Page last updated: 2024-08-26

aluminum and Prosthesis Durability

aluminum has been researched along with Prosthesis Durability in 38 studies

Research

Studies (38)

TimeframeStudies, this research(%)All Research%
pre-19905 (13.16)18.7374
1990's18 (47.37)18.2507
2000's11 (28.95)29.6817
2010's4 (10.53)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Apostoli, P; Beraudi, A; Bordini, B; Catalani, S; Gilberti, ME; Stea, S; Toni, A1
Boffelli, M; Chotanaphuti, T; Khuangsirikul, S; Pezzotti, G; Sugano, N; Zhu, W1
Clarke, IC; Manley, MT1
Arya, AP; Klenerman, L1
Kim, HJ; Koo, KH; Nam, KW; Yoo, JJ; Yoon, KS1
Agathangelidis, FG; Christodoulou, AG; Hatzokos, IG; Papadopoulos, PP; Papavasiliou, KA; Petsatodis, GE1
Ma, L; Rainforth, WM; Stewart, T; Valdez, AN; Zeng, P1
Fisher, J; Hatton, A; Ingham, E; Matthews, JB; Nevelos, JE1
Hirasawa, Y; Kusaka, Y; Takai, S; Watanabe, Y; Yoshino, N1
Delaunay, C1
Iwaki, H; Kadoya, Y; Kobayashi, A; Minoda, Y; Miyaguchi, M; Ohashi, H; Takaoka, K1
Kold, S; Overgaard, S; Rahbek, O; Søballe, K; Zippor, B1
Adam, P; Bousquet, G; Farizon, F; Fessy, MH; Philippot, R1
Kovac, S; Milosev, I; Pavlovcic, V; Pisot, V; Trebse, R1
Corrin, B; Dewar, A; Heatley, FW; Shahgaldi, BF1
Tuntiprawon, M; Wilson, PR1
Frech, W; Kärrholm, J; Nilsson, KG; Snorrason, F1
Kerboull, L; Nizard, RS; Sedel, L; Witvoet, J1
Lyberg, T; Trumpy, IG1
Brown, SA; Davy, DT; Heiner, AD1
Engh, CA; Engh, GA; Moore, KD; Vinh, TN1
Allain, J; Goutallier, D; Le Mouel, S1
Autschbach, R; Diegeler, A; Falk, V; Günther, B; Mohr, FW; Rauch, T; van Son, JA; Walther, T; Weigl, C1
Petersen, MB; Poulsen, IH; Solgaard, S; Thomsen, J1
McCormack, BA; Prendergast, PJ1
Dohi, T; Kikuta, Y; Mitamura, Y; Ohta, Y; Shimooka, T; Yuhta, T1
Black, J; Galante, JO; Jacobs, JJ; Skipor, AK; Urban, Rm1
Flowers, WB; Levy, RJ; Schoen, FJ; Staelin, ST1
Boyd, J; Levy, RJ; Pathak, YV; Schoen, FJ1
Black, J; Bonini, J; Galante, JO; Rostoker, WR; Schajowicz, F; Sherk, H1
Frankel, VH; Kummer, FJ; Stuchin, SA1
Anneroth, G; Ericsson, AR; Zetterqvist, L1
Ben Abdallah, A; Mandrino, A; Moyen, B; Orange, D; Treheux, D1
Christel, P; Dorlot, JM; Meunier, A1
Benenati, FW1
Agins, HJ; Alcock, NW; Bansal, M; Bullough, PG; Pellicci, PM; Salvati, EA; Wilson, PD1
Strutz, J; Zöllner, C1
Christel, P; Herman, S; Sedel, L; Witvoët, J1

Reviews

1 review(s) available for aluminum and Prosthesis Durability

ArticleYear
[Can metal-on-metal bearings improve the longevity of total hip prostheses?].
    Revue de chirurgie orthopedique et reparatrice de l'appareil moteur, 2005, Volume: 91, Issue:1

    Topics: Aluminum; Arthroplasty, Replacement, Hip; Hip Prosthesis; Humans; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Time Factors

2005

Trials

1 trial(s) available for aluminum and Prosthesis Durability

ArticleYear
Increased metal release from cemented femoral components made of titanium alloy. 19 hip prostheses followed with radiostereometry (RSA).
    Acta orthopaedica Scandinavica, 1994, Volume: 65, Issue:6

    Topics: Adult; Aged; Aluminum; Bone Cements; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Osseointegration; Prosthesis Failure; Range of Motion, Articular; Stereotaxic Techniques; Synovial Fluid; Titanium; Vanadium

1994

Other Studies

36 other study(ies) available for aluminum and Prosthesis Durability

ArticleYear
Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis.
    Clinical toxicology (Philadelphia, Pa.), 2013, Volume: 51, Issue:7

    Topics: Adult; Aged; Aged, 80 and over; Alloys; Aluminum; Arthroplasty, Replacement, Hip; Biomarkers; Female; Hip Prosthesis; Humans; Male; Mass Spectrometry; Middle Aged; Pain, Postoperative; Prosthesis Failure; Titanium; Up-Regulation; Vanadates

2013
Chemistry-driven structural alterations in short-term retrieved ceramic-on-metal hip implants: Evidence for in vivo incompatibility between ceramic and metal counterparts.
    Journal of biomedical materials research. Part B, Applied biomaterials, 2017, Volume: 105, Issue:6

    Topics: Aluminum; Ceramics; Equipment Failure Analysis; Female; Hip Prosthesis; Humans; Middle Aged; Prosthesis Failure; Zirconium

2017
How do alternative bearing surfaces influence wear behavior?
    The Journal of the American Academy of Orthopaedic Surgeons, 2008, Volume: 16 Suppl 1

    Topics: Aluminum; Biocompatible Materials; Ceramics; Equipment Failure Analysis; Friction; Hip Prosthesis; Humans; Materials Testing; Metals; Polyethylene; Prosthesis Design; Prosthesis Failure; Stress, Mechanical; Surface Properties

2008
The Jaipur foot.
    The Journal of bone and joint surgery. British volume, 2008, Volume: 90, Issue:11

    Topics: Africa; Aluminum; Amputees; Artificial Limbs; Asia, Southeastern; Developing Countries; Foot; Humans; India; Materials Testing; Polypropylenes; Prosthesis Design; Prosthesis Failure; Prosthesis Fitting; Rubber; Tibia; Wood

2008
Optimal sterilization method for the zirconia/alumina composites used for total hip replacements.
    Journal of biomedical materials research. Part B, Applied biomaterials, 2009, Volume: 90, Issue:2

    Topics: Aluminum; Arthroplasty, Replacement, Hip; Biocompatible Materials; Dose-Response Relationship, Radiation; Ethylene Oxide; Femur Head; Hip Joint; Humans; Materials Testing; Microbial Sensitivity Tests; Prosthesis Failure; Sterilization; Stress, Mechanical; Surface Properties; Zirconium

2009
Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up.
    The Journal of bone and joint surgery. American volume, 2010, Volume: 92, Issue:3

    Topics: Adult; Aged; Aluminum; Arthroplasty, Replacement, Hip; Ceramics; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylene; Prosthesis Design; Prosthesis Failure; Reoperation; Retrospective Studies; Surface Properties; Treatment Outcome

2010
Dynamic surface microstructural changes during tribological contact that determine the wear behaviour of hip prostheses: metals and ceramics.
    Faraday discussions, 2012, Volume: 156

    Topics: Aluminum; Arthroplasty, Replacement, Hip; Biocompatible Materials; Female; Hip Prosthesis; Humans; Materials Testing; Microscopy, Electron, Scanning; Microscopy, Electron, Transmission; Prosthesis Design; Prosthesis Failure; Surface Properties; Vitallium; Zirconium

2012
Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes.
    Biomaterials, 2003, Volume: 24, Issue:7

    Topics: Aluminum; Biocompatible Materials; Cell Culture Techniques; Cell Survival; Ceramics; Hip Prosthesis; Humans; Leukocytes, Mononuclear; Prosthesis Failure; Stress, Mechanical; Tumor Necrosis Factor-alpha

2003
Dissemination of metals from a failed patellar component made of titanium-base alloy.
    The Journal of arthroplasty, 2003, Volume: 18, Issue:7

    Topics: Alloys; Aluminum; Arthroplasty, Replacement, Knee; Biocompatible Materials; Humans; Knee Prosthesis; Polyethylene; Prosthesis Failure; Reoperation; Skin; Titanium; Vanadium

2003
Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis.
    Biomaterials, 2005, Volume: 26, Issue:30

    Topics: Aged; Aluminum; Aluminum Oxide; Arthroplasty, Replacement, Knee; Biocompatible Materials; Ceramics; Female; Humans; Knee Prosthesis; Male; Materials Testing; Microscopy, Electron, Scanning; Middle Aged; Osteoarthritis; Polyethylene; Polyethylenes; Prosthesis Design; Prosthesis Failure; Synovial Fluid

2005
Particle migration and gap healing around trabecular metal implants.
    International orthopaedics, 2005, Volume: 29, Issue:6

    Topics: Aluminum; Animals; Coated Materials, Biocompatible; Dogs; Foreign-Body Migration; Knee Prosthesis; Particle Size; Polyethylene; Prosthesis Failure; Random Allocation; Statistics, Nonparametric; Surface Properties; Tantalum; Titanium; Wound Healing

2005
[Survival of cementless dual mobility sockets: ten-year follow-up].
    Revue de chirurgie orthopedique et reparatrice de l'appareil moteur, 2006, Volume: 92, Issue:4

    Topics: Adult; Age Factors; Aged; Aged, 80 and over; Aluminum; Arthroplasty, Replacement, Hip; Chromium Alloys; Data Interpretation, Statistical; Follow-Up Studies; Hip Prosthesis; Humans; Middle Aged; Polyethylenes; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Stainless Steel; Time Factors

2006
Long-term survival of a cemented titanium-aluminium-vanadium alloy straight-stem femoral component.
    The Journal of bone and joint surgery. British volume, 2006, Volume: 88, Issue:12

    Topics: Aged; Aged, 80 and over; Alloys; Aluminum; Cementation; Epidemiologic Methods; Female; Hip Prosthesis; Humans; Male; Middle Aged; Prosthesis Design; Prosthesis Failure; Reoperation; Titanium; Treatment Outcome

2006
In vivo corrosion of cobalt-chromium and titanium wear particles.
    The Journal of bone and joint surgery. British volume, 1995, Volume: 77, Issue:6

    Topics: Aluminum; Bone Resorption; Chromium; Chromium Alloys; Cobalt; Corrosion; Foreign Bodies; Hip Joint; Hip Prosthesis; Humans; Knee Joint; Knee Prosthesis; Microscopy, Electron; Microscopy, Electron, Scanning; Particle Size; Prosthesis Failure; Reoperation; Spectrometry, X-Ray Emission; Titanium

1995
The effect of cement thickness on the fracture strength of all-ceramic crowns.
    Australian dental journal, 1995, Volume: 40, Issue:1

    Topics: Aluminum; Cementation; Ceramics; Crowns; Dental Impression Technique; Dental Porcelain; Dental Prosthesis Design; Materials Testing; Platinum; Prosthesis Failure; Stress, Mechanical; Surface Properties; Zinc Phosphate Cement

1995
Alumina-alumina hip replacement in patients younger than 50 years old.
    Clinical orthopaedics and related research, 1994, Issue:298

    Topics: Adult; Age Factors; Aluminum; Female; Follow-Up Studies; Gait; Hip Prosthesis; Humans; Male; Middle Aged; Pain, Postoperative; Prosthesis Design; Prosthesis Failure; Range of Motion, Articular; Reoperation; Survival Analysis; Treatment Failure

1994
In vivo deterioration of proplast-teflon temporomandibular joint interpositional implants: a scanning electron microscopic and energy-dispersive X-ray analysis.
    Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons, 1993, Volume: 51, Issue:6

    Topics: Adult; Aluminum; Aluminum Oxide; Bone Resorption; Electron Probe Microanalysis; Follow-Up Studies; Granuloma, Foreign-Body; Humans; Joint Dislocations; Joint Prosthesis; Mandibular Condyle; Microscopy, Electron, Scanning; Middle Aged; Polytetrafluoroethylene; Proplast; Prosthesis Failure; Temporal Bone; Temporomandibular Joint; Temporomandibular Joint Disorders

1993
Effects of mechanical testing device variables on polymer composite femoral stem strains.
    Biomaterials, 1996, Volume: 17, Issue:23

    Topics: Aluminum; Biocompatible Materials; Bone Cements; Bone Resorption; Chromium Alloys; Elasticity; Friction; Hip Prosthesis; Humans; Materials Testing; Models, Anatomic; Polymers; Prosthesis Failure; Resins, Synthetic; Stress, Mechanical; Tensile Strength; Titanium; Wood

1996
Titanium prosthetic wear debris in remote bone marrow. A report of two cases.
    The Journal of bone and joint surgery. American volume, 1997, Volume: 79, Issue:11

    Topics: Acetabulum; Aged; Aluminum; Arthroplasty, Replacement, Hip; Arthroplasty, Replacement, Knee; Bone Marrow; Electron Probe Microanalysis; Female; Femoral Fractures; Fractures, Spontaneous; Hip Prosthesis; Humans; Knee Prosthesis; Male; Middle Aged; Osteolysis; Patella; Prosthesis Failure; Reoperation; Titanium; Vanadium

1997
[10-year actuarial analysis of a cohort of 156 total hip prostheses of a cemented polished aluminum/polyethylene alloy].
    Revue de chirurgie orthopedique et reparatrice de l'appareil moteur, 1998, Volume: 84, Issue:4

    Topics: Actuarial Analysis; Adult; Aged; Alloys; Aluminum; Arthroplasty, Replacement, Hip; Female; Follow-Up Studies; Hip Prosthesis; Humans; Male; Middle Aged; Polyethylenes; Prosthesis Design; Prosthesis Failure

1998
Comparison of different anticalcification treatments for stentless bioprostheses.
    The Annals of thoracic surgery, 1998, Volume: 66, Issue:6 Suppl

    Topics: Aluminum; Animals; Aortic Valve; Bioprosthesis; Calcinosis; Calcium; Disease Models, Animal; Durapatite; Ethanol; Fixatives; Glutaral; Heart Valve Prosthesis; Male; Oleic Acids; Prosthesis Design; Prosthesis Failure; Rats; Rats, Sprague-Dawley; Spectrophotometry; Surface-Active Agents

1998
The hemispherical Harris-Galante acetabular cup, inserted without cement. The results of an eight to eleven-year follow-up of one hundred and sixty-eight hips.
    The Journal of bone and joint surgery. American volume, 1999, Volume: 81, Issue:2

    Topics: Acetabulum; Aluminum; Arthritis, Rheumatoid; Arthroplasty, Replacement, Hip; Bone Cements; Ceramics; Femoral Neck Fractures; Femur Head Necrosis; Hip Joint; Hip Prosthesis; Humans; Osteoarthritis, Hip; Prosthesis Design; Prosthesis Failure; Radiography; Survival Analysis; Treatment Outcome

1999
Microdamage accumulation in the cement layer of hip replacements under flexural loading.
    Journal of biomechanics, 1999, Volume: 32, Issue:5

    Topics: Aluminum; Bone Cements; Cementation; Coloring Agents; Elasticity; Femur; Finite Element Analysis; Hip Prosthesis; Humans; Materials Testing; Prosthesis Design; Prosthesis Failure; Steel; Stress, Mechanical; Surface Properties

1999
Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.
    Artificial organs, 2000, Volume: 24, Issue:4

    Topics: Alloys; Aluminum; Aortic Valve; Blood Pressure; Heart Rate; Heart Valve Prosthesis; Hemorheology; Humans; Image Processing, Computer-Assisted; Models, Anatomic; Movement; Prosthesis Design; Prosthesis Failure; Regional Blood Flow; Silicone Elastomers; Sinus of Valsalva; Video Recording

2000
Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy.
    The Journal of bone and joint surgery. American volume, 1991, Volume: 73, Issue:10

    Topics: Adult; Aged; Alloys; Aluminum; Female; Hip Prosthesis; Humans; Male; Middle Aged; Prosthesis Failure; Specimen Handling; Spectrophotometry, Atomic; Titanium; Vanadium

1991
Initiation of mineralization in bioprosthetic heart valves: studies of alkaline phosphatase activity and its inhibition by AlCl3 or FeCl3 preincubations.
    Journal of biomedical materials research, 1991, Volume: 25, Issue:8

    Topics: Alkaline Phosphatase; Aluminum; Aluminum Chloride; Aluminum Compounds; Animals; Bioprosthesis; Calcinosis; Chlorides; Ferric Compounds; Heart Valve Prosthesis; Histocytochemistry; Mice; Mice, Inbred BALB C; Mice, Nude; Microscopy, Electron; Organelles; Prosthesis Failure; Rats; Swine; Time Factors

1991
Prevention of calcification of glutaraldehyde pretreated bovine pericardium through controlled release polymeric implants: studies of Fe3+, Al3+, protamine sulphate and levamisole.
    Biomaterials, 1990, Volume: 11, Issue:9

    Topics: Aluminum; Animals; Calcium Phosphates; Cattle; Delayed-Action Preparations; Drug Implants; Ferric Compounds; Glutaral; Heart; Heart Valve Prosthesis; Levamisole; Male; Myocardium; Ossification, Heterotopic; Prosthesis Failure; Protamines; Rats; Silicone Elastomers

1990
Metallosis associated with a stable titanium-alloy femoral component in total hip replacement. A case report.
    The Journal of bone and joint surgery. American volume, 1990, Volume: 72, Issue:1

    Topics: Acetabulum; Aged; Aluminum; Female; Hip Joint; Hip Prosthesis; Humans; Microscopy, Electron, Scanning; Prosthesis Failure; Radiography; Reoperation; Stress, Mechanical; Synovial Membrane; Titanium

1990
Analysis of removed autophor ceramic-on-ceramic components.
    The Journal of arthroplasty, 1990, Volume: 5, Issue:1

    Topics: Adult; Aluminum; Aluminum Oxide; Biocompatible Materials; Ceramics; Female; Hip Prosthesis; Humans; Male; Middle Aged; Prosthesis Failure; Synovial Membrane; Time Factors

1990
Tissue integration of A12O3-ceramic dental implants (Frialit)--a case report.
    Swedish dental journal, 1990, Volume: 14, Issue:2

    Topics: Adult; Aluminum; Aluminum Oxide; Alveolar Process; Biocompatible Materials; Bone Regeneration; Dental Implantation, Endosseous; Dental Implants; Dental Porcelain; Humans; Male; Prosthesis Failure; Wound Healing

1990
Aluminas with dispersoids. Tribologic properties and in vivo aging.
    Biomaterials, 1990, Volume: 11

    Topics: Aluminum; Aluminum Oxide; Animals; Biocompatible Materials; Ceramics; Materials Testing; Molecular Weight; Polyethylenes; Prosthesis Failure; Rats; Rats, Inbred Strains; Stress, Mechanical; Time Factors

1990
Wear analysis of retrieved alumina heads and sockets of hip prostheses.
    Journal of biomedical materials research, 1989, Volume: 23, Issue:A3 Suppl

    Topics: Aged; Aged, 80 and over; Aluminum; Aluminum Oxide; Ceramics; Female; Hip Prosthesis; Humans; Male; Microscopy, Electron, Scanning; Middle Aged; Prosthesis Failure; Surface Properties

1989
Resection of a sapphire endodontic stabilizer due to perforation of the maxillary sinus: report of a case.
    Journal of endodontics, 1989, Volume: 15, Issue:12

    Topics: Aluminum; Aluminum Oxide; Dental Implantation, Endosseous, Endodontic; Female; Foreign Bodies; Humans; Maxillary Sinus; Middle Aged; Prosthesis Failure

1989
Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis.
    The Journal of bone and joint surgery. American volume, 1988, Volume: 70, Issue:3

    Topics: Adolescent; Aged; Aged, 80 and over; Alloys; Aluminum; Connective Tissue; Electron Probe Microanalysis; Female; Foreign-Body Reaction; Hip Joint; Hip Prosthesis; Humans; Male; Middle Aged; Prosthesis Failure; Spectrophotometry, Atomic; Synovial Membrane; Titanium; Vanadium

1988
[Middle ear implants (Tübingen type) of Al2O3 ceramics. Follow-up to 6 years after surgery].
    Laryngologie, Rhinologie, Otologie, 1987, Volume: 66, Issue:10

    Topics: Aluminum; Aluminum Oxide; Audiometry, Pure-Tone; Cartilage; Cholesteatoma; Ear Ossicles; Follow-Up Studies; Humans; Otitis Media; Postoperative Complications; Prostheses and Implants; Prosthesis Design; Prosthesis Failure; Stapes Surgery; Tympanoplasty

1987
[Loosening of the acetabulum cemented in aluminum. Etiology and solution].
    Revue de chirurgie orthopedique et reparatrice de l'appareil moteur, 1985, Volume: 71 Suppl 2

    Topics: Acetabulum; Adhesiveness; Aged; Aluminum; Bone Cements; Female; Hardness; Hip Prosthesis; Humans; Male; Middle Aged; Prosthesis Failure

1985