Page last updated: 2024-08-16

technetium tc 99m sestamibi and ammonium hydroxide

technetium tc 99m sestamibi has been researched along with ammonium hydroxide in 8 studies

*Ammonium Hydroxide: The hydroxy salt of ammonium ion. It is formed when AMMONIA reacts with water molecules in solution. [MeSH]

*Ammonium Hydroxide: The hydroxy salt of ammonium ion. It is formed when AMMONIA reacts with water molecules in solution. [MeSH]

Research

Studies (8)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's1 (12.50)18.2507
2000's5 (62.50)29.6817
2010's1 (12.50)24.3611
2020's1 (12.50)2.80

Authors

AuthorsStudies
Ausma, JJ; Borgers, M; Flameng, W; Maes, AF; Mortelmans, LA; Nuyts, JL; Sergeant, P; van de Werf, F1
Bøttcher, M; Flø, C; Kaltoft, A; Nielsen, TT; Rehling, M; Sand, NP1
Hisada, K; Kanayama, S; Matsudaira, M; Matsunari, I; Nakajima, K; Nekolla, SG; Takekoshi, N; Taki, J; Tonami, N; Yoneyama, T1
Barrington, SF; Chambers, J; Hallett, WA; Nunan, TO; O'Doherty, MJ; Roxburgh, JC1
Underwood, SR1
Alkadhi, H; Gaemperli, O; Husmann, L; Kaufmann, PA; Namdar, M; Schepis, T; Siegrist, PT; Valenta, I; Wiegand, M; Wyss, CA1
Chen, LC; Chen, YK; Hsu, B; Hu, LH; Huang, WS; Hung, GU; Ting, CH; Wu, TC; Yang, BH1
Bibbo, C; Blankstein, R; Breault, C; de Souza, ACDAH; Di Carli, MF; Dorbala, S; Foley Kijewski, M; Gullberg, GT; Hainer, J; Harms, HJ; Harrington, M; Martell, L; Meretta, A; Park, MA; Poitrasson-Rivière, A; Roth, N; Soman, P; Sullivan, K; Taqueti, VR1

Trials

2 trial(s) available for technetium tc 99m sestamibi and ammonium hydroxide

ArticleYear
Myocardial distribution of (18)F-FDG and (99m)Tc-sestamibi on dual-isotope simultaneous acquisition SPET compared with PET.
    European journal of nuclear medicine and molecular imaging, 2002, Volume: 29, Issue:10

    Topics: Adult; Ammonia; Coronary Artery Disease; Female; Fluorodeoxyglucose F18; Heart Ventricles; Humans; Male; Middle Aged; Nitrogen Radioisotopes; Radiopharmaceuticals; Reproducibility of Results; Sensitivity and Specificity; Statistics as Topic; Technetium Tc 99m Sestamibi; Tissue Distribution; Tomography, Emission-Computed; Tomography, Emission-Computed, Single-Photon

2002
Comparison of sestamibi, thallium, echocardiography and PET for the detection of hibernating myocardium.
    European journal of nuclear medicine and molecular imaging, 2004, Volume: 31, Issue:3

    Topics: Adult; Aged; Ammonia; Carbon Isotopes; Echocardiography; Exercise Test; Fluorodeoxyglucose F18; Humans; Male; Middle Aged; Myocardial Stunning; Positron-Emission Tomography; Radiopharmaceuticals; Reproducibility of Results; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Thallium; Tomography, Emission-Computed, Single-Photon

2004

Other Studies

6 other study(ies) available for technetium tc 99m sestamibi and ammonium hydroxide

ArticleYear
Assessment of myocardial viability in chronic coronary artery disease using technetium-99m sestamibi SPECT. Correlation with histologic and positron emission tomographic studies and functional follow-up.
    Journal of the American College of Cardiology, 1997, Volume: 29, Issue:1

    Topics: Ammonia; Coronary Angiography; Coronary Artery Bypass; Coronary Disease; Deoxyglucose; Female; Fluorine Radioisotopes; Fluorodeoxyglucose F18; Gated Blood-Pool Imaging; Heart; Humans; Male; Middle Aged; Myocardial Contraction; Myocardium; Nitrogen Radioisotopes; Predictive Value of Tests; Prospective Studies; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed; Tomography, Emission-Computed, Single-Photon

1997
99mTc-Sestamibi SPECT is a useful technique for viability detection: results of a comparison with NH3/FDG PET.
    Scandinavian cardiovascular journal : SCJ, 2001, Volume: 35, Issue:4

    Topics: Adult; Aged; Ammonia; Cardiomyopathies; Cell Survival; Coronary Angiography; Coronary Artery Disease; Female; Fluorodeoxyglucose F18; Humans; Male; Middle Aged; Myocardium; Nitrogen Radioisotopes; Random Allocation; Stroke Volume; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon

2001
Imaging techniques in the assessment of myocardial hibernation.
    European journal of nuclear medicine and molecular imaging, 2004, Volume: 31, Issue:8

    Topics: Adult; Aged; Ammonia; Carbon Radioisotopes; Exercise Test; Fluorodeoxyglucose F18; Humans; Male; Middle Aged; Myocardial Stunning; Positron-Emission Tomography; Radiopharmaceuticals; Reproducibility of Results; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Thallium; Tomography, Emission-Computed, Single-Photon; Ultrasonography

2004
Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography.
    The international journal of cardiovascular imaging, 2008, Volume: 24, Issue:5

    Topics: Adult; Aged; Ammonia; Coronary Angiography; Coronary Circulation; Coronary Stenosis; Female; Humans; Male; Middle Aged; Myocardial Ischemia; Nitrogen Radioisotopes; Positron-Emission Tomography; Predictive Value of Tests; Radiopharmaceuticals; Sensitivity and Specificity; Severity of Illness Index; Technetium Tc 99m Sestamibi; Thallium; Tomography, Emission-Computed, Single-Photon

2008
SPECT myocardial blood flow quantitation toward clinical use: a comparative study with
    European journal of nuclear medicine and molecular imaging, 2017, Volume: 44, Issue:1

    Topics: Adult; Aged; Ammonia; Blood Flow Velocity; Coronary Artery Disease; Coronary Circulation; Female; Humans; Male; Middle Aged; Myocardial Perfusion Imaging; Nitrogen Radioisotopes; Positron-Emission Tomography; Radiopharmaceuticals; Reproducibility of Results; Sensitivity and Specificity; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon

2017
Accuracy and Reproducibility of Myocardial Blood Flow Quantification by Single Photon Emission Computed Tomography Imaging in Patients With Known or Suspected Coronary Artery Disease.
    Circulation. Cardiovascular imaging, 2022, Volume: 15, Issue:6

    Topics: Ammonia; Cadmium; Coronary Artery Disease; Coronary Circulation; Humans; Myocardial Perfusion Imaging; Positron-Emission Tomography; Reproducibility of Results; Technetium Tc 99m Sestamibi; Tomography, Emission-Computed, Single-Photon; Zinc

2022