Page last updated: 2024-08-21

c.i. 42510 and Proteinuria

c.i. 42510 has been researched along with Proteinuria in 44 studies

Research

Studies (44)

TimeframeStudies, this research(%)All Research%
pre-199028 (63.64)18.7374
1990's13 (29.55)18.2507
2000's1 (2.27)29.6817
2010's2 (4.55)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Bai, B; Jia, J; Pan, J; Wang, S; Xu, H1
Bigot-Corbel, E; Hay-Lombardie, A; Pallet, N1
Cho, H; Iijima, S; Kobayashi, S; Nishida, K; Sakai, N; Shiba, K; Toyoshima, Y1
Fujita, T; Ohashi, M; Toda, T1
Lott, JA; Pritchard, KA; Stephan, VA1
Dilena, BA; Fraser, CG; Penberthy, LA2
Gerbaut, L; Macart, M1
Dehon, B; Fialdes, P; Lefebvre, I; Mizon, C; Mizon, J; Perini, JM; Roussel, P1
Charbonneau, F; Heick, HM; Mohammed, A1
Heick, HM; Mohammed, A1
Jegge, S; Rieder, HP; Schnell, R1
Kanamori, K; Nakagawa, H; Nakajima, K; Nakao, M; Sano, K1
Ash, KO; Brown, PI; Shahangian, S2
Massenet, D; Molas, J; Pressac, D1
Cassells-Smith, AJ; McElderry, LA; Tarbit, IF1
Nakamura, J; Yakata, M1
Joern, WA; Schmoele, L1
Michaelis, HC; Thomas, L; Walb, D; Winckelmann, M1
Kanamori, K; Nakao, M; Sano, K; Shiba, A1
Acharya, C; Bégin-Heick, N; Heick, HM; Mohammed, A1
Diokno, AC; Mitchell, BA; Robinson, JE; Steinert, BW1
Marshall, T; Williams, KM4
Marshall, T; Williams, K1
Gossett, KA; Lynch, KM; Sellers, TS1
Cooke, S; Keevil, BG; Lockhart, S; Russell, J; Stec, Z; Wieringa, GE; Wong, WK1
Abbott, NJ; Marshall, T; Williams, J; Williams, KM1
Chisnall, WN; Crooke, MJ; Debnam, PM; Lim, CW; Stokes, YM1
Ho, P; Lau, P; Pun, KK; Wong, FH1
Jensen, R; Kirschstein, M; Sack, K; Schröder, R1
Frey, J; Le, J; Perier, C; Raby, N1
Kanamori, K; Shiba, K; Sugiura, K1
Klimek, M; Krzemień, D1
Casero, P; Del Campo, GB; Righetti, PG1
Rakov, SS1
Lott, JA; Wimsatt, DK1
Chisnall, WN; Crooke, MJ; Lim, CW; Pratt, R; Stokes, YM1
Goren, MP; Li, JT1
Ambroes, YI; Lievens, MM1
Harada, T; Kanamori, K; Kodaira, T; Nakagawa, H; Nakajima, K; Nakao, M; Shiba, KS1

Other Studies

44 other study(ies) available for c.i. 42510 and Proteinuria

ArticleYear
Urine protein quantification in stacking gel by SDS-PAGE.
    Electrophoresis, 2019, Volume: 40, Issue:4

    Topics: Electrophoresis, Polyacrylamide Gel; Humans; Proteins; Proteinuria; Rosaniline Dyes

2019
Quantitative measurement of urinary proteins in 2018: advantages, disadvantages, limits.
    Annales de biologie clinique, 2018, Dec-01, Volume: 76, Issue:6

    Topics: Biological Variation, Individual; Biuret; Costs and Cost Analysis; Evaluation Studies as Topic; Humans; Nephelometry and Turbidimetry; Proteinuria; Pyrogallol; Reference Values; Rosaniline Dyes; Urinalysis; Urine Specimen Collection

2018
Development of a new method for measuring total urinary protein using acid violet 6B pigment.
    Journal of clinical laboratory analysis, 2003, Volume: 17, Issue:5

    Topics: Adult; Aged; Aged, 80 and over; Bence Jones Protein; Benzenesulfonates; beta 2-Microglobulin; Calibration; Diabetic Nephropathies; Female; gamma-Globulins; Humans; Immunoglobulin A; Immunoglobulin G; Linear Models; Male; Methods; Middle Aged; Molybdenum; Mucoproteins; Orosomucoid; Proteins; Proteinuria; Pyrogallol; Random Allocation; Reproducibility of Results; Rosaniline Dyes; Sensitivity and Specificity; Serum Albumin; Transferrin; Uromodulin

2003
Silver stain for proteins on a cellulose acetate membrane.
    Analytical biochemistry, 1984, Volume: 139, Issue:2

    Topics: Animals; Densitometry; Electrophoresis, Cellulose Acetate; Humans; Leukemia; Muscle Proteins; Proteins; Proteinuria; Rats; Rosaniline Dyes; Silver; Staining and Labeling

1984
Evaluation of the Coomassie Brilliant Blue G-250 method for urinary protein.
    Clinical chemistry, 1983, Volume: 29, Issue:11

    Topics: Adult; Autoanalysis; Biuret; Evaluation Studies as Topic; Female; Humans; Infant, Newborn; Infant, Premature; Kidney Transplantation; Male; Middle Aged; Multiple Myeloma; Physical Exertion; Proteins; Proteinuria; Rosaniline Dyes; Spectrophotometry

1983
Can the coomassie Brilliant Blue method for urinary protein be defended?
    Clinical chemistry, 1984, Volume: 30, Issue:9

    Topics: Autoanalysis; Humans; Proteinuria; Rosaniline Dyes

1984
Evaluation of an improved Coomassie dye binding method for urinary protein assay.
    Clinica chimica acta; international journal of clinical chemistry, 1984, Aug-15, Volume: 141, Issue:1

    Topics: Biuret Reaction; Humans; Indicators and Reagents; Methods; Proteinuria; Rosaniline Dyes; Sodium Dodecyl Sulfate; Ultrafiltration

1984
Urinary protein determination using Coomassie Brilliant Blue in the presence of sodium dodecyl sulphate.
    Clinica chimica acta; international journal of clinical chemistry, 1984, Nov-30, Volume: 143, Issue:3

    Topics: Chemical Phenomena; Chemistry; Chromatography, Gel; Humans; Indicators and Reagents; Proteinuria; Rosaniline Dyes; Sodium Dodecyl Sulfate

1984
A defense of the Coomassie blue method for urinary protein.
    Clinical chemistry, 1983, Volume: 29, Issue:10

    Topics: Evaluation Studies as Topic; Humans; Proteins; Proteinuria; Rosaniline Dyes

1983
Problems with the Coomassie Brilliant Blue technique for urinary protein.
    Clinical chemistry, 1984, Volume: 30, Issue:6

    Topics: Diagnostic Errors; Humans; Proteinuria; Rosaniline Dyes

1984
Six methods for determining urinary protein compared.
    Clinical chemistry, 1983, Volume: 29, Issue:3

    Topics: Australia; Biuret Reaction; Chemistry, Clinical; Humans; Nephelometry and Turbidimetry; Proteinuria; Rosaniline Dyes

1983
[Determination of protein in cerebrospinal fluid: comparison of the Coomassie-Blue method and the Cu-Folin differential test].
    Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie, 1983, Volume: 21, Issue:3

    Topics: Cerebrospinal Fluid Proteins; Copper; Humans; Molybdenum; Proteinuria; Rosaniline Dyes; Tungsten; Tungsten Compounds

1983
[Study on the determination of urinary proteins--discrepancy between sulfosalicylic acid method and coomassie brilliant blue G-250 method].
    Rinsho byori. The Japanese journal of clinical pathology, 1983, Volume: 31, Issue:2

    Topics: Benzenesulfonates; Humans; Methods; Molecular Weight; Proteinuria; Rosaniline Dyes; Salicylates

1983
A Coomassie blue dye-binding method for determining urinary protein is dilution-dependent.
    Clinical chemistry, 1983, Volume: 29, Issue:7

    Topics: Humans; Methods; Proteinuria; Rosaniline Dyes

1983
[Assay of proteins in urine and cerebrospinal fluid by centrifugal analysis. Comparison of 3 methods].
    Annales de biologie clinique, 1983, Volume: 41, Issue:2

    Topics: Autoanalysis; Benzenesulfonates; Centrifugation; Cerebrospinal Fluid Proteins; Humans; Proteinuria; Rosaniline Dyes; Salicylates; Trichloroacetic Acid

1983
Six methods for urinary protein compared.
    Clinical chemistry, 1982, Volume: 28, Issue:2

    Topics: Azo Compounds; Biuret Reaction; Chlorides; Ferric Compounds; Humans; Hydrolyzable Tannins; Methods; Nephelometry and Turbidimetry; Proteinuria; Rosaniline Dyes; Trichloroacetic Acid

1982
Urine contains an inhibitor for turbidimetric determinations of protein.
    Clinical chemistry, 1982, Volume: 28, Issue:11

    Topics: Albuminuria; Benzenesulfonates; Chromatography, Gel; Humans; Nephelometry and Turbidimetry; Proteinuria; Rosaniline Dyes; Salicylates; Urine

1982
Urinary protein measurement by the Coomassie Blue dye-binding method adapted to the ABA-100 Bichromatic Analyzer.
    Clinical chemistry, 1981, Volume: 27, Issue:7

    Topics: Autoanalysis; Humans; Proteinuria; Rosaniline Dyes

1981
[Quantitative determination of total urinary protein utilizing the principle of Coomassie Brilliant Blue G250 binding to protein (author's transl)].
    Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie, 1981, Volume: 19, Issue:4

    Topics: Bence Jones Protein; Biuret; Diabetes Mellitus; False Negative Reactions; Humans; Kidney Failure, Chronic; Methods; Proteinuria; Rosaniline Dyes; Statistics as Topic

1981
Automatic assay of urinary protein using Coomassie Brilliant Blue G-250.
    Analytical biochemistry, 1981, May-01, Volume: 113, Issue:1

    Topics: Autoanalysis; Humans; Proteinuria; Rosaniline Dyes

1981
Automated determination of urine and cerebrospinal fluid proteins with Coomassie Brilliant Blue and the Abbott ABA-100.
    Clinical biochemistry, 1980, Volume: 13, Issue:2

    Topics: Autoanalysis; Cerebrospinal Fluid Proteins; Coloring Agents; Humans; Proteinuria; Rosaniline Dyes

1980
Semiautomated quantitation of urinary protein and creatinine.
    Computers and biomedical research, an international journal, 1995, Volume: 28, Issue:3

    Topics: Albuminuria; Computer Graphics; Creatinine; Database Management Systems; Humans; Indicators and Reagents; Microcomputers; Proteinuria; Rosaniline Dyes; Sensitivity and Specificity; Spectrophotometry, Ultraviolet; Time Factors; User-Computer Interface

1995
Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of urine: concentration of urinary proteins by precipitation with coomassie blue.
    Clinical chemistry, 1993, Volume: 39, Issue:11 Pt 1

    Topics: Chemical Precipitation; Coloring Agents; Electrophoresis, Polyacrylamide Gel; Humans; Proteinuria; Rosaniline Dyes; Silver Staining

1993
Two-dimensional electrophoresis of human urinary proteins following concentration by dye precipitation.
    Electrophoresis, 1996, Volume: 17, Issue:7

    Topics: Animals; Cattle; Chemical Precipitation; Coloring Agents; Electrophoresis, Gel, Two-Dimensional; Electrophoresis, Polyacrylamide Gel; Humans; Indicators and Reagents; Isoelectric Focusing; Proteinuria; Rosaniline Dyes; Silver Staining

1996
Evaluation of an automated pyrogallol red-molybdate method for the measurement of urinary protein in rats.
    European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies, 1996, Volume: 34, Issue:7

    Topics: Animals; Coloring Agents; Female; Male; Molybdenum; Proteinuria; Pyrogallol; Rats; Rats, Sprague-Dawley; Reagent Kits, Diagnostic; Reproducibility of Results; Rosaniline Dyes

1996
A comparison of three procedures for the detection of Bence-Jones proteinuria.
    Annals of clinical biochemistry, 1997, Volume: 34 ( Pt 4)

    Topics: Amido Black; Amyloidosis; Bence Jones Protein; Coloring Agents; Electrophoresis, Agar Gel; Gold; Humans; Immunologic Techniques; Indicators and Reagents; Multiple Myeloma; Proteinuria; Reagent Kits, Diagnostic; Rosaniline Dyes; Sensitivity and Specificity

1997
Screening for Bence Jones proteinuria using the coomassie Brilliant Blue and pyrogallol red protein assay values.
    Biochemical Society transactions, 1997, Volume: 25, Issue:4

    Topics: Bence Jones Protein; Coloring Agents; Diagnosis, Differential; Electrophoresis, Polyacrylamide Gel; Humans; Indicators and Reagents; Kidney Diseases; Paraproteinemias; Proteinuria; Pyrogallol; Regression Analysis; Rosaniline Dyes

1997
Determining total protein content of urine: centrifugation results in precipitation of the protein-coomassie brilliant blue dye complex.
    Clinical chemistry, 1992, Volume: 38, Issue:6

    Topics: Centrifugation; Chemical Precipitation; Humans; Indicators and Reagents; Proteinuria; Rosaniline Dyes

1992
Effects of low and high relative molecular protein mass on four methods for total protein determination in urine.
    Pathology, 1990, Volume: 22, Issue:2

    Topics: Azo Compounds; Biuret Reaction; Chemical Precipitation; Coloring Agents; Electrophoresis, Polyacrylamide Gel; Humans; Molecular Weight; Proteinuria; Reproducibility of Results; Rosaniline Dyes; Silver; Staining and Labeling

1990
Eight-month longitudinal study of urinary excretion of albumin and tubular proteins in diabetic subjects.
    American journal of nephrology, 1990, Volume: 10, Issue:6

    Topics: Adult; Albuminuria; Diabetic Nephropathies; Electrophoresis, Polyacrylamide Gel; Female; Humans; Longitudinal Studies; Male; Proteinuria; Radioimmunoassay; Rosaniline Dyes; Staining and Labeling; Time Factors

1990
Proteinuria after renal transplantation: diagnosis with highly sensitive silver stain in sodium dodecylsulphate-polyacrylamide gradient gel electrophoresis.
    Klinische Wochenschrift, 1991, Nov-15, Volume: 69, Issue:18

    Topics: Adult; Aged; Cyclosporine; Diagnosis, Differential; Dose-Response Relationship, Drug; Electrophoresis, Polyacrylamide Gel; Female; Graft Rejection; Humans; Kidney Transplantation; Male; Middle Aged; Postoperative Complications; Proteinuria; Rosaniline Dyes; Silver Staining

1991
[Discussion about pretreatment of samples before protein assay with Coomassie brilliant blue].
    Annales de biologie clinique, 1991, Volume: 49, Issue:4

    Topics: Cerebrospinal Fluid Proteins; Premedication; Proteinuria; Rosaniline Dyes; Sampling Studies

1991
[Development and clinical evaluation of a new urinary protein test paper (URINE-TP)].
    Rinsho byori. The Japanese journal of clinical pathology, 1991, Volume: 39, Issue:4

    Topics: Bence Jones Protein; Globulins; Humans; Proteinuria; Reagent Strips; Rosaniline Dyes

1991
[Usefulness of the Coomassie brilliant blue method for quantitation of total protein in the urine].
    Przeglad lekarski, 1990, Volume: 47, Issue:2

    Topics: Erythrocyte Count; Humans; Proteinuria; Rosaniline Dyes

1990
Gold staining in cellulose acetate membranes.
    Clinica chimica acta; international journal of clinical chemistry, 1986, Jun-15, Volume: 157, Issue:2

    Topics: Blood Proteins; Cerebrospinal Fluid Proteins; Electrophoresis, Cellulose Acetate; Gold; Humans; Proteins; Proteinuria; Rosaniline Dyes; Serum Albumin; Silver; Staining and Labeling

1986
[Determination of the concentration of protein in urine].
    Laboratornoe delo, 1987, Issue:2

    Topics: Colorimetry; Female; Humans; Male; Proteinuria; Rosaniline Dyes

1987
Improved measurement of urinary total protein (including light-chain proteins) with a Coomassie brilliant blue G-250-sodium dodecyl sulfate reagent.
    Clinical chemistry, 1987, Volume: 33, Issue:11

    Topics: Adult; Aged; Aged, 80 and over; Coloring Agents; Female; Humans; Immunoglobulin kappa-Chains; Immunoglobulin lambda-Chains; Male; Middle Aged; Multiple Myeloma; Proteinuria; Rosaniline Dyes; Sodium Dodecyl Sulfate; Spectrophotometry

1987
Effects of sodium dodecylsulphate, dye concentration and paraprotein on coomassie blue dye-binding assays for protein in urine.
    Clinical biochemistry, 1988, Volume: 21, Issue:5

    Topics: Binding, Competitive; Coloring Agents; Humans; Proteinuria; Rosaniline Dyes; Sodium Dodecyl Sulfate

1988
More on the dilution dependence of the Coomassie Brilliant Blue technique for urinary protein.
    Clinical chemistry, 1986, Volume: 32, Issue:2

    Topics: Dye Dilution Technique; False Negative Reactions; Humans; Proteins; Proteinuria; Rosaniline Dyes

1986
Simplified sodium dodecyl sulfate-polyacrylamide gel electrophoresis of unconcentrated urine with enhanced resolution and detection sensitivity.
    Clinical chemistry, 1987, Volume: 33, Issue:10

    Topics: Electrophoresis, Polyacrylamide Gel; Humans; Proteinuria; Rosaniline Dyes; Sodium Dodecyl Sulfate; Urine

1987
Comparison of Coomassie Brilliant Blue protein dye-binding assays for determination of urinary protein concentration.
    Clinical chemistry, 1987, Volume: 33, Issue:4

    Topics: Humans; Methods; Proteinuria; Rosaniline Dyes

1987
The Coomassie Brilliant Blue method underestimates drug-induced tubular proteinuria.
    Clinical chemistry, 1986, Volume: 32, Issue:2

    Topics: Biuret Reaction; False Negative Reactions; Humans; Indicators and Reagents; Kidney Tubules; Proteins; Proteinuria; Rosaniline Dyes; Serum Albumin

1986
Threshold of pathological proteinuria measured with Coomassie Brilliant Blue.
    Clinical chemistry, 1985, Volume: 31, Issue:1

    Topics: Chemical Precipitation; Humans; Mucoproteins; Proteinuria; Rosaniline Dyes; Spectrophotometry

1985
A cause of discrepancy between values for urinary protein as assayed by the Coomassie Brilliant Blue G-250 method and the sulfosalicylic acid method.
    Clinical chemistry, 1985, Volume: 31, Issue:7

    Topics: Benzenesulfonates; Electrophoresis, Polyacrylamide Gel; False Positive Reactions; Humans; Molecular Weight; Mucoproteins; Orosomucoid; Proteinuria; Rosaniline Dyes; Salicylates; Uromodulin

1985