blz-100 and Brain-Neoplasms

blz-100 has been researched along with Brain-Neoplasms* in 2 studies

Trials

1 trial(s) available for blz-100 and Brain-Neoplasms

ArticleYear
Phase 1 Safety, Pharmacokinetics, and Fluorescence Imaging Study of Tozuleristide (BLZ-100) in Adults With Newly Diagnosed or Recurrent Gliomas.
    Neurosurgery, 2019, 10-01, Volume: 85, Issue:4

    Fluorescence-guided surgery (FGS) can improve extent of resection in gliomas. Tozuleristide (BLZ-100), a near-infrared imaging agent composed of the peptide chlorotoxin and a near-infrared fluorophore indocyanine green, is a candidate molecule for FGS of glioma and other tumor types.. To perform a phase 1 dose-escalation study to characterize the safety, pharmacokinetics, and fluorescence imaging of tozuleristide in adults with suspected glioma.. Patients received a single intravenous dose of tozuleristide 3 to 29 h before surgery. Fluorescence images of tumor and cavity in Situ before and after resection and of excised tissue ex Vivo were acquired, along with safety and pharmacokinetic measures.. A total of 17 subjects received doses between 3 and 30 mg. No dose-limiting toxicity was observed, and no reported adverse events were considered related to tozuleristide. At doses of 9 mg and above, the terminal serum half-life for tozuleristide was approximately 30 min. Fluorescence signal was detected in both high- and low-grade glial tumors, with high-grade tumors generally showing greater fluorescence intensity compared to lower grade tumors. In high-grade tumors, signal intensity increased with increased dose levels of tozuleristide, regardless of the time of dosing relative to surgery.. These results support the safety of tozuleristide at doses up to 30 mg and suggest that tozuleristide imaging may be useful for FGS of gliomas.

    Topics: Adult; Aged; Brain Neoplasms; Dose-Response Relationship, Drug; Female; Fluorescent Dyes; Glioma; Humans; Indocyanine Green; Injections, Intravenous; Male; Middle Aged; Neoplasm Recurrence, Local; Optical Imaging; Scorpion Venoms

2019

Other Studies

1 other study(ies) available for blz-100 and Brain-Neoplasms

ArticleYear
Near-infrared imaging of brain tumors using the Tumor Paint BLZ-100 to achieve near-complete resection of brain tumors.
    Neurosurgical focus, 2014, Volume: 36, Issue:2

    The intraoperative clear delineation between brain tumor and normal tissue in real time is required to ensure near-complete resection without damaging the nearby eloquent brain. Tumor Paint BLZ-100, a tumor ligand chlorotoxin (CTX) conjugated to indocyanine green (ICG), has shown potential to be a targeted contrast agent. There are many infrared imaging systems in use, but they are not optimized to the low concentration and amount of ICG. The authors present a novel proof-of-concept near-infrared (NIR) imaging system using a standard charge-coupled device (CCD) camera for visualizing low levels of ICG attached to the tumors. This system is small, inexpensive, and sensitive. The imaging system uses a narrow-band laser at 785 nm and a notch filter in front of the sensor at the band. The camera is a 2-CCD camera, which uses identical CCDs for both visible and NIR light.. The NIR system is tested with serial dilution of BLZ-100 from 1 μM to 50 pM in 5% Intralipid solution while the excitation energy is varied from 5 to 40 mW/cm(2). The analog gain of the CCD was changed from 0, 6, and 12 dB to determine the signal-to-noise ratio. In addition to the Intralipid solution, BLZ-100 was injected 48 hours before euthanizing the mice that were implanted with the human glioma cell line. The brain was removed and imaged using the NIR imaging system.. The authors' results show that the NIR imaging system using a standard CCD is able to visualize the ICG down to 50 nM of concentration with a high signal-to-noise ratio. The preliminary experiment on human glioma implanted in mouse brains demonstrated that BLZ-100 has a high affinity for glioma compared with normal brain tissue. Additionally, the results show that NIR excitation is able to penetrate deeply and has a potential to visualize metastatic lesions that are separate from the main tumor.. The authors have seen that BLZ-100 has a very high affinity toward human gliomas. They also describe a small, cost-effective, and sensitive NIR system for visualizing brain tumors tagged using BLZ-100. The authors hope that the use of BLZ-100 along with NIR imaging will be useful to delineate the brain tumors in real time and assist surgeons in near-complete tumor removal to increase survival and reduce neurological deficits.

    Topics: Animals; Brain Neoplasms; Diagnostic Imaging; Humans; Indocyanine Green; Mice; Scorpion Venoms; Spectroscopy, Near-Infrared

2014