sirolimus has been researched along with umirolimus* in 227 studies
14 review(s) available for sirolimus and umirolimus
Article | Year |
---|---|
True double bifurcation lesions: new application of the self-expandable Axxess stent and review of literature with dedicated bifurcation devices.
Complex coronary artery bifurcation lesions occurred in hard clinical scenarios, such as acute coronary syndromes, may represent a challenge for interventional cardiologists, with not-defined general consensus on treatment. Even if provisional stenting is the most common option used to restore rapidly the coronary branches flow, improvements in industrial technologies and design of new dedicated bifurcation devices might open new modalities of treatment in these complex cases. The Axxess stent (Biosensors Europe SA, Morges, Switzerland) is a self-expanding biolimus-eluting conical V-shape stent, specifically designed to treat "easily" coronary artery bifurcation lesions, with reported favorable long-term clinical results in stable patients compared to a provisional technique. We report for the first time the feasibility to use this device in a case of "true double coronary bifurcation lesion" occurred in the context of acute coronary syndrome. Moreover, we reviewed studies with bifurcation dedicated devices and available cases of "true double bifurcation lesions", underlying advantages/disadvantages of using one device over the others during acute coronary syndrome. Topics: Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Humans; Male; Prosthesis Design; Sirolimus; Treatment Outcome | 2019 |
A mixed treatment comparison for short- and long-term outcomes of bare-metal and drug-eluting coronary stents.
The increasing use of drug eluting stents in interventional cardiology calls for assessment of their efficacy and safety, both among drug-eluting and bare-metal stents, in the context of rational decision making.. We searched for papers that compared any of the sirolimus-eluting stent, paclitaxel-eluting stent, drug- eluting stent, biodegradable stent, everolimus-eluting stent, zotarolimus-resolute eluting stent, biolimus- eluting stent, bare-metal stent and zotarolimus-eluting stent. The search was contacted through Medline, the Cochrane database, Embase, TCTMD, ClinicalTrials.gov, Clinical Trial Results, CardioSource, abstracts and presentations from major cardiovascular meetings. We also searched for further articles cited by selected papers. Furthermore, important conferences and relevant proceedings and abstracts, such as the American Heart Association, American College of Cardiology, Transcatheter Cardiovascular Therapeutics, Society of Cardiovascular Angiography and Intervention, European Society of Cardiology, and Euro-PCR, were also searched. Inclusion criteria were: randomised controlled trials (RCTs), size of study (≥100 patients), duration more than 6 months and definition of reported endpoints (target vessel revascularization, thrombosis, myocardial infarction and cardiac death). Analysis of the data was performed for short-term (less than a year) and long-term outcomes (more than a year). A mixed treatment comparison approach was utilised for the data analysis.. Based on the rankings of each treatment, a distinct difference between the 2nd and 1st generation stents was identified. We can conclude that everolimus, zotarolimus-resolute and biolimus eluting stents carry the highest probabilities of being superior for all endpoints. Topics: Aged; Aged, 80 and over; Antineoplastic Agents, Phytogenic; Death; Drug-Eluting Stents; Everolimus; Humans; Immunosuppressive Agents; Male; Metals; Middle Aged; Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Stents; Thrombosis; Treatment Outcome | 2016 |
Impact of side branch stenting on five-year long-term clinical outcome with the bifurcation-dedicated Axxess Biolimus A9-eluting stent system.
Our aim was to evaluate the five-year clinical impact of side branch (SB) stenting with a drug-eluting stent (DES) following Axxess stent implantation in coronary bifurcation lesions.. Four hundred patients treated with Axxess were pooled from the AXXESS Plus and DIVERGE five-year follow-up studies. We compared unadjusted and propensity-adjusted major adverse clinical events (MACE) between Axxess with no SB stenting ("Axxess provisional") versus Axxess with SB stenting ("Axxess additional"). "Axxess additional" had no impact on the MACE rate, with unadjusted and adjusted HR 1.59 (95% CI: 0.95-2.64) and 1.37 (95% CI: 0.88-2.13), respectively. No differences were seen in the individual components of death, myocardial infarction and ischaemia-driven target lesion revascularisation, respectively, both in unadjusted (HR 0.92 [95% CI: 0.38-2.19]; HR 1.73 [95% CI: 0.78-3.82]; HR 1.65 [95% CI: 0.84-3.26]) and adjusted analysis (HR 0.92 [95% CI: 0.41-2.09]; HR 1.13 [95% CI: 0.59-2.17]; HR 1.31 [95% CI: 0.74-2.31]). No differences in definite stent thrombosis were seen with unadjusted HR 2.1 (95% CI: 0.45-9.88) and adjusted HR 1.0 (95% CI: 0.32-3.1).. Stenting the SB following Axxess implantation does not impact on long-term clinical outcomes compared to MV stenting only. The Axxess stent system offers a safe and tailored alternative for the treatment of coronary bifurcation lesions. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Logistic Models; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFO
This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).. Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Recurrence; Risk Assessment; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2014 |
The Nobori biolimus-eluting stent: update of available evidence.
Despite first-generation drug-eluting stents (DES) dramatically reduced the need for repeat revascularization in patients undergoing percutaneous coronary intervention, their use was associated with an increased risk of thrombotic events at long-term follow-up. The Nobori biolimus-eluting stent (BES) is a second-generation DES with a biodegradable poly-lactic acid polymer. During the last few years, several randomized trials have compared the Nobori BES with other DES, making this device the most investigated biodegradable DES. In this article, we reviewed current available data about Nobori BES from pharmacokinetic and observational studies to randomized clinical trials. Topics: Animals; Cell Proliferation; Drug Carriers; Drug Evaluation, Preclinical; Drug-Eluting Stents; Humans; Randomized Controlled Trials as Topic; Sirolimus | 2014 |
NOBORI™ biodegradable-polymer biolimus-eluting stent versus durable-polymer drug-eluting stents: a meta-analysis.
Topics: Absorbable Implants; Drug-Eluting Stents; Humans; Polymers; Prosthesis Design; Sirolimus | 2014 |
Clinical outcomes of patients treated with Nobori biolimus-eluting stent: Meta-analysis of randomized trials.
The Nobori is a new-generation, biodegradable-polymer coated, biolimus-eluting stent (BES) that has recently been investigated in several randomized trials with inconsistent results. The aim of this study was to assess the efficacy and safety of Nobori BES versus other drug-eluting stents (DES) in patients treated with percutaneous coronary intervention (PCI).. We undertook a meta-analysis of randomized trials investigating Nobori BES versus other DES. Primary efficacy and safety outcomes were target lesion revascularization (TLR) and definite/probable stent thrombosis (ST), respectively. Secondary outcomes were the composite of cardiac death/myocardial infarction (MI)/target vessel revascularization (TVR), MI and death.. A total of 9114 PCI-patients randomly received Nobori BES (n=5080) or other DES (n=4034). This latter group comprised patients receiving everolimus- (n=2533), sirolimus- (n=1376) or paclitaxel-eluting stents (n=125). Median follow-up was 11 months [interquartile range 9-12]. The Nobori BES versus other DES showed comparable risk of TLR (odds ratio [95% confidence interval]=0.91 [0.57-1.46], p=0.71). There was significant heterogeneity across trials due to significant lower TLR risk with Nobori BES versus paclitaxel-eluting stent (0.32 [0.10-0.98], p=0.046; p for interaction=0.009). Nobori BES versus other DES showed comparable risk of definite/probable ST (1.40 [0.66-2.97], p=0.39), cardiac death/MI/TVR (1.05 [0.88-1.25], p=0.59), MI (1.13 [0.87-1.48], p=0.37) and death (1.09 [0.81-1.48], p=0.56).. Nobori BES has comparable efficacy with other limus-eluting stents at 1-year follow-up. There is no difference in terms of safety profile between these stent platforms. Topics: Coronary Artery Disease; Drug-Eluting Stents; Follow-Up Studies; Humans; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Treatment Outcome | 2014 |
Long-term outcomes of biodegradable polymer versus durable polymer drug-eluting stents in patients with diabetes a pooled analysis of individual patient data from 3 randomized trials.
There is ongoing debate on the optimal drug-eluting stent (DES) in diabetic patients with coronary artery disease. Biodegradable polymer drug-eluting stents (BP-DES) may potentially improve clinical outcomes in these high-risk patients. We sought to compare long-term outcomes in patients with diabetes treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).. We pooled individual patient-level data from 3 randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4 and LEADERS) comparing biodegradable polymer DES with durable polymer SES. Clinical outcomes out to 4 years were assessed. The primary end point was the composite of cardiac death, myocardial infarction and target-lesion revascularization. Secondary end points were target lesion revascularization and definite or probable stent thrombosis.. Of 1094 patients with diabetes included in the present analysis, 657 received biodegradable polymer DES and 437 durable polymer SES. At 4 years, the incidence of the primary end point was similar with BP-DES versus SES (hazard ratio = 0.95, 95% CI = 0.74-1.21, P = 0.67). Target lesion revascularization was also comparable between the groups (hazard ratio = 0.89, 95% CI = 0.65-1.22, P = 0.47). Definite or probable stent thrombosis was significantly reduced among patients treated with BP-DES (hazard ratio = 0.52, 95% CI = 0.28-0.96, P = 0.04), a difference driven by significantly lower stent thrombosis rates with BP-DES between 1 and 4 years (hazard ratio = 0.15, 95% CI = 0.03-0.70, P = 0.02).. In patients with diabetes, biodegradable polymer DES, compared to durable polymer SES, were associated with comparable overall clinical outcomes during follow-up to 4 years. Rates of stent thrombosis were significantly lower with BP-DES. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Diabetes Complications; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Multicenter Studies as Topic; Polymers; Randomized Controlled Trials as Topic; Risk Assessment; Sirolimus; Thrombosis; Treatment Outcome | 2013 |
The relationship between late lumen loss and restenosis among various drug-eluting stents: a systematic review and meta-regression analysis of randomized clinical trials.
To relate late lumen loss (LLL) after drug-eluting stent (DES) implantation to angiographic (BAR) and target vessel revascularization (TVR) in randomized clinical trials of DES.. We reviewed all clinical trials comparing different DES and having protocol-driven angiographic follow-up. We combined the data in a meta-regression analysis correlating LLL with BAR or TVR, with and without adjustment for diabetes mellitus, lesion length or reference vessel diameter. There were 15,846 patients in 29 trials (9 DES platforms) and 8697 had angiographic follow-up at a mean of 8 months. The mean age was 63 y, 28% were women and 33% had diabetes mellitus. Mean weighted in-segment LLL was 0.232mm (0.228-0.235mm), significantly higher in paclitaxel- and zotarolimus-eluting stents than in sirolimus-, everolimus- or biolimus-eluting stents. LLL was monotonically related to BAR (BAR=0.30×LLL+0.02, R(2)=0.53, P<0.0001) and TVR (TVR=0.20×LLL+0.02, R(2)=0.46, P<0.0001). Two thirds of patients with BAR had TVR. LLL remained significantly associated with BAR and TVR after multivariable adjustment. Reference vessel diameter and diabetes mellitus were inversely related to BAR.. LLL is a strong, monotonically related predictor of BAR and TVR. There is no evidence of threshold phenomenon in these relationships. Topics: Aged; Angiography; Diabetes Complications; Diabetes Mellitus; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Paclitaxel; Randomized Controlled Trials as Topic; Regression Analysis; Sirolimus | 2011 |
[Types and characteristic features of drug-eluting stents].
Types and characteristics of current-available drug-eluting stents(DES) are introduced in this review. Currently, DESs with agents of "limus family" are mainly used because of their efficacy and safety. Two representative performances, angiographic late loss and incidence of late acquired incomplete stent apposition, are compared between these DESs. Furthermore, patient-to-patient variation in amount of neointimal hyperplasia, which is chiefly associated with clinical outcomes, tends to be larger for the DES with larger average angiographic late loss. Thrombotic complications are unexpectedly more frequent in the DES with larger late loss within first one year according to the randomized clinical trials, however, persistent influences to vascular wall become dominant factors stent thrombosis at very late phases. Topics: Angioplasty, Balloon, Coronary; Antineoplastic Agents; Drug-Eluting Stents; Everolimus; Paclitaxel; Randomized Controlled Trials as Topic; Sirolimus; Thrombosis | 2011 |
[Biolimus eluting stent].
Topics: Coronary Disease; Drug-Eluting Stents; Humans; Sirolimus | 2011 |
Drug-eluting stents - what should be improved?
Despite the success of drug-eluting stents (DES) in reducing restenosis and the need for target vessel revascularization, several deficiencies have been unraveled since their first clinical application including the risk of stent thrombosis, undesired effects due to the stent polymer as well as the stent itself, and incomplete inhibition of restenosis (especially in complex lesions). Several novel stent systems are being investigated in order to address these issues. In second-generation DES, the rapamycin analogues zotarolimus and everolimus (and more recently biolimus) have been most extensively studied. Furthermore, special stent-coatings to actively promote endothelial healing (in order to reduce the risk of stent thrombosis) and to further reduce restenosis have been employed. To avoid undesirable effects of currently applied (durable) polymers, biocompatible and bioabsorbable polymers as well as DES delivery systems without the need for a polymer have been developed. Bioabsorbable stents, both polymeric and metallic, were developed to decrease potential late complications after stent implantation. Although most of these innovative novel principles intuitively seem appealing and demonstrate good results in initial clinical evaluations, long-term large-scale studies are necessary in order to reliably assess whether these novel systems are truly superior to first-generation DES with respect to safety and efficacy. Topics: Coated Materials, Biocompatible; Coronary Restenosis; Coronary Vessels; Drug Delivery Systems; Drug-Eluting Stents; Everolimus; Humans; Polymers; Sirolimus; Thrombosis | 2008 |
Future stent drug delivery systems.
Drug-eluting stents (DES) with antiproliferative drugs attached via polymers on the stent surface have reduced in-stent restenosis and repeat revascularization compared with bare metal stent (BMS) across nearly all lesion and patient subsets. However, the small number of patients with in-stent restenosis after DES treatment still exists. Furthermore, concerns about long-term safety of DES are raised, particularly regarding the higher-than-expected late-event thrombosis. There is no doubt that the DES will continue to play a pivotal role in the treatment of coronary artery disease, yet future designs need to incorporate features that reduce thrombosis and promote endothelialization along with maintaining the efficacy. This review focuses on novel generation of DES, discussing new programs, including new antiproliferative agents, novel polymeric and non polymeric stents. Topics: Absorbable Implants; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Equipment Design; Everolimus; Evidence-Based Medicine; Humans; Immunosuppressive Agents; Polymers; Prosthesis Design; Sirolimus; Tacrolimus | 2008 |
BioMatrix Biolimus A9-eluting coronary stent: a next-generation drug-eluting stent for coronary artery disease.
Drug-eluting stent technology consisting of a bare metal stent, carrier coating, bioactive drug and delivery system, offers an almost infinite range of possible device configurations. A growing understanding of the mechanisms of restenosis allows for the design of synergistic functions within these components, thus providing a basis for new and improved products. The BioMatrix stent (Biosensors Interventional Technologies Pte Ltd., Singapore) elutes the new sirolimus derivative Biolimus A9 from a biodegradable polylactic acid polymer. Biolimus A9 possesses enhanced anti-inflammatory and antiproliferative activity with an improved pharmacokinetic profile. Permanent polymer-carrier-based platforms may be associated with inflammation, late thrombosis and restenosis. The BioMatrix, with its asymmetric and abluminal coating, releases Biolimus A9 into the vessel wall while the polylactic acid polymer is resorbed by surrounding tissues. Clinical studies have demonstrated the BioMatrix to be well tolerated and effective, and it has now become the subject of an aggressive clinical program. Topics: Animals; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Restenosis; Drug Carriers; Drug Delivery Systems; Humans; Lactic Acid; Polyesters; Polymers; Randomized Controlled Trials as Topic; Sirolimus; Stents | 2006 |
96 trial(s) available for sirolimus and umirolimus
Article | Year |
---|---|
Stent strut thickness and acute vessel injury during percutaneous coronary interventions: an optical coherence tomography randomized clinical trial.
Compare the degree of acute vascular injury caused by a polymer-free, thin-strut drug-eluting stent (DES) to that caused by a bioresorbable polymer, thick-strut DES using optical coherence tomography (OCT).. Fifty patients requiring nonurgent PCI were randomized to receive either a thin or a thick-strut DES. OCT was performed before and after stent implantation. OCT-based injury score (IS) after implantation was numerically higher within thick-strut stents 0.32 vs. 0.23, but the difference was NS (P = 0.61). Edge dissections were present in 36% of the patients without differences between groups. Tissue prolapse (TP) area was larger with thin-strut stents (2.26 vs. 1.83 mm2, P = 0.04). Stent expansion and symmetry index were similar between the two platforms (85% vs. 94%, P = 0.08; and 0.82 vs. 0.80, P = 0.25). No differences were observed in total malapposition area (1.85 mm2 in thin-strut stents vs. 1.47 mm2, P = 0.48). Regarding the influence of plaque-type, IS tended to be higher (non-significant) with thick strut DES in fibrocalcific plaques. Stent malapposition area was smaller in fibrous plaques, especially with thin strut stents (P = 0.03).. There was no difference in the extent of OCT-based vessel injury associated with thin and thick-strut DES platforms. TP was larger with the thin strut DES, potentially reflecting a deeper stent embedment in the vessel wall. Topics: Aged; Biodegradable Plastics; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Intraoperative Complications; Male; Outcome Assessment, Health Care; Percutaneous Coronary Intervention; Plaque, Atherosclerotic; Sirolimus; Tomography, Optical Coherence; Vascular System Injuries | 2021 |
Impact of established cardiovascular disease on outcomes in the randomized global leaders trial.
To investigate the impact of different anti-platelet strategies on outcomes after percutaneous coronary intervention (PCI) in patients with established cardiovascular disease (CVD).. GLOBAL LEADERS was a randomized, superiority, all-comers trial comparing one-month dual anti-platelet therapy (DAPT) with ticagrelor and aspirin followed by 23-month ticagrelor monotherapy (experimental treatment) with standard 12-month DAPT followed by 12-month aspirin monotherapy (reference treatment) in patients treated with a biolimus A9-eluting stent. Established CVD was defined as ≥1 prior myocardial infarction, PCI, coronary artery bypass operation, stroke, or established peripheral vascular disease. The primary endpoint was a composite of all-cause death or new Q-wave MI at 2-years. The secondary safety endpoint was BARC 3 or 5 bleeding. Exploratory secondary endpoints were the patient-orientated composite endpoint and net adverse clinical events.. Among the 15,761 patients in this cohort were 6,693 patients (42.5%) with established CVD. Compared to those without established CVD, these patients had significantly higher rates of the primary (5.1 vs. 3.3%, HR1.59[1.36-1.86], p < .001) and secondary composite endpoints with no significant differences in bleeding. There was a nonsignificant reduction in the primary endpoint in patients with established CVD receiving the experimental treatment (4.6 vs. 5.6%, HR0.82[0.66-1.02], p = .07). When comparing patients without CVD to those with one or three territories of CVD, the hazard ratio for the primary endpoint increased in unadjusted and adjusted models.. The poorer outcomes in patients with established CVD are not mitigated by prolonged monotherapy with a potent P2Y12 inhibitor suggesting a greater need to focus on modifiable risk factors. Topics: Aged; Aspirin; Drug Administration Schedule; Drug-Eluting Stents; Dual Anti-Platelet Therapy; Female; Heart Disease Risk Factors; Humans; Male; Middle Aged; Myocardial Ischemia; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prospective Studies; Purinergic P2Y Receptor Antagonists; Recurrence; Risk Assessment; Sirolimus; Ticagrelor; Time Factors; Treatment Outcome | 2020 |
Polymer-based or Polymer-free Stents in Patients at High Bleeding Risk.
Polymer-free drug-coated stents provide superior clinical outcomes to bare-metal stents in patients at high bleeding risk who undergo percutaneous coronary intervention (PCI) and are treated with 1 month of dual antiplatelet therapy. Data on the use of polymer-based drug-eluting stents, as compared with polymer-free drug-coated stents, in such patients are limited.. In an international, randomized, single-blind trial, we compared polymer-based zotarolimus-eluting stents with polymer-free umirolimus-coated stents in patients at high bleeding risk. After PCI, patients were treated with 1 month of dual antiplatelet therapy, followed by single antiplatelet therapy. The primary outcome was a safety composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year. The principal secondary outcome was target-lesion failure, an effectiveness composite of death from cardiac causes, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. Both outcomes were powered for noninferiority.. A total of 1996 patients at high bleeding risk were randomly assigned in a 1:1 ratio to receive zotarolimus-eluting stents (1003 patients) or polymer-free drug-coated stents (993 patients). At 1 year, the primary outcome was observed in 169 of 988 patients (17.1%) in the zotarolimus-eluting stent group and in 164 of 969 (16.9%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% confidence interval [CI], 3.5; noninferiority margin, 4.1; P = 0.01 for noninferiority). The principal secondary outcome was observed in 174 patients (17.6%) in the zotarolimus-eluting stent group and in 169 (17.4%) in the polymer-free drug-coated stent group (risk difference, 0.2 percentage points; upper boundary of the one-sided 97.5% CI, 3.5; noninferiority margin, 4.4; P = 0.007 for noninferiority).. Among patients at high bleeding risk who received 1 month of dual antiplatelet therapy after PCI, use of polymer-based zotarolimus-eluting stents was noninferior to use of polymer-free drug-coated stents with regard to safety and effectiveness composite outcomes. (Funded by Medtronic; ONYX ONE ClinicalTrials.gov number, NCT03344653.). Topics: Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Heart Diseases; Hemorrhage; Humans; Immunosuppressive Agents; Kaplan-Meier Estimate; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prosthesis Design; Single-Blind Method; Sirolimus | 2020 |
Clinical outcomes three-year after revascularization with biodegradable polymer stents: ultrathin-strut sirolimus-eluting stent versus biolimus-eluting stent: from the Scandinavian organization for randomized trials with clinical outcome VII trial.
Drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. However, drug-eluting stents with biodegradable polymers may not be a class effect, as stent strut thickness, polymer coating, and drug resorption differ between these groups of stents. Twelve months results of Scandinavian Organization for Randomized Trials With Clinical Outcome VII showed that ultrathin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent. The sirolimus-eluting Orsiro stent was associated with a reduced risk of definite stent thrombosis.. The Scandinavian Organization for Randomized Trials With Clinical Outcome VII trial is a prospective multicenter randomized clinical trial comparing sirolimus-eluting Orsiro stent and biolimus-eluting Nobori stent in all-comers patients. The endpoint target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion) and target lesion revascularization.. A total of 1261 patients were randomized to treatment with sirolimus-eluting Orsiro stent and 1264 patients to biolimus-eluting Nobori stent and followed for 3 years. At 3-year the target lesion failure was comparable for sirolimus-eluting Orsiro stent (9.0%) and the biolimus-eluting Nobori stent (9.1%), (rate ratio, 0.99; 95% confidence interval, 0.77-1.29). Cardiac death (sirolimus-eluting Orsiro stent 3.0% vs. biolimus-eluting Nobori stent 2.6% [rate ratio, 1.16; 95% confidence interval, 0.73-1.86]), target lesion revascularization (sirolimus-eluting Orsiro stent 5.2% vs. biolimus-eluting Nobori stent 5.9% [rate ratio, 0.90; 95% confidence interval, 0.64-1.25]), myocardial infarction (sirolimus-eluting Orsiro stent 4.7% vs. biolimus-eluting Nobori stent 4.5% [rate ratio, 1.04; 95% confidence interval, 0.72-1.50]), and definite stent thrombosis (sirolimus-eluting Orsiro stent 1.0% vs. biolimus-eluting Nobori stent 1.7% [rate ratio, 0.59; 95% confidence interval, 0.30-1.18]) did not differ significantly between the two groups.. At 3-year follow-up, target lesion failure did not differ among ultrathin-strut sirolimus-eluting Orsiro stent and biolimus-eluting Nobori stent with biodegradable polymers. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Revascularization; Polymers; Prospective Studies; Prosthesis Design; Single-Blind Method; Sirolimus; Time Factors; Treatment Outcome | 2020 |
Randomized Comparison of the Polymer-Free Biolimus-Coated BioFreedom Stent With the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Orsiro Stent in an All-Comers Population Treated With Percutaneous Coronary Intervention: The SORT OUT IX Trial.
In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.. The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021.. Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%];. The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140. Topics: Absorbable Implants; Aged; Anti-Inflammatory Agents; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Incidence; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Sirolimus; Treatment Outcome | 2020 |
Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial.
Given the characteristic differences between intravascular ultrasound (IVUS) and optical frequency domain imaging (OFDI), their approach to therapeutic guidance during percutaneous coronary interventions (PCIs) and arterial healing response after stenting may also vary.. MISTIC-1 (The Multimodality Imaging Study in Cardiology cohort 1) is a multicenter, randomized-controlled, noninferiority trial that compared imaging end points between OFDI- and IVUS-guided PCI. Patients with stable coronary artery disease were randomly assigned to either OFDI- or IVUS-guided PCI using a Biolimus A9-eluting stent according to a prespecified protocol for imaging guidance. Stent sizing was based on external elastic lamina in IVUS-guided PCI while lumen up-size in OFDI-guided PCI. Postprocedural OFDI was investigated regardless of randomization, while operators in IVUS-guided PCI arm were blinded to the images. The primary end point was in-segment minimum lumen area assessed using OFDI at 8 months, while the secondary end point was a composite of cardiovascular mortality, target-vessel myocardial infarction, or target-lesion revascularization (device-oriented composite end point). Patients were followed up to 3 years after the index procedure.. OFDI-guided PCI was not inferior to IVUS-guided PCI in terms of in-segment minimum lumen area at 8 months. Although a small sample size was acknowledged, OFDI could be an alternative to IVUS when considering intracoronary imaging-guided PCI in selected populations with coronary artery diseases. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03292081. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Japan; Male; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2020 |
Impact of diabetes on clinical outcomes after revascularization with sirolimus-eluting and biolimus-eluting stents with biodegradable polymer from the SORT OUT VII trial.
In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared.. Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention.. In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years.. At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95).. TLF did not differ between O-SES- and N-BES-treated diabetic patients. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Randomized comparison between 2-link cell design biolimus A9-eluting stent and 3-link cell design everolimus-eluting stent in patients with de novo true coronary bifurcation lesions: the BEGIN trial.
The appropriate stent platform for treating coronary bifurcation lesions (CBLs) remains controversial. Previous bench tests have demonstrated the superiority of a 2-link cell design to 3-link cell design for creating inter-strut dilation at the side branch ostium. This randomized multicenter prospective BEGIN trial compared the biodegradable polymer-based biolimus A9-eluting stent (2-link BES) with the durable polymer-based cobalt chromium everolimus-eluting stent (3-link EES) in 226 patients with de novo CBLs. Patients with true bifurcations, defined as > 50% stenosis in the main vessel and side branch (SB) and an SB diameter > 2.25 mm, were enrolled. Guide wire re-crossing to the distal cell (near the carina) in the jailed SB and final kissing inflation were recommended. The SB angiographic endpoint was < 50% stenosis diameter. Left-main CBLs (13.5% vs. 13.0%) and 2-stent technique (30.6% vs. 22.6%) rates were similar. The primary endpoints (minimum lumen diameter at the SB ostium measured at an independent core laboratory at the 8-month follow-up) were comparable (1.64 ± 0.50 mm vs. 1.63 ± 0.51 mm, p = 0.976). There was no significant difference in composite outcomes of cardiac death, myocardial infarction, or target vascular revascularization at 12 months (7.4% vs. 8.0%, p = 0.894). Two-link BES and 3-link EES showed similar 8-month angiographic and 1-year clinical outcomes for true CBLs. Topics: Absorbable Implants; Aged; Aged, 80 and over; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Japan; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention: A Randomized Noninferiority Trial With 1-Year Follow-Up (SORT OUT VIII Trial).
The aim of this study was to compare the thin-strut biodegradable-polymer everolimus-eluting platinum-chromium stent (EES) with the biodegradable-polymer biolimus-eluting stainless-steel stent (BES).. Currently available drug-eluting coronary stents have been refined to reduce the risk for coronary events following implantation.. This randomized, multicenter, all-comers, noninferiority trial was undertaken at 3 sites in western Denmark. Patients with clinical indications for percutaneous coronary intervention were eligible for inclusion. Patients were randomly assigned (1:1) to either EES or BES. The primary endpoint, target lesion failure, was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a nontarget lesion) and efficacy (target lesion revascularization) at 12 months, analyzed using intention-to-treat principles. The trial was powered to assess target lesion failure noninferiority of the EES compared with the BES with a predetermined noninferiority margin of 3%.. A total of 1,385 patients were assigned to treatment with EES and 1,369 patients to treatment with BES. The analysis showed that 55 patients (4.0%) assigned to the EES and 60 (4.4%) assigned to the BES met the primary endpoint (absolute risk difference 0.4%; upper limit of 1-sided 95% confidence interval: 1.7%; p < 0.001).. At 1-year follow-up, the EES was found to be noninferior to the BES with respect to target lesion failure. (Everolimus-eluting SYNERGY Stent Versus Biolimus-Eluting Biomatrix NeoFlex Stent-SORT-OUT VIII; NCT02093845). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Denmark; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Comparison of the polymer-free biolimus-coated BioFreedom stent with the thin-strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population treated with percutaneous coronary intervention: Rationale and design of the randomized SO
In patients with increased bleeding risk during dual antiplatelet therapy, the biolimus A9-coated BioFreedom, a stainless steel drug-coated stent devoid of polymer, has shown superiority compared to a bare-metal stent. The aim of this study was to investigate whether the polymer-free biolimus A9-coated BioFreedom is noninferior to a modern thin-strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention.. The multicenter SORT OUT IX trial (NCT02623140) randomly assigned all-comers patients to treatment with the BioFreedom drug-coated stent or the biodegradable polymer Orsiro stent in 4 Danish University Hospitals. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically driven event detection based on Danish registries will be used and continue through 5 years. Assuming an event rate of 4.2% in each stent group, 1,563 patients in each treatment arm will provide 90% power to detect noninferiority of the drug-coated BioFreedom stent with a noninferiority margin of 2.1%.. A total of 3,150 patients have been randomized and enrolled in the study.. The SORT OUT IX trial will determine whether the drug-coated BioFreedom stent is noninferior to a modern biodegradable polymer Orsiro stent. Topics: Absorbable Implants; Cause of Death; Chromium Alloys; Coronary Stenosis; Denmark; Drug-Eluting Stents; Equipment Design; Humans; Immunosuppressive Agents; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Sirolimus; Time Factors | 2019 |
Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus: 5 years follow-up from the COMPARE II trial.
Drug eluting stents with biodegradable polymers have been developed to address the risk of very late adverse events. Long-term comparison data between the biodegradable polymer-coated biolimus-eluting stent (BES; Nobori®) and the second-generation durable polymer-coated everolimus-eluting stent (EES; XIENCE V® or XIENCE PRIME® or PROMUS™) in diabetic patients are scarce.. The COMPARE II trial was an investigator-initiated, multicenter, open-label, randomized, all-comers trial which assigned patients undergoing percutaneous coronary intervention (PCI) in a 2:1 fashion to either BES or EES. We analyzed the safety and efficacy outcomes in diabetic patients at 5 year follow-up. The primary pre-specified composite endpoint major adverse cardiac event (MACE) was defined as cardiac death, non-fatal target-vessel myocardial infarction (TV-MI), or clinically indicated target vessel revascularization (CD-TVR).. Out of 2707 study patients, 588 were diabetics (21.7%) of whom 391 were treated with BES and 197 with EES. At 5 years follow-up, MACE occurred in 87 patients (22.2%) in the BES group and in 34 patients (17.2%) in the EES group (p = .34). Other safety and efficacy endpoints did not differ between stent groups.. At 5 years follow-up, no differences in terms of MACE as well as all analyzed safety and efficacy measures, including stent thrombosis, between the biodegradable polymer-coated BES and the durable polymer-coated EES in diabetic patients were observed. Topics: Absorbable Implants; Aged; Aged, 80 and over; Diabetes Mellitus; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Sirolimus; Time Factors | 2019 |
Everolimus-Eluting Versus Biolimus-Eluting Coronary Stent Implantation in Patients With and Without Diabetes Mellitus.
Diabetes mellitus is associated with a higher risk of target lesion revascularization after percutaneous coronary intervention. We compared clinical outcomes in patients with and without diabetes mellitus, treated with everolimus-eluting stents (EES; Synergy; Boston Scientific, Marlborough, Massachusetts) or biolimus-eluting stents (BES; BioMatrix NeoFlex; Biosensors Interventional Technologies Pte Ltd., Singapore). In total, 2,764 patients were randomized to stent implantation with EES (n = 1,385, diabetes: n = 250) or the BES (n = 1,379, diabetes: n = 262), stratified by gender and diabetes. The primary end point, target lesion failure (TLF), was a composite of cardiac death, target-lesion myocardial infarction, or target lesion revascularization at 12 months. Secondary end points included individual components of TLF, all-cause death, and stent thrombosis. TLF was 2.1% lower in the EES versus the BES groups in patients with diabetes (3.6% vs 5.7%; rate ratios 0.61, 95% confidence interval [CI] 0.27 to 1.41) and similar in patients without diabetes (4.1% vs 4.0%; rate ratios 0.99, 95% CI 0.66 to 1.51). In patients with diabetes, the point estimates of the individual components of TLF also favored the EES but CIs were wide. No interaction between stent type and presence of diabetes was found. The current subgroup analysis found that a thin-strut EES as compared with a thicker strut BES had a numerically lower TLF rate in patients with diabetes, but the subgroup analysis was underpowered for definite conclusions. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Confidence Intervals; Coronary Angiography; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Odds Ratio; Percutaneous Coronary Intervention; Reference Values; Risk Assessment; Severity of Illness Index; Sirolimus; Survival Rate; Treatment Outcome | 2019 |
Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study.
To show non-inferiority of the 67- or 87 µm thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 µm thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up.. This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Δ = 0.60 mm2) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro (n = 60) or Nobori (n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm2, but increased to 0.82 mm2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm2 [0.02;0.30] mm2, Nobori: 0.03 mm2 [0.00;0.17] mm2, P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98,6]% (P = 0.13).. Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution of neointima but stent strut coverage did not differ significantly between the two stents. Topics: Absorbable Implants; Angioplasty, Balloon, Coronary; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Neointima; Normal Distribution; Polymers; Prospective Studies; Prosthesis Design; Reference Values; Risk Assessment; Severity of Illness Index; Sirolimus; Statistics, Nonparametric; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Vascular Patency | 2018 |
Two-year outcome after biodegradable polymer sirolimus- and biolimus-eluting coronary stents (from the randomised SORT OUT VII trial).
Topics: Absorbable Implants; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Second-Generation vs. First-Generation Drug-Eluting Stents in Patients With Calcified Coronary Lesions - Pooled Analysis From the RESET and NEXT Trials.
The comparative efficacy of second-generation (G2) vs. first-generation (G1) drug-eluting stents (DES) for calcified coronary lesions is unknown.Methods and Results:We compared the 3-year clinical outcomes of patients with G1- or G2-DES according to the presence or absence of calcified coronary lesions as assessed in an angiographic core laboratory using data from 2 large-scale prospective multicenter randomized trials, RESET and NEXT. G1-DES and G2-DES were implanted in 299 and 1,033 patients, respectively, in the Calc stratum (≥1 lesion with moderate/severe calcification), and 1,208 and 3,550 patients, respectively, in the Non-calc stratum (no/mild calcification). The patients in the Calc stratum had a significantly higher adjusted risk for the primary outcome measure (any target-lesion revascularization (TLR)) than those in the Non-calc stratum (HR: 1.38, 95% CI: 1.11-1.71, P=0.004). The cumulative 3-year incidence of any TLR was not significantly different between the G1-DES and G2-DES groups in both the Calc and Non-calc strata (12.1% vs. 9.7%, P=0.22, and 6.8% vs. 6.1%, P=0.44, respectively). After adjusting for confounders, the effect of G2DES relative to G1-DES for any TLR remained insignificant in both the Calc and Non-calc strata (HR: 0.78, 95% CI: 0.48-1.25, P=0.3, and HR: 0.84, 95% CI: 0.61-1.17, P=0.31, respectively, P interaction=0.55).. The effect of G2-DES relative to G1-DES for TLR was not significantly different regardless of the presence or absence of lesion calcification. Topics: Aged; Calcinosis; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Revascularization; Sirolimus; Treatment Outcome | 2018 |
Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy.
There are few randomised studies concerning the optimal duration of dual antiplatelet therapy (DAPT) for patients who receive a second-generation drug-eluting stent (DES). This trial aimed to investigate the safety of six-month compared with 12-month DAPT maintenance after second-generation DES implantation.. A prospective, randomised, multicentre trial was performed at 10 medical centres. The 1,368 patients included in the study received a biolimus-eluting stent (BES) or a zotarolimus-eluting stent (ZES). The primary outcome measured was the composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), or ischaemia-driven target lesion revascularisation at the 12-month follow-up. The secondary outcome was the percentage of uncovered struts at six months in 60 patients (30 ZES, 30 BES) using optical coherence tomography (OCT) assessment. Each patient was randomly assigned to six-month (n=684) or 12-month DAPT (n=684). Major adverse cardiac events at 12 months occurred in eight patients (1.2%) in the six-month DAPT group and in four patients (0.6%) in the 12-month DAPT group (risk difference 0.6%; 95% confidence interval [CI]: -0.4-1.6%; p=0.24). The upper 95% CI limit was lower than the pre-specified limit of 4% non-inferiority (p for non-inferiority <0.05). The percentage of uncovered struts was 3.16±4.30% at six months in 60 stents of 60 patients.. After second-generation DES implantation, six-month DAPT was not inferior to 12-month DAPT in terms of MACE occurrence over the 12-month follow-up period. OCT examination revealed favourable stent strut coverage at six months after stent implantation. Topics: Aged; Aspirin; Cardiovascular Agents; Clopidogrel; Coronary Angiography; Coronary Artery Disease; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Long-term outcomes after percutaneous revascularization of complex coronary bifurcation lesions using a dedicated self-expanding biolimus-eluting stent system.
To evaluate long-term clinical outcomes after treatment of complex bifurcation lesions with the AXXESS dedicated self-expanding biolimus A9-eluting bifurcation stent.. Between 2004 and 2013, 123 patients with complex bifurcation lesions were treated in a single-center with the AXXESS stent in the proximal main vessel (MV) and additional drug-eluting stents in branches when required. Median follow-up was 5 years. Primary endpoint was the rate of major adverse cardiac events (MACE). Secondary endpoints included MACE components (cardiac death, non-periprocedural clinical myocardial infarction [MI], target lesion revascularization [TLR] and definite/probable stent thrombosis [ST]) as well as all-cause death, target vessel revascularization (TVR) and non-TVR.. During follow-up, 11 (8.9%) patients experienced a MACE, of whom 2 (1.6%) suffered cardiac death, 2 (1.6%) had a non-periprocedural clinical MI requiring TLR, and 7 (5.7%) underwent elective TLR. No definite/probable ST was observed. All-cause death occurred in 9 (7.3%) patients, TVR in 11 (8.9%) and non-TVR in 11 (8.9%). Patients treated for left main (LM) bifurcation lesions were more likely to experience MACE than non-LM bifurcation lesions (25% vs. 6.5%, p = 0.04).. Percutaneous revascularization of complex bifurcation lesions with the AXXESS stent is safe and provides excellent long-term results, especially in non-LM lesions. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Prosthesis Design; Retrospective Studies; Self Expandable Metallic Stents; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Two-year outcomes of high bleeding risk patients with acute coronary syndrome after Biolimus A9 polymer-free drug-coated stents: a LEADERS FREE substudy.
Topics: Acute Coronary Syndrome; Cardiovascular Agents; Double-Blind Method; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Hemorrhage; Humans; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.
This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage.. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited.. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT.. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80).. OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with favorable early strut coverage (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of The Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus-eluting Stents Versus Biolimus A9-eluting Stents [DETECT-OCT]; NCT01752894). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Feasibility Studies; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Republic of Korea; Risk Factors; Sirolimus; Stroke; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Vascular response to biolimus A-9 eluting stent in patients with shorter and prolonged dual antiplatelet therapy: optical coherence tomography sub-study of the NIPPON trial.
Dual antiplatelet therapy (DAPT) with thienopyridine and aspirin is the standard care for the prevention of stent thrombosis. However, the optimal duration and effect of the duration of DAPT on intra-stent thrombus (IS-Th) formation are unknown. The NIPPON study (Nobori Dual Antiplatelet Therapy as Appropriate Duration) was an open label, randomized multicenter, assessor-blinded, trial designed to demonstrate the non-inferiority of shorter (6-month) DAPT to prolonged (18-month) DAPT, after biolimus A9 eluting stent implantation in 3773 patients at 130 sites in Japan. Among them, 101 patients were randomly allocated for an optical coherence tomography (OCT) sub-study to assess the difference of local IS-Th formation between the two groups. In addition to standard OCT parameters, the number of IS-Th formed was counted in each target stent at 8 months. Baseline patient characteristics were not different between the 6- and 18-month groups. IS-Th was detected in 9.8% of the cases and the presence of IS-Th was not significantly different between the two groups (10.9% in 6-month vs. 9.1% in 12-month, P = 0.76). Furthermore, the number of IS-Th formed was not significantly different between the two groups. This OCT sub-study was in line with the main NIPPON study which demonstrated the non-inferiority of 6-month DAPT to 18-month DAPT. Shorter DAPT duration did not promote progressive IS-Th formation at the mid-term time point. Topics: Aged; Aspirin; Coronary Artery Disease; Coronary Vessels; Dose-Response Relationship, Drug; Drug Therapy, Combination; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Pyridines; Retrospective Studies; Single-Blind Method; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Vascular Resistance | 2018 |
5-Year clinical follow-up of the COBRA (complex coronary bifurcation lesions: Randomized comparison of a strategy using a dedicated self-expanding biolimus A9-eluting stent vs. a culotte strategy using everolimus-eluting stents) study.
We evaluated healing responses with optical coherence tomography, and long-term clinical outcomes after treatment with a dedicated stent versus a conventional culotte technique.. Dedicated bifurcation stents have been proposed as an alternative treatment for coronary bifurcation lesions. The long-term performance of dedicated stents versus conventional dual-stent techniques for the treatment of complex coronary bifurcation lesions is unknown.. Forty patients with true coronary bifurcation lesions were randomized to treatment with a dedicated Axxess bifurcation stent in the proximal main vessel and additional Biomatrix stents in branches versus culotte stenting using Xience stents.. The percentage of uncovered struts in each bifurcation segment at 9 months (primary endpoint) was similar between groups. Five-year clinical follow-up was available for all patients and included major adverse cardiac events [MACE; a composite of cardiac death, myocardial infarction (MI) and ischemia-driven target lesion revascularization (TLR)], target-vessel (TVR) and non-target-vessel revascularization (non-TVR), non-TLR and stent thrombosis. At 5 years, in the culotte group, one patient had undergone TLR and another suffered a clinical MI, resulting in 10% MACE versus none in the Axxess group. TVR (5% vs. 10%, P = 0.54) and non-TVR (5% vs. 20%, P = 0.39) rates were similar between the Axxess and culotte groups, respectively. There was no stent thrombosis.. Compared with culotte stenting with Xience, complex coronary bifurcation stenting using a dedicated strategy combining the Axxess and Biomatrix stents results in similar stent strut coverage at 9 months, and excellent clinical outcomes at 5 years. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.
Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer.. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size.. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Hong Kong; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Biolimus A9 polymer-free coated stents in high bleeding risk patients undergoing complex PCI: evidence from the LEADERS FREE randomised clinical trial.
The LEADERS FREE trial has demonstrated that a polymer-free Biolimus A9-coated stent (BA9-DCS) is superior to a bare metal stent (BMS) for high bleeding risk (HBR) patients when treated with one month of dual antiplatelet therapy (DAPT). This analysis aimed to determine the impact of PCI procedure complexity on the two-year results.. Six hundred and sixty-seven (667) patients enrolled in the LEADERS FREE (BA9-DCS 346, BMS 321) underwent a complex PCI, defined by one or more of eight characteristics: total stent length ≥60 mm, ≥3 vessels or lesions treated, ≥3 stents implanted, bifurcation lesion treated with ≥2 stents, chronically occluded, restenotic or saphenous vein graft lesion. Patients undergoing complex PCI were older, more often male, and presented with more ACS, diabetes, renal insufficiency, anaemia and multivessel disease. They derived major benefit from DCS over BMS for safety (16.2% vs. 21.7%, HR 0.70 [0.49-0.99], p<0.05) and for efficacy (10.8% vs. 18.1%, HR 0.54 [0.35-0.83], p<0.005). For the 1,746 patients with non-complex PCI, DCS demonstrated superior efficacy (5.3% vs. 9.9%, HR 0.52 [0.36-0.75], p<0.001, p for interaction NS) and similar safety to BMS (11.1% vs. 12.6%, NS, p for interaction NS).. Compared to BMS, the BA9-DCS maintained both efficacy and safety benefits when used in complex PCI procedures. Topics: Drug-Eluting Stents; Humans; Male; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Sirolimus; Treatment Outcome | 2018 |
Establishment of healing profile and neointimal transformation in the new polymer-free biolimus A9-coated coronary stent by longitudinal sequential optical coherence tomography assessments: the EGO-BIOFREEDOM study.
This study aimed to establish the early healing and neointimal transformation profile of the new polymer-free BioFreedom stent through sequential optical coherence tomography (OCT) within the first nine months following stent implantation.. We randomly assigned 104 BFS recipients to one of five groups with angiography and OCT follow-up at 1, 2, 3, 4, or 5 months, together with another follow-up for all at nine months. The primary endpoint was the degree of OCT-detected strut coverage at nine months. From 1, 2, 3, 4, and 5 months, median neointimal strut coverage increased from 85.8, 87.0, 88.6, 96.8 to 97.1%, respectively, to 99.6% (IQR 98.2-99.9) at nine months. At nine months, median percent neointimal volume was 13.0% and angiographic late lumen loss was 0.21±0.30 mm. Major adverse cardiac events (MACE) were limited to one non-cardiac death, one non-ST-elevation myocardial infarction not related to BFS, and two target lesion revascularisations without stent thrombosis (MACE rate 4.0%).. Neointimal strut coverage of the BFS was rapid and the BFS was shown to be clinically safe and effective. Topics: Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Early Follow-Up Optical Coherence Tomographic Findings of Significant Drug-Eluting Stent Malapposition.
Using optical coherence tomography, we evaluated early follow-up findings of significant stent malapposition (SSM) in patients treated with second-generation drug-eluting stent.. From the DETECT-OCT randomized trial (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of the Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus- Versus Biolimus-Eluting Stent), a total of 386 patients (390 lesions) who underwent both postintervention and 3-month follow-up optical coherence tomography examinations were included for the present analysis. SSM was defined as a stent that had a strut with a maximal wall-to-strut distance of ≥200 μm. Postintervention, SSM was detected in 175 lesions (44.9%), including 117 lesions with a maximal wall-to-strut distance of ≥200 to <400 μm and 58 lesions with a maximal wall-to-strut distance of ≥400 μm. As the implanted stent diameter-to-reference vessel diameter ratio grew, the risk of postintervention SSM dropped (odds ratio, 0.587; 95% CI, 0.367-0.941; P=0.0398). The optimal value that best separated SSM from non-SSM postintervention was a stent diameter-to-reference vessel diameter ratio of 1.0. At 3 months follow-up, the frequency of SSM decreased from 44.9% to 33.6% (131 lesions; P=0.0001), mainly driven by the decrease in lesions with a maximal wall-to-strut distance of ≥200 to <400 μm. As the maximal wall-to-strut distance on postintervention optical coherence tomography was larger, the risk of 3-month SSM increased (odds ratio, 1.607; 95% CI, 1.131-2.286; P=0.0284). The optimal value that best separated SSM from non-SSM at 3 months follow-up was a maximal wall-to-strut distance postintervention of 230 μm.. A spontaneous decrease in SSM was observed early in this qualified study with a large number of study patients treated with second-generation drug-eluting stent.. URL: https://www.clinicaltrials.gov . Unique identifier: NCT01752894. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Two-year vascular responses to drug-eluting stents with biodegradable polymer versus durable polymer: An optical coherence tomography sub-study of the NEXT.
This study aimed to compare very late vascular response after stent implantation between everolimus-eluting stent (EES) with a thin, non-adhesive, durable, biocompatible fluorinated polymer and biolimus-eluting stent (BES) with a biodegradable polymer by optical coherence tomography (OCT).. In the NOBORI-BES Versus XIENCE V/PROMUS-EES Trial (NEXT), a formal OCT substudy investigated 48 patients (27 EES-treated lesions in 23 patients and 28 BES-treated lesions in 25 patients) with 2-year (18-30 months) follow-up imaging at 18 centers. The percentage of uncovered strut by neointima was significantly lower in EES compared with BES (2.1±4.7% vs. 7.9±10.8%, p=0.013). The percentage of malapposed strut was not different between EES and BES (0.1±0.3% vs. 0.5±1.3%, p=0.138). The frequency of stent with evagination, which is identified as outward bulges in the luminal contour between struts, was significantly lower in EES compared with BES (22% vs. 86%, p<0.001). The frequency of neoatherosclerosis was not different between EES and BES (11% vs. 11%, p=1.000).. At 2 years after stent implantation, uncovered stent strut by neointima and evagination were less frequently observed in EES compared with BES. This OCT study suggests that the very late vascular response is different between EES and BES. Topics: Aged; Biocompatible Materials; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Polymers; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2017 |
Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: Two-year clinical outcomes of the EVERBIO II trial.
Data from randomized controlled trials have shown that the ABSORB BVS is non-inferior to Cobalt Chromium everolimus-eluting stents at 2years.. The EVERBIO II trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) is a single-center, assessor-blind, randomized controlled trial enrolling 240 patients with an allocation ration of 1:1:1 conducted at University and Hospital Fribourg, Switzerland. The studied devices were an everolimus-eluting persistent polymer stent (EES), a biolimus-eluting stent with bioabsorbable polymer (BES) and a fully bioresorbable vascular scaffold (BVS). Clinical end points collected at 9months, 12months, and 2years, were academic research consortium defined composites, device thrombosis and target-vessel revascularization. Clinical follow-up at 2years was available in 96% (N=77) of patients in the EES group, in 100% (N=80) in the BES and 99% (N=77) in the BVS group. The device-oriented composite end point of cardiac death, target-vessel myocardial infarction and target-lesion revascularization occurred in 13 (16%) patients treated with EES, in 7 (9%) patients treated with BES and in 16 (21%) patients treated with BVS. There was no significant difference when the metallic stents were compared to the BVS (p=0.12). There was one late scaffold thrombosis throughout the trial in the BVS group, and no definite stent thrombosis in either EES or BES treated patients.. The current analysis shows no significant differences with regard to clinical outcomes at 2years between BVS and the best-in-class metallic DES. Event rates were numerically higher in BVS-treated patients. However, when BVS were compared to BES alone, the occurrence of device related adverse events was significantly increased. Topics: Absorbable Implants; Aged; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Fibrinolytic Agents; Follow-Up Studies; Humans; Male; Middle Aged; Single-Blind Method; Sirolimus; Time Factors; Tissue Scaffolds; Treatment Outcome | 2017 |
Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable P
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention.. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce.. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization.. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17).. The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Rehospitalizations Following Primary Percutaneous Coronary Intervention in Patients With ST-Elevation Myocardial Infarction: Results From a Multi-Center Randomized Trial.
Rehospitalizations (RHs) after ST-elevation myocardial infarction carry a high economic burden and may deteriorate quality of life. Characterizing patients at higher risk may allow the design of preventive measures. We studied the frequency, reasons, and predictors for unplanned cardiac and noncardiac RHs in ST-elevation myocardial infarction patients undergoing primary percutaneous coronary intervention.. In this post-hoc analysis of the COMFORTABLE AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction; NCT00962416) trial including 1137 patients, unplanned cardiac and noncardiac RHs occurred in 133 (11.7%) and in 79 patients (6.9%), respectively, at 1 year. The most frequent reasons for unplanned cardiac RHs were recurrent chest pain without evidence of ischemia (20.4%), recurrent chest pain with ischemia and coronary intervention (16.9%), and ischemic events (16.9%). Unplanned noncardiac RHs occurred most frequently attributed to bleeding (24.5%), infections (14.3%), and cancer (9.1%). On multivariate analysis, left ventricular ejection fraction (22% increase in the rate of RHs per 10% decrease;. Among ST-elevation myocardial infarction patients undergoing primary percutaneous coronary intervention in the setting of a randomized, clinical trial, unplanned cardiac RHs occurred in 12% with recurrent chest pain being the foremost reason. Unplanned noncardiac RHs occurred in 7% with bleeding as the leading cause. Left ventricular ejection fraction and Syntax score were independent predictors of unplanned cardiac RHs and identified patient subgroups in need for improved secondary prevention.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00962416. Topics: Absorbable Implants; Age Factors; Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Drug-Eluting Stents; Europe; Female; Humans; Israel; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Patient Readmission; Percutaneous Coronary Intervention; Prosthesis Design; Risk Factors; Sirolimus; ST Elevation Myocardial Infarction; Stroke Volume; Time Factors; Treatment Outcome; Ventricular Function, Left | 2017 |
Safety and Efficacy of Polymer-Free Biolimus A9-Coated Versus Bare-Metal Stents in Orally Anticoagulated Patients: 2-Year Results of the LEADERS FREE Oral Anticoagulation Substudy.
The aim of this study was to compare the performance of drug-coated stents (DCS) versus bare-metal stents (BMS) in patients who are candidates for long-term oral anticoagulation (OAC) after percutaneous coronary interventions.. The randomized controlled LEADERS FREE (A Randomized Clinical Evaluation of the BioFreedom™ Stent) trial demonstrated the superior safety and efficacy of a polymer-free biolimus A9 DCS compared with a similar BMS used with 1 month of dual antiplatelet therapy in 2,466 patients at high bleeding risk.. The 2 stents were compared in a pre-specified analysis of the 879 LEADERS FREE patients (35.6%) scheduled to remain on OAC after percutaneous coronary intervention. The primary safety endpoint was a composite of cardiac death, myocardial infarction, and stent thrombosis. The primary efficacy endpoint was the incidence of clinically driven target lesion revascularization.. Baseline characteristics of 448 DCS and 431 BMS recipients were similar, 78.8% had histories of atrial fibrillation, and 21% presented with acute coronary syndromes. Four hundred patients in the DCS group and 376 in the BMS group were discharged on OAC after percutaneous coronary intervention. At 2 years, for the DCS and BMS recipients, respectively, the incidence of clinically driven target lesion revascularization was 7.5% versus 11.2% (hazard ratio: 0.63; 95% confidence interval: 0.40 to 1.01; p = 0.0514), the safety endpoint was reached by 14.4% and 15.0% (p = NS), and the rates of major bleeding events (Bleeding Academic Research Consortium 3 to 5) were 10.7% and 12.9% (p = NS).. The efficacy advantage of DCS over BMS up to 2 years appears confirmed in patients on long-term OAC. Despite the very short course of dual antiplatelet therapy, both the DCS and BMS groups experienced similarly high rates of major bleeding. (A Randomized Clinical Evaluation of the BioFreedom™ Stent [Leaders Free]; NCT01623180). Topics: Acute Coronary Syndrome; Administration, Oral; Aged; Aged, 80 and over; Anticoagulants; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Double-Blind Method; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Metals; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2017 |
Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents.
Our aim was to report the long-term safety and efficacy of the biodegradable polymer-coated biolimus- eluting Nobori stent compared to the durable polymer-coated sirolimus-eluting CYPHER stent.. SORT OUT V randomised 2,468 patients 1:1 to the Nobori (n=1,229) versus the CYPHER stent (n=1,239). Clinically driven event detection based on Danish registries was used. The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation). Individual components of the primary endpoint comprise the secondary endpoints. At five-year follow-up, the composite endpoint rate was found to be similar in patients treated with the two study stents (Nobori 182/1,229 [14.8%] vs. CYPHER 197/1,239 [15.8%]; odds ratio [OR] 0.93, 95% CI: 0.75-1.16; p=0.53). The rates of definite stent thrombosis were also found to be similar in patients treated with the two study stents (Nobori 23/1,229 [1.9%] vs. CYPHER 18/1,239 [1.5%]; OR 1.31, 95% CI: 0.70-2.47; p=0.40), as were the other secondary endpoints.. At five-year follow-up, the Nobori stent with a biodegradable polymer coating provided a similar safety and efficacy profile when compared to the durable polymer first-generation CYPHER stent. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Incidence; Male; Middle Aged; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Recurrence; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study.
Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Biolimus-A9-coated stent (BA9-DCS) or a bare-metal stent (BMS) in these patients.. Leaders Free included 2466 patients undergoing PCI who had at least 1 of 13 pre-defined factors for an increased bleeding risk. Of these, 659 ACS patients were included in this analysis (BA9-DCS 330, BMS 329). At 12-month follow-up, treatment with the BA9-DCS was more effective (clinically driven target-lesion revascularization 3.9 vs. 9.0%, P = 0.009) and safer (cumulative incidence of cardiac death, myocardial infarction, or definite or probable stent thrombosis 9.3 vs. 18.5%, P = 0.001), driven by significantly lower rates of cardiac mortality (3.4 vs. 6.9%, P = 0.049) and myocardial infarction (6.9 vs. 13.8%, P = 0.005).. We believe that the results of this sub-analysis from the Leaders Free trial are likely to significantly impact clinical practice for high bleeding risk patients presenting with an ACS: the use of a BMS can, in our view, no longer be recommended, and, given the paucity of available data for second-generation DES with shortened DAPT in these patients, the BA9-DCS should currently be considered as the device with the strongest evidence to support its use for this indication. Topics: Acute Coronary Syndrome; Aged; Double-Blind Method; Drug Therapy, Combination; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Hemorrhage; Humans; Immunosuppressive Agents; Male; Non-ST Elevated Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Risk Factors; Sirolimus; ST Elevation Myocardial Infarction; Treatment Outcome | 2017 |
Coronary artery bifurcation narrowing treated by Axxess stent implantation: The CARINAX registry.
To compare the safety and efficacy of the Axxess™ biolimus-eluting stent with the second-generation drug-eluting stent (DES) in the treatment of bifurcation lesions.. The Axxess™ is a dedicated bifurcation stent, designed to cover the lesion at the carina level.. Between April 2012 and August 2014, 165 patients with de novo bifurcation lesions were treated with the Axxess™ stent (Axxess group). A propensity-score matched group of 165 patients treated with DES in the same period was selected (Control group). The primary objectives were (1) the procedural complication rate, including side branch (SB) occlusion and trouble in SB access after main vessel stenting; and (2) the device, the angiographic, and the procedural success rate.. Procedural complications occurred in 1 patient (0.6%) in the Axxess group and in 20 patients (12%) in the Control group (OR = 0.03; 95% confidence interval 0.005-0.27; P < 0.001). Device success was obtained in 164 (99.5%) patients in the Axxess group and in all in the Control group (P = 1.00). Angiographic success was obtained in all patients. Inaccurate Axxess™ stent position occurred in 21 (13%) patients, and was more often associated with moderate-to-severe calcifications and distal lesion site. Procedural success was obtained in 91.5% patients in the Axxess group and in 90% patients in the Control group (P = 0.72).. The present registry suggests that the Axxess™ stent (1) may represent a valid alternative approach for the treatment of bifurcation lesions and (2) should be avoided in moderate-to-severe calcifications and/or in distal lesions. © 2016 Wiley Periodicals, Inc. Topics: Aged; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Propensity Score; Prospective Studies; Prosthesis Design; Registries; Sirolimus; Ultrasonography, Interventional | 2017 |
Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.
We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern. Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Metals; Neointima; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2017 |
2-Year Outcomes of High Bleeding Risk Patients After Polymer-Free Drug-Coated Stents.
A 1-year follow-up, polymer-free metallic stent coated with biolimus-A9 followed by 1-month dual antiplatelet therapy is safer and more effective than a bare-metal stent (BMS) for patients with high risk of bleeding.. This study analyzed 2-year outcomes to determine whether these benefits are maintained.. In a prospective, multicenter, double-blind trial, we randomized 2,466 high bleeding risk patients to receive a drug-coated stent (DCS) or a BMS followed by 1-month dual antiplatelet therapy. The primary safety endpoint was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy endpoint was clinically driven target lesion revascularization.. At 2 years, the primary safety endpoint had occurred in 147 DCS and 180 BMS patients (15.3%) (hazard ratio: 0.80; 95% confidence interval: 0.64 to 0.99; p = 0.039). Clinically driven target lesion revascularization occurred for 77 DCS and 136 BMS patients (12.0%) (hazard ratio: 0.54; 95% confidence interval: 0.41 to 0.72; p < 0.0001). Major bleeding occurred in 8.9% of DCS and 9.2% of BMS patients (p = 0.95), and a coronary thrombotic event (myocardial infarction and/or stent thrombosis) occurred in 8.2% of DCS and 10.6% of BMS patients (p = 0.045). One-year mortality was 27.1% for a major bleed and 26.3% for a thrombotic event. At 2 years, multivariate correlates of major bleeding were age >75 years, anemia, raised plasma creatinine, and planned long-term anticoagulation. Correlates of the primary safety endpoint were age, anemia, congestive heart failure, multivessel disease, number of stents implanted, and use of a BMS rather than a DCS.. Safety and efficacy benefits of DCS over BMS were maintained for 2 years in high bleeding risk patients. Rates of major bleeding and coronary thrombotic events were no different and were associated with a substantial and comparable mortality risk. (A Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug Coated Stent Versus the Gazelle Bare Metal Stent in Patients With High Risk of Bleeding [LEADERS FREE]; NCT01623180). Topics: Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Disease; Coronary Thrombosis; Death; Double-Blind Method; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prospective Studies; Risk; Sirolimus; Statistics as Topic; Stents; Survival Rate | 2017 |
Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial.
The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients.. Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking.. The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months.. From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33).. At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Denmark; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Long-term ticagrelor monotherapy versus standard dual antiplatelet therapy followed by aspirin monotherapy in patients undergoing biolimus-eluting stent implantation: rationale and design of the GLOBAL LEADERS trial.
The GLOBAL LEADERS trial is a superiority study in patients undergoing percutaneous coronary intervention, with a uniform use of Biolimus A9-eluting stents (BES) and bivalirudin. GLOBAL LEADERS was designed to assess whether a 24-month antithrombotic regimen with ticagrelor and one month of acetylsalicylic acid (ASA), compared to conventional dual antiplatelet therapy (DAPT), improves outcomes.. Patients (n >16,000) are randomised (1:1 ratio) to ticagrelor 90 mg twice daily for 24 months plus ASA ≤100 mg for one month versus DAPT with either ticagrelor (acute coronary syndrome) or clopidogrel (stable coronary artery disease) for 12 months plus ASA ≤100 mg for 24 months. The primary outcome is a composite of all-cause mortality or non-fatal, new Q-wave myocardial infarction at 24 months. The key safety endpoint is investigator-reported class 3 or 5 bleeding according to the Bleeding Academic Research Consortium (BARC) definitions. Sensitivity analysis will be carried out to explore potential differences in outcome across geographic regions and according to specific angiographic and clinical risk estimates.. The GLOBAL LEADERS trial aims to assess the role of ticagrelor as a single antiplatelet agent after a short course of DAPT for the long-term prevention of cardiac adverse events, across a wide spectrum of patients, following BES implantation. Topics: Acute Coronary Syndrome; Adenosine; Adolescent; Adult; Aged; Aged, 80 and over; Aspirin; Drug Combinations; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Purinergic P2Y Receptor Antagonists; Sirolimus; Ticagrelor; Time; Treatment Outcome; Young Adult | 2016 |
First generation versus second generation drug-eluting stents for the treatment of bifurcations: 5-year follow-up of the LEADERS all-comers randomized trial.
Historically, percutaneous coronary intervention (PCI) of bifurcation lesions was associated with worse procedural and clinical outcomes when compared with PCI of non-bifurcation lesions. Newer generation drug-eluting stents (DES) might improve long-term clinical outcomes after bifurcation PCI.. The LEADERS trial was a 10-center, assessor-blind, non-inferiority, all-comers trial, randomizing 1,707 patients to treatment with a biolimus A9(TM) -eluting stent (BES) with an abluminal biodegradable polymer or a sirolimus-eluting stent (SES) with a durable polymer (ClinicalTrials.gov Identifier: NCT00389220). Five-year clinical outcomes were compared between patients with and without bifurcation lesions and between BES and SES in the bifurcation lesion subgroup. There were 497 (29%) patients with at least 1 bifurcation lesion (BES = 258; SES = 239). At 5-year follow-up, the composite endpoint of cardiac death, myocardial infarction (MI) and clinically-indicated (CI) target vessel revascularization (TVR) was observed more frequently in the bifurcation group (26.6% vs. 22.4%, P = 0.049). Within the bifurcation lesion subgroup, no differences were observed in (cardiac) death or MI rates between BES and SES. However, CI target lesion revascularization (TLR) (10.1% vs. 15.9%, P = 0.0495), and CI TVR (12.0% vs. 19.2%, P = 0.023) rates were significantly lower in the BES group. Definite/probable stent thrombosis (ST) rate was numerically lower in the BES group (3.1% vs. 5.9%, P = 0.15). Very late (>1 year) definite/probable ST rates trended to be lower with BES (0.4% vs. 3.1%, P = 0.057).. In the treatment of bifurcation lesions, use of BES led to superior long-term efficacy compared with SES. Safety outcomes were comparable between BES and SES, with an observed trend toward a lower rate of very late definite/probable ST between 1 and 5 years with the BES. © 2015 Wiley Periodicals, Inc. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Polymer-Free Biolimus A9-Coated Stents in the Treatment of De Novo Coronary Lesions: 4- and 12-Month Angiographic Follow-Up and Final 5-Year Clinical Outcomes of the Prospective, Multicenter BioFreedom FIM Clinical Trial.
The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions.. The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland).. A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany.. Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported.. The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Germany; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Single-Blind Method; Sirolimus; Stainless Steel; Surface Properties; Time Factors; Treatment Outcome | 2016 |
Vascular response to everolimus- and biolimus-eluting coronary stents versus everolimus-eluting bioresorbable scaffolds--an optical coherence tomography substudy of the EVERBIO II trial.
Head-to-head optical coherence tomography (OCT) data comparing metallic stents with bioresorbable vascular scaffolds (BVS) are lacking. This study assessed vascular healing at 9-month follow-up after implantation of everolimus- and biolimus-eluting stents (EES; BES) and everolimus-eluting BVS.. OCT was performed in 74 patients enrolled in the EVERBIO II (NCT01711931) trial (23 with EES: 26 lesions, 7 625 struts; 23 with BES: 26 lesions, 6 140 struts; 28 with BVS: 33 lesions, 10 891 struts). OCT images were acquired using the pullback and nonocclusive flushing technique and analysed offline.. BVS demonstrated fewer uncovered struts per patient (12 ± 27 [3.8 ± 8.4%] vs 59 ± 55 [21.8 ± 13.7%] in the EES&BES group, p <0.001), and thicker neointimal hyperplasia (BVS 102 ± 44 µm vs EES&BES 66 ± 36 µm, p <0.01). There was no significant difference with regard to malapposed struts (2.1 ± 2.7% in the BVS vs 4.4 ± 8.8% in the EES&BES group, p = 0.41). In a predefined signal intensity scale, quantitative analysis of the "key component" (black) revealed lower intensity in BVS than EES&BES (14 ± 23% vs 13 ± 12%, p = 0.007). Intensity was lower in polylactide-containing stents (BVS&BES) than in EES (15 ± 19% vs 10 ± 10%, p <0.001).. BVS has fewer uncovered struts and presents with a thicker neointimal coverage compared with EES&BES. It is not known whether this improved capping correlates with superior vascular healing. Polylactide-containing stents (BVS and BES) demonstrate lower peristrut intensity compared with EES. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Single-Blind Method; Sirolimus; Tissue Scaffolds; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Complex bifurcation lesions: Randomized comparison of a fully bioresorbable modified t stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds, an OCT study: Rationale and desig
There is an ongoing controversy regarding the efficacy and safety of different percutaneous stenting techniques for coronary bifurcation lesions needing >1 stent. The promise of safe vessel restoration with bioresorbable scaffolds (BRS) may not be transferable to complex double BRS bifurcation techniques, and permanent metallic scaffolding of the bifurcation core may be needed. We identified modified-T stenting as the most promising fully bioresorbable 2-stent strategy in a preclinical setting. The objective of this study is to assess acute performance and compare long-term vessel healing with this strategy, versus an approach combining BRS with a dedicated metallic drug-eluting bifurcation stent.. In a single center, 60 consecutive patients with true and complex coronary bifurcation lesions will be randomly assigned to treatment with the dedicated self-expanding Axxess. To date the use of Absorb Topics: Absorbable Implants; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Middle Aged; Prosthesis Design; Sirolimus; Tissue Scaffolds; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial.
Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy.. The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05).. The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chromium Alloys; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Intention to Treat Analysis; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Registries; Risk Factors; Scandinavian and Nordic Countries; Single-Blind Method; Sirolimus; Stainless Steel; Time Factors; Treatment Outcome | 2016 |
Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trial.
Few data are available on long-term follow-up of drug-eluting stents in the treatment of chronic total occlusion (CTO). The LEADERS CTO sub-study compared the long-term results in CTO and non-CTO lesions of a Biolimus A9™-eluting stent (BES) with a sirolimus-eluting stent (SES).. Among 1,707 patients enrolled in the prospective, multi-center, all-comers LEADERS trial, 81 with CTOs were treated with either a BES (n = 45) or a SES (n = 36). The primary endpoint was the occurrence of major adverse cardiac events (MACE): cardiac death, myocardial infarction (MI) and clinically-indicated target vessel revascularization (TVR).. At 5 years, the rate of MACE was numerically higher in the CTO group than in the non-CTO group (29.6% vs. 23.3%; p = 0.173), with a significant increase in the incidence of target lesion revascularization (TLR) (21.0 vs. 12.6; p = 0.033), but no difference in stent thrombosis (ST). Patients with CTO receiving a BES demonstrated a lower incidence of MACE (22.2% vs. 38.9%; p = 0.147) with a significant reduction in TLR compared to patients receiving a SES (11.1% vs. 33.3%, p = 0.0214) with an incidence similar to that observed in the non-CTO group treated with BES (11.6%). Definite ST at 5 years nearly halved in the BES group (4.4% vs. 8.3%, p = 0.478) with no ST in the BES group after the first year (0% vs. 8.3%, p for interaction = 0.009).. The use of a BES showed a reduction in MACE, TVR, TLR, and ST over time in the CTO subset with similar outcome as for non-CTO lesions. Topics: Absorbable Implants; Chronic Disease; Coronary Angiography; Coronary Occlusion; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Treatment Outcome | 2016 |
Safety of 6-month duration of dual antiplatelet therapy after percutaneous coronary intervention in patients with acute coronary syndromes: Rationale and design of the Smart Angioplasty Research Team-safety of 6-month duration of Dual Antiplatelet Therapy
Dual antiplatelet therapy (DAPT) is a fundamental treatment that optimizes clinical outcomes after percutaneous coronary intervention, especially in patients with acute coronary syndrome (ACS). Although current international guidelines recommend DAPT for at least 12 months after implantation of a drug-eluting stent in patients with ACS, these recommendations are not based on randomized controlled trials dedicated to ACS population.. The SMART-DATE trial is a prospective, multicenter, randomized, and open-label study to demonstrate the noninferiority of 6-month DAPT compared with 12 months or longer DAPT in patients with ACS undergoing percutaneous coronary intervention. A total of 2,700 patients will undergo prospective, random assignment to either of the DAPT duration groups. To minimize the bias from different stent devices, the type of stents will be randomly assigned (everolimus-eluting stents, zotarolimus-eluting stents, or biolimus A9-eluting stents). The primary end point is a composite of all-cause death, myocardial infarction, and cerebrovascular events at 18 months after the index procedure. The major secondary end points are definite/probable stent thrombosis defined by the Academic Research Consortium and bleeding defined by Bleeding Academic Research Consortium type 2-5.. The SMART-DATE randomized trial is the first study exploring the safety of 6-month DAPT compared with conventional 12-month or longer DAPT dedicated to patients with ACS after second-generation drug-eluting stent implantation. Topics: Acute Coronary Syndrome; Adult; Aspirin; Clopidogrel; Drug Monitoring; Drug-Eluting Stents; Everolimus; Female; Hemorrhage; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Republic of Korea; Sirolimus; Ticlopidine; Time Factors; Treatment Outcome | 2016 |
Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome tria
Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear.. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES.. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation.. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. Topics: Absorbable Implants; Aged; Anti-Inflammatory Agents; Aspirin; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Longitudinal Studies; Male; Metals; Middle Aged; Piperazines; Platelet Aggregation Inhibitors; Polymers; Prasugrel Hydrochloride; Purinergic P2Y Receptor Antagonists; Single-Blind Method; Sirolimus; Stents; Switzerland; Thiophenes; Treatment Outcome | 2015 |
Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction.
To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up.. The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up.. The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES.. BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up.. NCT 00389220. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Recurrence; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Five-year clinical outcome of the Nobori drug-eluting coronary stent system in the treatment of patients with coronary artery disease: final results of the NOBORI 1 trial.
To assess the safety and performance of the Nobori drug-eluting stent with biodegradable polymer versus the TAXUS drug-eluting stent with permanent polymer, in the treatment of patients with de novo coronary artery lesions.. NOBORI 1 was a multicentre, randomised (2:1), prospective, controlled, clinical trial which enrolled 363 patients (238 Nobori and 125 TAXUS) with up to two de novo lesions in two epicardial vessels. The primary endpoint was in-stent late loss at nine months, while secondary endpoints included safety and efficacy up to five years. At five years, clinical data were available for 350 patients (96%). There were no differences in the composite of death and myocardial infarction (10.9% vs. 11.2%) and target lesion failure (9.2% and 10.4%), while ischaemia- and non-ischaemia-driven target lesion revascularisations were less frequent in the Nobori (6.3%) than in the TAXUS arm (16.0%). The rates of stent thrombosis (definite and probable according to the ARC definitions) were 0.0% and 3.2%, in the Nobori and TAXUS stents, respectively (p=0.014).. Five years after implantation, the Nobori DES resulted in durable treatment effects with very low TLR and no stent thrombosis. The study was not powered to assess the differences in clinical endpoints. These data are hypothesis-generating. Topics: Absorbable Implants; Aged; Coronary Artery Bypass; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Humans; Male; Middle Aged; Mortality; Myocardial Infarction; Myocardial Revascularization; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus; Treatment Outcome | 2015 |
Zotarolimus-eluting durable-polymer-coated stent versus a biolimus-eluting biodegradable-polymer-coated stent in unselected patients undergoing percutaneous coronary intervention (SORT OUT VI): a randomised non-inferiority trial.
New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent.. This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All patients who presented with stable coronary artery disease or acute coronary syndromes and at least one coronary artery lesion (more than 50% stenosis) from March, 2011, to August, 2012, were assessed for eligibility. Patients were randomly assigned in a 1:1 ratio to receive either the durable-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat. The trial was powered to assess non-inferiority of durable-polymer zotarolimus-eluting stent compared with the biodegradable-polymer biolimus-eluting stent with a predetermined non-inferiority margin of 0·025. This trial is registered with ClinicalTrials.gov, number NCT01956448.. Of 7103 screened, 1502 patients with 1883 lesions were assigned to receive the durable-polymer zotarolimus-eluting stent and 1497 patients with 1791 lesions to receive the biodegradable-polymer biolimus-eluting stent. 79 (5·3%) and 75 (5·0%) patients, respectively, met the primary endpoint (absolute risk difference 0·0025, upper limit of one-sided 95% CI 0·016%; p=0·004). The individual components of the primary endpoint did not differ significantly between stent types at 12 months.. The durable-polymer-coated zotarolimus-eluting stent was non-inferior to the biodegradable-polymer-coated biolimus-eluting stent in unselected patients.. Medtronic Cardiovascular and Biosensors Interventional Technologies. Topics: Absorbable Implants; Aged; Coated Materials, Biocompatible; Denmark; Drug-Eluting Stents; Equipment Design; Female; Humans; Immunosuppressive Agents; Intention to Treat Analysis; Male; Middle Aged; Myocardial Ischemia; Percutaneous Coronary Intervention; Polymers; Sirolimus; Treatment Outcome | 2015 |
Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds.
The first CE-approved bioresorbable vascular scaffold (BVS) is effective at treating simple lesions and stable coronary artery disease, but it has yet to be assessed versus the best-in-class drug-eluting stents (DES).. This study sought to compare the performance of a BVS with that of everolimus-eluting stents (EES) and biolimus-eluting stents (BES) in all-comer patients.. The EVERBIO II (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents II) trial was a single-center, assessor-blinded study of 240 patients randomly assigned in a 1:1:1 ratio to EES, BES, or BVS. The only exclusion criterion was a reference vessel diameter >4.0 mm, which precluded treatment with BVS. The primary endpoint was angiographic late lumen loss (LLL) at 9 months. Secondary endpoints included patient-oriented major acute coronary events (MACE) (death, myocardial infarction [MI], and any revascularization), device-oriented MACE (cardiac death, MI, and target lesion revascularization), and stent thrombosis at the 9-month clinical follow-up.. Follow-up angiography was performed in 216 patients (90.7%) at 9 months. In-stent LLL was similar between patients treated with BVS (0.28 ± 0.39 mm) and those treated with EES/BES (0.25 ± 0.36 mm; p = 0.30). Clinical outcomes were similar at 9 months: the patient-oriented MACE rate was 27% in BVS and 26% in the EES/BES group (p = 0.83) and the device-oriented MACE rate was 12% in BVS and 9% in the EES/BES group (p = 0.6).. New-generation metallic DES (EES/BES) were not superior to BVS in terms of angiographic LLL and clinical outcomes. (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents [EVERBIO II]; NCT01711931). Topics: Absorbable Implants; Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Materials Testing; Middle Aged; Percutaneous Coronary Intervention; Postoperative Complications; Sirolimus; Tissue Scaffolds; Treatment Outcome | 2015 |
Clinical Impact of Intravascular Ultrasound-Guided Chronic Total Occlusion Intervention With Zotarolimus-Eluting Versus Biolimus-Eluting Stent Implantation: Randomized Study.
There have been no randomized studies comparing intravascular ultrasound (IVUS)-guided versus conventional angiography-guided chronic total occlusion (CTO) intervention using new-generation drug-eluting stent Therefore, we conducted a prospective, randomized, multicenter trial designed to test the hypothesis that IVUS-guided CTO intervention is superior to angiography-guided intervention.. After successful guidewire crossing, 402 patients with CTOs were randomized to the IVUS-guided group (n=201) or the angiography-guided group (n=201) and secondarily randomized to Resolute zotarolimus-eluting stents or Nobori biolimus-eluting stents. The primary and secondary end points were cardiac death and a major adverse cardiac event defined as the composite of cardiac death, myocardial infarction, or target-vessel revascularization, respectively. After 12-month follow-up, the rate of cardiac death was not significantly different between the IVUS-guided group (0%) and the angiography-guided group (1.0%; P by log-rank test=0.16). However, major adverse cardiac event rates were significantly lower in the IVUS-guided group than that in the angiography-guided group (2.6% versus 7.1%; P=0.035; hazard ratio, 0.35; 95% confidence interval, 0.13-0.97). Occurrence of the composite of cardiac death or myocardial infarction was significantly lower in the IVUS-guided group (0%) than in the angiography-guided group (2.0%; P=0.045). The rates of target-vessel revascularization were not significantly different between the 2 groups. In the comparison between Resolute zotarolimus-eluting stent and Nobori biolimus-eluting stent, major adverse cardiac event rates were not significantly different (4.0% versus 5.7%; P=0.45).. Although IVUS-guided CTO intervention did not significantly reduce cardiac mortality, this randomized study demonstrated that IVUS-guided CTO intervention might improve 12-month major adverse cardiac event rate after new-generation drug-eluting stent implantation when compared with conventional angiography-guided CTO intervention.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01563952. Topics: Aged; Anti-Bacterial Agents; Coronary Angiography; Coronary Occlusion; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Random Allocation; Sirolimus; Ultrasonography, Interventional | 2015 |
Optical Coherence Tomography Guided Percutaneous Coronary Intervention With Nobori Stent Implantation in Patients With Non-ST-Segment-Elevation Myocardial Infarction (OCTACS) Trial: Difference in Strut Coverage and Dynamic Malapposition Patterns at 6 Mont
Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut coverage at 6 months in comparison with angiographic guidance only.. One hundred patients were randomized 1:1 to either OCT-guided or angio-guided Nobori biolimus-eluting stent implantation. Postprocedure OCT was performed in all patients. In the OCT-guided group, prespecified criteria indicating additional intervention were related to (1) stent underexpansion, (2) strut malapposition, (3) edge dissection(s), and (4) residual stenosis at the distal or proximal reference segment(s). A final OCT was performed in case of reintervention. Six-month OCT follow-up was available in 85 patients. Twenty-three (46%) OCT-guided patients had additional postdilation or stenting. The percentage of acutely malapposed struts was substantially lower in the OCT-guided group (3.4% [interquartile range, 0.3-7.6] versus 7.8% [interquartile range, 2.3-19.4]; P<0.01). At 6-month follow-up, the OCT-guided group had a significantly lower proportion of uncovered struts; 4.3% [interquartile range, 1.2-9.8] versus 9.0% [interquartile range, 5.5-14.5], P<0.01. Furthermore, OCT-guided patients had significantly more completely covered stents: 17.5% versus 2.2%, P=0.02. The percentages of malapposed struts and struts being both uncovered and malapposed at follow-up were comparable between groups.. OCT-guided optimization of Nobori biolimus-eluting stent implantation improves strut coverage at 6-month follow-up in comparison with angiographic guidance alone.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02272283. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Angiography; Drug-Eluting Stents; Electrocardiography; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Random Allocation; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Randomized comparison of a sirolimus-eluting Orsiro stent with a biolimus-eluting Nobori stent in patients treated with percutaneous coronary intervention: Rationale and study design of the Scandinavian Organization for Randomized Trials with Clinical Out
Third-generation coronary drug-eluting stents (DES) with biodegradable polymers have been designed to improve safety and efficacy. We designed a large scale registry-based randomized clinical trial to compare 2 third-generation DES: a thin strut, cobalt-chromium DES with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the stainless steel biodegradable polymer biolimus-eluting Nobori stents (N-BES, Nobori; Terumo, Tokyo, Japan) in an all-comer patient population.. The multicenter SORT OUT VII trial (NCT01879358) randomly assigned 2,530 patients to treatment with biodegradable polymer O-SES or biodegradable polymer N-BES at 3 sites in Western Denmark. Patients were eligible, if they were ≥18 years old; had chronic stable coronary artery disease or acute coronary syndromes; and ≥1 coronary lesion with >50% diameter stenosis, requiring treatment with a DES. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically, driven event detection based on Danish registries will be used. An event rate of 6.5% is assumed in each stent group. With a sample size of 1,157 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the O-SES compared with the N-BES with a predetermined noninferiority margin of 3.0%.. The SORT OUT VII trial will determine whether the biodegradable polymers O-SES is noninferior to the N-BES with respect to driven event. Topics: Coronary Artery Disease; Denmark; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Prosthesis Design; Retrospective Studies; Single-Blind Method; Sirolimus; Societies, Medical; Treatment Outcome | 2015 |
Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.
To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating.. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year.. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups.. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. Topics: Absorbable Implants; Aged; Brazil; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Final 3-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Either Biodegradable Polymer or Durable Polymer: NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial.
There is a paucity of data reporting the clinical outcomes of biodegradable polymer biolimus-eluting stent (BP-BES) compared with durable polymer everolimus-eluting stent (DP-EES) beyond 1 year after stent implantation when the polymer is fully degraded.. The NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial (NEXT) is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BP-BES with DP-EES in patients scheduled for percutaneous coronary intervention using drug-eluting stent (DES) without any exclusion criteria among 98 participating centers in Japan. The trial was designed to evaluate noninferiority of BP-BES relative to DP-EES in terms of any target-lesion revascularization at 1 year and death or myocardial infarction at 3 years. Between May and October 2011, 3235 patients were randomly assigned to receive either BP-BES (1617 patients) or DP-EES (1618 patients). Complete 3-year follow-up was achieved in 97.6% of patients. At 3 years, the primary safety end point of death or myocardial infarction occurred in 159 patients (9.9%) in the BP-BES group and in 166 patients (10.3%) in the DP-EES group, demonstrating noninferiority of BP-BES relative to DP-EES (P noninferiority<0.0001 and P superiority=0.7). Cumulative incidence of target-lesion revascularization was not significantly different between the 2 groups (7.4% versus 7.1%; P=0.8). By a landmark analysis at 1 year, the cumulative incidences of death or myocardial infarction and target-lesion revascularization were also not significantly different between the 2 groups (4.6% versus 5.2%; P=0.46 and 3.3% versus 2.7%; P=0.39, respectively).. Safety and efficacy outcomes of BP-BES were non inferior to those of DP-EES 3 years after stent implantation.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01303640. Topics: Absorbable Implants; Aged; Blood Vessel Prosthesis Implantation; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Japan; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Postoperative Complications; Prospective Studies; Sirolimus; Survival Analysis; Treatment Outcome | 2015 |
Polymer-free Drug-Coated Coronary Stents in Patients at High Bleeding Risk.
Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month.. In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual antiplatelet therapy. The primary safety end point, tested for both noninferiority and superiority, was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy end point was clinically driven target-lesion revascularization.. We enrolled 2466 patients. At 390 days, the primary safety end point had occurred in 112 patients (9.4%) in the drug-coated-stent group and in 154 patients (12.9%) in the bare-metal-stent group (risk difference, -3.6 percentage points; 95% confidence interval [CI], -6.1 to -1.0; hazard ratio, 0.71; 95% CI, 0.56 to 0.91; P<0.001 for noninferiority and P=0.005 for superiority). During the same time period, clinically driven target-lesion revascularization was needed in 59 patients (5.1%) in the drug-coated-stent group and in 113 patients (9.8%) in the bare-metal-stent group (risk difference, -4.8 percentage points; 95% CI, -6.9 to -2.6; hazard ratio, 0.50; 95% CI, 0.37 to 0.69; P<0.001).. Among patients at high risk for bleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet therapy. (Funded by Biosensors Europe; LEADERS FREE ClinicalTrials.gov number, NCT01623180.). Topics: Aged; Combined Modality Therapy; Coronary Artery Disease; Double-Blind Method; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Kaplan-Meier Estimate; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prosthesis Design; Sirolimus; Stents | 2015 |
Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial.
Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion.. The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter>4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography.. EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients.. The trial listed in clinicaltrials.gov as NCT01711931. Topics: Absorbable Implants; Cardiovascular Agents; Clinical Protocols; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Prosthesis Design; Research Design; Sirolimus; Switzerland; Time Factors; Tissue Scaffolds; Treatment Outcome | 2014 |
Multicenter randomized trial of 3-month cilostazol use in addition to dual antiplatelet therapy after biolimus-eluting stent implantation for long or multivessel coronary artery disease.
There are conflicting data on the use of cilostazol as triple antiplatelet therapy (TAPT) for improving clinical outcomes after drug-eluting stent implantation. We aimed to evaluate whether 3-month use of cilostazol in addition to dual antiplatelet therapy (DAPT) improved clinical outcomes in patients with long or multivessel coronary artery disease (CAD) after biolimus-eluting stent (BES) implantation.. Patients (n = 630) who had been successfully treated with BES implantation for lesions with ≥28 mm in stent length or ≥2 stents for different coronary arteries were enrolled in this prospective randomized multicenter trial. All patients were randomly assigned to receive either DAPT (aspirin and clopidogrel for 12 months, n = 314) or TAPT (DAPT plus 3-month cilostazol use, n = 316). The primary end point was a device-oriented composite consisting of cardiac death, myocardial infarction (not clearly attributable to a nontarget vessel), and ischemia-driven target lesion revascularization at 1-year follow-up.. A total of 314 patients in DAPT and 308 patients in TAPT were analyzed. Multivessel CAD was present in 65.7% of patients. Stents ≥28 mm in length were implanted in 58.1% of lesions. There were no significant differences in baseline and angiographic characteristics between the 2 groups. The primary end point was similar between the 2 groups (2.3% in DAPT vs 1.9% in TAPT, log-rank P = .799).. In patients treated with BES implantation for long or multivessel CAD, 3 months of cilostazol use in addition to DAPT did not improve clinical outcome at 1-year follow-up. Topics: Aged; Cilostazol; Clopidogrel; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Dose-Response Relationship, Drug; Drug Therapy, Combination; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Platelet Aggregation Inhibitors; Prospective Studies; Sirolimus; Tetrazoles; Ticlopidine; Time Factors; Treatment Outcome | 2014 |
Randomized comparison of biolimus-eluting stents with biodegradable polymer versus everolimus-eluting stents with permanent polymer coatings assessed by optical coherence tomography.
We sought to compare the healing patterns of biolimus-eluting stents with biodegradable polymer (BP-BES, Nobori) versus everolimus-eluting stents with permanent polymer (PP-EES, Xience) using intravascular optical coherence tomography (OCT). A total of 34 patients undergoing treatment of de novo coronary lesions were randomly assigned to receive BP-BES (n = 15) or PP-EES (n = 19). Stent tissue coverage and apposition as well as the incidence of peri-strut low intensity area (PLIA) were assessed by OCT at 6-8 months. Generalized linear mixed models were used to account for clustered data. OCT imaging was available for 17 lesions with 2,805 struts in the BP-BES group and 22 lesions with 3,890 struts in the PP-EES group. BP-BES as compared to PP-EES showed similar rates of uncovered struts (479 vs. 588, odds ratio (OR) 1.54 (95 % CI 0.63-3.79), P = 0.34) and malapposed struts (46 vs. 32 struts, OR 1.64 [95 % CI 0.21-12.5], P = 0.64). Three lesions with BP-BES (17.6 %) versus 5 lesions with PP-EES (22.7 %) had >30 % uncovered struts (P = 0.78). The proportion of patients with PLIA was similar in both groups (BP-BES 41.2 % vs. PP-EES 36.4 %, OR 1.11 [95 % CI 0.43-2.87], P = 0.83). New generation BP-BES as compared to PP-EES showed similar stent coverage and apposition as assessed by OCT at 6-8 months. In addition, PLIA-possible markers of delayed arterial healing-were observed with similar frequency in both groups. Topics: Aged; Coated Materials, Biocompatible; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Image Processing, Computer-Assisted; Immunosuppressive Agents; Male; Materials Testing; Odds Ratio; Polymers; Prospective Studies; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2014 |
Baseline and 9 months IVUS analysis of the bifurcation-dedicated biolimus A9-eluting Axxess stent system: the DIVERGE IVUS substudy.
Percutaneous treatment of complex coronary bifurcation lesions remains challenging, even in the drug-eluting stent era. We sought to evaluate the baseline and 9 months intravascular ultrasound (IVUS) analysis of the Axxess™ stent, a self-expanding, Biolimus A9™-eluting, and dedicated bifurcation stent.. We enrolled the first 76 patients from selected sites of the 302 patients large DIVERGE trial (a prospective, single-arm, multicenter trial evaluating the safety and efficacy of the Axxess stent). Both baseline and 9 months IVUS images were collected for serial two-dimensional (2D) and 3D analysis. A minimal amount and a low percentage of neointimal volume index were seen in the Axxess stent at 9 months (0.4 ± 0.6 mm(3) /mm and 4.3 ± 5.2%, respectively). Vessel, lumen, and stent volume indices increased significantly (respectively, 17.0 ± 3.6 to 18.9 ± 3.7 mm(3) /mm, P < 0.0001; 7.3 ± 2.0 to 9.2 ± 2.5 mm(3) /mm, P < 0.0001; and 7.4 ± 2.0 to 9.6 ± 2.6 mm(3) /mm, P < 0.0001). This resulted in minimum lumen area (MLA) enlargement (6.1 ± 1.9 to 7.2 ± 2.3 mm(2) , P < 0.0001), whereas peristent plaque area decreased (8.7 ± 2.5 to 8.5 ± 2.1 mm(3) /mm, P = 0.016). At 9 months, 16 (26%) incomplete stent apposition (ISA) persisted from baseline, while six resolved (9.7%). Only one (2%) ISA was late acquired. In the additional distal sirolimus-eluting stents, MLA decreased from 4.3 ± 1.1 to 4.1 ± 1.2 mm(2) (P = 0.04) at 9 months for the main branch, and from 3.4 ± 1.2 to 3.2 ± 1.2 mm(2) (P = 0.09) for the side branch.. The dedicated bifurcation Axxess stent system demonstrates significant stent volume increase with minimal neointimal formation and a low incidence of late-acquired ISA at 9 months. Topics: Adolescent; Adult; Aged; Aged, 80 and over; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Treatment Outcome; Ultrasonography, Interventional; Young Adult | 2014 |
Randomised comparison of strut coverage between Nobori biolimus-eluting and sirolimus-eluting stents: an optical coherence tomography analysis.
The aims of this study were to compare strut tissue coverage at six-month follow-up after Nobori biolimus-eluting stent (N-BES) versus sirolimus-eluting stent (SES) implantation.. A total of 120 patients with a single stenotic lesion requiring revascularisation were randomly assigned to either N-BES (n=60) or SES (n=60). Baseline optical coherence tomography (OCT) was performed post stent implantation, and follow-up OCT was scheduled at six months. Post-intervention and follow-up OCT analyses were available in 51 (85.0%) and 52 (86.7%) patients, respectively. The primary endpoint was the percentage of uncovered struts at follow-up OCT in all cross-sections with analysis of 0.2 mm longitudinal intervals. In addition, an OCT contour plot analysis was constructed to investigate the distribution patterns of uncovered struts. The percentage of uncovered struts of N-BES was significantly lower versus SES (15.9±12.2% versus 25.1±18.3%, respectively, p=0.003). N-BES showed a greater NIH thickness than SES (median [interquartile range] 52.4 μm [41.9-74.9] versus 42.1 μm [30.6-56.0], p=0.005). Contour plot analyses showed a lower incidence of a diffuse distribution pattern of uncovered struts (46.8% versus 75.0%, respectively, p=0.022).. This randomised OCT study showed that N-BES had a significantly lower percentage of uncovered struts, and less common diffuse distribution pattern of uncovered struts versus SES. Topics: Aged; Cardiovascular Agents; Coronary Stenosis; Coronary Vessels; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2014 |
Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial.
Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo percutaneous coronary intervention. The current study, therefore, evaluated 2 innovative drug-eluting stents for the management of long-lesion coronary artery disease.. This randomized, multicenter, prospective trial, called the Long Drug-Eluting Stent (LONG-DES) V trial, compared the biodegradable polymer-based biolimus A9-eluting stent (BES) and the durable polymer-based platinum chromium everolimus-eluting stent (PtCr-EES) in 500 patients with long (≥ 25 mm) coronary lesions. The primary end point of the trial was in-segment late luminal loss at the 9-month angiographic follow-up. The BES and PtCr-EES groups had similar baseline characteristics, with a slightly shorter lesion length in the BES group versus the PtCr-EES group (29.24 ± 12.17 versus 32.27 ± 13.84 mm; P = 0.016). In-segment late luminal loss was comparable between the 2 groups at the 9-month angiographic follow-up (BES, 0.14 ± 0.38 versus PtCr-EES, 0.11 ± 0.37 mm; difference, 0.031; 95% confidence interval, -0.053 to 0.091; P = 0.03 for a noninferiority margin of 0.11, P = 0.45 for superiority), as was in-stent late luminal loss (0.20 ± 0.41 versus 0.24 ± 0.38 mm; P = 0.29). The incidence of in-segment (6.1% versus 4.9%; P = 0.63) and in-stent (3.7% versus 4.9%; P = 0.59) binary restenosis was also similar between the groups. There was no significant between-group difference in the rate of composite outcome of death, myocardial infarction, and target vessel revascularization (41, 16.7% in BES versus 42, 16.5% in PtCr-EES; P=0.94).. BES and PtCr-EES implantation showed analogous angiographic and clinical outcomes for patients with de novo long coronary lesions.. http://www.clinicaltrials.gov. Unique identifier: NCT01186120. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Single-Blind Method; Sirolimus; Survival Rate; Thrombosis; Treatment Outcome | 2014 |
Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction: two-year clinical results of the COMFORTABLE AMI trial.
This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) were sustained during long-term follow-up.. A total of 1161 patients were randomly assigned to biolimus-eluting stent (BES) and BMS at 11 centers, and follow-up rates at 2 years were 96.3%. A subgroup of 103 patients underwent angiography at 13 months. At 2 years, differences in the primary end point of cardiac death, target-vessel myocardial infarction, and target lesion revascularization continued to diverge in favor of BES-treated patients (5.8%) compared with BMS-treated patients (11.9%; hazard ratio = 0.48; 95% confidence interval, 0.31-0.72; P < 0.001) with a significant risk reduction during the second year of follow-up (hazard ratio 1-2 years = 0.45; 95% confidence interval, 0.20-1.00; P = 0.049). Differences in the primary end point were driven by a reduction in target lesion revascularization (3.1% versus 8.2%; P < 0.001) and target-vessel reinfarction (1.3% versus 3.4%; P = 0.023). The composite of death, any reinfarction and revascularization (14.5% versus 19.3%; P = 0.03), and cardiac death or target-vessel myocardial infarction (4.2% versus 7.2%; P = 0.036) were less frequent among BES-treated patients compared with BMS-treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0 ± 7.2 in BES- and 39.6 ± 25.2 in BMS-treated lesions (P < 0.001).. Among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued to improve cardiovascular events compared with BMS beyond 1 year.. http://www.clinicaltrials.gov. Unique identifier: NTC00962416. Topics: Aged; Coronary Angiography; Coronary Vessels; Death, Sudden, Cardiac; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Incidence; Longitudinal Studies; Male; Metals; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Recurrence; Sirolimus; Stents; Treatment Outcome | 2014 |
Favorable vessel healing after nobori biolimus A9-eluting stent implantation-6- and 12-month follow-up by optical coherence tomography.
Nobori is a novel biolimus A9-eluting stent (BES) coated with a biodegradable polymer only on the abluminal side, which degrades over 6-9 months post-stent deployment. The course of vessel reaction after deployment at these time points remains unclear.. We serially evaluated 28 BES implanted in de novo coronary lesions of 23 patients using optical coherence tomography (OCT) at 6 and 12 months post-stenting. Standard OCT variables, the percentage of stent with peri-strut low-intensity area (PLIA, a region around stent struts homogenously showing lesser intensity than the surrounding tissue, suggesting fibrin deposition or impaired neointima maturation) and that with in-stent thrombi were evaluated. There was a significant, but small increase in neointimal thickness (72 ± 23 to 82 ± 25 µm, P=0.006) from the 6- to the 12-month follow-up, without a significant decrease in minimum lumen area (P=0.30). The incidences of uncovered and malapposed struts were low at 6 months and reduced further at 12 months (3.96 ± 3.97% to 1.51 ± 1.63%, P=0.001, and 0.50 ± 1.84% to 0.06 ± 0.24%, P=0.20, respectively). The frequency of stent with PLIA decreased during the follow-up (57% to 32%, P=0.05) and that with in-stent thrombi also numerically decreased (7% to 0%, P=0.24).. Neointimal hyperplasia was persistently suppressed following BES implantation up to 12 months. Simultaneously, favorable vessel healing was achieved at 6 months without a delaying adverse reaction for up to 12 months. Topics: Aged; Biodegradable Plastics; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Hyperplasia; Male; Middle Aged; Neointima; Regeneration; Sirolimus; Tomography, Optical Coherence | 2014 |
Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent: a randomized, controlled, noninferiority trial.
NEXT (NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial) was designed for evaluating the noninferiority of a biolimus-eluting stent (BES) relative to an everolimus-eluting stent (EES) in terms of target lesion revascularization (TLR) at 1 year.. Efficacy and safety data comparing biodegradable polymer BES with durable polymer cobalt-chromium EES are currently limited.. The NEXT trial is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BES with EES. Between May and October 2011, 3,235 patients were randomly assigned to receive either BES (n = 1,617) or EES (n = 1,618).. At 1 year, the primary efficacy endpoint of TLR occurred in 67 patients (4.2%) in the BES group, and in 66 patients (4.2%) in the EES group, demonstrating noninferiority of BES relative to EES (p for noninferiority <0.0001, and p for superiority = 0.93). Cumulative incidence of definite stent thrombosis was low and similar between the 2 groups (0.25% vs. 0.06%, p = 0.18). An angiographic substudy enrolling 528 patients (BES: n = 263, and EES: n = 265) demonstrated noninferiority of BES relative to EES regarding the primary angiographic endpoint of in-segment late loss (0.03 ± 0.39 mm vs. 0.06 ± 0.45 mm, p for noninferiority <0.0001, and p for superiority = 0.52) at 266 ± 43 days after stent implantation.. One-year clinical and angiographic outcome after BES implantation was noninferior to and not different from that after EES implantation in a mostly stable coronary artery disease population. One-year clinical outcome after both BES and EES use was excellent, with a low rate of TLR and extremely low rate of stent thrombosis. Topics: Absorbable Implants; Aged; Aged, 80 and over; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Male; Middle Aged; Polymers; Prospective Studies; Radiography; Single-Blind Method; Sirolimus; Treatment Outcome | 2013 |
Study design and rationale of "a multicenter, open-labeled, randomized controlled trial comparing three 2nd-generation drug-eluting stents in real-world practice" (CHOICE trial).
The second-generation drug-eluting stents (DES) have shown superiority in many studies relating to safety and efficacy when compared with the first-generation DES. However, it is unclear whether there are differences in efficacy and safety among the second-generation DES after long-term follow-up.. This multicenter, prospective, randomized, open-labeled trial will directly compare the efficacy and safety among the patients treated with either everolimus-eluting stent (EES), zotarolimus-eluting stent with biolinx polymer (ZES-R), or biolimus-eluting stent (BES) with minimal exclusion criteria. The primary end point is a patient-oriented composite consisted of cardiac death, myocardial infarction not clearly attributable to a nontarget vessel and clinically indicated target lesion revascularization at 24-month clinical follow-up post-index procedure. With the hypothesis that "BES is non-inferior to EES" or "BES is non-inferior to ZES-R" in primary end point, approximately 2,600 patients will be assigned to one of the types of stents using a web-based randomization system.. The CHOICE trial will directly compare the efficacy and safety of EES, ZES-R, and BES in everyday clinical practice for long-term follow-up. Topics: Adult; Algorithms; Coronary Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Myocardial Infarction; Prosthesis Design; Sirolimus | 2013 |
Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-month and 12-month serial follow-up.
No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES).. A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n=30) and SES (n=30) implantation groups. Serial OCT evaluation at post-procedure, 3- and 12-month follow-up was performed in 46 patients [BES (n=22) and SES (n=24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Δ) of uncovered struts in the 3- and 12-month follow-up samples.. The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0-23.4) versus 8.6% (0.7-21.5) (p=0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8-5.6) versus 6.2% (1.7-14.7), (p=0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage Δ of uncovered struts from 3-12 months than that of SES [-17.2±14.5% versus -7.7±16.3%, respectively (p=0.043)].. Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months. Topics: Antineoplastic Agents, Phytogenic; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Paclitaxel; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Tunica Intima | 2013 |
Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus
This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial.. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES.. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat.. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005).. The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Intention to Treat Analysis; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Three-year clinical results of the Axxess Biolimus A9 eluting bifurcation stent system: the DIVERGE study.
To report the three-year clinical outcome of the Axxess™ stent, a nitinol self-expanding Biolimus A9™ eluting stent for treatment of de novo coronary bifurcation lesions. The Axxess stent is a new-generation drug-eluting stent that might offer advantages in terms of improved clinical outcomes and safety profile in bifurcation lesion stenting.. The DIVERGE study was a multicentre, prospective, single-arm trial. The primary endpoint was the cumulative rate of major adverse cardiac events (MACE), a composite of all-cause death, myocardial infarction (MI), and ischaemia-driven target lesion revascularisation (TLR) at one, two and three years. Secondary safety endpoints were cumulative stent thrombosis (ST). A total of 302 patients were included across 14 sites: 77.4% had a true bifurcation lesion, with the left anterior descending/diagonal as target vessel in 80.8%. The Axxess stent was placed in 299 patients (99.0%) and scored as optimal in 93.0%. Two hundred and ninety-eight patients (98.7%) returned for the three-year follow-up. The MACE rate was 9.3% at one year, 14.0% at two years and 16.1% at three years. Individual components at three years were 10.1% for ischaemia-driven TLR, 3.0% for death (2.0% cardiac death), and 7.4% for MI. In the secondary safety endpoint at three years, a total of seven patients (2.3%) had ST with six (2.0%) definite and two (0.7%) probable ST events.. The present large study of the Axxess stent reports a good cumulative MACE rate during three years of long-term follow-up. The Axxess stent offers a promising treatment strategy for bifurcation lesions. Topics: Aged; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Prospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.
Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting.. This randomised, multicentre, all-comer, non-inferiority trial was undertaken at three sites across western Denmark. Eligible patients were aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes, and at least one coronary artery lesion (>50% diameter stenosis). We randomly assigned patients (1:1) using an independently managed computer-generated allocation sequence to receive either a biolimus-eluting biodegradable polymer stent (Nobori, Terumo, Tokyo, Japan) or a sirolimus-eluting permanent polymer stent (Cypher Select Plus, Cordis, Johnson & Johnson, Warren, NJ, USA). The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation) at 9 months, analysed by intention to treat (non-inferiority margin of 0·02). This trial is registered with ClinicalTrials.gov, number NCT01254981.. From July, 2009, to January, 2011, we assigned 1229 patients (1532 lesions) to receive the biolimus-eluting stent and 1239 (1555 lesions) to receive the sirolimus-eluting stent. One patient was lost to follow-up because of emigration. Intention-to-treat analysis showed that 50 (4·1%) patients who were assigned the biolimus-eluting stent and 39 (3·1%) who were assigned the sirolimus-eluting stent met the primary endpoint (risk difference 0·9% [upper limit of one-sided 95% CI 2·1%]; p(non-inferiority)=0·06). Significantly more patients in the biolimus-eluting stent group had definite stent thrombosis at 12 months than did those in the sirolimus-eluting stent group (9 [0·7%] vs 2 [0·2%], risk difference 0·6% [95% CI 0·0-1·1]; p=0·034). Per-protocol analysis showed that 45 (3·8%) of 1193 patients who received a biolimus-eluting stent and 39 (3·2%) of 1208 who received a sirolimus-eluting stent met the primary endpoint (risk difference 0·5% [upper limit of one-sided 95% CI 1·8%]; p(non-inferiority)=0·03).. At 1 year follow-up, the biodegradable polymer biolimus-eluting Nobori stent did not improve clinical results compared with a first-generation sirolimus-eluting stent. We will need to obtain long-term data before we can make recommendations for the role of this biolimus-eluting stent in routine clinical practice.. Terumo and Cordis (Johnson & Johnson). Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Aspirin; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Male; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Retreatment; Sirolimus | 2013 |
Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent (COMPARE II): a randomised, controlled, non-inferiority trial.
Drug-eluting stents with durable biocompatible or biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation drug-eluting stents. We aimed to compare the safety and efficacy of a biodegradable polymer-coated biolimus-eluting stent with a thin-strut everolimus-eluting stent coated with a durable biocompatible polymer.. This open-label, prospective, randomised, controlled, non-inferiority trial was undertaken at 12 sites across Europe. We used limited exclusion criteria (age >18 years, life expectancy >5 years, reference vessel diameter 2·0-4·0 mm) to enrol patients eligible for percutaneous coronary intervention. Patients were randomly allocated (2:1) by computer-generated random numbers to receive either a biodegradable polymer biolimus-eluting stent (Nobori, Terumo, Tokyo, Japan) or a durable fluoropolymer-based everolimus-eluting stent (Xience V or Prime, Abbott Vascular, Santa Clara, CA, USA, or Promus, Boston Scientific, Natick, MA, USA). The primary endpoint was a composite of safety (cardiac death and non-fatal myocardial infarction) and efficacy (clinically indicated target vessel revascularisation) at 12 months, analysed by intention to treat. Patients received dual antiplatelet therapy for 12 months after discharge. The trial is registered with ClinicalTrials.gov, number NCT01233453.. From Jan 12, 2009, to Feb 7, 2011, we enrolled 2707 patients (4025 lesions), 1795 of whom were assigned to receive the biolimus-eluting stent (2638 lesions) and 912 to an everolimus-eluting stent (1387 lesions). 2688 (99·3%) patients completed 12 months' follow-up. Significantly more patients in the biolimus-eluting stent group received a non-assigned stent than did those in the everolimus-eluting stent group (105 [5·9%] vs 19 [2·1%]; p<0·0001). The primary endpoint occurred in 93 (5·2%) patients in the biolimus-eluting stent group and 44 (4·8%) patients in the everolimus-eluting stent group at 12 months (relative risk 1·07 [95% CI 0·75-1·52]; p(non-inferiority)<0·0001). Analysis per protocol did not change the outcome of this trial (p(non-inferiority)<0·0001).. Biodegradable polymer biolimus-eluting stents are as safe and efficacious as the current standard of a thin-strut everolimus-eluting stent with a durable biocompatible polymer. We need to follow-up patients for longer to show whether the biolimus-eluting stent reduces the risk of stent thrombosis after 1 year when compared with the everolimus-eluting stent.. Terumo Europe (Leuven, Belgium) and the Research Foundation of the Cardiology Department, Maasstad Hospital (Rotterdam, Netherlands). Topics: Absorbable Implants; Aspirin; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Materials Testing; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Prospective Studies; Sirolimus | 2013 |
Favorable pharmacokinetics of biolimus A9 after deployment of Nobori stent for coronary artery disease: insights from Nobori PK study in Japanese subjects.
The Nobori stent is a new drug-eluting stent (DES) with biodegradable polymer coating limited to the abluminal side of stents. Biolimus A9 is a novel sirolimus derivative specifically developed for DES, and polymer load 15.6 μg of biolimus A9 per 1 mm of stent. A non-randomized multicenter trial was conducted in Japan. Twenty-two de novo lesions were treated by Nobori stents and biolimus A9 concentration in whole blood was serially measured at 14 predetermined time points using a validated chromatography-tandem mass spectrometry (LC-MS/MS) assay. The C max was 85.3 ± 37.9 pg/mL (min-max 46.7-169 pg/mL) in the 18 mm cohort and 198 ± 81 pg/mL (min-max 82.5-365 pg/mL) in the ≥ 28 mm cohort and no early or late bursts of biolimus A9 release were documented. After 4 weeks, no measurable concentration of biolimus A9 was observed in any patient. Estimated AUC0-t was 1.12 ± 1.16 ng/mL h in the 18 mm group, and 5.93 ± 4.41 ng/mL h for the ≥ 28 mm group. A significant association between loaded biolimus A9 dose adjusted by patient weight and pharmacokinetic parameters was observed. The systemic exposure of biolimus A9 eluting from the Nobori stent was low and proportional to the loaded amount of biolimus A9, and clearance from the blood was rapid. These findings suggest that the Nobori stent is feasible and safe. Systemic lower exposure of biolimus A9 after Nobori stent implantation may have beneficial effects on stent endothelialization. Topics: Aged; Angina Pectoris; Angina, Unstable; Angioplasty, Balloon, Coronary; Area Under Curve; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Japan; Male; Middle Aged; Prospective Studies; Prosthesis Design; Risk Assessment; Sirolimus; Time Factors; Treatment Outcome | 2012 |
Randomized comparison of the Nobori biolimus A9-eluting stent with the sirolimus-eluting stent in patients with stenosis in native coronary arteries.
The aim of this randomized-controlled trial is to compare biolimus A9-eluting stent (Nobori) to sirolimus eluting stent (Cypher).. The Nobori coronary stent is coated only abluminally with a biodegradable polymer, poly-lactic acid, and the antiproliferative agent biolimus A9. This stent has been studied in randomized trials versus Taxus Express and Taxus Liberte and showed noninferiority and superiority for in-stent late loss. This is the first randomized trial of Nobori stent versus Cypher stent.. We conducted a randomized (3:2), controlled trial comparing Nobori and Cypher, in 335 patients (198 Nobori and 137 Cypher) at 15 centers in Japan. Patients with de-novo lesions in up to two native coronary arteries were considered for enrollment. The primary endpoint was freedom from target vessel failure (TVF), a composite of cardiac death, myocardial infarction, and target vessel revascularization at 9 months.. At 9 months, the primary endpoint of freedom from TVF was 92.6% in Nobori and 93.8% in Cypher arm (noninferiority test P < 0.001). As main secondary endpoints, the in-stent late loss was 0.12 ± 0.30 mm and 0.14 ± 0.34 mm in Nobori and Cypher stents, respectively. Target lesion revascularization was 0.5% in Nobori and 3.9% in Cypher treated patients (P = 0.04). Definite and probable stent thromboses were not recorded in any patient.. Despite the relatively small number of patients, this well controlled clinical trial confirmed the primary hypothesis of non-inferiority of the Nobori biolimus A9-eluting stent to the Cypher sirolimus-eluting stent for freedom from TVF. Both stents showed excellent midterm results. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Japan; Lactic Acid; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polyesters; Polymers; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2012 |
Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.
Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year.. The multicentre COMFORTABLE AMI trial (NCT00962416) randomly assigned 1,161 patients to treatment with biolimus-eluting stents with biodegrable polymer and bare metal stents of otherwise identical design at 11 international sites. The primary endpoint is a composite of cardiac death, target-vessel MI and target lesion revascularisation at one year. Assuming a relative risk reduction of 40% in event rates of the primary endpoint in favour of biolimus-eluting stents with biodegradable polymer, 1,064 patients will provide 80% power to demonstrate superiority. Clinical follow-up will be continued through five years.. The COMFORTABLE AMI trial will determine whether biolimus-eluting stents with biodegradable polymer are superior to bare metal stents of otherwise identical design. This is the first randomised controlled trial (RCT) investigating DES with a biodegradable polymer surface coating for drug release in the treatment of patients with STEMI. Topics: Drug-Eluting Stents; Electrocardiography; Humans; Metals; Myocardial Infarction; Polymers; Research Design; Sirolimus | 2012 |
Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.
The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI).. To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI.. A prospective, randomized, single-blinded, controlled trial of 1161 patients presenting with STEMI at 11 sites in Europe and Israel between September 19, 2009, and January 25, 2011. Clinical follow-up was performed at 1 and 12 months.. Patients were randomized 1:1 to receive the biolimus-eluting stent (n = 575) or the bare-metal stent (n = 582).. Primary end point was the rate of major adverse cardiac events, a composite of cardiac death, target vessel-related reinfarction, and ischemia-driven target-lesion revascularization at 1 year.. Major adverse cardiac events at 1 year occurred in 24 patients (4.3%) receiving biolimus-eluting stents with biodegradable polymer and 49 patients (8.7%) receiving bare-metal stents (hazard ratio [HR], 0.49; 95% CI, 0.30-0.80; P = .004). The difference was driven by a lower risk of target vessel-related reinfarction (3 [0.5%] vs 15 [2.7%]; HR, 0.20; 95% CI, 0.06-0.69; P = .01) and ischemia-driven target-lesion revascularization (9 [1.6%] vs 32 [5.7%]; HR, 0.28; 95% CI, 0.13-0.59; P < .001) in patients receiving biolimus-eluting stents compared with those receiving bare-metal stents. Rates of cardiac death were not significantly different (16 [2.9%] vs 20 [3.5%], P = .53). Definite stent thrombosis occurred in 5 patients (0.9%) treated with biolimus-eluting stents and 12 patients (2.1%; HR, 0.42; 95% CI, 0.15-1.19; P = .10) treated with bare-metal stents.. Compared with a bare-metal stent, the use of biolimus-eluting stents with a biodegradable polymer resulted in a lower rate of the composite of major adverse cardiac events at 1 year among patients with STEMI undergoing primary PCI.. clinicaltrials.gov Identifier: NCT00962416. Topics: Absorbable Implants; Aged; Drug-Eluting Stents; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Myocardial Ischemia; Myocardial Reperfusion; Myocardial Revascularization; Polymers; Prospective Studies; Recurrence; Risk; Single-Blind Method; Sirolimus; Treatment Outcome | 2012 |
Randomized, double-blind, placebo-controlled, single intravenous dose-escalation study to evaluate the safety, tolerability, and pharmacokinetics of the novel coronary smooth muscle cell proliferation inhibitor Biolimus A9 in healthy individuals.
Biolimus A9 (BA9) is a novel proliferation inhibitor of coronary smooth muscle cells that has been specifically designed for coating drug-eluting stents. The goals of this study were to identify the highest safe intravenous dose of BA9, to evaluate the dose-dependent pharmacokinetics of BA9 after intravenous administration in humans, and to characterize early clinical symptoms of BA9 toxicity in healthy subjects. This phase 1 trial in healthy subjects was designed as a double-blind, placebo-controlled, randomized, ascending single-dose study. After screening and randomization, 28 volunteers received either placebo (n = 7) or BA9 (n = 21) in a double-blinded fashion. Doses from 0.0075 mg/kg were escalated to 0.25 mg/kg in 4 cohorts. BA9 concentrations were measured using liquid chromatography-tandem mass spectrometry. BA9 doses up to 0.075 mg/kg were well tolerated. Only the highest BA9 dose of 0.25 mg/kg produced reversible drug-related adverse events. The most frequent adverse events were headache, nausea, and mouth ulcers, most likely due to immunosuppression. Exposure to BA9 did not result in electrocardiographic or clinical laboratory changes. BA9 had a terminal half-life of 90.0 ± 40.0 hours (all n = 21, mean ± standard deviation), an apparent clearance from blood of 0.96 ± 1.07 L/kg/h, and a volume of distribution of 96.5 ± 72.6 L/kg. Topics: Adult; Cell Proliferation; Chromatography, Liquid; Dose-Response Relationship, Drug; Double-Blind Method; Female; Half-Life; Humans; Immunosuppressive Agents; Infusions, Intravenous; Male; Middle Aged; Myocytes, Smooth Muscle; Sirolimus; Tandem Mass Spectrometry; Tissue Distribution; Young Adult | 2011 |
The pharmacokinetics of Biolimus A9 after elution from the BioMatrix II stent in patients with coronary artery disease: the Stealth PK Study.
This prospective, open-label multicenter study was conducted to assess the pharmacokinetics of Biolimus A9 after elution from BioMatrix II coronary stents. Recent clinical trials have demonstrated the efficacy and safety of Biolimus A9 eluted from different stent platforms. To date, the pharmacokinetics of Biolimus A9 in patients following the deployment of BioMatrix II stents has not yet been studied. BioMatrix II stents were implanted into 27 patients with coronary artery disease. The primary endpoints of the study were the systemic concentrations of Biolimus A9 after 28 days and 6 months as measured using a sensitive validated liquid chromatography-tandem mass spectrometry assay.. The highest measured blood concentration at any time point was 394 pg/mL. At 28 days and 6 months following stent placement, 51.8 and 100% of patients, respectively, had Biolimus A9 concentrations <10 pg/mL. After 9 months, 100% of the patients were free of major cardiac adverse events (MACE). There was no Biolimus A9 toxicity, no cardiac or non-cardiac deaths, no myocardial infarctions, nor target vessel or target lesion revascularizations during the 9 months of follow-up. No case of acute, subacute, or late stent thrombosis was detected.. Compared to other drug-eluting stents, such as Cypher, BioMatrix II results in relatively low systemic exposure, which may be explained by the ablominal coating of the Biomatrix II stent in combination with Biolimus A9's high lipophilicity. Topics: Aged; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Sirolimus; Treatment Outcome | 2011 |
The outcome of bifurcation lesion stenting using a biolimus-eluting stent with a bio-degradable polymer compared to a sirolimus-eluting stent with a durable polymer.
This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.. The clinical outcomes were assessed in the 497 patients (BES 258, SES 239) enrolled in the multicentre, randomised LEADERS trial who underwent treatment of ≥1 BL (total=534 BL). At 12-months follow-up there was no significant difference in the primary endpoint of MACE, a composite of cardiac death, myocardial infarction and clinically indicated target vessel revascularisation (BES 12.8% vs. SES 16.3%, p=0.31). Patients treated with BES had comparable rates of cardiac death (BES 2.7% vs. SES 2.9%, p=1.00), numerically higher rates of myocardial infarction (BES 8.9% vs. SES 5.4%, p=0.17), and significantly lower rates of clinically indicated target vessel revascularisation (4.3% vs. 11.3%, p=0.004) when compared to those treated with SES. The rate of stent thrombosis at 12-months was 4.3% and 3.8% for BES and SES, respectively (p=0.82).. In the treatment of BL the use of BES lead to superior efficacy and comparable safety compared to SES. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Sirolimus; Treatment Outcome | 2011 |
Angioscopic assessment of arterial repair following biodegradable polymer-coated biolimus A9-eluting stent implantation. - Comparison with durable polymer-coated sirolimus-eluting stent-.
Second-generation drug-eluting stents (DES) are expected to show better arterial repair than older DES. We angioscopically compared the biodegradable polymer-coated biolimus A9-eluting stent (BES) and durable polymer-coated sirolimus-eluting stent (SES) to explore differences in arterial repair.. Angioscopy was performed 9 ± 1 months after 15 BES and 16 SES were implanted initially in the native coronary artery. Heterogeneity of neointimal coverage (NIC) as well as the dominant NIC grade was examined. NIC was defined as: grade 0 = fully visible struts; grade 1 = struts bulging into the lumen, but covered; grade 2 = embedded, but translucent struts; grade 3 = invisible struts. Heterogeneity was judged when the NIC grade varied ≥ 1. In-stent late loss (0.06 ± 0.23 vs. 0.07 ± 0.18 mm, P = 0.80), and dominant NIC grade (1.5 ± 0.8 vs. 1.3 ± 0.7, P = 0.45) were similar for BES and SES. Within the stents, NIC was more heterogeneous in SES than in BES (P = 0.035). 80% of BES showed homogeneous NIC, while 56% of SES had heterogeneous NIC.. BES showed limited late loss similar to that for SES. Nonetheless, the NIC with BES was more homogeneous than that with SES. Biodegradable polymer-coated BES may have an advantage in homogeneous NIC. Topics: Aged, 80 and over; Angioscopy; Coated Materials, Biocompatible; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Polymers; Sirolimus; Treatment Outcome; Tunica Intima; Wound Healing | 2011 |
2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up.. BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest.. A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population.. At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, p(noninferiority) < 0.0001, p(superiority) = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group.. At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220). Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Survival Rate; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Implantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score is associated with decreased cardiac mortality compared to a permanent polymer sirolimus-eluting stent: two year follow-up results from the "all-comers" LE
The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI).. The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 8 Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Heart Diseases; Humans; Male; Middle Aged; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2011 |
The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES).. One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE.. The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial.
The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers.. We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220.. 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049).. Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES.. Biosensors Europe SA, Switzerland. Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Follow-Up Studies; Humans; Polymers; Sirolimus; Thrombosis | 2011 |
An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study.
Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial.. Fifty-six consecutive patients underwent OCT during angiographic follow-up at 9 months. OCT images were acquired using a non-occlusive technique at a pullback speed of 3 mm/s. Data were analysed using a Bayesian hierarchical random-effects model, which accounted for the correlation of lesion characteristics within patients and implicitly assigned analytical weights to each lesion depending on the number of struts observed per lesion. Primary outcome was the difference in percentage of uncovered struts between BESs and SESs. Twenty patients were included in the analysis in the BES group (29 lesions with 4592 struts) and 26 patients in the SES group (35 lesions with 6476 struts). A total of 83 struts were uncovered in the BES group and 407 out of 6476 struts were uncovered in the SES group [weighted difference -1.4%, 95% confidence interval (CI) -3.7 to 0.0, P = 0.04]. Results were similar after adjustment for pre-procedure lesion length, reference vessel diameter, number of implanted study stents, and presence of stent overlap. There were three lesions in the BES group and 15 lesions in the SES group that had > or =5% of all struts uncovered (difference -33.1%, 95% CI -61.7 to -10.3, P < 0.01).. Strut coverage at an average follow-up of 9 months appears to be more complete in patients allocated to BESs when compared with SESs. The impact of this difference on clinical outcome and, in particular, on the risk of late stent thrombosis is yet to be determined. Topics: Absorbable Implants; Coronary Restenosis; Drug-Eluting Stents; Female; Graft Occlusion, Vascular; Humans; Male; Middle Aged; Polymers; Sirolimus; Tomography, Optical Coherence; Treatment Outcome; Tubulin Modulators | 2010 |
The impact of body mass index on the one year outcomes of patients treated by percutaneous coronary intervention with Biolimus- and Sirolimus-eluting stents (from the LEADERS Trial).
The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel. Topics: Aged; Angioplasty, Balloon, Coronary; Body Mass Index; Confidence Intervals; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Netherlands; Obesity; Odds Ratio; Overweight; Predictive Value of Tests; Proportional Hazards Models; Risk Factors; Sirolimus; Survival Analysis; Treatment Outcome | 2010 |
The twelve-month outcomes of a biolimus eluting stent with a biodegradable polymer compared with a sirolimus eluting stent with a durable polymer.
This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES).. The multicentre LEADERS trial employed an all-comers approach to recruit 1,707 patients who were randomised to treatment with either BES (n=857) or SES (n=850) in a non-inferiority design. The primary clinical endpoint of this study was a composite of cardiac death, myocardial infarction and clinical-indicated target vessel revascularisation. Follow-up was obtained in 97.6% of patients. At 12 months, BES remained non-inferior compared to SES for the primary endpoint (BES 10.6% vs. SES 12.0%, HR:0.88, 95% CI:0.66-1.17, p=0.37). Rates of cardiac death (2.1% vs. 2.7%, HR:0.77, 95% CI:0.42-1.44, p=0.42), MI (5.8% vs. 4.6%, HR:1.27, 95% CI:0.84-1.94, p=0.26) and clinically-indicated target vessel revascularisation (5.8% vs. 7.1%, HR:0.82, 95%CI:0.56-1.19, p=0.29) were similar for BES and SES. Similarly, there was no difference in the incidence of definite stent thrombosis at 12 months.. These findings support the safety and efficacy of the BES stent with a biodegradable polymer at 12-month clinical follow-up, and suggest it is a suitable alternative to the SES stent with a durable polymer. Topics: Absorbable Implants; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Lactic Acid; Male; Middle Aged; Polyesters; Polymers; Prospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2010 |
Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial.
To assess the efficacy of the AXXESS stent on the treatment of left main coronary artery (LMCA) bifurcation lesions using IVUS.. The treatment of LMCA bifurcation lesions remains challenging even with the use of drug-eluting stents. The AXXESS system is a biolimus A9-eluting self-expanding stent, dedicated to the treatment of bifurcation lesions.. Data were obtained from the AXXENT trial, a prospective, single-arm, multicenter study designed to evaluate the efficacy of the AXXESS stent on the treatment of LMCA bifurcation lesions. IVUS was available in 26 cases at 6-months follow-up. Volumetric and cross-sectional analyses within the AXXESS stent, and cross-sectional analyses at the ostia of left anterior descending (LAD) and left circumflex coronary arteries (LCX) were performed.. Within the AXXESS stent, percent neointimal volume obstruction was (3.0 +/- 4.1)% with a minimal lumen area of 10.3 +/- 2.6 mm(2). AXXESS stent volume showed an 12.4% increase at follow-up compared with postprocedure (P = 0.04). Lumen area was significantly smaller in the LCX ostium compared with the LAD ostium at follow-up (3.6 +/- 1.3 mm(2) vs. 5.5 +/- 2.0 mm(2), P = 0.0112). There was greater neointimal formation in the LCX ostium compared with the LAD ostium (1.37 +/- 1.20 mm(2) vs. 0.30 +/- 0.36 mm(2), P = 0.0003).. The AXXESS stent in the LMCA showed enlargement through 6-months follow-up and significant neointimal suppression. Greater neointimal formation and relatively inadequate stent expansion may contribute to luminal narrowing in the LCX ostium. Topics: Aged; Alloys; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Prospective Studies; Prosthesis Design; Sirolimus; Stents; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional; United States | 2009 |
9-month clinical, angiographic, and intravascular ultrasound results of a prospective evaluation of the Axxess self-expanding biolimus A9-eluting stent in coronary bifurcation lesions: the DIVERGE (Drug-Eluting Stent Intervention for Treating Side Branche
This study sought to assess the safety and performance of the Axxess (Devax Inc., Lake Forest, California) self-expanding drug-eluting stent in coronary bifurcation lesions.. Percutaneous treatment of coronary bifurcations is a predictor of adverse late outcomes, in part because of the lack of dedicated devices.. Patients with de novo bifurcation lesions were prospectively enrolled in a multicenter study. The Axxess stent was deployed at the level of the carina followed by additional sirolimus-eluting stents in the distal parent vessel (PV) and/or side branch (SB). All patients underwent clinical follow-up at 9 months; 150 were to receive control angiography and 76 were to receive intravascular ultrasound. The primary end point was the rate of major adverse cardiac events (MACE): a composite of death, myocardial infarction (MI), and target lesion revascularization (TLR). Secondary end points included in-segment restenosis, late loss, and percent neointimal volume obstruction.. Overall, 302 patients were treated with 299 Axxess stents (99%). Additional stenting of 1 branch was performed in 21.7% of patients (17.7% PV, 4% SB), and of both branches in 64.7%. At 9 months, 99.3% of patients returned for clinical follow-up; from the angiographic and IVUS substudies, 93.3% and 89.4% returned. The cumulative 9-month MACE rate was 7.7% (0.7% death, 3.3% non-Q-wave MI, 1.0% Q-wave MI, 4.3% TLR). Subacute and late stent thrombosis occurred in 0.7% and 0.3% of patients. Total restenosis was 6.4% (3.6% PV, 4.3% SB), late loss was 0.20 +/- 0.41 mm in the PV and 0.17 +/- 0.34 mm in the SB. In the Axxess stent segment, percent neointimal volume obstruction was 4.3 +/- 5.2%.. This prospective multicenter study confirms the safety and performance of the Axxess stent in bifurcation lesions. (Drug-Eluting Stent Intervention for Treating Side Branches Effectively; ACTRN12606000259549). Topics: Aged; Coronary Angiography; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Prospective Studies; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2009 |
Biolimus-eluting biodegradable polymer versus sirolimus-eluting permanent polymer stent performance in long lesions: results from the LEADERS multicentre trial substudy.
Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions.. A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group.. BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Myocardial Infarction; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Impact of vessel size on angiographic and clinical outcomes of revascularization with biolimus-eluting stent with biodegradable polymer and sirolimus-eluting stent with durable polymer the LEADERS trial substudy.
We assessed the impact of vessel size on outcomes of stenting with biolimus-eluting degradable polymer stent (BES) and sirolimus-eluting permanent polymer stent (SES) within a randomized multicenter trial (LEADERS).. Stenting of small vessels might be associated with higher rates of adverse events.. "All-comer" patients (n = 1,707) were randomized to BES and SES. Post-hoc-stratified analysis of angiographic and clinical outcomes at 9 months and 1 year, respectively, was performed for vessels with reference diameter Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Severity of Illness Index; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Randomized comparison of the Nobori Biolimus A9-eluting coronary stent with the Taxus Liberté paclitaxel-eluting coronary stent in patients with stenosis in native coronary arteries: the NOBORI 1 trial--Phase 2.
The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation.. We conducted a randomized (2:1), controlled trial comparing the Biolimus A9-eluting stent Nobori and the paclitaxel-eluting stent Taxus Liberté, in 243 patients (153 Nobori and 90 Taxus) at 29 centers in Europe, Asia, and Australia. Patients with previously untreated lesions in up to 2 native coronary arteries were considered for enrollment. The primary end point was in-stent late loss at 9 months, whereas secondary end points included other quantitative coronary angiography parameters, such as in-segment late loss and the rate of restenosis as well as key intravascular ultrasound parameters. Clinical secondary end points were stent thrombosis and composite of major adverse cardiac events comprising death, myocardial infarction, and target vessel revascularization. At 9 months, the in-stent late loss was significantly lower in the Nobori group compared with the Taxus group (0.11+/-0.30 mm versus 0.32+/-0.50 mm) reaching both the primary hypothesis of noninferiority of Nobori stent versus Taxus Liberté stent (P<0.001) and the secondary hypothesis of superiority (P=0.001). This finding was confirmed by a significant reduction in binary restenosis from 6.2% in Taxus to 0.7% in Nobori (P=0.02) and neointimal volume obstruction, detected by intravascular ultrasound, from 5.5+/-7.2% in Taxus to 1.8+/-5.2% in Nobori (P=0.01). The major adverse cardiac events rate was 4.6% in the Nobori and 5.6% in the Taxus cohort of patients. The stent thrombosis rate was 0% in the Nobori arm and 4.4% in the Taxus arm.. The NOBORI 1 clinical trial confirmed its primary hypothesis--noninferiority of the Nobori Biolimus A9-eluting stent versus the Taxus Liberté stent in reducing neointimal proliferation. Both stents showed a low major adverse cardiac events rate in the studied population. Topics: Angioplasty, Balloon, Coronary; Asia; Australia; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Europe; Female; Humans; Hyperplasia; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Prospective Studies; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2009 |
Differential effects of drug-eluting stents on local endothelium-dependent coronary vasomotion.
The aim of our study was to compare coronary vasomotion after implantation of a second-generation biolimus A9-eluting stent (BES) and of a sirolimus-eluting stent (SES).. Drug-eluting stents (DES) have been associated with impaired local coronary vasomotion, delayed endothelialization, and increased late thrombotic risk. New DES with different drugs, pharmacokinetics, and polymers have been developed.. Nineteen patients with a BES and 15 patients with a SES were studied 9 months after stent implantation. Endothelium-dependent and -independent coronary vasomotion were tested proximally and distally to the stent as well as at a reference segment during right atrial pacing at increasing heart rates. Quantitative coronary angiographic measurements were performed offline.. Of the patients with BES, 2 showed vasoconstriction with increased heart rate and 17 showed vasodilatation. Of the patients with a SES, 9 showed vasoconstriction while 6 showed vasodilatation. The SES showed significant vasoconstriction at both the proximal (-2.3 +/- 10% vs. 7.9 +/- 10%) and the distal (-5.4 +/- 9% vs. 6.1 +/- 8%) segments to the stent compared with the BES (p = 0.003 for proximal, p < 0.001 for distal segment). Endothelium-independent vasomotion after intracoronary nitrates did not differ significantly between the 2 groups (p = NS for proximal and distal segment).. Unlike the case with the SES, endothelium-dependent vasomotion at adjacent stent segments seems to be preserved after BES implantation. This result may be explained by the different drug release kinetics, DES design, or characteristics of polymer used in the stent system. Topics: Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Endothelium, Vascular; Female; Hemodynamics; Humans; Immunosuppressive Agents; Male; Middle Aged; Paclitaxel; Prospective Studies; Sirolimus; Vasoconstriction; Vasodilation | 2008 |
Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial.
A novel stent platform eluting biolimus, a sirolimus analogue, from a biodegradable polymer showed promising results in preliminary studies. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with a sirolimus-eluting stent (with durable polymer).. We undertook a multicentre, assessor-blind, non-inferiority study in ten European centres. 1707 patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes were centrally randomised by a computer-generated allocation sequence to treatment with either biolimus-eluting (n=857) or sirolimus-eluting (n=850) stents. The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation within 9 months. Analysis was by intention to treat. 427 patients were randomly allocated to angiographic follow-up, with in-stent percentage diameter stenosis as principal outcome measure at 9 months. The trial is registered with ClinicalTrials.gov, number NCT00389220.. We analysed all randomised patients. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents for the primary endpoint at 9 months (79 [9%] patients vs 89 [11%], rate ratio 0.88 [95% CI 0.64-1.19], p for non-inferiority=0.003, p for superiority=0.39). Frequency of cardiac death (14 [1.6%] vs 21 [2.5%], p for superiority=0.22), myocardial infarction (49 [5.7%] vs 39 [4.6%], p=0.30), and clinically-indicated target vessel revascularisation (38 [4.4%] vs 47 [5.5%], p=0.29) were similar for both stent types. 168 (79%) patients in the biolimus-eluting group and 167 (78%) in the sirolimus-eluting group had data for angiographic follow-up available. Biolimus-eluting stents were non-inferior to sirolimus-eluting stents in in-stent percentage diameter stenosis (20.9%vs 23.3%, difference -2.2% [95% CI -6.0 to 1.6], p for non-inferiority=0.001, p for superiority=0.26).. Our results suggest that a stent eluting biolimus from a biodegradable polymer represents a safe and effective alternative to a stent eluting sirolimus from a durable polymer in patients with chronic stable coronary artery disease or acute coronary syndromes.. Biosensors Europe SA, Switzerland. Topics: Absorbable Implants; Aged; Biocompatible Materials; Chronic Disease; Coronary Disease; Drug-Eluting Stents; Female; Humans; Male; Materials Testing; Metals; Middle Aged; Polymers; Sirolimus; Thrombosis; Treatment Outcome | 2008 |
The pharmacokinetics of Biolimus A9 after elution from the Nobori stent in patients with coronary artery disease: the NOBORI PK study.
The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents.. : The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents.. Twenty patients with coronary artery disease were treated with single 14-mm (10 patients) or 28-mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay.. At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters.. Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chromatography, Liquid; Colorado; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Prospective Studies; Prosthesis Design; Serbia; Sirolimus; Tandem Mass Spectrometry; Treatment Outcome | 2008 |
One year results of a new in situ length-adjustable stent platform with a biodegradable biolimus A9 eluting polymer: results of the CUSTOM-II trial.
To assess the safety and efficacy of the XTENT customisable drug-eluting stent system in the treatment of patients with single long or multiple coronary lesions referred for PCI.. The CUSTOM-II trial enrolled 100 patients with de novo lesions in native coronary arteries presenting with either single long lesions (n=69) of > or =20 mm length or up to two lesions with a total cumulative anticipated stent length of 60 mm of stent (n=31). Patients were assessed angiographically at six months, and clinically at one year. Of the 100 patients enrolled, nine patients experienced a MACE, including five patients whose MACE occurred during index hospitalisation (two non-Q-MI, two Q-MI and one probable stent thrombosis-related death), and four target lesion revascularisations (TLR) at six months. No MACE or stent thrombosis was reported between six and 12 months follow-up. In-segment late loss at 6-months was 0.22 +/- 0.28 mm, and in-stent late loss had a range of 0.31 +/- 0.31 mm.. The XTENT customisable stent is clinically safe and efficacious as judged by angiographic and clinical variables through 12 months follow-up. Further follow-up and larger randomised comparative studies are needed for its clinical positioning. Topics: Aged; Angioplasty, Balloon, Coronary; Coated Materials, Biocompatible; Coronary Angiography; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Ischemia; Risk Factors; Sirolimus; Treatment Outcome | 2008 |
Novel drug eluting stent system for customised treatment of coronary lesions: CUSTOM I feasibility trial 24 month results.
The Custom NX 36 Drug Eluting Stent (DES) System is designed to treat coronary lesions via in situ stent length customisation. The stent evaluated in this study consists of nine interdigitated stent segments, each 4 mm in length, coated with a biodegradable formulation of Biolimus A9 and Poly-Lactic-Acid, a biodegradable drug carrier, and loaded into a unique sheath protected, integrated balloon delivery system.. The objective of this non-randomised prospective multicentre CUSTOM I Trial was to demonstrate the safety of in situ stent length customisation in 30 consecutive patients. Angiographic (QCA) and intravascular ultrasound (IVUS) follow-up was performed at two cohort time intervals: four (n=10) or eight (n=20) months. Mean lesion length and reference vessel diameters were 17.7 +/- 9.6 mm and 2.6 +/- 0.3 mm, respectively. Procedural success was 93%. There were three MACEs in the study population from enrollment through to twenty-four month follow-up. The in-hospital MACE rate was 2/30, with non-Q-wave myocardial infarctions events in two patients who recovered without further sequelae. At five months, one patient who had crossed over initially to PTCA required CABG surgery. Results from QCA and IVUS assessments at four and eight months showed no binary restenosis, mean in-stent late luminal loss of 0.25 +/- 0.23 mm and 0.26 +/- 0.23 mm.. This first evaluation of the new customisable Biolimus A9-eluting Custom NX stent suggests safety and efficacy through twenty-four month follow-up. Further evaluations are warranted to confirm the overall favourable outcomes. Topics: Aged; Angioplasty, Balloon, Coronary; Coated Materials, Biocompatible; Coronary Artery Disease; Drug Delivery Systems; Drug-Eluting Stents; Feasibility Studies; Female; Follow-Up Studies; Humans; Lactic Acid; Male; Middle Aged; Polyesters; Polymers; Prospective Studies; Sirolimus; Treatment Outcome | 2008 |
Analysis of bifurcation lesions treated with novel drug-eluting dedicated bifurcation stent system: intravascular ultrasound results of the AXXESS PLUS trial.
The aim of this intravascular ultrasound (IVUS) study was to assess the efficacy of the AXXESS Plus stent system for the treatment of bifurcation coronary lesions.. The AXXESS Plus is a novel bifurcation drug-eluting stent, comprised of a self-expanding flare-shaped stent platform and bioabsorbable polymer coating that releases Biolimus A9.. Data were obtained from the AXXESS PLUS trial, a prospective, multicenter, nonrandomized, single-arm study to evaluate safety and efficacy. Six-month follow-up IVUS analysis was available in 49 cases. Volumetric analysis using Simpson's method within the AXXESS stent, and cross-sectional analysis at the ostium of main branch and/or side branch was performed. Impact of bifurcation angle on stent expansion at the carina was also evaluated.. Within the AXXESS stent, neointimal volume obstruction percentage was 2.3% +/- 2.2%, with a minimum lumen area of 7.9 +/- 2.6 mm(2). Lumen area was 5.2 +/- 1.7 mm(2) at main branch ostium, and 4.0 +/- 1.5 mm(2) at side branch ostium. In two cases, incomplete stent apposition was observed at the proximal edge of the AXXESS stent. In one case, a gap between the AXXESS stent and an additional stent was observed. Greater bifurcation angle inversely correlated with smaller stent area at side branch ostium (r = -0.54, P = 0.03) but not at main branch ostium (r = -0.2, P = 0.29).. This novel self-expanding, drug-eluting bifurcation stent demonstrated effective lesion coverage along with significant neointimal suppression equivalent to current generation balloon-expandable drug-eluting stent technology. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Hyperplasia; Male; Middle Aged; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional | 2007 |
117 other study(ies) available for sirolimus and umirolimus
Article | Year |
---|---|
Developmental and reproduction toxicity studies of Biolimus A9 in SD rats.
Biolimus A9 (BA9) is a novel rapamycin derivative. In this report we evaluated the potential toxicity of BA9 in a developmental and reproduction toxicity study (segment Ⅰ, Ⅱ, Ⅲ). In segment I, body weight gains in F0 rats receiving 0.80 mg/kg/day were decreased. A lower fertility index of males was observed and females failed to become pregnant in the 0.80 mg/kg/day group. The number of live fetuses and implantations were decreased while the number of dead fetuses, resorptions, and implantation losses were increased in the 0.12 mg/kg/day group. In segment Ⅱ, maternal toxicity: body weight gains in F0 females receiving 0.036 and 0.090 mg/kg/day group were decreased. Embryo toxicity: In the 0.090 mg/kg/day group, weights and body lengths of fetuses were decreased, the numbers of viable fetuses was decreased and resorbed fetuses increased. Teratogenic effects: The percent of visceral variations and skeletal variations were both increased in the 0.090 mg/kg/day group. In segment Ⅲ, dosing F0 rats with BA9 at dose levels of 0.12 and 0.80 mg/kg/day resulted in reproductive and maternal toxicity, consisting of prolonged labor, dystocia, increased mortality, along with reductions in lactation food consumption. F1 rats in the 0.12 mg/kg/day group showed reproductive and developmental toxicity consisting of body weight decreases, decreased food consumption after weaning and a reduction in the gestation index of pregnant rats. Based on these findings, the no-observed-adverse-effect-level (NOAEL) of BA9 toxicity in segment Ⅰ and Ⅲ was 0.02 mg/kg/day. The NOAEL in segment Ⅱ was 0.015 mg/kg/day. Topics: Animals; Body Weight; Female; Male; Pregnancy; Rats; Rats, Sprague-Dawley; Reproduction; Sirolimus | 2023 |
Polymer-free biolimus-A9-eluting stent performance according to renal impairment: insights from the RUDI-FREE registry.
Patients with chronic kidney disease (CKD) are at increased risk of cardiovascular disease and have a worse prognosis after percutaneous coronary interventions (PCI). The BioFreedom polymer-free biolimus-A9-eluting stent (PF-BES) has shown promising results in patients at high bleeding risk; however, its performance in CKD patients has yet to be analyzed.. The all-comers RUDI-FREE registry documented patients undergoing PCI with PF-BES in routine clinical practice. Patients were stratified into three groups according to their estimated glomerular filtration rate (eGFR): preserved renal function, mild renal insufficiency (RI), and with moderate to severe RI (eGFR ≥ 90, between 90 and 45, and <45 ml/min/1.73 m2, respectively). The primary safety end point was a patient-oriented composite end point of cardiovascular death, myocardial infarction (MI), and definite or probable stent thrombosis (ST). The primary efficacy end point was target lesion revascularization (TLR).. The registry documented 1,104 consecutive patients treated with PF-BES: 258 (23.4%) with preserved renal function, whereas 712 (64.7%) and 131 (11.9%) had mild and moderate to severe RI, respectively. At 1 year, the primary safety end point was significantly higher in patients with moderate to severe RI (3.5% vs. 2.8% vs. 11.5%; P < 0.001). Conversely, TLR proved similar among groups (0.4% vs. 1.8% vs. 0.8%; P = 0.235).. Patients with worse renal function had increased risk of the composite of cardiovascular deaths, MI, and definite or probable ST. However, the PF-BES showed similar efficacy despite differences in renal function. These findings need to be confirmed in large-scale randomized trials. Topics: Aged; Cardiovascular Diseases; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Renal Insufficiency, Chronic; Sirolimus; Thrombosis | 2022 |
Comparison of 1-Month and 12-Month Vessel Responses Between the Polymer-Free Biolimus A9-Coated Stent and the Durable Polymer Everolimus-Eluting Stent.
A polymer-free biolimus A9-coated stent (PF-BCS) may achieve better arterial healing than a durable polymer drug-eluting stent owing to its polymer-free feature.Methods and Results: This multicenter, prospective, observational study enrolled 105 patients (132 lesions) who underwent PF-BCS (51 patients, 71 lesions) or durable polymer everolimus-eluting stent (DP-EES, 54 patients, 61 lesions) implantation. Serial coronary angioscopy (CAS) and optical coherence tomography (OCT) examinations were performed at 1 and 12 months, and the serial vessel responses were compared between PF-BCS and DP-EES. The primary outcome measure was the incidence of subclinical intrastent thrombus on CAS. The secondary outcome measures were: adequate strut coverage (≥40 μm) on OCT and maximum yellow color grade on CAS. The incidence of thrombus was high at 1 month (100% vs. 93%, P=0.091), but decreased at 12 months (18% vs. 25%, P=0.56), without a significant difference between PF-BCS and DP-EES. The adequate strut coverage rate was significantly higher (84±14% vs. 69±22%, P<0.001) and yellow color was significantly less intense (P=0.012) at 12 months in PF-BCS than in DP-EES; however, they were not significantly different at 1 month (adequate strut coverage: 47±21% vs. 50±17%, P=0.40; yellow color: P=0.99).. Although the thrombogenicity of PF-BCS was similar to that of DP-EES, the adequate coverage and plaque stabilization rates of PF-BCS were superior to those of DP-EES at 12 months. Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Humans; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Sirolimus; Thrombosis; Treatment Outcome | 2022 |
Real-world analysis of a Biolimus A9 polymer-free drug-coated stent with very short dual antiplatelet therapy in patients at high bleeding risk.
Patients at high risk of bleeding requiring percutaneous coronary intervention (PCI) need careful evaluation of both their thrombotic and their bleeding risks. In these patients, a polymer-free metallic stent coated with biolimus-A9 (BA9-DCS) followed by 1‑month dual antiplatelet therapy (DAPT) could be a safe option; however, real-world data are still lacking. We analyzed the performance of the device in a real-world scenario.. Patients assessed as being at high risk of bleeding with an indication for PCI were treated with BA9-DCS and DAPT consisting of aspirin (100 mg/day) and clopidogrel (75 mg/day) for at least 1 month, followed by either oral anticoagulation or single antiplatelet therapy. No exclusion criteria were used. The primary endpoint was the occurrence of an adverse event after PCI, i.e. severe bleeding requiring hospitalization, ischemic or hemorrhagic stroke, clinically driven stent thrombosis, myocardial infarction or cardiac death.. Overall, 89 patients were enrolled in this study [median age 75 (66-81) years; 27 females (30%)] and 171 interventions were performed. During a median follow-up of 203 (145-273) days the primary endpoint occurred in 20 patients (23%): 12 (13%) had clinically significant bleeding, four (5%) ischemic stroke and four (5%) died from cardiac causes related neither to stent thrombosis nor to acute myocardial infarction. Female gender emerged as the only statistically significant predictor of an adverse event (adjusted hazard ratio (HR) 3.3; 95% confidence interval (CI): 1.2-8.7, p = 0.017).. In real-world patients at high risk of bleeding, implantation of the polymer-free metallic stent coated with Biolimus-A9 (Biofreedom®; Biosensors Europe, Morges, Switzerland) followed by 1 -month DAPT showed encouraging results without any stent thrombosis.. HINTERGRUND: Patienten mit hohem Blutungsrisiko, bei denen eine perkutane Koronarintervention (PCI) notwendig ist, müssen sorgfältig bezüglich ihres Thrombose- wie auch Blutungsrisikos beurteilt werden. Bei ihnen könnte der Einsatz eines mit Biolimus A9 beschichteten polymerfreien Metallstents (BA9-DCS) mit nachfolgender 1‑monatiger dualer Plättchenhemmung („dual antiplatelet therapy“ [DAPT]) eine sichere Option sein. Es fehlen allerdings immer noch Daten aus der Praxis. Daher haben wir den BA9-DCS unter Realbedingungen untersucht.. Patienten mit hohem Blutungsrisiko und Indikation zur PCI wurden mit BA9-DCS und einer DAPT (Acetylsalicylsäure 100 mg/Tag und Clopidogrel 75 mg/Tag für mindestens 1 Monat) behandelt, worauf eine orale Antikoagulation oder einfache Plättchenhemmung folgte. Ausschlusskriterien gab es nicht. Als primärer Endpunkt wurde der Eintritt eines unerwünschten Ereignisses nach PCI definiert (schwere Blutung mit erforderlicher Krankenhausaufnahme, ischämischer oder hämorrhagischer Schlaganfall, klinisch begünstigte Stentthrombose, Myokardinfarkt oder kardial bedingter Tod).. Insgesamt 89 Patienten wurden in die Studie eingeschlossen (medianes Alter 75 [66–81] Jahre; 27 weiblich [30 %]); es wurden 171 Interventionen durchgeführt. In einem medianen Follow-up von 203 (145–273) Tagen wurde der primäre Endpunkt bei 20 Patienten (23 %) erreicht: 12 (13 %) hatten eine klinisch relevante Blutung, 4 (5 %) einen ischämischen Schlaganfall und 4 (5 %) verstarben kardial bedingt, wobei die Ursache weder mit einer Stentthrombose noch mit einem akuten Myokardinfarkt zusammenhing. Weibliches Geschlecht erwies sich als einziger statistisch signifikanter Prädiktor für ein unerwünschtes Ereignis (adjustierte Hazard Ratio [HR] 3,3; 95 %-Konfidenzintervall [KI]: 1,2–8,7, p = 0,017).. Bei Patienten unter Realbedingungen mit hohem Blutungsrisiko lieferte die Implantation des mit Biolimus A9 beschichteten polymerfreien Metallstents (Biofreedom®, Biosensors Europe, Morges, Schweiz) gefolgt von einer 1‑monatigen DAPT vielversprechende Ergebnisse, ohne dass es zu einer Stentthrombose kam. Topics: Aged; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Sirolimus; Switzerland; Treatment Outcome | 2021 |
The Biolimus A9-coated BioFreedom
In this state-of-the-art review, we present the findings and a critical analysis of the Leaders Free trial program, evaluating outcomes of a new stent-generation based on polymer-free technology, in this case the BioFreedom Topics: Coronary Artery Disease; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Prosthesis Design; Sirolimus; Stents; Treatment Outcome | 2021 |
One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries.
Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice.. A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events.. The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43).. These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES. Topics: Aged; Biocompatible Materials; Chromium Alloys; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Equipment Failure Analysis; Female; Humans; Immunosuppressive Agents; Male; Percutaneous Coronary Intervention; Postoperative Complications; Prosthesis Design; Registries; Sirolimus; Survival Analysis | 2021 |
Angioscopic assessments and clinical outcomes one year after polymer-free biolimus A9-coated coronary stent implantation.
Polymer-free biolimus A9-coated coronary stent (DCS) has novel features which lead to the expectation of better arterial healing. However, comparisons of intravascular status between DCS and drug-eluting stents (DES), and robust real-word clinical assessments of DCS have been lacking to date.. From September 2017 to September 2018, we evaluated the intra-vascular status of 74 DCS implanted in 55 lesions from 43 patients using coronary angioscopy (CAS) approximately one year after implantation from a cohort of 219 lesions in 158 patients. We set 239 second-generation durable-polymer DES (DP-DES) implanted in 211 lesions from 180 patients from a cohort of 2652 lesions in 1914 patients as the control. Angioscopic images were analyzed to determine (1) the dominant degree of neointimal coverage (NIC) over the stent; (2) the heterogeneity of NIC; (3) yellow color grade of the stented segment; and (4) the presence of intra-stent thrombus. The primary outcome was the incidence of thrombus and secondary outcomes were the other CAS findings, and the 1-year clinical outcomes which included target lesion revascularization (TLR) and major adverse cardiac events (MACE). To minimize inter-group differences in baseline characteristics, propensity score matching was performed for clinical outcomes.. Incidence of thrombus adhesion was similar in DCS and DP-DES groups (28.4% versus 22.6%, p=0.31). However, the dominant NIC grade was significantly higher in DCS (p<0.001), while NIC was more heterogeneous in DCS than in DP-DES (p=0.001). Maximum yellow color grade was similar (p=0.22). After propensity score matching, 202 lesion pairs from 146 patient pairs were retained for analysis. The cumulative incidence of TLR (4.6% versus 3.8%, p=0.38) and MACE (11.6% versus 11.7%, p=0.84) was similar for DCS and DP-DES.. DCS showed thrombus adhesion and clinical outcomes at 1 year similar to DP-DES. DCS can thus be used with similar safety and efficacy as DP-DES. Topics: Absorbable Implants; Angioscopy; Coronary Artery Disease; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Sirolimus; Stents; Treatment Outcome | 2021 |
Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes.
While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84-88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES).. In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)-cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions.. At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84-88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114-120um) Biomatrix Flex SS-BP-BES. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Anti-Inflammatory Agents; Chromium Alloys; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Registries; Sirolimus; Stainless Steel; Treatment Outcome | 2021 |
Real-world reasons and outcomes for 1-month versus longer dual antiplatelet therapy strategies with a polymer-free BIOLIMUS A9-coated stent.
A large trial established the favorable profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a 1-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. This is the first study comparing outcomes for a 1-month versus longer DAPT strategies following PF-BES-percutaneous coronary intervention (PCI).. All patients undergoing PF-BES-PCI (January 2016 to July 2018) were included in the multicenter CHANCE registry. Patients were stratified according to DAPT strategy at discharge (planned 1-month vs. planned >1-month). Primary outcomes were the 390-day estimates of a patient-oriented and of a device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularization; DOCE: cardiac death, target vessel-MI or ischemia-driven target lesion revascularization). Landmark analyses from 1-month post-PCI were carried.. Following PF-BES-PCI, 328(40.3%) and 485(59.6%) patients were discharged with 1-month and longer DAPT (12 months [6-12]), respectively. Patients with a previous or index MI were less likely to be discharged on 1-month DAPT. Patients prescribed with 1-month DAPT were more likely to be at HBR than those with longer DAPT (90.2% vs. 69.9%, p = .001). No between-groups differences in the primary outcomes (planned 1-month vs. planned >1-month DAPT: POCE 11.9% vs. 13.2%, p = .747; DOCE: 4.8% vs. 8.1%, p = .500) were observed, also after adjusting for confoundings (POCE: adjusted-hazard ratio [adj-HR] 1.26, 95%CI 0.74-2.13; DOCE: adj-HR 1.00, 95%CI 0.49-1.99). Landmark analyses showed similar results.. In a large all-comers registry of PF-BES PCI, no interaction of planned DAPT strategy (1-month vs. >1-month) with outcomes was found. This observation warrants investigation in adequately powered randomized studies (ClinicalTrials.gov NCT03622203). Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Drug Administration Schedule; Drug-Eluting Stents; Dual Anti-Platelet Therapy; Female; Humans; Italy; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Registries; Sirolimus; Time Factors; Treatment Outcome | 2020 |
Dual antiplatelet therapy strategies and clinical outcomes in patients treated with polymer-free biolimus A9-coated stents.
A large trial established the favourable clinical profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a one-month dual antiplatelet therapy (DAPT) regimen in patients at high bleeding risk (HBR). We aimed to evaluate the real-world patterns of indications, DAPT strategies and outcomes for the PF-BES following this evidence.. CHANCE is a multicentre registry including all patients who underwent percutaneous coronary intervention (PCI) with at least one PF-BES. The reasons for the PF-BES PCI and planned antithrombotic regimens were collected. Primary outcomes were the 390-day Kaplan-Meier estimates of patient-oriented and device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularisation [TVR]; DOCE: cardiac death, target vessel MI or ischaemia-driven target lesion revascularisation [ID-TLR]). Between January 2016 and July 2018, 858 patients (age 74±10 years, 64.6% male, 58.7% acute coronary syndrome presentation) underwent PF-BES PCI. The main reasons for the physicians' choice of PF-BES reflected a perceived HBR in 77.7% of patients. One-month DAPT was planned in 40.3% of patients. At 390-day follow-up (median 340 days, interquartile range: 187-390 days), the estimated incidence of POCE was 13.1% (any MI 3.7%, any TVR 3.4%) and of DOCE was 7.1% (TV-MI 3.6%, ID-TLR 1.4%), while the 390-day estimate of any bleeding event was 11.1% (BARC 3-5 bleeding 3.0%).. In a large all-comers registry, PF-BES was used mostly in HBR patients, frequently followed by a very short DAPT regimen. The reported outcomes suggest a favourable safety and efficacy profile for the PF-BES in a real-world clinical setting. ClinicalTrials.gov identifier: NCT03622203. Topics: Aged; Aged, 80 and over; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Polymers; Sirolimus; Treatment Outcome | 2020 |
Safety and efficacy of polymer-free biolimus-eluting stents versus ultrathin stents in unprotected left main or coronary bifurcation: A propensity score analysis from the RAIN and CHANCE registries.
Evaluate safety and efficacy of polymer-free biolimus-eluting stents (PF-BESs) versus ultrathin stents in unprotected left main (ULM) or bifurcation.. PF-BESs due to reduced length of dual antiplatelet therapy (DAPT) are increasingly used. However, there are limited data about safety and efficacy for ULM or bifurcation.. We selected all-patients treated for ULM or bifurcation from two multicenter real life registries (RAIN [NCT03544294] evaluating ultrathin stents, CHANCE [NCT03622203] appraising PF-BES). After propensity score with matching, the primary endpoint was major adverse cardiac events (MACE; a composite of all-cause death, myocardial infarction, target lesion revascularization [TLR], and stent thrombosis [ST]), while its components along with target vessel revascularization (TVR) secondary endpoints.. Three thousand and three patients treated with ultrathin stents and 446 with PF-BESs, resulting respectively in 562 and 281 after propensity score with matching (33 and 22%, respectively, with ULM disease). After 12 (8-20) months, rates of MACE were similar (9 vs. 8%, p = 0.56) without difference in TLR and ST (3.0 vs. 1.7%, p = .19 and 1.8 vs. 1.1%, p = .42). These results were consistent for ULM group (3 vs. 1.7% and 1.8 vs. 1.1%, p = .49 and .76), for non-ULM group (2.1 vs. 3.4%, p = .56 and 1.2 vs. 1.7%, p = .78) and for two-stent strategy (8.7 vs. 4.5% and 4.3 vs. 3.2%, p = .75 and .91). Among patients treated with 1 month of DAPT in both groups, those with ultrathin stents experienced higher rates of MACE related to all-cause death (22 vs. 12%, p = .04) with higher although not significant rates of ST (3 vs. 0%, p = .45).. PF-BES implanted on ULM or BiF offered freedom from TLR and ST comparable to ultrathin stents. PF-BESs patients assuming DAPT for 1 month experienced a lower despite not significant incidence of ST. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Clinical Protocols; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Propensity Score; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors | 2020 |
Impact of Insulin-Treated and Noninsulin-Treated Diabetes Mellitus in All-Comer Patients Undergoing Percutaneous Coronary Interventions With Polymer-Free Biolimus-Eluting Stent (from the RUDI-FREE Registry).
Patients with diabetes mellitus (DM) have worse outcomes after percutaneous coronary intervention (PCI). Recent evidences suggest a differential impact of insulin-treated and noninsulin-treated DM on prognosis. We evaluated the clinical outcome of diabetic patients after PCI with polymer-free biolimus-eluting stent from the RUDI-FREE Registry, investigating a possible different prognostic impact of insulin-treated and noninsulin-treated DM. A total of 1,104 consecutive patients who underwent PCI with polymer-free biolimus-eluting stent, enrolled in the RUDI-FREE observational, multicenter, single-arm registry, were stratified by diabetic status; diabetic population was further divided on the basis of insulin treatment. Primary end points of the study were target lesion failure (TLF; composite of cardiac death, target vessel myocardial infarction, target lesion revascularization) and major adverse cardiac and cerebrovascular events (composite of cardiac death, stroke, and myocardial infarction). Multiple ischemic adverse events were also single-handedly considered as secondary end points. At 1 year, TLF was significantly higher in the diabetic cohort, as compared with nondiabetic patients (6.0% vs 3.1%, p 0.022). None of the end points resulted significantly different between nondiabetics and noninsulin-treated diabetic patients. Divergently, compared with nondiabetic, insulin-treated diabetic patients faced significant higher rates of TLF (10.8% vs 3.1%, p 0.003), major adverse cardiac and cerebrovascular events (10.8% vs 3.4%, p 0.004), and of most of the analyzed adverse events. In conclusion, patients with DM had a higher risk of TLF compared with nondiabetics; nonetheless, the worse outcome of the diabetic population seems to be driven by the insulin-treated diabetic subpopulation. This finding suggests a different risk profile of insulin-treated and noninsulin-treated diabetic patients in the modern era of PCI. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Hypoglycemic Agents; Immunosuppressive Agents; Insulin; Male; Percutaneous Coronary Intervention; Polymers; Prognosis; Prospective Studies; Prosthesis Design; Registries; Sirolimus | 2019 |
Application of the MADS classification system in a "mega mammoth" stent trial: Feasibility and preliminary clinical implications.
We attempted to test the feasibility of application of the MADS classification system in the largest stent trial to date and evaluate the preliminary clinical implications of this approach.. In the randomized GLOBAL LEADERS trial, testing two different antiplatelet strategies in patients undergoing PCI with bivalirudin and biolimus-eluting stents, the e-CRF was dedicated to bifurcation treatment according to the MADS classification. Based on this e-CRF, the techniques used for bifurcations treatment in GLOBAL LEADERS were described and compared with two large, all-comer registries of bifurcations treatment (I-BIGIS and COBIS), used as historical controls.. Among 15,991 patients enrolled in the trial, 22,921 lesions treated at the index and staged procedure were available for analysis and 2,757 of these lesions were bifurcations and 7 were trifurcation lesions. The e-CRF-based MADS classification was achieved in 2,757 of these lesions (100%). 80.3% of bifurcations were treated using a single stent, 18.9% using 2 stents and 0.7% using 3 stents. Overall, the "main across side first" approach (A) was used in 77.4% with the "side branch first" approach (S) being the second most frequently used technique (10.2%). A single stent was used in the majority of the "A" approach (87.9%). A reduction in the use of 2-stent techniques (from 33.9 to 18.9%) was observed between GLOBAL LEADERS and I-BIGIS. The "A" approach was the most frequently used technique in GLOBAL LEADERS, while in COBIS the "S" strategy was most frequently employed.. Application of the MADS classification through an e-CRF was feasible in the largest stent trial today and provided useful information about the trends observed overtime in the treatment of bifurcation lesions. Topics: Antithrombins; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Feasibility Studies; Hirudins; Humans; Peptide Fragments; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prosthesis Design; Randomized Controlled Trials as Topic; Recombinant Proteins; Sirolimus; Terminology as Topic; Treatment Outcome | 2019 |
Safety and Efficacy of Polymer-Free Drug-Eluting Stents.
Background Polymer-free drug-eluting stents are based on different technologies for drug binding and release without the use of polymer coatings. It is unknown whether different polymer-free drug-eluting stents are comparable in terms of safety and efficacy profiles. Methods and Results Polymer-free BioFreedom biolimus-eluting stents (BES) and polymer-free Cre8 amphilimus-eluting stents (AES) were investigated in 2 recent multicenter registries including 2320 all-comer patients undergoing percutaneous coronary interventions at 22 Italian centers. Using propensity score matching, safety and efficacy outcomes were compared among 1280 patients (640 matched pairs) treated with BioFreedom BES or Cre8 AES. The primary end point was target lesion failure-a composite of cardiac death, target vessel myocardial infarction, and target lesion revascularization (TLR). At 1 year, target lesion failure occurred in 4.0% of BES and 4.2% of AES-treated patients (hazard ratio [HR] 0.98, 95% CI, 0.57-1.70). Risks of cardiac death (2.0% versus 2.1%; HR, 1.03; 95% CI, 0.47-2.26), target vessel myocardial infarction (0.8% versus 0.3%; HR, 1.89; 95% CI, 0.50-6.80), TLR (1.5% versus 2.2%; HR, 0.74; 95% CI, 0.34-1.62), and definite/probable stent thrombosis (0.9% versus 0.8%; HR, 1.17; 95% CI, 0.36-3.81) were comparable in patients treated with BioFreedom BES and Cre8 AES. A differential treatment effect by diabetes mellitus status was observed, indicating a benefit of AES in patients with diabetes mellitus ( P interaction=0.003). Conclusions The present study shows that BioFreedom BES and Cre8 AES have favorable and comparable safety and efficacy profiles in all-comer patients undergoing percutaneous coronary intervention. Further evaluation in large-scale, randomized trials are necessary to confirm our findings. Topics: Aged; Coronary Artery Disease; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Italy; Male; Middle Aged; Observational Studies as Topic; Percutaneous Coronary Intervention; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
One-year clinical outcomes between biodegradable-polymer-coated biolimus-eluting stent and durable-polymer-coated drug-eluting stents in STEMI patients with multivessel coronary artery disease undergoing culprit-only or multivessel PCI.
There are limited data comparing clinical outcomes among new-generation drug-eluting stents (DES) in ST-segment elevation myocardial infarction (STEMI) patients with multivessel coronary artery disease (MVD) who underwent primary percutaneous coronary intervention (PCI) with culprit-only or multivessel PCI. We investigated 1-year clinical outcomes between biodegradable-polymer (BP)-coated biolimus-eluting stent (BES) and durable-polymer (DP)-coated DES in STEMI patients with MVD who underwent two different reperfusion strategies.. A total of 4255 patients were enrolled and divided into two groups, a culprit-only (n = 2571, BP- [n = 264] or DP-DES [n = 2307]) or a multivessel PCI group (n = 1684, BP- [n = 145] or DP-DES [n = 1539]). The primary endpoint was major adverse cardiac events (MACE) defined as all-cause death, recurrent myocardial infarction (re-MI), and total repeat revascularization. The secondary endpoint was the incidence of definite or probable stent thrombosis (ST).. BP-BES and DP-DES showed a similar 1-year adjusted hazard ratio (HR) for MACE (culprit-only, adjusted hazard ratio [HR], 1.114; p = 0.740; multivessel, HR, 0.564; p = 0.167) and ST (culprit-only, HR, 1.110, p = 0.891; multivessel, HR, 0.375; p = 0.402). The adjusted HR for all-cause death, re-MI, and repeat revascularization were similar between the two groups. In the total population, the culprit-only PCI group showed a higher incidence of total repeat revascularization than the multivessel PCI group.. BP-BES and DP-DES showed comparable safety and efficacy in STEMI patients with MVD who underwent primary PCI with two different reperfusion strategies during a 1-year follow-up period. Topics: Aged; Coated Materials, Biocompatible; Cohort Studies; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Retrospective Studies; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2019 |
Comparative Effectiveness and Safety of Polymer-Free Biolimus-Eluting Stent and Durable Polymer Everolimus-Eluting Stent in All-Comer Patients Who Underwent Percutaneous Coronary Interventions.
We aim to compare Polymer-Free Biolimus-Eluting Stent (PF-BES) with Durable Polymer Everolimus-Eluting stent (DP-EES) in unselected patients. PF-BES showed a favorable profile in high-bleeding risk patients who underwent percutaneous coronary intervention. Limited data are available on PF-BES compared with second-generation durable polymer-coated drug-eluting stents in patients eligible for standard dual antiplatelet therapy. A total of 848 consecutive patients were enrolled: 306 patients were treated with PF-BES and 542 with DP-EES. Stent performance was tested in a propensity score-matched population and in a Complex Higher-Risk and Indicated Patients (CHIP) subpopulation. A per-lesion analysis on 1,204 lesions (PF-BES = 424 vs DP-EES = 780) was also performed. At a medium follow-up of 18.5 ± 5.0 months, no differences in the matched population were found in terms of major adverse cardiac events (PF-BES 9.0% vs DP-EES 4.5%; p 0.091), myocardial infarction (PF-BES 6.2% vs DP-EES 2.3%; p 0.111), stent restenosis (PF-BES 2.3% vs DP-EES 0.0%; p 0.123), definite or probable stent thrombosis (PF-BES 2.8% vs DP-EES 1.1%; p 0.448). A significant inferior rate of restenosis was observed in the DP-EES arm in the whole (PF-BES 2.3% vs DP-EES 0.6%; p 0.041) and CHIP populations (PF-BES 4.3% vs DP-EES 0.5%; p 0.023), as well as in the per-lesion analysis (DP-EES 0.4% vs PF-BES 1.7%; p 0.039). In conclusion, in a real-world cohort PF-BES performed similarly to DP-EES in terms of restenosis and stent thrombosis in the matched population. Nonetheless, in the whole and CHIP populations, as well as in the per-lesion analysis, restenosis occurrence resulted higher in the PF-BES group. Topics: Absorbable Implants; Aged; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Treatment Outcome | 2019 |
Impact of Diabetes on Clinical Outcomes After Polymer-Free Amphilimus- and Biolimus-Eluting Stent Implantation.
Topics: Cardiovascular Agents; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Humans; Italy; Percutaneous Coronary Intervention; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Angiographic and clinical performance of polymer-free biolimus-eluting stent in patients with ST-segment elevation acute myocardial infarction in a metropolitan public hospital: The BESAMI MUCHO study.
This study aimed at assessing the performance of a new generation polymer-free biolimus-eluting stent (BES) in real-world patients with ST-segment elevation myocardial infarction (STEMI).. Polymers components of early-generation drug-eluting stents have been implicated in the pathogenesis of delayed arterial healing, vessel remodeling, and delayed stent thrombosis. Recently, a novel polymer-free BES has shown excellent clinical performance in clinical trial setting.. Overall, 175 consecutive patients (64 ± 14 years, 141 men) treated with the BioFreedom (Biosensors Europe, Morges, Switzerland) polymer-free BES because of STEMI were included in this study. The primary endpoint was the rate of major adverse cardiac events (MACE), a composite of cardiac death, recurrent myocardial infarction, and ischemia-driven target vessel revascularization at 1 year follow-up. A subgroup of patients underwent 6-month angiographic follow-up. Dual antiplatelet therapy was prescribed for 12 months after STEMI.. At 1 year, the cumulative rate of MACE was 4.6%. One patient (0.6%) had an arrhythmic cardiac death and five (2.9%) had ischemia-driven target vessel revascularization, although only three (1.7%) had target lesion revascularization. Two (1.1%) patients had acute stent thrombosis yielding nonfatal myocardial infarction. In 70 patients (63 ± 14 years, 61 men), quantitative coronary angiography at 6-month follow-up revealed diameter stenosis of 24.1 ± 13.7% and minimal lumen diameter of 2.29 ± 0.56 mm, yielding a late lumen loss of 0.13 ± 0.14 mm.. In real-world setting, implantation of a new-generation polymer-free BES during STEMI is associated with favorable clinical and angiographic results, pointing toward the overall efficacy and safety of the device in complex clinical scenarios. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Hospitals, Public; Hospitals, Urban; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Recurrence; Registries; Risk Factors; Rome; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2018 |
Efficacy of biolimus A9-eluting stent for treatment of right coronary ostial lesion with intravascular ultrasound guidance: a multi-center registry.
The aim of this study was to assess the efficacy of a biolimus A9-eluting stent in patients with a right coronary artery (RCA) ostial lesion. Ostial lesions of the RCA have been a limitation of percutaneous coronary intervention even in the drug-eluting stent (DES) era. However, clinical outcomes after the deployment of a second generation DES to an RCA ostial lesion with intravascular ultrasound (IVUS) guidance have not been fully elucidated. From September 2011 to March 2013, 74 patients were enrolled in 17 centers from Japan. RCA ostial lesion was defined as de novo significant stenotic lesion located within 15 mm from ostium. IVUS was used for all cases to confirm the location of ostium and evaluate stent coverage of ostium. Patients with hemodialysis were excluded. The primary endpoint is a major adverse cardiac event (MACE) at 1 year. Forty two percent of patients had multi-vessel disease. Angiographically severe calcification was observed in 26% of the lesions. The mean stent diameter was 3.3 ± 0.3 mm (3.5 mm, 72%, 3.0 mm, 25%, and 2.75 and 2.5 mm, 3%), stent length was 17.5 ± 5.8 mm, and dilatation pressure of stenting was 15.6 ± 4.1 atm. RCA ostium was covered by stent in all lesions in IVUS findings. Post dilatation was performed for 64% of lesions (balloon size 3.7 ± 0.6 mm). MACE rate at 1 year was 5.4% (target lesion revascularization 5.4%, myocardial infarction 1.2%, and no cardiac death). The biolimus A9-eluting stent for RCA ostial lesions with IVUS guidance showed favorable results at 1-year follow-up. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Japan; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Registries; Sirolimus; Treatment Outcome; Ultrasonography, Interventional | 2018 |
Effectiveness and Safety of Biolimus A9™-Eluting stEnt in Patients with AcUTe Coronary sYndrome; A Multicenter, Observational Study (BEAUTY Study).
This study sought to determine the 1-year clinical effectiveness and safety of a biodegradable, polymer-containing Biolimus A9™-eluting stent (BES) in Korean patients with acute coronary syndrome (ACS).. A total of 1000 ACS patients with 1251 lesions who underwent implantation of BESs at 22 centers in Korea were enrolled between May 2011 and July 2013. We assessed major adverse cardiac events (MACE) defined as the composite of cardiac death, non-fatal myocardial infarction (MI), and clinical-driven target vessel revascularization at 12 months.. Patient mean age was 62.6±11.4 years. 72.8% of the patients were male, 28.5% had diabetes, 32.8% had multi-vessel disease (MVD), and 47.9% presented with acute MI (AMI). The mean global registry of acute coronary events risk score of all patients was 103.0±27.6. The number of stents per patient was 1.3±0.6. The incidences of MACE and definite stent thrombosis at 12 months were 3.9% and 0.2%, respectively. On multivariate Cox-regression analysis, age ≥65 years was identified as an independent predictors of 1-year MACE (hazard ratio=2.474; 95% confidence interval=1.202-5.091). Subgroup analyses revealed no significant differences in the incidence of MACE between patients with and without diabetes (4.3% vs. 3.7%, p=0.667), between those who presented with and without AMI (4.4% vs. 3.4%, p=0.403), and between those with and without MVD (4.6% vs. 3.5%, p=0.387).. Our study demonstrated excellent 1-year clinical outcomes of BES implantation in patients at low-risk for ACS. Topics: Acute Coronary Syndrome; Aged; Drug-Eluting Stents; Female; Humans; Incidence; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Proportional Hazards Models; Republic of Korea; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Effects of Coronary Artery Revascularization with a Polymer-Free Biolimus A9-Coated BioFreedom Stent Versus Bypass Surgery before Noncardiac Surgery.
The present study aimed to evaluate the efficacy and safety of polymer-free drug-coated BioFreedom stent implantation in comparison to coronary artery bypass graft (CABG) before major noncardiac surgery.. In a multicenter registry, 55 patients required revascularization before major noncardiac surgery that should not be delayed >6 months. Of them, 27 underwent BioFreedom stent implantation and 28 underwent CABG. Primary outcomes included rate of noncardiac surgery, time from revascularization to noncardiac surgery, and occurrence of composite outcomes (all-cause death, myocardial infarction, stent thrombosis, stroke, repeat revascularization, or major bleeding).. The rate of major noncardiac surgery was significantly higher in the BioFreedom group (92.6%) than in the CABG group (64.3%; p=0.027). Time from revascularization to noncardiac surgery was significantly shorter in the BioFreedom group (38.0 days) than in the CABG group (73.0 days; p=0.042). During the hospitalization for revascularization period, the occurrence of primary outcomes did not differ between the groups. However, the BioFreedom group showed a shorter hospitalization period and lower total treatment cost than the CABG group. During the hospital stay for noncardiac surgery, the occurrence of composite outcome was not significantly different between groups (4% vs. 0%; p>0.999): stroke occurred in only 1 case, and there were no cases of death or stent thrombosis in the BioFreedom group.. This study demonstrated that BioFreedom stenting as a revascularization strategy before major noncardiac surgery might be feasible and safe in selected patients with less severe coronary artery diseases. Topics: Aged; Coronary Artery Bypass; Coronary Artery Disease; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Myocardial Infarction; Sirolimus; Stroke; Treatment Outcome | 2018 |
Twelve-month outcomes of patients unsuitable for prolonged DAPT presenting with an acute coronary syndrome and treated with polymer-free biolimus A9 drug-coated stents.
Prolonged dual anti-platelet therapy (DAPT) is undesirable in certain patients. The biolimus-A9 drug-coated stent (BA9-DCS) has a rapid drug-elution profile allowing shortened DAPT.. The demographics, procedural data, and clinical outcomes for 505 patients presenting with an ACS to three UK centres and treated with a BA9-DCS stent (PCI-DCS) were collected, and compared to a consecutive ACS cohort of unselected patients treated in the same period with drug-eluting stents (PCI-DES).. PCI-DCS patients were older, more often female with hypertension, chronic kidney disease, severe LV dysfunction, and peripheral vascular disease more frequent than the PCI-DES cohort. PCI-DCS patients had a much higher Mehran bleed risk score (21.5 ± 7.7 vs. 15.9 ± 7.7, P < 0.0001). Baseline disease burden was greater in the PCI-DCS cohort with more left main and three vessel disease. During PCI, more stents (1.91 ± 1.1 vs. 1.57 ± 0.94, P < 0.0001), total stent length (38.2 ± 20.8 vs. 31.4 ± 20.3, P < 0.0001) and longer stents (38.2 ± 20.8 vs. 31.4 ± 20.3 mm, P < 0.0001) were used in the PCI-DCS cohort with rotational atherectomy also used more frequently. Physician-recommended DAPT duration was 2.9 ± 3.9 months for PCI-DCS patients and 11.3 ± 2.4 months for PCI-DES patients (P < 0.0001). At 12-month follow-up, definite stent thrombosis (0.6% vs. 1.1%) and TLR (3.2% vs. 2.7%) rates were similar between the two groups. After adjustment for baseline differences, there were no statistically significant differences in death and combined MACE rates at 12 months.. The outcomes of patients treated with polymer-free BA9 drug-coated stent who present with an ACS and who were deemed unsuitable for prolonged DAPT are encouraging. Further studies are warranted. Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Preliminary Data; Prosthesis Design; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; United Kingdom | 2018 |
Mid-term outcome of biolimus-eluting stents with biodegradable polymer: results from a multinational prospective 'all-comers' registry.
The Nobori biolimus-eluting stent (BES) is a biodegradable polymer drug-eluting stent (DES). Several studies have shown its noninferiority in comparison with durable polymer DES.. We sought to investigate the efficacy and the safety of Nobori BES in an all-comer population undergoing a percutaneous coronary intervention.. A total of 12 912 patients with 19 947 coronary lesions, undergoing percutaneous coronary intervention with Nobori BES implantation at 200 centres around the world between August 2010 and December 2015, were included in this prospective registry. Patients were stratified into four groups according to the total stent length, with cutoffs at 18, 24 and 28 mm. The primary endpoint was the occurrence of major adverse cardiac events defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularization at 1 year.. At 1 year, the major adverse cardiac events rate was the highest (4.6%) in the fourth quartile of stent length (>28 mm), whereas the overall rate of the primary endpoint in the all cohort was 3.5%. Both target lesion revascularization and target vessel revascularization rates were significantly higher in patients with longer stent length was implanted (all P<0.05). The incidence of definite and probable stent thrombosis at 1 year was 0.5% in all cohort and similar across the four groups (varying from 0.4 to 0.7%, all P=NS).. Our data confirmed the efficacy and the safety of the Nobori BES in routine clinical practice. Longer stent length is associated with a higher risk of adverse cardiac events, and yet, this risk is comparable with that of other DES. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Abluminal-Coated Drug-Eluting Bifurcation-Dedicated Stent for the Treatment of Tibioperoneal Bifurcation.
Endovascular treatment of below-the-knee region disease is often challenging because of the involvement of arterial bifurcations. Several cases have been reported on the use of coronary stents for the treatment of these patients, but limited evidence is available on the use of dedicated coronary bifurcation devices. We here report the endovascular treatment of a symptomatic bifurcation lesion in below-the-knee region, using a self-expanding Biolimus A9-eluting stent in combination with a "conventional" coronary drug-eluting stent. Topics: Angiography; Angioplasty, Balloon; Cardiovascular Agents; Drug-Eluting Stents; Humans; Leg; Male; Middle Aged; Peripheral Arterial Disease; Prosthesis Design; Radiography, Interventional; Sirolimus; Tibial Arteries; Treatment Outcome | 2017 |
Early endothelialization associated with a biolimus A9 bioresorbable polymer stent in a porcine coronary model.
Although Nobori Topics: Absorbable Implants; Animals; Aspirin; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Endothelium, Vascular; Humans; Metals; Platelet Aggregation Inhibitors; Prosthesis Design; Sirolimus; Swine | 2017 |
Long-term Safety and Efficacy of New-Generation Drug-Eluting Stents in Women With Acute Myocardial Infarction: From the Women in Innovation and Drug-Eluting Stents (WIN-DES) Collaboration.
Women with acute myocardial infarction (MI) undergoing mechanical reperfusion remain at increased risk of adverse cardiac events and mortality compared with their male counterparts. Whether the benefits of new-generation drug-eluting stents (DES) are preserved in women with acute MI remains unclear.. To investigate the long-term safety and efficacy of new-generation DES vs early-generation DES in women with acute MI.. Collaborative, international, individual patient-level data of women enrolled in 26 randomized clinical trials of DES were analyzed between July and December 2016. Only women presenting with an acute coronary syndrome were included. Study population was categorized according to presentation with unstable angina (UA) vs acute MI. Acute MI included non-ST-segment elevation MI (NSTEMI) or ST-segment elevation MI (STEMI).. Randomization to early- (sirolimus- or paclitaxel-eluting stents) vs new-generation (everolimus-, zotarolimus-, or biolimus-eluting stents) DES.. Composite of death, MI or target lesion revascularization, and definite or probable stent thrombosis at 3-year follow-up.. Overall, the mean age of participants was 66.8 years. Of 11 577 women included in the pooled data set, 4373 (37.8%) had an acute coronary syndrome as clinical presentation. Of these 4373 women, 2176 (49.8%) presented with an acute MI. In women with acute MI, new-generation DES were associated with lower risk of death, MI or target lesion revascularization (14.9% vs 18.4%; absolute risk difference, -3.5%; number needed to treat [NNT], 29; adjusted hazard ratio, 0.78; 95% CI, 0.61-0.99), and definite or probable stent thrombosis (1.4% vs 4.0%; absolute risk difference, -2.6%; NNT, 46; adjusted hazard ratio, 0.36; 95% CI, 0.19-0.69) without evidence of interaction for both end points compared with women without acute MI (P for interaction = .59 and P for interaction = .31, respectively). A graded absolute benefit with use of new-generation DES was observed in the transition from UA, to NSTEMI, and to STEMI (for death, MI, or target lesion revascularization: UA, -0.5% [NNT, 222]; NSTEMI, -3.1% [NNT, 33]; STEMI, -4.0% [NNT, 25] and for definite or probable ST: UA, -0.4% [NNT, 278]; NSTEMI, -2.2% [NNT, 46]; STEMI, -4.0% [NNT, 25]).. New-generation DES are associated with consistent and durable benefits over 3 years in women presenting with acute MI. The magnitude of these benefits appeared to be greater per increase in severity of acute coronary syndrome. Topics: Acute Coronary Syndrome; Aged; Angina, Unstable; Antineoplastic Agents, Phytogenic; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Middle Aged; Mortality; Myocardial Infarction; Myocardial Revascularization; Non-ST Elevated Myocardial Infarction; Paclitaxel; Percutaneous Coronary Intervention; Proportional Hazards Models; Randomized Controlled Trials as Topic; Recurrence; Sirolimus; ST Elevation Myocardial Infarction; Treatment Outcome | 2017 |
Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents.
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 patients treated with BP-BES and 1,000 patients treated with DP-EES. The primary outcome was target lesion failure, defined as a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization. Definite or probable stent thrombosis was also compared in total and propensity score-matched cohorts. The median follow-up duration was 24 months, and mean age was 65 years (interquartile range, 56-72 years). Patients receiving BP-BES had a lower prevalence of acute coronary syndrome, prior myocardial infarction, multi-vessel disease, bifurcation lesions, and left anterior descending artery lesions than those receiving DP-EES. After propensity score matching (692 pairs), target lesion failure occurred in 22 patients receiving BP-BES and in 25 patients receiving DP-EES (3.2% versus 3.6%; adjusted hazard ratio [HR], 0.92; 95% confidence interval [CI], 0.53 to 1.60; p = 0.77). The risk of definite or probable stent thrombosis did not differ between the 2 groups (0.4% versus 0.4%; adjusted HR, 1.03; 95% CI, 0.21 to 4.98; p = 0.97). The results were consistent across various subgroups. In the propensity score-matched analysis of real world cohorts, BP-BES showed similar clinical outcomes compared to DP-EES. We need to investigate about whether differences in clinical outcome emerge during long-term follow-up. Topics: Absorbable Implants; Aged; Coated Materials, Biocompatible; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Propensity Score; Proportional Hazards Models; Prospective Studies; Sirolimus; Thrombosis; Treatment Outcome | 2017 |
Percutaneous Coronary Interventions in Patients Requiring Long-Term Oral Anticoagulation: Is the Drug-Coated Stent a Potential Game Changer?
Topics: Anticoagulants; Drug-Eluting Stents; Humans; Metals; Percutaneous Coronary Intervention; Polymers; Sirolimus; Stents | 2017 |
Polymer-free amphilimus-eluting stent versus biodegradable polymer biolimus-eluting stent in patients with and without diabetes mellitus.
This study sought to compare clinical outcome of polymer-free amphilimus-eluting stent (PF-AES) versus biodegradable-polymer biolimus-eluting stent (BD-BES) in "all-comer" diabetes mellitus (DM) and non-DM patients who underwent percutaneous coronary intervention.. The PF-AES has shown promising preliminary results in patients with DM.. Data from 2 multicentre-national registries (the ASTUTE and the INSPIRE-1) were used to analyse 1776 patients stratified in non-DM and DM. A double 1:1 propensity-score matched analysis (PF-AES vs. BD-BES) was performed in each group to adjust for clinical and procedural characteristics. Primary stent-efficacy and stent-safety endpoints were 1-year target-lesion revascularization (TLR) and target-lesion failure (TLF, composed of cardiac-death, target-vessel myocardial infarction and any TLR).. This matched-cohort study suggests that PF-AES has better safety and efficacy profile than BD-BES in patients with DM. Topics: Absorbable Implants; Aged; Anti-Inflammatory Agents; Cohort Studies; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Registries; Sirolimus | 2017 |
Five-year clinical performance of a biodegradable polymer-coated biolimus-eluting stent in unselected patients.
To evaluate the long-term follow-up of the unrestricted use of a biodegradable polymer-coated drug-eluting stent in patients undergoing percutaneous coronary intervention (PCI).. The Nobori 2 study was a prospective, multicentre, observational registry evaluating the safety and the efficacy of the biodegradable polymer biolimus-eluting stent (BP-BES) among 3067 patients recruited at 125 international sites. The primary combined endpoint was a composite of cardiac death, myocardial infarction and target-lesion revascularisation (TLR).. Five-year follow-up was available in 2738 (89.3%) patients. The combined endpoint occurred in 268 patients (10%, 95% CIs 8.9% to 11.3%) at 5 years, with 3.9% of events during the first year and 6.2% during years 1-5 of follow-up. Cumulative rates of TLR and definite/probable stent thrombosis were 5.3% (95% CI 4.5% to 6.3%) and 1.1% (95% CI 0.8% to 1.6%), respectively. Between 1 and 5 years, TLR and very late stent thrombosis rates were 3.5% (95% CI 2.8% to 4.4%) and 0.6% (95% CI 0.3% to 1.1%), respectively. Previous PCI (HR, 2.05, 95% CI 1.68 to 2.50), moderate-to-severe renal disease (HR, 1.89, 95% CI 1.30 to 2.74) and peripheral vascular disease (HR, 1.86, 95% CI 1.38 to 2.52) were the three most powerful independent predictors of the combined endpoint at 5 years.. The final 5-year follow-up of the Nobori 2 registry demonstrates the safety and effectiveness of the BP-BES in an unselected, broadly inclusive cohort of PCI patients, highlighting the excellent performance of this coronary stent technology after polymer biodegradation.. ISRCTN81649913; Results. Topics: Absorbable Implants; Aged; Coronary Thrombosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Kaplan-Meier Estimate; Kidney Diseases; Male; Middle Aged; Percutaneous Coronary Intervention; Peripheral Vascular Diseases; Polymers; Prospective Studies; Prosthesis Design; Registries; Retreatment; Sirolimus; Treatment Outcome | 2017 |
Comparative Case-Control analysis of a dedicated self-expanding Biolimus A9-eluting Bifurcation stent versus provisional or mandatory side branch intervention strategies in the treatment of coronary bifurcation lesions.
In a number of coronary bifurcation lesions, both the main vessel and the side branch (SB) need stent coverage.. To analyze the procedural performance and the impact on radiation times (RT) and contrast medium consumption (CMC) of the Axxess™ stent system (Biosensors, Switzerland) treating de novo bifurcation lesions (DBL).. One hundred and ten consecutive prospectively enrolled cases (Axxess Group) and 110 age, sex, and lesion location matched controls undergoing mandatory (Group A, n = 56) or provisional (Group B, n = 54) SB intervention were analyzed.. Although more pre-dilatation was performed in the Axxess Group (92.7% vs. 46.4% [Group A] vs. 24.1% [Group B]), and more stents were used (2.4 vs. 1.2 vs. 1.05), RT and CMC were significantly lower in the Axxess Group [7.9 min/129 ml vs. 14.2 min/209 ml vs. 7.8 min/152 ml; P < 0.001]. Final Thrombolysis In Myocardial Infarction three flow in both branches was significantly more frequent in the Axxess Group (98.2% vs. 94.6% vs. 88.9%; P = 0.02), and post-interventional troponin T elevations were the lowest in the Axxess Group. Eighty one percent of the Axxess-stents could be implanted without technical difficulties. Difficult implantations procedures were mainly related to coronary anatomy. There was no safety concerns (cardiac death, stent-thrombosis) compared to controls. Cumulative 6-months MACE rates were 11% versus 23% versus 25%. TLR rates at 6-months were 5%, 18%, and 15%, respectively.. Axxess bifurcation stent system procedures were associated with significantly less RT and CMC compared to conventional DBL therapy strategies. Difficult coronary anatomy may hinder successful implantation and a learning curve has to be considered. © 2016 Wiley Periodicals, Inc. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Case-Control Studies; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Germany; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Radiation Dosage; Radiation Exposure; Radiography, Interventional; Registries; Risk Factors; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2017 |
Outcomes of Acute Myocardial Infarction Patients Implanted With Biodegradable Polymer Biolimus-Eluting Stents Versus New-Generation Durable Polymer Drug-Eluting Stents: A Retrospective Analysis.
We compared outcomes between biodegradable polymer biolimus-eluting stent (BP-BES) and new-generation durable polymer drug-eluting stent (DP-DES) implantations in patients with acute myocardial infarction (MI). Among 13472 patients with acute MI in a nationwide registry, 557 (64.8%) were in the BP-BES and 303 (35.2%) in the new-generation DP-DES group following coronary reperfusion. The occurrence of major adverse cardiac events (MACE; death, MI, revascularization) and stent thrombosis was compared. Major adverse cardiac events occurred in 53 (6.2%) patients and showed similar rates between the BP-BES and new-generation DP-DES groups (all: 6.6% vs 5.9%, P = .652; propensity score [PS] matched: n = 380, 6.3% vs 5.3%, P = .623). Stent thrombosis did not differ between groups (all: 0.3% vs 0.4%, P = .892; PS matched: 0.5% vs 0.5%, P = 1.000). Major adverse cardiac event-free survival was comparable between groups (all: 93.4% vs 94.1%, log-rank P = .357; PS matched: 93.7% vs 94.7%, log-rank P = .445). Biodegradable polymer biolimus-eluting stent was not associated with MACE (all: hazard ratio [HR], 1.67; 95% confidence interval [CI], 0.75-3.74; P = 0.212; PS matched: HR, 1.05; 95% CI, 0.40-2.75; P = .915). In conclusion, in patients with acute MI, BP-BES was equivalent to the new-generation DP-DES in terms of outcomes. Topics: Aged; Anti-Inflammatory Agents; Biocompatible Materials; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Propensity Score; Registries; Republic of Korea; Retrospective Studies; Sirolimus; Survival Rate; Treatment Outcome | 2017 |
Long-term (8-10 years) outcomes after biodegradable polymer-coated biolimus-eluting stent implantation.
Efficacy and safety data on biodegradable polymer-coated biolimus-eluting stent (BP-BES) are currently limited to 5 years. We evaluated longer term (8-10 years) clinical and angiographic outcomes after BP-BES implantation.. Between 2005 and 2008, 243 patients (301 lesions) underwent BP-BES implantation. The primary clinical outcome measure was defined as any target lesion revascularisation (TLR). Absolute serial angiographic studies without any concomitant TLR within 2 years after the procedure were performed in 55 patients (65 lesions) at postprocedure, mid-term (within 1 year), late term (between 1 and 2 years) and very late term (beyond 2 years).. The median follow-up duration was 9.4 years (IQR 8.2-10.2 years). The 8-year cumulative incidence of any TLR was 20.3%. The increase rate was approximately 7% per year in the first 2 years, but decelerated to approximately 1.2% per year beyond 2 years after the procedure. The minimal lumen diameter significantly decreased from postprocedure (2.63±0.44 mm) to mid-term (2.43±0.59 mm, p=0.002) and from late term (2.27±0.63 mm) to very late term (1.98±0.73 mm, p=0.002). The 8-year cumulative incidences of definite or probable stent thrombosis (ST) and major bleeding (Bleeding Academic Research Consortium (BARC) ≥3) were 0.5% and 12.0%, respectively. Definite ST was none within 10 years in the entire cohort.. The long-term clinical outcomes after BP-BES implantation were favourable, although angiographic late progression of luminal narrowing did not reach a plateau. The incidence of ST remained notably low, whereas that of major bleeding gradually increased. Topics: Absorbable Implants; Aged; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Female; Follow-Up Studies; Forecasting; Humans; Immunosuppressive Agents; Male; Myocardial Revascularization; Polymers; Prosthesis Design; Retrospective Studies; Sirolimus; Treatment Outcome | 2017 |
Comparison of Biolimus Versus Everolimus for Drug-Eluting Stents in the Percutaneous Treatment of Infra-Inguinal Arterial Disease.
Drug-eluting stents (DES) are now considered the most promising device to treat peripheral artery disease (PAD) and minimize restenosis. There is uncertainty however on the best antirestenotic drug for such devices. In particular, biolimus (i.e. umirolimus) and everolimus are two of the most promising agents, given the extensive data in support of their coronary safety and efficacy, but their comparative effectiveness for peripheral interventions is not established.. Building upon our extensive experience in the percutaneous treatment of infra-inguinal artery disease with DES, we compared the acute and longterm outlook of patients treated with biolimus-eluting stents (BES) and everolimus-eluting stents (EES). We collected baseline, procedural and outcome details on all patients undergoing infra-inguinal BES or EES implantation. The endpoints of interest were death, amputation, revascularization, their composite, and change in Fontaine class. A total of 80 patients were included (20 treated with BES and 60 with EES). Most features were similar in the two groups, despite longer lesions in the EES group. Unadjusted analysis showed similar results irrespective of the drug used, with composite endpoint occurring, respectively, in 4 (20.0%) and 10 (16.7%) (p=0.741).. However, analysis with inverse probability of treatment weighting showed significant differences in the risk of revascularization (hazard ratio of BES vs EES=9.55 [95% confidence interval 2.16-42.23], p=0.003) and composite endpoint (hazard ratio=5.11 [1.33-19.62], p=0.018). In conclusion, EES appear superior to BES for endovascular therapy of infrainguinal artery disease. Dedicated randomized trials are required to definitely confirm or disprove these findings. Topics: Aged; Aged, 80 and over; Amputation, Surgical; Cardiovascular Agents; Comparative Effectiveness Research; Drug-Eluting Stents; Endovascular Procedures; Everolimus; Female; Humans; Limb Salvage; Male; Middle Aged; Peripheral Arterial Disease; Prosthesis Design; Retrospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Abluminal biodegradable polymer-based Biolimus A9-eluting stent for the treatment of infrapopliteal arteries in critical limb ischemia: Long-term follow-up.
Topics: Aged; Aged, 80 and over; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Ischemia; Leg; Male; Middle Aged; Popliteal Artery; Radiography; Registries; Retrospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Two-year clinical outcomes of the NOBORI biolimus-eluting stents versus XIENCE/PROMUS everolimus-eluting stents in small vessel disease.
Biolimus-eluting stents (BES) have similar efficacy and safety compared with cobalt chromium everolimus-eluting stents (CoCr-EES), whereas it is unclear whether the same applies to small vessel disease. We sought compare clinical outcomes between BES and CoCr-EES in patients with small vessel disease.. A total of 1,132 patients treated only with BES (612 patients) or EES (520 patients) in small vessel disease (stent size 2.5-mm) were retrospectively analyzed. We assessed the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as a composite of cardiac death, myocardial infarction (MI), definite stent thrombosis (ST), and clinically driven target lesion revascularization (CD-TLR). The cumulative 2-year incidence of MACE was similar between the two groups (12.1% vs. 11.8%, P = 0.77). The cumulative incidence of cardiac death, CD-TLR, and definite ST were also not significantly different between both groups (3.2% vs. 3.6%, P = 0.78; 8.3% vs. 8.4%, P = 1.00; 0.33% vs. 0.21%, P = 0.66, respectively). After multivariate adjusting, the adjusted risk of BES group relative to CoCr-EES group for MACE was not significantly different (hazard ratio [HR]: 0.78, 95% confidential interval [CI]: 0.53-1.15, P = 0.20). Similarly, no significant difference in the adjusted risks for cardiac death and CD-TLR were observed between the two groups (HR: 0.62, 95% CI: 0.28-1.37, P = 0.24; HR: 0.81, 95% CI: 0.51-1.29, P = 0.38).. Two-year clinical outcomes of BES are similar to those of CoCr-EES in patients with small vessel disease. The use of BES is acceptable for small coronary artery disease. © 2015 Wiley Periodicals, Inc. Topics: Aged; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Incidence; Japan; Male; Percutaneous Coronary Intervention; Postoperative Complications; Retrospective Studies; Risk Factors; Sirolimus; Survival Rate; Time Factors | 2016 |
Optical coherence tomography-based assessment of bifurcation stenting using the Axxessª Biolimus A9ª-eluting stent system.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Predictive Value of Tests; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Differences of side branch jailing between left main-left anterior descending artery stenting and left main-left circumflex artery stenting with Nobori biolimus-eluting stent.
The aim of this study is to indicate differences of side branch jailing between the left main (LM)-left anterior descending artery (LAD) stenting and the LM-left circumflex artery (LCx) stenting. Thirty-one patients who underwent single-stenting using a two-link ten-crowns biolimus-eluting stent (Japanese design of BES, J-BES) and subsequent kissing balloon dilation (KBD) on an LM bifurcation with optical coherence tomography (OCT) were divided into two groups according to the stented vessel. Bifurcation angles were measured by three-dimensional (3D) quantitative coronary analysis. The jailing pattern on a side branch ostium was evaluated by stent-enhanced 3D-OCT. Incomplete stent apposition (ISA) after KBD was compared between the stented vessels. The to-be-stented angle of the LM-LCx stenting (n = 11) was significantly steeper than that of the LM-LAD stenting (n = 20) (132.6° ± 16.9° vs. 150.7° ± 10.6°, p < 0.01). The incidence of the free carina type, which has no stent links bridging from a carina, in the LM-LCx stenting was significantly higher than that in the LM-LAD stenting (90.9 vs. 45.0 %, p = 0.02). The percentage of ISA at the bifurcation segment in the LM-LCx stenting was significantly smaller than that in the LM-LAD stenting (4.4 ± 8.2 vs. 12.7 ± 9.2 %, p = 0.0003). This study showed, by higher incidence of the favorable configuration, that the LM-LCx stenting achieved a smaller percentage of ISA than the LM-LAD stenting. These insights may help guide LM bifurcation stenting with J-BES. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Imaging, Three-Dimensional; Japan; Male; Middle Aged; Prosthesis Design; Radiographic Image Interpretation, Computer-Assisted; Retrospective Studies; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Long-Term Clinical Outcomes of a Biodegradable Polymer-Based Biolimus-Eluting Stent.
To investigate the long-term clinical outcomes of biolimus-eluting stents with biodegradable polymers in real-world clinical practice.. Long-term clinical outcomes of biolimus-eluting stents have not been clearly established.. A total of 824 all-comer patients (971 lesions) treated with unrestricted implantation of a biolimus-eluting stent with a biodegradable polymer were prospectively enrolled. Patients were divided into complex (413 patients) versus noncomplex (411 patients) groups according to the complexity of coronary lesions. Long-term clinical outcomes for stent efficacy (target lesion revascularization) and safety (composite of cardiac death, target lesion-related myocardial infarction, and definite or probable stent thrombosis) were compared between the two groups during 5 years of follow-up.. The complex group showed higher rates of decreased left ventricular ejection fraction, impaired renal function, previous history of myocardial infarction, and diabetes mellitus compared to the noncomplex group. In the overall population, the 5-year cumulative rate of target lesion revascularization was 4.8% (8.3% in the complex group vs 1.6% in the noncomplex group, P < 0.001). For stent safety, the 5-year cumulative rate for a composite of cardiac death, target lesion-related myocardial infarction, and stent thrombosis was 2.5% overall (3.9% in the complex group vs 1.1% in the noncomplex group, P = 0.010). Overall 5-year cumulative rate of stent thrombosis was 0.4% (0.5% in the complex vs 0.2% in the noncomplex group, P = 0.561) with no very late stent thrombosis (VLST).. Biodegradable polymer-based biolimus-eluting stents showed favorable efficacy and safety in all-comer patients during 5 years of follow-up. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Polymers; Prospective Studies; Registries; Sirolimus; Treatment Outcome | 2016 |
Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.
We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent. Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Registries; Retrospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Unfavorable bioresorbable vascular scaffold resorption, a cause of restenosis?
We report a case of bioresorbable vascular scaffold restenosis which could be caused by abnormal resorption 17months after implantation. Topics: Absorbable Implants; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Male; Middle Aged; Non-ST Elevated Myocardial Infarction; Prosthesis Design; Retreatment; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Early Clinical Experience with a Polymer-Free Biolimus A9 Drug-Coated Stent in DES-Type Patients Who Are Poor Candidates for Prolonged Dual Anti-Platelet Therapy.
Prolonged dual anti-platelet therapy (DAPT) may cause excess bleeding in certain patients. The biolimus-A9 drug-coated stent (BA9-DCS) has a rapid drug-elution profile allowing shortened DAPT. Data were gathered on the early experience implanting this stent in drug-eluting stent eligible patients deemed to be at high risk of bleeding.. The demographics, procedural data and clinical outcomes were gathered prospectively for 249 patients treated with a BA9-DCS stent at 2 UK centres, and compared to a cohort of patients treated in the same period with drug-eluting stents (PCI-DES).. Operator-defined BA9-DCS indications included warfarin therapy, age, and anaemia. Patients receiving a BA9-DCS were older (71.6±11.8 vs. 64.8±11.6yrs, p<0.001), more often female (38.2 vs. 26.8%, P<0.001), and more likely to have comorbidity including chronic kidney disease or poor LV function than PCI-DES patients. The baseline Mehran bleed risk score was also significantly higher in the BA9-DCS group (19.4±8.7 vs. 13.1±5.8, p<0.001). Of the BA9-DCS cohort, 95.5% of patients demonstrated disease fitting NICE criteria for DES placement. The number of lesions treated (1.81±1.1 vs. 1.58±0.92, p = 0.003), total lesion length (32.1±21.7 vs. 26.1±17.6mm, p<0.001), number of stents used (1.93±1.11 vs. 1.65±1.4, p = 0.007) and total stent length (37.5±20.8 vs. 32.4±20.3, p<0.01) were greater for BA9-DCS patients. DAPT was prescribed for 3.3±3.9 months for BA9-DCS patients and 11.3±2.4 months for PCI-DES patients (p<0.001). At follow up of 392±124 days despite the abbreviated DAPT course stent related event were infrequent with ischemia-driven restenosis PCI (2.8 vs. 3.4%, p = 0.838), and stent thrombosis (1.6 vs. 2.1%, p = 0.265) rates similar between the BA9-DCS ad PCI-DES groups. After propensity scoring all clinical end-points were similar between both cohorts.. This early experience using polymer-free BA9 drug-coated stents in drug-eluting stent type patients at risk of bleeding are encouraging. Further studies are warranted. Topics: Aged; Aged, 80 and over; Aspirin; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Propensity Score; Prospective Studies; Risk Factors; Sirolimus; Treatment Outcome | 2016 |
Safety and efficacy profile of bioresorbable-polylactide-polymer-biolimus-A9-eluting stents versus durable-polymer-everolimus- and zotarolimus-eluting stents in patients with acute coronary syndrome.
Comparative data on long-term safety and efficacy of bioresorbable-polymer-BES versus durable-polymer-EES/ZES in ACS setting have hitherto been lacking. We sought to assess the safety and efficacy of bioresorbable-polymer-biolimus-A9-eluting stents (BES) compared with thin-strut-durable-polymer-everolimus- and zotarolimus-eluting stents (EES/ZES) in patients with acute coronary syndrome (ACS) undergoing PCI.. Between 2007 and 2012, 1,547 patients were implanted with new-generation drug-eluting stents (DES). Out of these, 369 received BES and 1,178 EES/ZES. The primary endpoint was probable/definite stent thrombosis (ST) while the secondary endpoint was a composite of all-cause death, myocardial infarction (MI), target vessel revascularization (TVR) and definite ST up to 5 years. As stent assignment was not random, we performed a propensity score matching (PSM), with 1:3 ratio, to account for potential confounders. Primary analysis demonstrated no significant differences between both groups for the primary endpoint of ST (BES vs.. 1.6% vs. 1.9%; mean-event-time = 1,797 days vs. 1,795 days, respectively; P = 0.75) and composite safety endpoint (BES vs.. 12.5% vs. 12.9%; mean-event-time = 1,631 days vs. 1,620 days, respectively; P = 0.88). Results regarding the 5-year-ST- and safety endpoint remained non-significant after PSM (P = 0.85, P = 0.56; respectively). After stratification based on cardiovascular risk, no difference regarding ST and composite outcome measure has been documented between both stent groups in high-risk- and low-risk patients. The type of stent did neither predict ST (HR 1.11, 95%CI 0.45-2.74, P = 0.82) nor composite safety endpoint (HR 0.93, 95%CI 0.67-1.30, P = 0.69).. Long-term safety and efficacy of bioresorbable-polymer-BES and durable-polymer-EES/ZES appear comparable in patients with ACS. © 2016 Wiley Periodicals, Inc. Topics: Absorbable Implants; Acute Coronary Syndrome; Coronary Angiography; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Polymers; Prosthesis Design; Retrospective Studies; Sirolimus; Treatment Outcome | 2016 |
Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy.
The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Occlusion; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Hypolipidemic Agents; Male; Percutaneous Coronary Intervention; Plaque, Atherosclerotic; Retreatment; Sirolimus; Stents; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
A natural light-driven inward proton pump.
Light-driven outward H Topics: Amino Acid Sequence; Animals; Bacteria; Gene Expression Regulation, Bacterial; Light; Mice; Phylogeny; Proton Pumps; Rhodopsin; Rhodopsins, Microbial; Sirolimus | 2016 |
One-year outcome from an all-comers population of patients with ST-segment elevation myocardial infarction treated with biolimus-eluting stent with biodegradable polymer.
To evaluate the performance of biolimus-eluting stent (BES) in patients with ST-elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI) in a real world clinical scenario.. Randomized studies suggest that the BES with biodegradable polymer is more effective and safe than early generation coronary stents in patients with STEMI.. We included all consecutive STEMI patients undergoing PCI in this prospective, multicenter registry. The primary endpoint of the study was the rate of major adverse cardiac events (MACE), a composite of cardiac death, recurrent myocardial infarction and ischemia-driven target vessel revascularization at 1-year follow-up.. Between June and December 2012 we enrolled 311 STEMI patients. The primary endpoint occurred in 3.2% (95% confidence interval: 1.6-5.8) of patients: cardiac death, re-infarction, and ischemia-driven TVR occurred in 2.3%, 1.3%, and 0.6% of patients, respectively. One-year MACE-free survival was 96.8% ± 1.0%.. In a real-world cohort of STEMI patients undergoing PCI, the use of BES is associated with good 1-year clinical outcome. These results confirm and expand previous findings showing the efficacy and safety of BES in the setting of randomized trials. Topics: Aged; Cardiovascular Agents; Disease-Free Survival; Drug-Eluting Stents; Female; Humans; Italy; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Recurrence; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Drug-eluting stents--SORTed.
Topics: Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Myocardial Ischemia; Percutaneous Coronary Intervention; Sirolimus | 2015 |
Biolimus-a9 eluting stent implantion for unprotected left main coronary artery stenosis: 9-month strut coverage as assessed by optical coherence tomography.
To evaluate strut coverage after biolimus-A9 eluting stent (BES) implantation for unprotected left main artery (ULMA) stenosis during follow-up and identify features associated with the length of uncovered stent segment, as assessed by frequency domain-optical coherence tomography (FD-OCT).. Incomplete stent strut coverage is a risk factor for late stent thrombosis. Long-term interaction between vessel wall and BES in the context of ULMA stenting has not been investigated in depth.. We prospectively enrolled 32 patients with ULMA stenosis treated with BES. FD-OCT was performed at 9-month follow-up. Both malapposed and uncovered segment length were indexed for the segment between the distal and proximal cross-sections in which stent struts were circumferentially visible. Patients were divided into two groups according to the median value of maximal indexed uncovered segment length. Study endpoints were the rate of strut coverage and predictors of high uncovered segment length.. We analyzed 3622 struts. The rate of covered struts was 87%. A high correlation was found between malapposed and uncovered segment length (r = 0.82; P<.001). The median value of indexed-uncovered segment length was 0.308. On multivariable analysis, patients undergoing final kissing balloon were at lower risk of high uncovered segment length (odds ratio, 0.81; 95% confidence interval, 0.008-0.837; P=.04).. In patients undergoing BES implantation for treatment of ULMA stenosis, the rate of 9-month strut coverage is high. The use of final kissing balloon reduces the risk of high uncovered stent segment length. Topics: Aged; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Prospective Studies; Prosthesis Design; Sirolimus; Surgery, Computer-Assisted; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent in patients with acute myocardial infarction.
There are limited data about long-term outcomes for biodegradable polymer biolimus-eluting stent (BES) versus durable polymer everolimus-eluting stent (EES) in patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). We sought to compare the two-year efficacy and safety of BES versus EES in AMI patients.. A total of 707 consecutive patients with ST-segment elevation myocardial infarction and non-ST-segment elevation myocardial infarction who underwent PCI with BES (n=171) or EES (n=536) between July 2008 and June 2012 were enrolled in this study. The efficacy endpoint (target vessel failure; a composite of cardiac death, target vessel-related myocardial infarction, and target vessel revascularization) and the safety endpoint (a composite of all cause death, myocardial infarction, and stent thrombosis) at two years were compared in crude and propensity score-matched cohorts.. After two years, target vessel failure occurred in 13 patients treated with BES and 49 patients treated with EES (7.6% versus 9.1%; adjusted hazard ratio [HR], 1.09; 95% confidence interval [CI], 0.58-2.04; p=0.78). The rates of composite safety endpoint at two years were not different between two groups (BES 7.6% versus EES 10.8%; adjusted HR, 0.87; 95% CI, 0.47-1.62; p=0.66). The rates of stent thrombosis did not differ between two groups (BES 0.6% versus EES 1.3%; adjusted HR, 0.63; 95% CI, 0.06-6.20; p=0.69). These findings were substantiated by similar results in the propensity score-matched cohort.. In the treatment of patients with AMI, BES showed similar efficacy and safety compared to those of EES for up to two years. Topics: Absorbable Implants; Aged; Aspirin; Clopidogrel; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Ticlopidine; Treatment Outcome | 2015 |
Outcomes following implantation of the Biolimus A9-eluting BioMatrix coronary stent: Primary analysis of the e-BioMatrix registry.
To assess the safety and efficacy of Biolimus A9-eluting stents (BES, BioMatrix™ and BioMatrix Flex™) in routine clinical practice.. The LEADERS randomized trial has documented equivalent efficacy and superior safety of the BES when compared to a first generation Sirolimus-eluting Cypher(TM) stent.. 5,472 patients from 57 centers, treated with BES, were enrolled in an international multicenter registry and followed clinically up to 2 years.. Mean patient age was 63.2 ± 11 years, 24% of patients had diabetes, and 49.8% presented with an acute coronary syndrome. 99.3% of patients were discharged on dual antiplatelet therapy (DAPT), 83.3% remained on DAPT at 1 year and 30.6% at 2 years. The incidence of the composite primary end point [major adverse cardiac events (MACE) at 12 months] was 4.5% [cardiac death 0.9%, myocardial infarction 1.7%, clinically indicated target vessel revascularization (ci-TVR) 2.8%]. MACE incidence was 6.8% at 24 months (cardiac death 1.5%, myocardial infarction 2.4%, ci-TVR 4.3%). At 12 months, 32 patients (0.6%) had suffered at least one definite or probable stent thrombosis (ST), and 91 patients (1.7%) a major bleed (MB). Nine patients with ST (27.3%) and 7 patients with a MB (7.7%) died during the first year after the index procedure. Between 12 and 24 months after implantation, there were 18 (0.4%) additional MB and 8 (0.2%) additional ST.. This large international cohort documents a low 12 and 24 months MACE incidence and a very low ST incidence in an unselected patient population undergoing BES implantation. The results are in keeping with those of the randomized controlled LEADERS trial. Even though ST with this stent was a rare event, it was still associated with significant mortality. MB remains a problem, and warrants improved tailoring of DAPT in recipients of drug eluting stents. Topics: Aged; Cardiovascular Agents; Comorbidity; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Incidence; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Bioresorbable vascular scaffolds in daily clinical practice: is the essential really invisible to the eyes?
Topics: Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Percutaneous Coronary Intervention; Postoperative Complications; Sirolimus | 2015 |
Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction: the IBIS-4 (integrated biomarker and imaging study) substudy.
We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number of pullbacks suitable for analysis. Safety parameters included the frequency of peri-procedural complications, and major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and any clinically-indicated revascularization at 2 years. Clinical outcomes were compared with the results from a cohort of 485 STEMI patients undergoing primary PCI without additional imaging. Imaging of the infarct-related artery at baseline (and follow-up) was successful in 92.2% (96.6%) of patients using OCT and in 93.2% (95.5%) using IVUS. Imaging of the non-infarct-related vessels was successful in 88.7% (95.6%) using OCT and in 90.5% (93.3%) using IVUS. Periprocedural complications occurred <2.0% of OCT and none during IVUS. There were no differences throughout 2 years between the imaging and control group in terms of MACE (16.7 vs. 13.3%, adjusted HR1.40, 95% CI 0.77-2.52, p = 0.27). Multi-modality three-vessel i.c. imaging in STEMI patients undergoing primary PCI is consistent a high degree of success and can be performed safely without impact on cardiovascular events at long-term follow-up. Topics: Aged; Cardiovascular Agents; Coronary Vessels; Drug-Eluting Stents; Europe; Feasibility Studies; Female; Humans; Male; Metals; Middle Aged; Multimodal Imaging; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2015 |
Early development of coronary artery aneurysms after implantation of biolimus-eluting stent with biodegradable polymer.
Topics: Absorbable Implants; Angina Pectoris; Angioplasty, Balloon, Coronary; Antibiotics, Antineoplastic; Coronary Aneurysm; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Echocardiography, Stress; Humans; Male; Middle Aged; Monitoring, Physiologic; Platelet Aggregation Inhibitors; Sirolimus; Treatment Outcome | 2015 |
Accuracy of optical frequency domain imaging for evaluation of coronary adventitial vasa vasorum formation after stent implantation in pigs and humans - a validation study - .
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation causes the enhancement of VV formation, with extending to the stent edges in the porcine coronary arteries, and also that optical frequency domain imaging (OFDI) is capable of visualizing VV in humans in vivo. However, it remains to be fully validated whether OFDI enables the precise measurement of VV formation in pigs and humans.. In the pig protocol, a total of 6 bare-metal stents and 12 drug-eluting stents were implanted into the coronary arteries, and at 1 month, the stented coronary arteries were imaged by OFDI ex vivo. OFDI data including the measurement of VV area at the stent edge portions were compared with histological data. There was a significant positive correlation between VV area on OFDI and that on histology (R=0.91, P<0.01). In the human protocol, OFDI enabled the measurement of the VV area at the stent edges after coronary stent implantation in vivo.. These results provide the first direct evidence that OFDI enables the precise measurement of the VV area in coronary arteries after stent implantation in pigs and humans. Topics: Adventitia; Aged; Aged, 80 and over; Animals; Aspirin; Clopidogrel; Coronary Stenosis; Coronary Vessels; Disease Progression; Drug-Eluting Stents; Everolimus; Female; Humans; Interferometry; Male; Middle Aged; Neointima; Neovascularization, Physiologic; Platelet Aggregation Inhibitors; Postoperative Period; Prosthesis Implantation; Sirolimus; Stents; Swine; Swine, Miniature; Ticlopidine; Tomography, Optical Coherence; Vasa Vasorum; Vasculitis | 2015 |
Visualization of the human coronary vasa vasorum in vivo.
Topics: Adventitia; Animals; Coronary Stenosis; Coronary Vessels; Everolimus; Female; Humans; Male; Neovascularization, Physiologic; Prosthesis Implantation; Sirolimus; Stents; Tomography, Optical Coherence; Vasa Vasorum | 2015 |
The EXCEL and NOBLE trials: similarities, contrasts and future perspectives for left main revascularisation.
Unprotected left main coronary artery (ULMCA) stenosis has relatively high prevalence and exposes patients to a high risk for adverse cardiovascular events. The optimal revascularisation strategy (coronary artery bypass surgery [CABG] or percutaneous coronary intervention [PCI]) for patients with complex coronary artery disease is a topic of continuing debate. The introduction of the newer-generation drug-eluting stents (DES) -with documented improvements in both safety and efficacy- has prompted the interventional community to design two new dedicated randomised trials comparing CABG and PCI: the NOBLE (Coronary Artery Bypass Grafting Vs Drug Eluting Stent Percutaneous Coronary Angioplasty in the Treatment of Unprotected Left Main Stenosis) and EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trials. The aims of the present review are to describe the similarities and contrasts between these two trials as well to explore their future implications in ULMCA treatment. Topics: Angioplasty, Balloon, Coronary; Antineoplastic Agents; Coronary Artery Bypass; Coronary Stenosis; Drug-Eluting Stents; Everolimus; Humans; Percutaneous Coronary Intervention; Randomized Controlled Trials as Topic; Sirolimus; Treatment Outcome | 2015 |
The Axxess stent.
Topics: Alloys; Antibiotics, Antineoplastic; Coronary Stenosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Self Expandable Metallic Stents; Sirolimus; Treatment Outcome | 2015 |
Comparison of Biolimus- and Everolimus-eluting stents in terms of clinical outcomes in patients with acute myocardial infarction: Results from the Korea Working Group on Myocardial Infarction (KorMI) Registry.
Topics: Aged; Drug Evaluation; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Mortality; Myocardial Infarction; Prognosis; Registries; Retrospective Studies; Sirolimus; Treatment Outcome | 2015 |
Instant Stent-Accentuated 3-Dimensional Optical Coherence Tomography of Struts Pulled Up by Pulling Stuck Wire and Folded by Kissing Balloon Dilation.
Topics: Angioplasty, Balloon, Coronary; Cardiac Catheters; Cardiovascular Agents; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Imaging, Three-Dimensional; Male; Middle Aged; Predictive Value of Tests; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Drug-Eluting Stent Implantation on Calcified Nodule: Ex Vivo Intravascular Images and Histopathology.
Topics: Aged; Angioscopy; Autopsy; Biopsy; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Fatal Outcome; Female; Humans; Percutaneous Coronary Intervention; Sirolimus; Treatment Outcome; Ultrasonography, Interventional; Vascular Calcification | 2015 |
Serial Optical Coherence Tomography Evaluation at 6, 12, and 24 Months After Biolimus A9-Eluting Biodegradable Polymer-Coated Stent Implantation.
The Nobori (Terumo Corporation, Tokyo, Japan) is a biolimus A9-eluting stent (BES) featured with a biodegradable polymer coated on the abluminal side only. We previously reported that favourable vessel healing was achieved at 6-12 months after BES implantation. However, detailed long-term vessel reaction after BES deployment is unclear.. Twenty-two BESs were serially evaluated using optical coherence tomography (OCT) at 6, 12, and 24 months after stenting. Average neointimal thickness, uncovered struts, and neointimal unevenness score (each cross-section as maximum neointimal thickness in 1 cross section divided by the average neointimal thickness of the same cross-section) were manually measured. In addition, we evaluated the percentage of struts with peri-strut low-intensity area (a region around stent struts that homogenously showed less intensity than the surrounding tissue, which suggests fibrin deposition or impaired neointima maturation), thrombi, and atherogenic neointimas (neointimas containing a diffuse border and poor-signal region with invisible struts due to marked signal attenuation).. Serial OCT observation revealed a small gradual increase in neointimal thickness from 6 to 24 months (73 ± 24 μm; 81 ± 26 μm; and 108 ± 35 μm, respectively, P = 0.001) with a nonsignificant decrease in the lumen area (6.36 ± 1.98 mm(2); 6.18 ± 2.04 mm(2); and 5.87 ± 2.06 mm(2); P = 0.72). Frequency of uncovered struts (3.89 ± 3.91%; 1.55 ± 1.63%; and 0.23 ± 0.67%; P = 0.001), neointimal unevenness score (1.95 ± 0.18% to 1.86 ± 0.19% to 1.78 ± 0.17; P = 0.012), percentage of thrombi (5%, 0%, and 0%; P = 0.37) and peri-strut low-intensity area (6.8%, 5.1%, and 1.6%; P = 0.017) decreased from 6 to 12 and 24 months. Atherogenic neointima was not observed in the event-free OCT cohort.. The Nobori stent achieved acceptable long-term vessel healing, mostly without adverse vessel reactions. Topics: Aged; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Male; Neointima; Polymers; Prospective Studies; Prosthesis Design; Reproducibility of Results; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2015 |
A comparison of drug eluting stent biocompatibility between third generation NOBORI biolimus A9-eluting stent and second generation XIENCE V everolimus-eluting stent in a porcine coronary artery model.
NOBORI biolimus A9-eluting stent (BES) is the third generation drug eluting stent (DES) with only abluminal biodegradable polymer. Recent clinical trials have indicated that the BES is non-inferior to the XIENCE V everolimus-eluting stent (EES). Meanwhile, potential superiority of biodegradable polymer BES over current generation DES has not been addressed. The aim of this preclinical study was to assess and compare the biocompatibility of both BES and EES in porcine coronary arteries.. BES with length of 24-mm (n=9) and EES with length of 23-mm (n=9) were both implanted in porcine coronary arteries. At 28 days endothelium-dependent vasomotion was assessed by acetylcholine (Ach) and subsequently measurements of endothelial superoxide production, histological evaluations and microarray gene analyses were performed.. Angiographic and histological in-stent stenoses were significantly suppressed in BES compared with EES. Histopathological assessment showed lower inflammatory score as well as fibrin and injury scores in BES as compared with EES. On the contrary, paradoxical vasoconstriction to Ach was frequently observed in EES-treated vessels compared with BES-treated vessels. Additionally, gene expressions of inflammatory cytokines and chemokines were upregulated in vessels treated with EES compared with BES in microarray pathway specific analyses.. Implantation of BES revealed less inflammation and foreign-body immunoreaction than EES, suggesting more enhanced biocompatibility of BES compared with EES at 28 days in porcine coronary arteries. Topics: Animals; Biocompatible Materials; Coronary Stenosis; Disease Models, Animal; Drug-Eluting Stents; Everolimus; Immunosuppressive Agents; Materials Testing; Sirolimus; Swine; Treatment Outcome | 2015 |
Successful retrograde percutaneous coronary intervention to a right coronary ostium agenesis via an extremely tortuous epicardial collateral.
Topics: Adult; Cardiovascular Agents; Collateral Circulation; Coronary Angiography; Coronary Circulation; Coronary Vessel Anomalies; Coronary Vessels; Drug-Eluting Stents; Humans; Male; Percutaneous Coronary Intervention; Sirolimus; Treatment Outcome | 2015 |
Immediate and Long-Term Results of Drug-Eluting Stents in Mammary Artery Grafts.
Percutaneous intervention of a coronary graft is the treatment of choice when the graft fails. The objective is to report the long-term results of drug-eluting stents (DES) in mammary artery grafts (MAG). Patients who had been treated with DES for MAG in 27 centers were selected. The baseline and procedural clinical data were included prospectively, and the follow-up was performed with the patients, families, and medical records. Two hundred and sixty-eight patients were included: age 65.5 ± 10.1 years, diabetes 47.8%, ejection fraction 55.5 ± 14.9%.. stable angina 28.4%, unstable angina 38.1%, non-ST-elevation myocardial infarction 21.6%, ST-elevation myocardial infarction 5.3%, and heart failure 6.7%; 1.19 ± 0.59 stents/patient were implanted measuring 18.8 ± 8.8 mm in length and 2.68 ± 0.35 mm in diameter. Rapamycin was used in 78 cases (29.1%), paclitaxel in 77 (28.7%), everolimus in 70 (26.1%), zotarolimus in 34 (12.7%), and biolimus in 9 (3.4%). All cases were successful except for 1 in which the patient died 30 minutes after the procedure. There were no other inhospital events. After a follow-up of 41 months (Q25: 23.7 to Q75: 57.8), 24 patients (9%) died of heart-related causes and 20 (7.5%) of noncardiac causes. Repeat revascularization was necessary in 31 cases, and in 1 additional patient, there was total occlusion, which was not treated. These 32 patients represented 11.9% of the total. In conclusion, the implantation of DES in MAG shows very high procedural success and also low long-term event rates. Topics: Aged; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Internal Mammary-Coronary Artery Anastomosis; Male; Middle Aged; Paclitaxel; Sirolimus; Treatment Outcome | 2015 |
Comparison of First- and Second-Generation Drug-Eluting Stents in an All-Comer Population of Patients with Diabetes Mellitus (from Katowice-Zabrze Registry).
This study compared safety and efficacy of first- and second-generation DES in an unrestricted, real-life population of diabetic patients undergoing PCI.. The study was a subanalysis of diabetic patients from the all-comer Katowice-Zabrze Registry of patients undergoing PCI with the implantation of either first- (Paclitaxel-, Sirolimus-eluting stents) or second-generation DES (Zotarolimus-, Everolimus-, Biolimus-eluting stents). Efficacy defined as major adverse cardiac and cerebrovascular events (MACCE: death, myocardial infarction, target vessel revascularization, stroke) and safety defined as stent thrombosis (ST) were evaluated at 1 year.. From the total of 1916 patients, 717 were diabetics. Among them, 257 (36%) were treated with first-generation DES (230 [89%] Paclitaxel-eluting stents, 27 [11%] Sirolimus-eluting stents), 460 with second-generation DES (171 [37%] Zotarolimus-eluting stents, 243 [53%] Everolimus-eluting stents, 46 [10%] Biolimus-eluting stents). Rate of MACCE was equal in both groups (p=0.54). Second-generation DES had a better safety profile than first-generation DES (log-rank for cumulative ST at 1 year p<0.001). First-generation DES was a risk factor for ST (HR 5.75 [1.16-28.47], p=0.03) but not for MACCE (HR 0.89 [0.6-1.32], p=0.57).. In a real-life setting of diabetic patients undergoing PCI, second-generation DES had lower risk of ST and similar MACCE rate compared to first-generation DES. Topics: Aged; Angiography; Coronary Stenosis; Diabetes Mellitus; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Myocardial Revascularization; Paclitaxel; Percutaneous Coronary Intervention; Poland; Proportional Hazards Models; Registries; Retrospective Studies; Sirolimus; Stents; Thrombosis; Treatment Outcome | 2015 |
A very late thrombosis in a bioresorbable vascular scaffold.
Topics: Absorbable Implants; Adult; Coronary Angiography; Coronary Thrombosis; Drug-Eluting Stents; Humans; Inferior Wall Myocardial Infarction; Male; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Prosthesis Failure; Recurrence; Retreatment; Sirolimus; Thrombectomy; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.
To compare biodegradable polymer biolimus-eluting (BES) with abluminal drug elution and durable polymer everolimus-eluting (EES) stents in the treatment of bifurcation lesions.. The persistence of a polymer in drug-eluting stents (DES) following drug elution has been viewed as a possible culprit for restenosis. DES with biodegradable polymer may thus be associated with improved clinical outcomes, especially in high-risk lesions such as those at bifurcation sites.. We performed a retrospective study of consecutive de novo bifurcation lesions treated with EES between October 2006 and October 2011 and BES between February 2008 and March 2012. Study endpoints included major adverse cardiac events (MACE) defined as all-cause death, myocardial infarction (MI), including peri-procedural MI, and target vessel revascularization (TVR) as well as target lesion revascularization (TLR) separately.. We analyzed 236 bifurcation lesions treated with either BES (79 lesions in 69 patients) or EES (157 lesions in 154 patients). Patient and procedural characteristics were broadly similar between the two groups. Estimated MACE and TVR rates at 2-year follow-up were similar between the BES and EES groups (MACE = 13.6 ± 4.6% vs. 14.6 ± 3.2% (P = 0.871); TVR = 6.9 ± 3.5% vs. 8.0 ± 2.7% (P = 0.889). No significant differences were noted between the two groups following propensity-score matched analysis. There was no probable or definite stent thrombosis.. BES use in the treatment of bifurcation lesions appears to be associated with good clinical outcomes, comparable to those seen with EES, at long-term follow-up. These results are hypothesis-generating and need to be validated with larger studies. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Retrospective Studies; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Needs for monitoring mosquito transmission of malaria in a pre-elimination world.
As global efforts to eliminate malaria intensify, accurate information on vector populations and transmission dynamics is critical for directing control efforts, developing new control tools, and predicting the effects of these interventions under various conditions. Currently available sampling tools for mosquito population monitoring suffer from well-recognized limitations. As reported in this workshop summary, a recent gathering of medical entomologists, modelers, and malaria experts reviewed these issues and agreed that efforts are needed to improve methods to monitor key transmission parameters. Identified needs include standardized methods for sampling of both mosquito adults and larvae, improved tools for mosquito species identification and age-grading, and a better means for determining the entomological inoculation rate. Topics: Animals; Culicidae; Global Health; Humans; Insect Vectors; Larva; Malaria; Sirolimus | 2014 |
Procedural and follow-up outcomes among patients undergoing successful recanalisation of coronary chronic total occlusions using biolimus drug-eluting stents.
This study aimed at evaluating the outcome of Biolimus eluting stent (BES) implantation in the treatment of chronic total coronary occlusions (CTO). We identified patients who underwent successful angioplasty for a CTO lesion with ≥1 BES between June 2008 and March 2012. All patients were followed up for major adverse cardiac events (MACE), which comprised death, non-fatal myocardial infarction (MI), cerebrovascular accident, target vessel revascularization (TVR), target lesion revascularization (TLR) and stent thrombosis. 125 patients underwent successful CTO angioplasty with ≥1 Biolimus-eluting stents. Mean age was 63.8 ± 12.0 years, and 82.4 % were males. Lesion location was right coronary artery (n = 80, 64 %), left anterior descending artery (n = 35, 28 %) and left circumflex artery (n = 10, 8 %). During follow-up of 579 ± 293 days, all cause mortality was n = 8 (6.4 %) patients, non-fatal MI was n = 3 (2.4 %), TVR was n = 3 (2.4 %) and TLR was n = 1 (0.8 %). Overall MACE was, therefore, n = 15 (12 %). BES is safe and effective in treatment of CTO lesions, with a low rate of major adverse cardiovascular events during follow-up. Topics: Anti-Inflammatory Agents; Coronary Occlusion; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Percutaneous Coronary Intervention; Retrospective Studies; Sirolimus; Survival Analysis; Treatment Outcome | 2014 |
Clinical outcomes with 6 months dual antiplatelet therapy after implantation of biolimus-A9 drug eluting coronary stents.
Duration of dual antiplatelet therapy (DAPT) following drug eluting stent (DES) implantation remains poorly defined. Endothelialisation of biodegradable polymer biolimus-eluting stents occurs early, and 6 months DAPT may be adequate.. We evaluated long term outcome in patients treated with biolimus-eluting stents who were treated with 6 months DAPT. Endpoints included cardiac death and non-fatal stent thrombosis occurring 6 to 12 months after stent implantation.. 692 patients (77.2% male), aged 65.6 ± 12.5 years received biolimus-eluting DES (March 2008 -November 2011). Vital status was tracked through the Medical Research Information Service. Episodes of non-fatal stent thrombosis, (Academic Research Consortium definition) between months 6 and 12 were tracked via systematic database searches (5 PCI centres).. Presentations included acute coronary syndrome (47.2%) and stable coronary disease (52.8%). Vessels treated included left main stem (6.8%), left anterior descending (37.4%), circumflex (19.1%), right coronary artery (34.5%) and saphenous vein graft (2.1%) respectively. High-risk subsets included diabetes (15.6%); AHA type C lesions (35.1%) and chronic total occlusions (12.8%). During median follow-up of 700 days (0 to 1392) there were 42 deaths (6.1%); 4.2% at 0-6 months, 1.0% at 6-12 months and 0.9% at >12 months. Of the 7 deaths between 6 and 12 months, one death was adjudicated as possible stent thrombosis. There were no cases of non-fatal known stent thrombosis. All cause mortality accrued with smooth decremental incidence. Statistical examination showed no evidence of event clustering between 6 and 12 months.. After implantation of biodegradable polymer biolimus-eluting coronary stents, 6 months DAPT appears to be adequate, safe and effective. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Immunosuppressive Agents; Male; Middle Aged; Platelet Aggregation Inhibitors; Retrospective Studies; Risk Factors; Sirolimus; Survival Analysis; Treatment Outcome | 2014 |
Incidence and clinical impact of stent fracture after the Nobori biolimus-eluting stent implantation.
Stent fracture (SF) after drug-eluting stent implantation has become an important concern. The aim of this study was to assess the incidence, predictors, and clinical impact of SF after biolimus-eluting stent.. A total of 1026 patients with 1407 lesions undergoing the Nobori biolimus-eluting stent implantation and follow-up angiography within 9 months after index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by using plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months. SF was observed in 58 (4.1%) of 1407 lesions and 57 (5.5%) of 1026 patients. Lesions with hinge motion (OR 8.90, 95% CI 3.84 to 20.6, P<0.001), tortuosity (OR 4.16, 95% CI 1.75 to 9.88, P=0.001), and overlapping stents (OR 2.41, 95% CI 0.95 to 6.10, P=0.06) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9 months was numerically higher in the SF group than that in the non-SF group (12.0% versus 1.0%). Cumulative incidence of definite stent thrombosis within 9 months tended to be higher in the SF group than that in the non-SF group (1.7% versus 0.5%).. SF after biolimus-eluting stent occurs in 4.1% of lesions and appears to be associated with clinically driven target lesion revascularization. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Incidence; Japan; Logistic Models; Male; Middle Aged; Multivariate Analysis; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Prosthesis Failure; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2014 |
Placement of a single Axxess stent as new treatment strategy for Medina 1,0,0 left main stem bifurcation lesion.
A left main stem bifurcation lesion (Medina 1,0,0) treated with a single Axxess stent through radial access is presented. Although the use of this stent in left main stenosis is off label, in selected cases it may simplify the technique, avoiding the use of additional overlapping stents and ensuring the bifurcation coverage with minimal amount of metal at the carina. Topics: Aged; Angioplasty, Balloon, Coronary; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Echocardiography; Humans; Male; Radial Artery; Sirolimus; Treatment Outcome | 2014 |
Treatment of coronary bifurcations with third generation drug-eluting stent: making major headway or just baby steps?
Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Percutaneous Coronary Intervention; Polymers; Sirolimus | 2014 |
Intricacies in the analysis and interpretation of optical coherence tomography findings.
Topics: Cardiovascular Agents; Coronary Stenosis; Coronary Vessels; Female; Humans; Male; Percutaneous Coronary Intervention; Sirolimus; Tomography, Optical Coherence | 2014 |
Automated assessment and 3-dimensional visualization of the pattern of neointimal tissue maturity in vivo following drug-eluting stent implantation.
Topics: Algorithms; Angina, Unstable; Automation; Cardiovascular Agents; Coronary Vessels; Drug-Eluting Stents; Humans; Image Interpretation, Computer-Assisted; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Wound Healing | 2014 |
Can optical coherence tomography findings be used as surrogates for vessel healing after drug-eluting stent implantation?
Topics: Biodegradable Plastics; Drug-Eluting Stents; Female; Humans; Male; Regeneration; Sirolimus; Tomography, Optical Coherence | 2014 |
Comparison of the safety and efficacy of biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents: propensity score-matched analysis.
We investigated and compared the clinical outcomes between biodegradable polymer biolimus-eluting stents (BES) and durable polymer everolimus-eluting stents (EES) in a single-center prospective registry.. There is limited data regarding the safety and efficacy of the biodegradable BES compared to second-generation drug-eluting stents.. From January 2010 to April 2012, a total of 1,279 patients were treated with BES (n = 647) or EES (n = 632) in a single center. We included 1,231 patients (BES = 625, EES = 606) after excluding 48 patients (BES = 22, EES = 26) with acute myocardial infarction accompanied by cardiogenic shock. The 1-year incidences of target lesion failure (TLF), patient-oriented composite outcomes (POCO), and stent thrombosis (ST) after the index procedure were compared in propensity score-matched analyses.. Propensity score matching yielded 406 well-balanced pairs (EES = 406, BES-B = 406). In the propensity-matched population, the 1-year incidence of TLF (BES = 3.0% vs. EES = 2.5%, P = 0.666) and POCO (BES = 5.4% vs. EES = 6.4%, P = 0.552) were similar between the 2 groups. In addition, the incidence of definite or probable ST was also similar (BES = 0.74% vs. EES = 0.74%, P = 1.000). In subgroup analysis, the number of patients who reached the primary end-point did not differ significantly between the 2 groups.. In a single-center registry with unrestricted use of EES and BES-B, these stents showed comparable efficacy and safety in terms of TLF, POCO, and ST at 1-year follow-up. Topics: Absorbable Implants; Aged; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Patient Outcome Assessment; Percutaneous Coronary Intervention; Propensity Score; Prospective Studies; Registries; Sirolimus | 2014 |
Long-term coronary arterial response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents: five-year follow-up optical coherence tomography study.
The long-term coronary arterial response of biodegradable polymer biolimus-eluting stents (BES) remains unclear. We sought to evaluate the coronary arterial response of biodegradable polymer BES at 5 years after stent implantation using optical coherence tomography (OCT) as compared with that of durable polymer sirolimus-eluting stents (SES) and bare-metal stents (BMS).. Five-year follow-up OCT was performed in 30 patients with 33 stents (10 with 12 BES; 10 with 11 SES; 10 with 10 BMS). Quantitative parameters and qualitative characteristics of the neointima were evaluated. A total of 5178 struts (BES, n = 2056; SES, n = 1410; BMS, n = 1712) were analyzed.. Uncovered struts were found in 15 out of 2055 struts in the BES (weighted estimate 0.01%, 95% confidence intervals [CI]: 0.00-0.33%) and 54 out of 1410 struts in the SES (0.11%, 95% CI: 0.00-3.33%) (odds ratio [OR] 0.12, 95% CI: 0.01-1.95, p = 0.13). None of 1712 struts were uncovered in the BMS. Cross-sectional qualitative analysis of neointimal tissue showed that the frequency of lipid-laden neointima tended to be lower in the BES (2.26%, 95% CI: 0.38-12.3%) compared with the SES (9.90%, 95% CI: 4.37-20.9%; OR 0.21, 95% CI 0.03-1.16, p = 0.07), and was similar to the BMS (2.23%, 95% CI: 0.54-8.74%; OR 0.98, 95% CI 0.13-7.14, p = 0.98).. Biodegradable polymer BES shows a favorable coronary arterial response compared with SES, but different response with BMS at 5 years follow-up. The observed frequency of in-stent neoatherosclerosis within BES was similar to BMS and tended to be lower than SES. Topics: Absorbable Implants; Aged; Aged, 80 and over; Atherosclerosis; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Lipids; Male; Metals; Neointima; Polymers; Sirolimus; Stents; Ticlopidine; Time Factors; Tomography, Optical Coherence | 2014 |
Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model.
Biodegradable polymer-based drug-eluting stents are thought to be safer than durable polymer-based stents. However, the long-term vascular response remains unclear. The aim of this study was to compare the biocompatibility of durable polymer-based sirolimus-eluting (SES) and everolimus-eluting (EES) stents with biodegradable polymer-based biolimus-eluting (BES) stents in a porcine coronary model. Stents were implanted in porcine coronaries. Acetylcholine challenge tests and optical coherence tomography (OCT) examination were performed at one month. Animals were sacrificed at three and six months (n=6 each), and the stents were analysed histologically. At one month, acetylcholine challenge tests revealed a trend towards greatest vasoconstriction in SES, less in BES, and least in EES, but the differences were not significant. OCT analysis demonstrated the highest incidence of uncovered struts in SES, followed by BES, while EES showed almost complete strut coverage (41.7±27.0%, 24.5±23.8%, 0.4±0.8%, respectively; p=0.004). Upon histological analysis at three months, SES showed a significantly higher inflammatory score than BES and EES (2.9±1.4, 0.8±0.9, 0.5±0.4, respectively; p=0.001), and this was maintained at six months (1.6±1.5, 0.3±0.3, 0.4±0.6, respectively; p=0.049). While SES showed an increased inflammatory reaction, EES and BES showed minimal inflammation. These results indicate that the late inflammatory reaction does not necessarily depend on degradability of the polymer, if the combination of the drug, metal, and polymer is biocompatible. Topics: Absorbable Implants; Acetylcholine; Animals; Coated Materials, Biocompatible; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Everolimus; Inflammation; Materials Testing; Models, Animal; Neointima; Polymers; Sirolimus; Swine; Tomography, Optical Coherence; Vasodilator Agents | 2014 |
One-year outcome of biolimus eluting stent with biodegradable polymer in all comers: the Italian Nobori Stent Prospective Registry.
INSPIRE-1 (Italian Nobori Stent ProspectIve REgistry-1) was designed and conducted to assess clinical performance of Nobori biolimus A9-eluting stent (BES) implantation in an unrestricted "real-world" cohort of patients.. Unrestricted consecutive high-risk patients treated with BES with biodegradable polymer (Nobori, Terumo, Tokyo, Japan) between February 2008 and July 2012 were prospectively enrolled in an independent multicenter registry and divided in two groups: complex and non complex lesions.. 1066 patients (1589 lesions) treated with Nobori BES were analyzed. The majority of patients (57%) were treated for at least one complex lesion and presented a high-risk clinical profile (previous CABG 17.6%, diabetes mellitus 33.1%, chronic kidney disease 14.3%). Angiographic success rate was achieved in 96.2% cases. At 1 year, the primary endpoint, (composite of cardiac death, myocardial infarction, and clinically driven target vessel revascularization), occurred in 39 (4.0%) patients, and was higher in the complex lesions (5.2% vs. 2.5%, P = 0.032). Target lesion failure (TLF, secondary endpoint) occurred in 45 (4.6%) patients, and was more frequent in the complex lesions group (6.2% vs. 2.7%, P = 0.011), mainly due to a higher incidence of any target lesion revascularization (4.8% vs. 2.7%; P = 0.095). Definite and probable stent thrombosis (ST) rate was 0.6% and 0.5% respectively, with no difference between groups.. In unrestricted daily practice, BESs were implanted predominantly in high risk patients with complex lesions. Despite this, the Nobori BES was associated with a relatively low rate of primary endpoint and TLF, with a higher risk in patients with complex lesions. Topics: Absorbable Implants; Aged; Cohort Studies; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; Italy; Male; Middle Aged; Myocardial Infarction; Polymers; Prospective Studies; Registries; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Efficacy and safety of biodegradable polymer biolimus A9-eluting stent versus durable polymer everolimus-eluting stent in diabetic patients: a prospective non-randomized single-centre long-term comparison.
Biodegradable polymer drug-eluting stents may improve biocompatibility and reduce the risk of very late stent thrombosis (ST) but outcomes are nevertheless unknown in diabetic patients. The purpose of this study was to assess the long-term efficacy and safety of the biodegradable polymer biolimus A9-eluting stent (BP-BES) in comparison with the current reference durable polymer everolimus-eluting stent (DP-EES) in diabetic patients.. 119 BP-BES and 178 DP-EES were implanted respectively in 105 and 146 diabetic patients presenting similar clinical and peri-procedural characteristics. The median follow-up time was 20.8 months. No statistically significant difference was observed between the BP-BES and DP-EES groups in terms of occurrence of the composite primary end point of cardiac death, spontaneous myocardial infarction and clinically indicated target lesion revascularization (8 patients [8%] in the BP-BES group versus 24 patients [17%] in the DP-EES group; HR 1.36, 95% CI 0.59-3.15, P = 0.47) and of the rate of ST (5 patients [5%] in the BP-BES group versus 11 patients [8%] in the DP-EES group; HR 0.73, 95% CI 0.22-2.37, P = 0.60).. In spite of a trend in favour of the BP-BES, long-term efficacy and safety were similar for both the BP-BES and the DP-EES in this specific population of diabetic patients. Considering the low incidence of the studied clinical events, other studies with larger population sizes are needed to confirm this observation. Topics: Aged; Cardiovascular Diseases; Coated Materials, Biocompatible; Diabetes Complications; Drug-Eluting Stents; Everolimus; Female; Humans; Immunosuppressive Agents; Male; Patient Safety; Polymers; Prospective Studies; Registries; Sirolimus | 2014 |
Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix DES by OCT. 20 patients undergoing BioMatrix DES (n = 15) or S-Stent BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix and S-Stent, respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix = 9 and S-Stent = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix group compared to 23 (4.0 %) in the S-Stent group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2013 |
Long-term comparison of everolimus-eluting and biolimus-eluting stents.
Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients.. A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (HR 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (HR 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0).. This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES). Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
New-generation drug-eluting stent experience in the percutaneous treatment of unprotected left main coronary artery disease: the NEST registry.
To explore the 2-year clinical outcomes in patients with unprotected left main coronary artery (ULMCA) disease treated with overall new drug-eluting stent (DES) options.. Recent available data have shown the feasibility and the safety of new DESs, mainly evaluating the everolimus-eluting stents in the setting of ULMCA disease.. Patients with ULMCA disease undergoing percutaneous coronary intervention (PCI) with everolimus-, zotarolimus-, and biolimus A9-eluting stents were prospectively evaluated. The study objective was the composite of major adverse cardiac events (MACEs), consisting of all-cause mortality, myocardial infarction (MI), and target vessel revascularization (TVR) at 2-year clinical follow-up.. A total of 154 patients were analyzed. The mean EuroSCORE and SYNTAX scores were 4.7 ± 2.6 and 27.5 ± 8.3, respectively. Distal location was present in 126 patients (81.8%) and 96 lesions (76.3%) were true Medina bifurcations. The 2-stent technique was used in 73 cases (57.9%). Everolimus-, zotarolimus-, and biolimus A9-eluting stents were implanted in 68 patients (44.2%), 46 patients (29.9%), and 40 patients (25.9%), respectively. At a median clinical follow-up of 551.5 days (interquartile range, 360.8-1045.5 days), MACEs occurred in 29 patients (18.8%). Ten patients (6.5%) died, and 2 deaths (1.3%) were adjudicated as cardiac. No patient had myocardial infarction or definite stent thrombosis (ST). One probable and 1 possible ST were adjudicated. TVR was required in 19 patients (12.3%) and target lesion revascularization was required in only 7 patients (4.5%).. In our experience, despite the presence of complex distal left main lesions, new DESs in ULMCA disease appear to be promising in terms of safety and efficacy at 2-year clinical follow-up. Topics: Aged; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Follow-Up Studies; Humans; Incidence; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Registries; Retrospective Studies; Sirolimus; Thrombosis; Treatment Outcome | 2013 |
Optical frequency domain imaging for guidance of optimal stenting in the setting of recanalization of chronic total occlusion.
We present an interesting case illustrating how coronary optical frequency domain imaging (OFDI) examination can be used to guide revascularization of a complex chronic total occlusion (CTO) in a patient presenting to our hospital with a 2-year history of angina, dyspnea, and a positive treadmill test. This case demonstrates the potential clinical role of high-resolution OFDI to optimize coronary stent implantation. OFDI may help to limit the coronary area covered by stents to the true coronary lesion. Topics: Angioplasty, Balloon, Coronary; Chronic Disease; Coronary Angiography; Coronary Occlusion; Coronary Vessels; Drug-Eluting Stents; Humans; Male; Middle Aged; Regional Blood Flow; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2013 |
Experience with BioMatrix BES and other DES in all-comers setting: a retrospective overview.
New generation DES are effectively used in all spectrum of coronary artery diseases (CAD) and are replacing earlier DES and BMS. Biolimus A9™-eluting stent is a new generation DES containing the anti-proliferative drug biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia. A retrospective data analysis was done in patients treated with DES, with a major share of Biolimus A9™ (BA9™) drug-eluting stents (DES) at Bombay Hospital, Mumbai. A total of 158 patients with 219 lesions were treated with DES, comprising Biolimus A9-eluting stent and others and the major adverse cardiac events (MACE) rate and stent thrombosis (ST) at 1, 6, 12 months and 24 months were analyzed. Mace rate was 3.16% for average follow-up of 19 months. There were 3 cases of ST (2 of acute and 1 of subacute onset) and one non-cardiac death reported during this time. This retrospective data demonstrates good one- and two-year clinical safety and efficacy of DES, especially of BioMatrix stents in real world setting. Topics: Absorbable Implants; Adult; Age Factors; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Cause of Death; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Female; Follow-Up Studies; Humans; India; Male; Middle Aged; Myocardial Infarction; Polymers; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Sex Factors; Sirolimus; Survival Rate; Treatment Outcome; Young Adult | 2013 |
Critical in-stent restenosis following fracture of biolimus-eluting stent: a report of 2 cases.
The development of drug-eluting stents (DES) has dramatically reduced the incidence of in-stent restenosis. Stent fracture (SF) of DESs, however, has recently emerged as a rare but serious complication, which may lead to acute coronary syndrome or sudden cardiac death. DES fracture results from metal fatigue and vessel hemodynamic stress on the stent strut, due to markedly reduced neointimal formation. Although actual incidence of SF is not known, previous reports have demonstrated that SF rates are specific to each DES type. In this report, 2 cases of fracture of a Nobori stent are described, with insights into the mechanisms of SF and strategies for its successful management. Topics: Aged, 80 and over; Angina Pectoris; Angioplasty, Balloon, Coronary; Coronary Restenosis; Drug-Eluting Stents; Humans; Immunosuppressive Agents; Male; Middle Aged; Myocardial Infarction; Prosthesis Failure; Sirolimus | 2013 |
SORT OUT V: a new episode in the DES wars.
Topics: Absorbable Implants; Acute Coronary Syndrome; Coated Materials, Biocompatible; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Sirolimus | 2013 |
An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9.
Tissue coverage and strut apposition of drug eluting stents (DES), which can be assessed with optical coherence tomography (OCT), may be associated with late stent thrombosis (LST).. Prospective observational angiographic and OCT follow-up at 6 months post-implantation of a biolimus-A9 eluting stent (BES) vs. a paclitaxel eluting stent (PES), with biodegradable polymer carriers. The primary outcome was the percent difference of uncovered struts between BESs and PESs.. A maximum likelihood model was used for analysis, to account for data clustering. Sixteen patients were treated with BES (28 lesions/4530 struts) and 16 with PES (23 lesions/4450 struts). Overall, BESs compared to PESs had more uncovered [0.41% vs. 0.21%, difference estimate (DE) 0.2 (95% CI, 0.06-0.34), p=0.006], malapposed [0.18% vs. 0.04%, DE 0.14 (95% CI 0.05-0.23), p=0.003], uncovered and malapposed [0.08% vs. 0.026%, DE 0.057 (95% CI 0.015-0.1), p=0.01] and protruding struts [0.23% vs. 0.04%, DE 0.185 (95% CI 0.1-0.27), p<0.001], and significantly lower neointimal thickness (59.3 ± 28.2 μm vs. 201.7 ± 97.5, p<0.001). None of the BESs was totally covered with neointima, in contrast to 5 (21.7%) PESs (p=0.01). Thrombus was detected in 1 (3.6%) BES and 5 (21.7%) PESs (p=0.05); however, no patient experienced clinical stent thrombosis.. Between two stents with biodegradable polymer, OCT demonstrated that BESs had more uncovered and malapposed struts compared to PESs at 6 months. This difference might be partly attributed to the more potent antiproliferative properties of biolimus-A9; however, its impact on clinical outcome and on the risk of LST is yet to be determined. Topics: Absorbable Implants; Aged; Coronary Artery Disease; Drug Carriers; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Paclitaxel; Polymers; Prospective Studies; Radiography; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2012 |
In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.
To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.. Rabbits were fed with 1% cholesterol diet (n = 14) for 14 days, both iliac arteries were balloon denuded and radiated, and then rabbits were switched to 0.15% cholesterol diet. After 4 weeks, BF (n = 8), BMF (n = 8), and BMS (n = 8) were deployed in denuded and radiated areas. Four weeks later animals were euthanized, arterial segments were processed for morphometry.. The neointimal area in vessels implanted with BF stents was significantly less than that seen in vessels implanted with BMS (0.90 mm(2) ± 0.14 vs. 1.29 mm(2) ± 0.23, P <0.01). Percent fibrin and fibrin score were higher with BMF stents compared to BMS (P <0.03 and <0.04) and giant cell number was significantly higher with both BMF and BF stents (P < 0.01 for both). Percent endothelialization was significantly higher and % uncovered struts were lower with BMS compared to either BMF or BF stents (P < 0.05 for both).. This study demonstrates that compared to BMS, BF stents significantly decreased neointimal hyperplasia. Topics: Absorbable Implants; Angioplasty, Balloon; Animals; Atherosclerosis; Cardiovascular Agents; Constriction, Pathologic; Disease Models, Animal; Drug-Eluting Stents; Fibrin; Hypercholesterolemia; Hyperplasia; Iliac Artery; Inflammation; Male; Metals; Neointima; Plaque, Atherosclerotic; Polymers; Prosthesis Design; Rabbits; Sirolimus; Stents; Time Factors | 2012 |
Clinical performance of a drug-eluting stent with a biodegradable polymer in an unselected patient population: the NOBORI 2 study.
Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting.. A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5).. The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions. Topics: Absorbable Implants; Aged; Analysis of Variance; Angioplasty, Balloon, Coronary; Asia; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Europe; Female; Guideline Adherence; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Practice Guidelines as Topic; Product Labeling; Prospective Studies; Prosthesis Design; Registries; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2012 |
Delamination of abluminal polymer of biolimus-eluting stent.
Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Stenosis; Drug-Eluting Stents; Humans; Male; Microscopy, Electron, Scanning; Polymers; Prosthesis Design; Severity of Illness Index; Sirolimus; Treatment Outcome; Vascular Calcification | 2012 |
Limus is not limus--a proposal to adjust terminology in the context of drug-eluting stents.
Topics: Drug-Eluting Stents; Everolimus; Humans; Sirolimus; Terminology as Topic | 2012 |
Nobori stent shows less vascular inflammation and early recovery of endothelial function compared with Cypher stent.
The current study sought to examine inflammation at the stented segments of Nobori (Terumo Corporation, Tokyo, Japan) and Cypher (Cordis, Miami, Florida) drug-eluting stents (DES), as well as free radical production and endothelial function of the adjacent nonstented segments in a pig coronary model.. Nobori is a novel DES, incorporating a biolimus A9-eluting biodegradable polymer coated only on the abluminal surface of the stent. These unique features may favorably affect inflammation and endothelial function, as compared to the currently marketed DES. Presently, pre-clinical data on direct comparison of the various generations of DES are not available.. A total of 18 DES were implanted in pig coronary arteries and subsequently explanted at 1 month. Stented segments were assessed by angiography and histology. Ex vivo vasomotor function and superoxide production in segments proximal and distal to the stent were determined. The vasoconstriction, endothelial-dependent relaxation, and endothelial-independent relaxation of proximal and distal nonstented segments were measured.. Histological evaluation revealed lower inflammatory response with Nobori than with Cypher DES. There is trend for lower angiographic percentage diameter stenosis in Nobori versus Cypher groups (p = 0.054). There was increased endothelium-dependent relaxation, decreased endothelin-1-mediated contraction, and less superoxide production in the vessel segments proximal and distal to Nobori versus Cypher stents.. Our data show significantly lower inflammatory response in the stented segments, and rapid recovery of endothelial function of peristent segments in the Nobori group compared with Cypher DES group at 1 month in porcine coronary artery model. Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Dose-Response Relationship, Drug; Drug-Eluting Stents; Endothelium, Vascular; Inflammation; Japan; Models, Animal; Prosthesis Design; Recovery of Function; Sirolimus; Superoxides; Sus scrofa; Time Factors; Vasoconstriction; Vasoconstrictor Agents; Vasodilation; Vasodilator Agents | 2012 |
New-generation drug-eluting stents for patients with myocardial infarction.
Topics: Absorbable Implants; Drug-Eluting Stents; Female; Humans; Male; Myocardial Infarction; Myocardial Reperfusion; Sirolimus | 2012 |
Vascular responses to a biodegradable polymer (polylactic acid) based biolimus A9-eluting stent in porcine models.
The time-dependent changes in endothelial and healing properties of coronary arteries implanted with a biodegradable polymer-based biolimus A9-eluting stent (BioPol-BES) have not been investigated. We evaluated the short-term and the long-term in vivo response of BioPol-BES, as compared to a permanent polymer-based sirolimus-eluting stent (PermPol-SES), and a bare metal stent (BMS).. Overlapping stents were placed in 33 swine (n=11 for BES, SES, and BMS, respectively) for two and four weeks and single stents in 30 miniature pigs (n=18 for BES, n=9 for SES, n=3 for BMS) for three, nine and 15-month evaluations. The vessel patency, arterial healing and endothelialisation were assessed by angiography, histopathology and scanning electron microscopy. At four weeks, the endothelialisation at overlapping stent regions was greater with BioPol-BES (87.8±3.7%) and BMSs (98.0±0.4%) than with PermPol-SES (66.4±3.2%). The inflammation score in vessels implanted with single BioPol-BES increased slightly from three to 15 months (0.00±0.00 to 0.28±0.14), while this increase was more pronounced with PermPol-SES (0.11±0.07 to 1.56±0.68). Compared to BMS moderate lymphocyte infiltration was seen with BioPol-BES, and marked granulomatous formation with PermPol-SES.. The level of endothelial coverage in BioPol-BES was comparable to BMS at four weeks, with no significant increase of inflammatory reaction up to 15 months. Topics: Angioplasty, Balloon; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Endothelial Cells; Granuloma; Inflammation; Lactic Acid; Lymphocytes; Metals; Microscopy, Electron, Scanning; Models, Animal; Polyesters; Polymers; Prosthesis Design; Sirolimus; Swine; Swine, Miniature; Time Factors; Ultrasonography; Vascular Patency; Wound Healing | 2012 |
Bioresorbable polymers: a temporary solution?
Topics: Cardiovascular Agents; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Percutaneous Coronary Intervention; Sirolimus | 2012 |
Biolimus-eluting biodegradable polymer-coated stent versus bare metal stent in acute ST-elevation and non-ST elevation myocardial infarction: Justification for biodegradable polymer-coated stent in acute coronary syndrome (JANICE) registry.
We evaluated the efficacy and safety of a biolimus- eluting biodegradable polymer-coated stent (BES) in patients with ST-segment elevation and non ST-segment elevation acute myocardial infarction (AMI).. This was an observational study involving a single centre patient registry. We compared the rates of cardiac death, myocardial infarction, target vessel revascularization (TVR) and composite end point of cardiac death and myocardial infarction at 24 months in 106 patients who received BES versus 94 patients who received an otherwise similar bare metal stent (BMS) during percutaneous coronary intervention for AMI. There was no significant difference in the rate of cardiac death (0.9% versus 7.4%; P = 0.09), myocardial infarction (4.7% versus 3.2%; P = 0.69), stent thrombosis (0.9% versus 3.2%; P = 0.30) or cardiac death and myocardial infarction (5.7% versus 10.6%; P = 0.30) between the two groups. The rate of TVR was significantly higher in the BMS group (1.9% versus 8.5%; P = 0.04), with patients receiving BMS being four times more likely to require TVR.. The use of BES in selected patients with AMI appears to be safe and is associated with significantly reduced rate of TVR, when compared with an otherwise similar BMS. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Anti-Bacterial Agents; Death; Drug-Eluting Stents; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Observation; Polymers; Registries; Retrospective Studies; Safety; Sirolimus; Stents; Treatment Outcome | 2011 |
Comparison of pharmacokinetics of the limus-eluting stents in Japanese patients.
The aim of this study was to compare the pharmacokinetics of the four limus-eluting stents used in Japanese patients.. There are presently no reports comparing human pharmacokinetics among drug-eluting stents (DESs).. We retrospectively analyzed data from pharmacokinetic studies of patients implanted with an 18-mm DES: Cypher stent (sirolimus, n = 10), Endeavor stent (zotarolimus, n = 7), Xience V stent (everolimus, n = 6), and Nobori stent (biolimus A9, n = 10), in multicenter trials of Japan. Total drug doses of the Cypher stent, Endeavor stent, Xience V stent, and Nobori stent were 150, 180, 88, and 293 μg, respectively. Drug concentrations were measured in serial whole blood samples after implantation and the pharmacokinetics were analyzed.. Mean peak drug levels were 0.86 ng mL(-1) for Cypher, 1.80 ng mL(-1) for Endeavor, 0.50 ng mL(-1) for Xience V, and 0.09 ng mL(-1) for Nobori. After adjustment for the loaded dose, mean peak drug levels of the Cypher and Xience V stents were similar (0.0057 ng mL(-1) μg(-1) each) while the Endeavor (0.0100 ng mL(-1) μg(-1)) was higher, and the Nobori (0.0003 ng mL(-1) μg(-1)) was lower, compared with the Cypher and Xience V stents. The other pharmacokinetic parameters of four DESs differed according to characteristics of the coated drug. The systemic exposure of biolimus A9 was much lower than that of the other DESs studied.. In Japanese patients, systemic exposure was low, regardless of the type of limus drug eluted from the stents; but specific pharmacokinetic activities were varied according to the drug characteristics, concentration, and DES design. Topics: Aged; Analysis of Variance; Asian People; Cardiovascular Agents; Clinical Trials as Topic; Drug-Eluting Stents; Everolimus; Female; Humans; Japan; Linear Models; Male; Middle Aged; Models, Biological; Multicenter Studies as Topic; Prosthesis Design; Retrospective Studies; Sirolimus | 2011 |
Polymer drug-eluting stents: is the future biodegradable?
Topics: Absorbable Implants; Coronary Artery Disease; Drug-Eluting Stents; Humans; Polymers; Sirolimus | 2011 |
Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: comparative sequential assessment with optical coherence tomography until complete resorption of the polymer.
Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.. The LEADERS trial compared the performance of BES with that of SES. Patients were randomly allocated to a sequential angiographic follow-up, including OCT in selected sites, at 9 and 24 months. Struts coverage was compared using Bayesian hierarchical models as the primary outcome for the OCT substudy.. Fifty-six patients (26 BES, 30 SES) were enrolled in the OCT substudy. Twenty-one patients (10 BES, 11 SES) agreed to perform a second OCT follow-up at 24 months. Eleven lesions and 12 stents were analyzed sequentially in the BES group (2,455 struts at 9 months, 2,131 struts at 24 months) and 11 lesions and 18 stents in the SES group (3,421 struts at 9 months, 4,170 struts at 24 months). The previously reported advantage of BES over SES in terms of better strut coverage at 9 months was followed by improvement in coverage of the SES, resulting in identical coverage in both BES and SES at 24 months: 1.5% versus 1.8% uncovered struts, difference -0.2%, 95% credibility interval, -3.2% to 2.6%, P = .84.. More complete strut coverage of BES as compared with SES at 9 months was followed by improvement of coverage in SES between 9 and 24 months and a similar long-term coverage in both stent types at 24 months. Topics: Adult; Angioplasty, Balloon, Coronary; Case-Control Studies; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Polymers; Randomized Controlled Trials as Topic; Serum Albumin; Serum Albumin, Human; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2011 |
Long-term complication after LM bifurcation treatment.
Two months after left anterior descending (LAD) artery and left circumflex (LCx) artery bare metal stent implantation, a proliferative subocclusive in-stent restenosis in LCx coronary with severe LM coronary (LM) involvement developed. The present clinical case describes a simplified strategy for unprotected LM percutaneous coronary intervention using two bioabsorbable biolimus-eluting stents without involvement of the LAD coronary using an "L" technique. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Male; Metals; Middle Aged; Prosthesis Design; Sirolimus; Stents; Time Factors; Treatment Outcome | 2010 |
Percutaneous UPLM revascularisation: the time has come.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Metals; Prosthesis Design; Sirolimus; Stents; Time Factors; Treatment Outcome | 2010 |
Clinical studies with sirolimus, zotarolimus, everolimus, and biolimus A9 drug-eluting stent systems.
The introduction of the drug-eluting stent (DES) has revolutionized the field of interventional cardiology during the past decade. Initial pivotal randomized clinical trials showed a large reduction in restenosis rates and the need for repeat intervention with DES compared with bare-metal stents. The three main components of a DES are 1) the stent platform, 2) a coating facilitating elution of the drug (mostly a polymer), and 3) a antiproliferative/anti-inflammatory drug. Currently, two classes of drugs are widely used in DES, Taxanes, including its best-known member Paclitaxel, and Rapamycins, which include Sirolimus and its analogues such as Everolimus, Zotarolimus and Biolimus A9. The first DES to receive United States Food and Drug Administration approval was the Sirolimus-eluting stent. Recently, two other stent types eluting a Sirolimus-analogue were approved; the Zotarolimus-eluting stent and the Everolimus-eluting stent. Biolimus A9-eluting stents, using biodegradable polymers, are currently approved and marketed outside of the United States. This review article focusses on the clinical studies that have been performed with DES eluting Sirolimus or its analogues. Topics: Constriction, Pathologic; Everolimus; Humans; Sirolimus; Stents | 2010 |
The AXXESS™ self-expanding biolimus A9™ eluting stent system for coronary bifurcation lesions.
Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Humans; Materials Testing; Patient Selection; Prosthesis Design; Sirolimus; Treatment Outcome | 2010 |
Treating the left main bifurcation lesion: the "three stent solution".
Topics: Alloys; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Prosthesis Design; Sirolimus; Stents; Treatment Outcome; Ultrasonography, Interventional | 2009 |
Correlation between quantitative angiographic and intravascular ultrasound parameters in patients treated with sirolimus analogous-eluting stents.
Despite the undeniable contribution of intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA) to assess drug-eluting stent (DES) effectiveness, the way these image modalities correlate to each other and to target-lesion revascularization (TLR) after PCI, is yet to be established. Thus we sought to evaluate whether there is an acceptable correlation between QCA and IVUS after DES implantation. We analyzed 204 pts treated with DES: Zotarolimus- (126), Sirolimus- (57), and Biolimus (31) with baseline and follow-up QCA and IVUS. The correlation between QCA lumen loss (LL) and intimal hyperplasia (IH) volume obstruction by IVUS was assessed by multiple regression analysis. Two QCA parameters (in-segment diameter stenosis and in-segment LL) and one IVUS variable (in-stent volume of IH) were evaluated as quantitative surrogates of 6 month TLR. The receiver operating characteristic method with c-statistics was used to assess the ability of each surrogate endpoint to predict TLR. QCA LL correlated positively with IVUS IH volume of obstruction (r = 0.69; CI95% 0.61-0.75: P < 0.0001), independent of DES type. The 2 QCA parameters were superior to the IVUS parameter as surrogates for TLR. Of note, QCA LL (c = 0.99) correlated best with TLR, even better than percent DS. In the DES era there is a good correlation between QCA measured LL and IVUS IH volume and therefore can be used as a surrogate of DES efficacy. Topics: Coronary Angiography; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Immunosuppressive Agents; Male; Middle Aged; Prospective Studies; Regression Analysis; ROC Curve; Sirolimus; Ultrasonography, Interventional | 2009 |
In vivo evaluation of a biolimus eluting nickel titanium self expanding stent with overlapping balloon expandable drug eluting and bare metal stents in a porcine coronary model.
Long lesions and complex vessel anatomy frequently require the use of overlapping stents to treat a lesion. The purpose of this study was to evaluate the long-term effects of overlapping the Axxess Biolimus A9 eluting stent (BES) with two of the most commonly used, commercially available drug eluting stents. These stents were compared to BxVelocity bare metal (BMS) stents in a porcine coronary stent-injury model.. Nineteen juvenile farm swine, 25-35 kg in weight, 3-6 months in age were utilised. Each animal received an Axxess stent to their coronary artery as permitted by the individual animal's anatomy. A second stent, either a Cypher, sirolimus eluting stent (SES) or, a Taxus, paclitaxel eluting stent (PES), or a BxVelocity bare metal stent (BMS) were implanted in an overlapped fashion. The animals were then followed for either 28 or 180 days as specified by a randomisation scheme. At the end of each follow-up period, they were euthenised, and the vessels containing the overlapping stents were harvested, processed into histological sections, and analysed. Compared to bare metal stents, overlapped segments using DES exhibited delayed vascular healing compared to both the proximal and distal non-overlap sites at each of the follow-up time point. Overall, in the non-overlap stent segments, SES induced significantly more inflammation and neointimal hyperplasia compared to PES and BMS.. In this study of BMS and two different types of DES overlapped with the Axxess Biolimus A9 eluting stent, we found that while there was a delay in the degree of vascular healing with DES compared to BMS, the specific type of DES that was overlapped with BES did not affect the behaviour of the overlap zone in terms of most of the histomorphometric measures at 28 or 180 days. This was true whether the stent was drug eluting or bare metal. More inflammation with delayed healing was seen in the SES compared to PES and BMS. Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Hyperplasia; Inflammation; Models, Animal; Nickel; Paclitaxel; Platelet Aggregation Inhibitors; Prosthesis Design; Sirolimus; Stents; Swine; Time Factors; Titanium; Wound Healing | 2009 |
Reproducibility of quantitative optical coherence tomography for stent analysis.
To assess the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with optical coherence tomography (OCT).. Ten drug-eluting stents (244 frames, 1712 struts) imaged with OCT nine months after implantation were analysed by two independent analysts. One of the analysts repeated the analysis of five stents (120 frames, 795 struts) one week later. Offline analysis was performed with the proprietary LightLab Imaging software. The number of struts was counted and lumen and stent area contours were traced. Tissue coverage thickness was measured at 360 degrees of vessel circumference and in front of every individual strut. The number of malapposed struts was determined. There was good agreement for strut number count (Kendall's Tau-b 0.90 for inter- and 0.94 for intra- observer variability). The relative difference for lumen area, stent area and tissue coverage measurements was around 1%. There was complete inter- and intra- observer agreement for malapposed struts classification (4 out of 1708 struts, Kappa=1).. In a Corelab setting, the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with OCT is excellent. This emphasises the value of OCT as a tool for the clinical long-term assessment of stents. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Humans; Image Interpretation, Computer-Assisted; Observer Variation; Predictive Value of Tests; Prosthesis Design; Reproducibility of Results; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2009 |
Scanning electron microscopic assessment of the biodegradable coating on expanded biolimus-eluting stents.
Biodegradable coatings on drug-eluting stents (DES) may help to avoid adverse long-term effects of DES such as late/very late stent thrombosis which is partly attributed to durable polymers. As the post-expansion morphology of biodegradable coatings is greatly unknown, we investigated the polylactic acid coating on biolimus-eluting BioMatrix stents.. Scanning electron microscopy (SEM) was used to carefully examine five 3.5mm stents following expansion at 6-14atm (maximum 7% overstretch). SEM examination demonstrated only mild cracks of the coating after stent expansion at 6 atm. An increase in expansion pressure, associated with mild stent overstretch, resulted in more severe cracks. Lifting of the coating together with few sites of partial detachment of fragments was noticed after stent expansion in water at 14atm; these irregularities further increased after aggressive oversized partial postdilatation with a 5.0mm non-compliant balloon with additional secondary cracks.. SEM assessment suggests a relatively low elasticity of the biodegradable coating on BioMatrix stents. At nominal pressure, stents showed predominantly mild cracks of the coating, while cracks increased after slight overstretch. Aggressive overexpansion of the stent, such as sometimes required in left main bifurcation stenting, worsened cracks and led to some detachment of fragments of the coating in vitro. Topics: Absorbable Implants; Biosensing Techniques; Drug-Eluting Stents; Equipment Design; Humans; Immunosuppressive Agents; Microscopy, Electron, Scanning; Reproducibility of Results; Sirolimus; Water | 2009 |
Development and validation of a semi-automated assay for the highly sensitive quantification of Biolimus A9 in human whole blood using high-performance liquid chromatography-tandem mass spectrometry.
Drug-eluting stents are sustained-release intra-coronary devices that are usually coated with a few hundred micrograms of drug. Measuring the drugs that are released over weeks in order to assess human pharmacokinetics is a challenge that requires assays with high sensitivity. We developed and validated a semi-automated LC-MS/MS assay for the quantification of Biolimus A9, a proliferation signal inhibitor that was specifically developed for coating on drug-eluting stents in human EDTA blood. The only manual step was the addition of a zinc sulfate/methanol protein precipitation solution which included the internal standard. Samples were injected into the HPLC and extracted online. The assay had the following performance characteristics: range of reliable response 0.01-100 ng/mL (r(2)>0.99), inter-day accuracy (0.033 ng/mL): 111.7%, and inter-day precision: 8.6%. There was no ion suppression, matrix interferences or carry-over. Extracted samples were stable in the autosampler at +4 degrees C for at least 24 h and could undergo three freeze-thaw cycles. The assay, with a lower limit of detection of 333 fg/mL and a lower limit of quantitation of 10 pg/mL, was sufficiently sensitive and robust for quantifying Biolimus A9 in clinical trials after i.v. injection and after stent implantation. Topics: Chromatography, High Pressure Liquid; Drug-Eluting Stents; Humans; Reproducibility of Results; Sirolimus; Tandem Mass Spectrometry | 2009 |
Long-term outcome after the V stenting technique in de novo bifurcation lesions using drug-eluting stents.
To report long-term outcome data on the V technique using drug-eluting stents.. From April 2002 to December 2006, 31 consecutive patients were successfully treated with V stenting of a de novo bifurcation lesion. The technique involves the deployment of two stents in the two branches of a bifurcation, the proximal edges of the stents just touching one another. Patients exclusively received either sirolimus- (10), paclitaxel- (20) or biolimus-eluting (one) stents. On average, 1.5 +/- 0.8 stents with a total length of 26.6 +/- 17.2 mm and 1.1 +/- 0.4 stents with a total length of 18.3 +/- 7.6 mm were deployed in the distal main vessel and side branch respectively. Mean duration of follow-up was 853 +/- 553 days. Within 30 days, three patients died; two other patients had definite stent thrombosis involving the V stents, both requiring re-PCI. Beyond 30 days and within one year, there was one death and three cases of target vessel revascularisation, including one target lesion revascularisation. There were a further three deaths (one cardiac) beyond one year. Eleven patients (35.5%) had angiographic follow-up, exhibiting a binary restenosis rate of 9.1% at 203 +/- 33 days.. In this real-world cohort, late clinical events stand in accord with studies on competitive techniques, but early outcome was less encouraging, probably due to the baseline risks. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Netherlands; Paclitaxel; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Drug-eluting stents: is new necessarily better?
Topics: Absorbable Implants; Biocompatible Materials; Coronary Stenosis; Drug-Eluting Stents; Humans; Metals; Polymers; Sirolimus; Thrombosis | 2008 |
Interference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses.
There is evidence that endothelial coverage of drug-eluting stents might be delayed or absent, a risk factor for late thrombotic events. We studied the effects of different drug-polymer-device iterations on endothelium-dependent coronary vasomotion. Systemic markers of endothelial inflammation were correlated with coronary vasomotor changes.. Patients with paclitaxel-eluting stents (n=11), sirolimus-eluting stents (n=21), biolimus A9-eluting stents (n=28), zotarolimus-eluting stents (n=10), and bare-metal stents (n=13) were studied 10, 9, 9, 9, and 12 months after implantation, respectively. Endothelium-dependent coronary vasomotion was tested proximally and distally to the stent and at a reference vessel segment during atrial pacing at increasing heart rates by quantitative coronary angiography. Indexes of platelet-monocyte binding and other biomarkers were studied in a subgroup of 19 patients. The baseline characteristics and hemodynamics of the patients in the different stent groups were comparable. Significant differences were observed across the 5 stent groups, concerning the vasomotion of segments proximal (P=0.006) and distal (P=0.003) to the stent. Normal vasomotion (vasodilatation) was maintained in the biolimus A9-eluting stent, zotarolimus-eluting stent, and bare-metal stent groups, whereas vasoconstriction was observed in the sirolimus-eluting stent and paclitaxel-eluting stent groups. Platelet-monocyte binding in whole blood showed a significant inverse correlation with vasomotion in reference but not in segments adjacent to the stent (r=-0.57; P=0.01).. Paclitaxel-eluting stents and sirolimus-eluting stents seem to cause endothelial dysfunction of the implanted vessel, whereas biolimus A9-eluting stents and zotarolimus-eluting stents behave more closely to bare-metal stents, with preserved endothelial vasomotor response. Coronary vasoconstriction was not associated with detectable systemic endothelial activation. Topics: Blood Platelets; Cardiovascular Agents; Cell Aggregation; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Endothelium, Vascular; Female; Humans; Male; Middle Aged; Monocytes; P-Selectin; Paclitaxel; Sirolimus; Vasoconstriction; Vasodilation | 2008 |
Results of percutaneous coronary intervention of the unprotected left main coronary artery in 143 patients and comparison of 30-day mortality to results of coronary artery bypass grafting.
Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery (LMCA) is controversial. In 143 patients who underwent PCI of the unprotected LMCA, 30-day mortality was compared with predicted cumulative risk-adjusted perioperative surgical mortality based on logistic European System for Cardiac Operative Risk Evaluation. One-year clinical follow-up was completed in all patients. The overall major adverse cardiac event rate at 1 year was 34.3%, reflecting the high-risk profile of the patient population. Twelve patients (8%) experienced an acute myocardial infarction and 16 (11%) underwent target lesion revascularization. In 31 patients (22%) who died during the first year, median logistic European System for Cardiac Operative Risk Evaluation was 30%. Calculated RRs showed significantly lower 30-day mortality using PCI compared with predicted surgical mortality (RR 0.54, 95% confidence interval 0.31 to 0.86). Angiographic follow-up in 90 of the 118 patients alive at 6 months showed binary restenosis of 6% in patients treated with drug-eluting stents versus 29% in patients receiving bare-metal stents (p < or =0.01). In conclusion, PCI for unprotected LMCA disease was associated with acceptable short- and medium-term outcomes in patients at low to intermediate risk of bypass surgery. Mortality remains high in very high-risk patients unsuitable for surgery. However, in selected indications, PCI of the LMCA can offer an alternative to surgery, especially when using drug-eluting stents. Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Angioplasty, Balloon, Coronary; Coronary Artery Bypass; Coronary Artery Disease; Coronary Restenosis; Female; Humans; Male; Myocardial Infarction; Outcome Assessment, Health Care; Retreatment; Risk Adjustment; Sirolimus; Stents | 2008 |
Bifurcation stenting with a dedicated biolimus-eluting stent: X-ray visual enhancement of the final angiographic result with "StentBoost Subtract".
A 51 year-old man underwent percutaneous coronary intervention of a significant "true" bifurcation lesion involving the proximal left anterior descendens (LAD) artery and an important first diagonal branch with a dedicated bifurcation stent, which is a conical self-expandable biolimus-eluting stent with a "flared" distal part allowing for optimal scaffolding of the carina of the bifurcation, and two additional sirolimus-eluting stents, deployed with the V-stenting technique, one in the LAD and one in the diagonal branch, in overlap with the distal part of the "flared" biolimus-eluting stent. An X-ray enhancing visualization technique, "StentBoost Subtract," was used to obtain an improved visualization of the stent in relation to the corresponding vessel lumen and revealed good expansion of all the stents and good apposition to the vessel wall. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cineangiography; Contrast Media; Coronary Angiography; Coronary Artery Disease; Humans; Male; Middle Aged; Prosthesis Design; Radiographic Image Interpretation, Computer-Assisted; Radiography, Interventional; Severity of Illness Index; Sirolimus; Stents | 2007 |
Six-month clinical and angiographic results of a dedicated drug-eluting stent for the treatment of coronary bifurcation narrowings.
Percutaneous intervention for coronary bifurcation lesions has been associated with increased clinical complication rates compared with nonbifurcation lesions, primarily as a result of restenosis. Therefore, there is a need for new techniques. The purpose of this study was to evaluate a new drug-eluting stent and implantation technique for the treatment of de novo coronary bifurcation lesions. The Axxess Plus trial was a prospective multicenter single-arm study that enrolled 139 patients. Each patient received a self-expanding, conically shaped nickel-titanium Axxess Plus biolimus A9-eluting stent at the level of the carina. Depending on the lesion anatomy, additional nonstudy stents were placed distally if necessary. Clinical and angiographic follow-up were scheduled at 6 months after the procedure. The overall rate of target lesion revascularization was 7.5% at 6 months. A mean of 2.4 stents were implanted per patient; 51.2% of patients received a stent to the side branch, 29.4% received balloon angioplasty only, and 20.6% of side branches were not treated. In-stent late loss in the Axxess stents was 0.09 mm. Incidences of angiographic in-stent restenosis were 7.1% in the parent vessel stents and 9.2% in the group receiving stents in the side branch (7.9% excluding bare metal stents placed distal to the Axxess stent), compared with 25% for balloon angioplasty treatment and 12% for no treatment. Late stent thrombosis was observed in 3 cases, 2 of which were associated with confirmed premature cessation of antiplatelet therapy. In conclusion, the Axxess Plus conical stent effectively treats bifurcation lesions alone or in conjunction with other drug-eluting stents. Topics: Aged; Antibiotics, Antineoplastic; Blood Vessel Prosthesis Implantation; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Female; Humans; Male; Middle Aged; Prospective Studies; Sirolimus; Stents | 2007 |