sodium-pertechnetate-tc-99m has been researched along with ethyl-acetate* in 2 studies
2 other study(ies) available for sodium-pertechnetate-tc-99m and ethyl-acetate
Article | Year |
---|---|
A rapid chromatographic method for quality control of technetium-99m-bicisate.
The purpose of this work was to develop a simple and rapid method to determine the radiochemical purity of 99mTc-bicisate.. A rapid paper chromatographic (PC) method was developed to determine the radiochemical purity of 99mTc-bicisate and compare the results with those of the manufacturer's recommended method. The present PC method included Whatman 3MM paper as the solid phase and ethyl acetate as the solvent.. The time for chromatography by this technique was 4-5 min compared to about 23 min by the manufacturer's method. The Rf value of 99mTc-bicisate (Rf = 0.9-1.0) was widely different from those of 99mTcO4- and reduced 99mTc (Rf = 0.0 for both) so the chromatographic strip after development could be readily cut into two segments, in order to determine the labeling yield.. No significant difference in labeling yields was found between the present method and the manufacturer's method. The PC method using Whatman 3MM paper and ethyl acetate is a simple and fast technique to determine the radiochemical purity of 99mTc-bicisate and may be substituted for the manufacturer's recommended method to save time. Topics: Acetates; Chromatography, Paper; Cysteine; Organotechnetium Compounds; Oxides; Paper; Quality Control; Radiochemistry; Radiopharmaceuticals; Sodium Pertechnetate Tc 99m; Solvents; Technetium; Technetium Compounds; Time Factors | 1997 |
Rapid miniaturized chromatography for technetium-99m-tetrofosmin.
The purpose of this investigation was to develop and evaluate a new and rapid miniaturized chromatography system that would accurately assess the radiochemical purity of 99mTc-tetrofosmin without the problems of solvent ratios and time requirements associated with the manufacturer's recommended procedure.. The migration of the radiochemical components of 99mTc-tetrofosmin was evaluated using various chromatography media with ethyl acetate as the solvent. After optimization of the miniaturized system, radiochemical purity assessments were performed simultaneously on 23 99mTc-tetrofosmin preparations using both recommended and miniaturized chromatography systems.. A miniaturized chromatography system consisting of Whatman 1 chromatography paper with ethyl acetate was developed for the radiochemical purity assessment of 99mTc-tetrofosmin. Radiochemical purity results for 99mTc-tetrofosmin preparations were similar with both recommended and miniaturized chromatography methods, with a mean difference of 1.5% +/- 1.2% (s.d.). Differences in radiochemical purity results between the two chromatography systems were less than 2% (20 of 23 evaluations) with most preparations.. Radiochemical purity results for 99mTc-tetrofosmin preparations were similar with both the manufacturer's recommended chromatography and miniaturized chromatography systems. The miniaturized chromatography system is easier to use, and the time required to perform radiochemical purity assessments is substantially reduced. Topics: Acetates; Chromatography, Paper; Microchemistry; Micromanipulation; Miniaturization; Organophosphorus Compounds; Organotechnetium Compounds; Paper; Quality Control; Radiochemistry; Radiopharmaceuticals; Sodium Pertechnetate Tc 99m; Solvents; Technetium; Time Factors | 1997 |