technetium tc 99m sestamibi has been researched along with perfluorobutane in 7 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 0 (0.00) | 18.7374 |
1990's | 5 (71.43) | 18.2507 |
2000's | 1 (14.29) | 29.6817 |
2010's | 1 (14.29) | 24.3611 |
2020's | 0 (0.00) | 2.80 |
Authors | Studies |
---|---|
Aristizabal, D; Cheirif, J; Collins, TJ; Meza, MF; Mobarek, S; Murgo, JP; Ramee, SR; Shuler, S; Sonnemaker, R; White, CJ | 1 |
Baer, FM; Binder, T; Brochet, E; Brunken, R; Flachskampf, F; Kamp, O; Lindvall, K; Marwick, TH; Meland, N; Nienaber, C; Nihoyannopoulos, P; Pierard, L; van der Wouw, P; Vanoverschelde, JL | 1 |
Cotter, B; DeMaria, AN; Ohmori, K | 1 |
Assayag, P; Baer, F; Binder, T; Flachskampf, F; Kamp, O; Lindvall, K; Marelli, C; Meland, N; Nienaber, C; Nihoyannopoulos, P; PiƩrard, L; Steg, G; Van der Wouw, P; Vanoverschelde, JL | 1 |
Brunken, R; Greenberg, N; Marwick, TH; Pasquet, A; Thomas, JD | 1 |
D'Hondt, AM; Glass, D; Jucquois, I; Melin, JA; Nihoyannopoulos, P; Robert, A; Roelants, V; Vanoverschelde, JL | 1 |
Gurunathan, S; Karogiannis, N; Pabla, J; Senior, R; Vamvakidou, A; Young, G | 1 |
4 trial(s) available for technetium tc 99m sestamibi and perfluorobutane
Article | Year |
---|---|
Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators.
Topics: Contrast Media; Coronary Circulation; Echocardiography; Feasibility Studies; Female; Ferric Compounds; Heart Ventricles; Humans; Infusions, Intravenous; Iron; Male; Middle Aged; Myocardial Contraction; Myocardial Infarction; Oxides; Radiopharmaceuticals; Reproducibility of Results; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon | 1998 |
NC100100, a new echo contrast agent for the assessment of myocardial perfusion--safety and comparison with technetium-99m sestamibi single-photon emission computed tomography in a randomized multicenter study.
Topics: Aged; Contrast Media; Dose-Response Relationship, Drug; Echocardiography; Female; Ferric Compounds; Humans; Iron; Male; Middle Aged; Myocardial Infarction; Myocardial Reperfusion; Oxides; Prospective Studies; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon | 1999 |
Effect of color coding and subtraction on the accuracy of contrast echocardiography.
Topics: Contrast Media; Coronary Circulation; Echocardiography; Feasibility Studies; Female; Ferric Compounds; Humans; Image Processing, Computer-Assisted; Injections, Intravenous; Iron; Male; Middle Aged; Myocardial Infarction; Oxides; Radiopharmaceuticals; Reproducibility of Results; Severity of Illness Index; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon | 1999 |
Comparison of myocardial contrast echocardiography with NC100100 and (99m)Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction.
Topics: Aged; Aged, 80 and over; Contrast Media; Coronary Circulation; Coronary Vessels; Female; Ferric Compounds; Humans; Iron; Male; Middle Aged; Myocardial Contraction; Myocardial Infarction; Observer Variation; Oxides; Radiopharmaceuticals; Sensitivity and Specificity; Single-Blind Method; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon; Ultrasonography | 2000 |
3 other study(ies) available for technetium tc 99m sestamibi and perfluorobutane
Article | Year |
---|---|
Myocardial contrast echocardiography in human beings: correlation of resting perfusion defects to sestamibi single photon emission computed tomography.
Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Coronary Angiography; Coronary Circulation; Coronary Disease; Coronary Vessels; Diastole; Echocardiography; Female; Ferric Compounds; Humans; Image Processing, Computer-Assisted; Iron; Linear Models; Male; Meglumine; Middle Aged; Myocardial Infarction; Observer Variation; Oxides; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon | 1996 |
Myocardial contrast echocardiography: too much, too soon?
Topics: Animals; Contrast Media; Coronary Circulation; Coronary Disease; Echocardiography; Ferric Compounds; Humans; Infusions, Intravenous; Iron; Myocardial Contraction; Oxides; Radiopharmaceuticals; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon | 1998 |
Long-Term Association of Dipyridamole Stress Myocardial Contrast Echocardiography versus Single-Photon Emission Computed Tomography with Clinical Outcomes in Patients with Known or Suspected Coronary Artery Disease.
Topics: Cause of Death; Contrast Media; Coronary Artery Disease; Dipyridamole; Echocardiography, Stress; Female; Ferric Compounds; Humans; Iron; Male; Middle Aged; Oxides; Radiopharmaceuticals; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon | 2018 |