Page last updated: 2024-09-02

s-benzyl-n-acetyl-l-cysteine and s-phenyl-n-acetylcysteine

s-benzyl-n-acetyl-l-cysteine has been researched along with s-phenyl-n-acetylcysteine in 11 studies

Compound Research Comparison

Studies
(s-benzyl-n-acetyl-l-cysteine)
Trials
(s-benzyl-n-acetyl-l-cysteine)
Recent Studies (post-2010)
(s-benzyl-n-acetyl-l-cysteine)
Studies
(s-phenyl-n-acetylcysteine)
Trials
(s-phenyl-n-acetylcysteine)
Recent Studies (post-2010) (s-phenyl-n-acetylcysteine)
3608137247

Research

Studies (11)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's1 (9.09)18.2507
2000's4 (36.36)29.6817
2010's5 (45.45)24.3611
2020's1 (9.09)2.80

Authors

AuthorsStudies
Dehnen, W; Dunemann, L; Einig, T1
Brambilla, G; Buratti, M; Colombi, A; Fustinoni, S; Pellegrino, O; Pulviremti, S1
Accorsi, A; Barbieri, A; Roda, A; Sabatini, L; Violante, FS1
Barbieri, A; Indiveri, P; Mattioli, S; Sabatini, L; Violante, FS1
Alt, A; Kraus, T; Musiol, A; Schettgen, T1
Barbieri, A; Bartolucci, GB; Basso, A; Carrieri, M; D'Errico, MN; Doria, D; Drago, I; Fracasso, ME; Lovreglio, P; Sabatini, L; Soleo, L; Violante, FS1
B'Hymer, C1
B'Hymer, C; Butler, MA; Cheever, KL; Clark, JC; Gibson, R; Kesner, JS; Krieg, E; Toennis, CA1
Chen, L; Chen, W; Deng, Q; Gao, C; He, Z; Huang, Z; Li, D; Li, J; Liu, L; Qin, F; Sun, Q; Sun, X; Tang, H; Wang, F; Wang, Q; Wang, S; Xiao, Y; Zeng, X; Zhang, B; Zhang, X1
Jin, Y; Li, L; Shuang, Y; Wang, H1
Olsen, R; Rosting, C1

Other Studies

11 other study(ies) available for s-benzyl-n-acetyl-l-cysteine and s-phenyl-n-acetylcysteine

ArticleYear
Sensitive gas chromatographic method for determination of mercapturic acids in human urine.
    Journal of chromatography. B, Biomedical applications, 1996, Dec-13, Volume: 687, Issue:2

    Topics: Acetylcysteine; Chromatography, Gas; Environmental Exposure; Humans; Occupational Exposure; Reproducibility of Results; Sensitivity and Specificity; Smoking

1996
Determination of monobromobimane derivatives of phenylmercapturic and benzylmercapturic acids in urine by high-performance liquid chromatography and fluorimetry.
    Journal of chromatography. B, Biomedical sciences and applications, 2001, Feb-25, Volume: 751, Issue:2

    Topics: Acetylcysteine; Bridged Bicyclo Compounds; Calibration; Chromatography, High Pressure Liquid; Fluorometry; Humans; Reproducibility of Results

2001
Simultaneous determination of t,t-muconic, S-phenylmercapturic and S-benzylmercapturic acids in urine by a rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry method.
    Rapid communications in mass spectrometry : RCM, 2004, Volume: 18, Issue:17

    Topics: Acetylcysteine; Chromatography, High Pressure Liquid; Environmental Monitoring; Humans; Reproducibility of Results; Sorbic Acid; Spectrometry, Mass, Electrospray Ionization

2004
Validation of an HPLC-MS/MS method for the simultaneous determination of phenylmercapturic acid, benzylmercapturic acid and o-methylbenzyl mercapturic acid in urine as biomarkers of exposure to benzene, toluene and xylenes.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2008, Feb-15, Volume: 863, Issue:1

    Topics: Acetylcysteine; Benzene; Biomarkers; Calibration; Chromatography, High Pressure Liquid; Humans; Indicators and Reagents; Occupational Exposure; Quality Control; Reproducibility of Results; Solvents; Spectrometry, Mass, Electrospray Ionization; Toluene; Xylenes

2008
Fast determination of urinary S-phenylmercapturic acid (S-PMA) and S-benzylmercapturic acid (S-BMA) by column-switching liquid chromatography-tandem mass spectrometry.
    Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2008, Mar-01, Volume: 863, Issue:2

    Topics: Acetylcysteine; Adult; Automation; Biomarkers; Calibration; Chromatography, Liquid; Environmental Exposure; Environmental Monitoring; Female; Humans; Male; Quality Control; Reference Standards; Reproducibility of Results; Sensitivity and Specificity; Smoking; Spectrometry, Mass, Electrospray Ionization; Tandem Mass Spectrometry

2008
Validity of new biomarkers of internal dose for use in the biological monitoring of occupational and environmental exposure to low concentrations of benzene and toluene.
    International archives of occupational and environmental health, 2010, Volume: 83, Issue:3

    Topics: Acetylcysteine; Adult; Benzene Derivatives; Biomarkers; Environmental Exposure; Environmental Monitoring; Humans; Male; Middle Aged; Occupational Exposure; Toluene

2010
Validation of an HPLC-MS-MS method for the determination of urinary S-benzylmercapturic acid and S-phenylmercapturic acid.
    Journal of chromatographic science, 2011, Volume: 49, Issue:7

    Topics: Acetylcysteine; Chromatography, High Pressure Liquid; Humans; Tandem Mass Spectrometry

2011
Evaluation and comparison of urinary metabolic biomarkers of exposure for the jet fuel JP-8.
    Journal of toxicology and environmental health. Part A, 2012, Volume: 75, Issue:11

    Topics: Acetates; Acetylcysteine; Adult; Airports; Biomarkers; Chromatography, High Pressure Liquid; Creatinine; Dose-Response Relationship, Drug; Gas Chromatography-Mass Spectrometry; Humans; Hydrocarbons; Limit of Detection; Military Facilities; Military Personnel; Occupational Exposure; Petroleum; Tandem Mass Spectrometry; United States; Urinalysis

2012
MGMT hypomethylation is associated with DNA damage in workers exposed to low-dose benzene.
    Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals, 2017, Volume: 22, Issue:5

    Topics: Acetylcysteine; Adult; Benzene; Biomarkers; Case-Control Studies; DNA Damage; DNA Methylation; DNA Modification Methylases; DNA Repair Enzymes; Epigenesis, Genetic; Female; Humans; Male; O(6)-Methylguanine-DNA Methyltransferase; Occupational Exposure; Oil and Gas Industry; Tumor Suppressor Proteins

2017
Preparation of a new benzylureido-β-cyclodextrin-based column and its application for the determination of phenylmercapturic acid and benzylmercapturic acid enantiomers in human urine by LC/MS/MS.
    Analytical and bioanalytical chemistry, 2019, Volume: 411, Issue:21

    Topics: Acetylcysteine; beta-Cyclodextrins; Chromatography, Liquid; Humans; Limit of Detection; Reference Standards; Reproducibility of Results; Stereoisomerism; Tandem Mass Spectrometry

2019
Biomonitoring of the benzene metabolite s-phenylmercapturic acid and the toluene metabolite s-benzylmercapturic acid in urine from firefighters.
    Toxicology letters, 2020, Sep-01, Volume: 329

    Topics: Acetylcysteine; Air; Benzene; Firefighters; Humans; Male; Occupational Exposure; Time Factors; Toluene

2020