels; Central Nervous System Stimu

1996
Hypogravity increases cyclopiazonic acid sensitivity of rat soleus muscle.
    Journal of applied physiology (Bethesda, Md. : 1985), 1996, Volume: 80, Issue:4

    Topics: Animals; Caffeine; Dose-Response Relationship, Drug; Enzyme Inhibitors; Hypogravity; Indoles; Male;

1996
Threshold level for theophylline in doping analysis.
    Journal of chromatography. B, Biomedical applications, 1996, Dec-06, Volume: 687, Issue:1

    Topics: Caffeine; Chromatography, High Pressure Liquid; Doping in Sports; Humans; Male; Reproducibility of R

1996
Rapid, simple and sensitive microassay for skeletal muscle homogenates in the functional assessment of the Ca-release channel of sarcoplasmic reticulum: application to diagnosis of susceptibility to malignant hyperthermia.
    Molecular and cellular biochemistry, 1997, Volume: 167, Issue:1-2

    Topics: Animals; Caffeine; Calcium; Calcium Channels; Calcium-Transporting ATPases; Disease Models, Animal;

1997
Caffeine urinary metabolite ratios as markers of enzyme activity: a theoretical assessment.
    Pharmacogenetics, 1996, Volume: 6, Issue:2

    Topics: Arylamine N-Acetyltransferase; Biomarkers; Caffeine; Computer Simulation; Cytochrome P-450 CYP1A2; D

1996
Classification of malignant hyperthermia-equivocal patients by 4-chloro-M-cresol.
    Anesthesia and analgesia, 1997, Volume: 85, Issue:1

    Topics: Adolescent; Adult; Aged; Anesthetics, Inhalation; Caffeine; Cresols; Disease Susceptibility; Dose-Re

1997
Separation of the N-7 methyltransferase, the key enzyme in caffeine biosynthesis.
    Phytochemistry, 1997, Volume: 45, Issue:7

    Topics: Affinity Labels; Caffeine; Chromatography, Affinity; Coffee; Methyltransferases; Plant Extracts; Pla

1997
Interlocking structural motifs mediate molecular discrimination by a theophylline-binding RNA.
    Nature structural biology, 1997, Volume: 4, Issue:8

    Topics: Bronchodilator Agents; Caffeine; Cytosine; Magnetic Resonance Spectroscopy; Models, Molecular; Molec

1997
In vitro contracture test for diagnosis of malignant hyperthermia following the protocol of the European MH Group: results of testing patients surviving fulminant MH and unrelated low-risk subjects. The European Malignant Hyperthermia Group.
    Acta anaesthesiologica Scandinavica, 1997, Volume: 41, Issue:8

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Anesthesia; Biopsy; Caffeine; Child; Child, Preschool; F

1997
2APB, 2-aminoethoxydiphenyl borate, a membrane-penetrable modulator of Ins(1,4,5)P3-induced Ca2+ release.
    Journal of biochemistry, 1997, Volume: 122, Issue:3

    Topics: Animals; Aorta, Thoracic; Blood Platelets; Boron Compounds; Caffeine; Calcium; Calcium Channels; Cel

1997
The Israeli Diagnostic Center for Malignant Hyperthermia: 7-years' accumulated experience.
    Israel journal of medical sciences, 1997, Volume: 33, Issue:10

    Topics: Academies and Institutes; Adult; Aged; Biopsy; Caffeine; Child; Electromyography; Female; Genetic Pr

1997
Discordance between malignant hyperthermia susceptibility and RYR1 mutation C1840T in two Scandinavian MH families exhibiting this mutation.
    Clinical genetics, 1997, Volume: 52, Issue:6

    Topics: Anesthesia; Caffeine; Denmark; Female; Genetic Predisposition to Disease; Halothane; Humans; Male; M

1997
Subnanomolar quantification of caffeine's in vitro metabolites by stable isotope dilution gas chromatography-mass spectrometry.
    Journal of chromatography. B, Biomedical sciences and applications, 1998, Apr-24, Volume: 708, Issue:1-2

    Topics: Caffeine; Chromatography, High Pressure Liquid; Gas Chromatography-Mass Spectrometry; Humans; In Vit

1998
Economic evaluation of oral sumatriptan compared with oral caffeine/ergotamine for migraine.
    PharmacoEconomics, 1997, Volume: 12, Issue:5

    Topics: Administration, Oral; Caffeine; Cost-Benefit Analysis; Ergotamine; Migraine Disorders; Sensitivity a

1997
Comparison between the European and North American protocols for diagnosis of malignant hyperthermia susceptibility in humans.
    Anesthesia and analgesia, 1999, Volume: 88, Issue:5

    Topics: Caffeine; Halothane; Humans; Malignant Hyperthermia; Muscle Contraction; Sensitivity and Specificity

1999
High-performance liquid chromatographic method for simultaneous determination of [1-methyl-14C]caffeine and its eight major metabolites in rat urine.
    Journal of chromatography. B, Biomedical sciences and applications, 1999, Apr-16, Volume: 726, Issue:1-2

    Topics: Animals; Caffeine; Carbon Radioisotopes; Chromatography, High Pressure Liquid; Cytochrome P-450 Enzy

1999
Use of caffeine as a probe for rapid determination of cytochrome P-450 CYP1A2 activity in humans.
    Zhongguo yao li xue bao = Acta pharmacologica Sinica, 1998, Volume: 19, Issue:1

    Topics: Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 CYP1A2; Humans; Sensitivity and Spe

1998
Validation of a high-performance liquid chromatography assay for quantification of caffeine and paraxanthine in human serum in the context of CYP1A2 phenotyping.
    Biomedical chromatography : BMC, 1999, Volume: 13, Issue:4

    Topics: Caffeine; Chromatography, High Pressure Liquid; Cytochrome P-450 CYP1A2; Humans; Phenotype; Reproduc

1999
[Caffeine skinned fiber tension test: application to the diagnosis of susceptibility to malignant hyperthermia].
    Annales francaises d'anesthesie et de reanimation, 1999, Volume: 18, Issue:6

    Topics: Caffeine; Disease Susceptibility; Humans; In Vitro Techniques; Malignant Hyperthermia; Muscle Contra

1999
Determination of a 'GW cocktail' of cytochrome P450 probe substrates and their metabolites in plasma and urine using automated solid phase extraction and fast gradient liquid chromatography tandem mass spectrometry.
    Rapid communications in mass spectrometry : RCM, 1999, Volume: 13, Issue:23

    Topics: Automation; Caffeine; Chlorzoxazone; Chromatography, Gas; Chromatography, High Pressure Liquid; Cyto

1999
Quantitation of caffeine by capillary zone electrophoresis with end-column amperometric detection at a carbon microdisk array electrode.
    Journal of chromatographic science, 2000, Volume: 38, Issue:1

    Topics: Beverages; Caffeine; Carbon; Electrodes; Electrophoresis, Capillary; Humans; Hydrogen-Ion Concentrat

2000
Simultaneous determination of paracetamol, caffeine and acetylsalicylic acid by means of a FI ultraviolet pls multioptosensing device.
    Journal of pharmaceutical and biomedical analysis, 1999, Volume: 21, Issue:5

    Topics: Acetaminophen; Aspirin; Caffeine; Electronic Data Processing; Flow Injection Analysis; Hydrogen-Ion

1999
Study of a molecular imprinting polymer coated BAW bio-mimic sensor and its application to the determination of caffeine in human serum and urine.
    The Analyst, 1999, Volume: 124, Issue:12

    Topics: Biosensing Techniques; Caffeine; Humans; Sensitivity and Specificity

1999
On-line coupling of subcritical water extraction with high-performance liquid chromatography via solid-phase trapping.
    Journal of chromatography. A, 2000, Mar-24, Volume: 873, Issue:2

    Topics: Aniline Compounds; Caffeine; Chlorophenols; Chromatography, High Pressure Liquid; Polychlorinated Bi

2000
A high-performance liquid chromatography assay for yohimbine HCl analysis.
    Drug development and industrial pharmacy, 2000, Volume: 26, Issue:10

    Topics: Adrenergic alpha-Antagonists; Caffeine; Calibration; Central Nervous System Stimulants; Hot Temperat

2000
Liquid chromatographic method for the simultaneous determination of caffeine and fourteen caffeine metabolites in urine.
    Journal of chromatography. B, Biomedical sciences and applications, 2000, Sep-15, Volume: 746, Issue:2

    Topics: Adult; Aged; Caffeine; Chromatography, High Pressure Liquid; Female; Humans; Male; Middle Aged; Refe

2000
Surfactants usable for electrospray ionization mass spectrometry.
    Analytical biochemistry, 2000, Dec-01, Volume: 287, Issue:1

    Topics: Adrenergic beta-Antagonists; Alkanesulfonic Acids; Caffeine; Caprylates; Chromatography, High Pressu

2000
Development of an automated on-line solid-phase extraction-high-performance liquid chromatographic method for the analysis of aniline, phenol, caffeine and various selected substituted aniline and phenol compounds in aqueous matrices.
    Journal of chromatography. A, 2000, Dec-29, Volume: 904, Issue:2

    Topics: Aniline Compounds; Automation; Caffeine; Chromatography, High Pressure Liquid; Electrochemistry; Phe

2000
Fourier transform infrared determination of caffeine in roasted coffee samples.
    Fresenius' journal of analytical chemistry, 2000, Volume: 366, Issue:3

    Topics: Ammonia; Caffeine; Coffee; Food Handling; Indicators and Reagents; Reproducibility of Results; Sensi

2000
Loss of G2/M arrest correlates with radiosensitization in two human sarcoma cell lines with mutant p53.
    International journal of cancer, 2001, Apr-20, Volume: 96, Issue:2

    Topics: Adenocarcinoma; Alleles; Apoptosis; Blotting, Western; Caffeine; Cell Survival; Combined Modality Th

2001
Misclassification of exposure: coffee as a surrogate for caffeine intake.
    American journal of epidemiology, 2001, Apr-15, Volume: 153, Issue:8

    Topics: Adult; Aged; Caffeine; Central Nervous System Stimulants; Coffee; Diet; Environmental Exposure; Epid

2001
Fluorescence quenching high-performance thin-layer chromatographic analysis utilizing a scientifically operated charge-coupled device detector.
    The Analyst, 2001, Volume: 126, Issue:4

    Topics: Acetaminophen; Aspirin; Autoanalysis; Caffeine; Chromatography, High Pressure Liquid; Chromatography

2001
A simple high-pressure liquid chromatography cotinine assay: validation of smoking status in pregnant women.
    Annals of clinical biochemistry, 2001, Volume: 38, Issue:Pt 4

    Topics: Biomarkers; Caffeine; Chromatography, High Pressure Liquid; Coffee; Cotinine; Creatinine; Female; Hu

2001
Use of novel solid-phase extraction sorbent materials for high-performance liquid chromatography quantitation of caffeine metabolism products methylxanthines and methyluric acids in samples of biological origin.
    Journal of chromatography. B, Biomedical sciences and applications, 2001, Aug-15, Volume: 759, Issue:2

    Topics: Caffeine; Chromatography, High Pressure Liquid; Humans; Reproducibility of Results; Sensitivity and

2001
Improved high-performance liquid chromatography method to determine theobromine and caffeine in cocoa and cocoa products.
    Journal of agricultural and food chemistry, 2001, Volume: 49, Issue:8

    Topics: Cacao; Caffeine; Chromatography, High Pressure Liquid; Sensitivity and Specificity; Theobromine; Tim

2001
Testing for malignant hyperthermia.
    Anesthesiology, 2002, Volume: 96, Issue:1

    Topics: Anesthesia; Biopsy; Caffeine; Halothane; Humans; Malignant Hyperthermia; Muscle Contraction; Sensiti

2002
Use of an automated on-line SPE-HPLC method to monitor caffeine and selected aniline and phenol compounds in aquatic systems of Macedonia-Thrace, Greece.
    Fresenius' journal of analytical chemistry, 2001, Volume: 371, Issue:4

    Topics: Aniline Compounds; Caffeine; Chromatography, High Pressure Liquid; Electrochemistry; Gas Chromatogra

2001
Simultaneous determination of caffeine, theobromine, and theophylline by high-performance liquid chromatography.
    Journal of chromatographic science, 2002, Volume: 40, Issue:1

    Topics: Beverages; Caffeine; Calibration; Chromatography, High Pressure Liquid; Sensitivity and Specificity;

2002
Functional and fluorochrome analysis of an exocytotic mutant yields evidence of store-operated Ca2+ influx in Paramecium.
    The Journal of membrane biology, 2002, May-01, Volume: 187, Issue:1

    Topics: Animals; Caffeine; Calcium; Calcium Channels; Cell Line; Cresols; Dextrans; Exocytosis; Fluorescent

2002
Differential activation by Ca2+, ATP and caffeine of cardiac and skeletal muscle ryanodine receptors after block by Mg2+.
    The Journal of membrane biology, 2002, May-01, Volume: 187, Issue:1

    Topics: Adenosine Triphosphate; Animals; Caffeine; Calcium; Dogs; In Vitro Techniques; Magnesium; Muscle, Sk

2002
Enhanced cytogenetic detection of previous in vivo exposure to mutagens in human lymphocytes after treatment with inhibitors of DNA synthesis and DNA repair in vitro.
    Mutation research, 1992, Volume: 271, Issue:3

    Topics: Adult; Caffeine; Cells, Cultured; Chromosome Aberrations; DNA Repair; DNA Replication; Humans; Hydro

1992
Sources of variability in halothane and caffeine contracture tests for susceptibility to malignant hyperthermia.
    European journal of anaesthesiology, 1992, Volume: 9, Issue:5

    Topics: Adolescent; Adult; Aged; Caffeine; Child; Contracture; Dose-Response Relationship, Drug; Female; Hal

1992
Sensitivity of transmission probabilities to paternity exclusion in segregation analysis.
    Genetic epidemiology, 1992, Volume: 9, Issue:1

    Topics: Acetyltransferases; Caffeine; Family Health; Genetic Carrier Screening; Humans; Meiosis; Paternity;

1992
Spatial and dynamic changes in intracellular Ca2+ measured by confocal laser-scanning microscopy in bullfrog sympathetic ganglion cells.
    Neuroscience research, 1991, Volume: 10, Issue:4

    Topics: Aniline Compounds; Animals; Anura; Caffeine; Calcium; Electric Stimulation; Fluorescent Dyes; Gangli

1991
Rapid and sensitive gas-chromatographic determination of caffeine in blood plasma, saliva, and xanthine beverages.
    Molecular biology reports, 1991, Volume: 15, Issue:1

    Topics: Adult; Beverages; Caffeine; Chromatography, Gas; Humans; Male; Reference Standards; Reproducibility

1991