silicon has been researched along with 5-hydroxymethyluracil* in 1 studies
1 other study(ies) available for silicon and 5-hydroxymethyluracil
Article | Year |
---|---|
Gas chromatographic-mass spectrometric determination of 5-hydroxymethyluracil in human urine by stable isotope dilution.
A method for the determination of 5-hydroxymethyluracil in urine is described. 5-Hydroxymethyluracil was extracted by reversed-phase chromatography and quantified by gas chromatography-mass spectrometry as tert.-butyldimethylsilyl derivative. Since natural 5-hydroxymethyluracil contained ca. 22% of M + 2 species, an internal standard consisting of [1,3-15N2,5-2H2]hydroxymethyluracil was used to correct losses during extraction, evaporation and derivatization. Between-run precision of this method was 7.79%, and concentrations as low as 1.87 nM could be measured. This sensitivity and precision could not be obtained with trimethylsilyl derivatives. Topics: Gas Chromatography-Mass Spectrometry; Humans; Indicator Dilution Techniques; Organosilicon Compounds; Pentoxyl; Silicon | 1993 |