rhodium has been researched along with tungsten in 24 studies
Timeframe | Studies, this research(%) | All Research% |
---|---|---|
pre-1990 | 2 (8.33) | 18.7374 |
1990's | 5 (20.83) | 18.2507 |
2000's | 7 (29.17) | 29.6817 |
2010's | 6 (25.00) | 24.3611 |
2020's | 4 (16.67) | 2.80 |
Authors | Studies |
---|---|
Depeursinge, C; Desponds, L; Grecescu, M; Hessler, C; Samiri, A; Valley, JF | 1 |
Crandall, PH; Dymond, AM; Jurist, JM; Kaechele, LE | 1 |
Beaman, SA; Lillicrap, SC | 1 |
Breiter, N; Funke, M; Grabbe, E; Hermann, KP; Moritz, J; Müller, D | 1 |
Bassett, LW; DeBruhl, ND; Kimme-Smith, CM; McCombs, MM; Sayre, JW | 1 |
Boone, JM; Fewell, TR; Jennings, RJ | 1 |
Blough, MM; Payne, WH; Terry, JA; Waggener, RG | 1 |
Carlsson, GA; Castellano, IA; Dance, DR; Sandborg, M; Skinner, CL; Thilander, AK | 1 |
Kharrati, H; Zarrad, B | 1 |
Bruhn, CG; Huerta, VN; Neira, JY | 1 |
Bosmans, H; Marchal, G; Toroi, P; van Ongeval, C; Young, KC; Zanca, F | 1 |
Bautz, WA; Böhner, C; Dassel, MS; Hermann, KP; Lell, M; Schulz-Wendtland, R; Wenkel, E | 1 |
D'Orsi, CJ; Sechopoulosa, I | 1 |
Mertelmeier, T; Uhlenbrock, DF | 1 |
Kudo, A; Miseki, Y | 1 |
Boone, JM; Hernandez, A; Nosratieh, A; Seibert, JA; Shen, SZ; Yaffe, MJ | 1 |
Hao, Y; Khan, MU; Li, H; Liu, H; Wang, L; Zeng, J; Zhang, W | 1 |
Alkhalifah, K; Alsaeed, R; Brindabhan, A | 1 |
Borg, M | 1 |
Bai, J; Li, Y; Liu, F; Liu, Y; Lu, G; Sun, P; Wang, H; Yan, X | 1 |
Baldelli, P; Keavey, E; Manley, M; Phelan, N; Power, G | 1 |
Costa, PR; Mariano, L; Santoro-Fernandes, V; Santos, JC; Vanin, VR | 1 |
Büermann, L; Hilgers, G; Ketelhut, S | 1 |
Hernandez-Guzman, A; Massillon-Jl, G; Moreno-Ramírez, A | 1 |
24 other study(ies) available for rhodium and tungsten
Article | Year |
---|---|
Influence of anode and filter material on image quality and glandular dose for screen-film mammography.
Topics: Electrodes; Filtration; Mammography; Molybdenum; Radiation Dosage; Rhodium; Tungsten; X-Ray Intensifying Screens | 1991 |
Brain tissue reaction to some chronically implanted metals.
Topics: Animals; Brain; Cats; Electrodes; Equipment and Supplies; Gold; Metals; Molybdenum; Nickel; Palladium; Platinum; Prostheses and Implants; Rhodium; Tungsten | 1970 |
Optimum x-ray spectra for mammography.
Topics: Aluminum; Breast; Breast Neoplasms; Female; Humans; Mammography; Molybdenum; Palladium; Rhodium; Tungsten | 1982 |
[A bimetal anode with tungsten or rhodium? Comparative studies on image quality and dosage requirement in mammography].
Topics: Electrodes; Equipment Design; Evaluation Studies as Topic; Female; Filtration; Humans; Mammography; Molybdenum; Phantoms, Imaging; Quality Control; Radiation Dosage; Radiographic Image Enhancement; Rhodium; Tungsten; X-Ray Intensifying Screens | 1995 |
Breast calcification and mass detection with mammographic anode-filter combinations of molybdenum, tungsten, and rhodium.
Topics: Aged; Breast Neoplasms; Cadaver; Calcinosis; Equipment Design; Female; Filtration; Humans; Mammography; Molybdenum; Observer Variation; Radiation Dosage; Radiographic Image Enhancement; Rhodium; Tungsten; X-Ray Intensifying Screens | 1997 |
Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography.
Topics: Aluminum; Calibration; Computer Simulation; Electrodes; Female; Humans; Mammography; Models, Theoretical; Molybdenum; Phantoms, Imaging; Radiographic Image Interpretation, Computer-Assisted; Rhodium; Tungsten | 1997 |
Calculated mammographic spectra confirmed with attenuation curves for molybdenum, rhodium, and tungsten targets.
Topics: Biophysical Phenomena; Biophysics; Female; Humans; Mammography; Models, Theoretical; Molybdenum; Rhodium; Scattering, Radiation; Software; Spectrum Analysis; Technology, Radiologic; Tungsten | 1998 |
Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study.
Topics: Aluminum; Breast Diseases; Electrodes; Female; Humans; Mammography; Molybdenum; Monte Carlo Method; Phantoms, Imaging; Radiation Dosage; Radiation Protection; Rhodium; Sensitivity and Specificity; Spectrum Analysis; Tungsten | 2000 |
Computation of beam quality parameters for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations in mammography.
Topics: Aluminum; Computer Simulation; Humans; Mammography; Models, Statistical; Molybdenum; Photons; Radiometry; Rhodium; Software; Tungsten; X-Rays | 2003 |
Chemical modifiers in arsenic determination in biological materials by tungsten coil electrothermal atomic absorption spectrometry.
Topics: Animals; Arsenic; Bivalvia; Hair; Humans; Iridium; Palladium; Rhodium; Spectrophotometry, Atomic; Temperature; Tungsten | 2004 |
Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system.
Topics: Filtration; Humans; Image Processing, Computer-Assisted; Mammography; Molybdenum; Phantoms, Imaging; Radiation Dosage; Radiographic Image Enhancement; Rhodium; Selenium; Tungsten | 2007 |
[Experimental investigations for dose reduction by optimizing the radiation quality for digital mammography with an a-Se detector].
Topics: Female; Humans; Mammography; Molybdenum; Phantoms, Imaging; Radiation Dosage; Radiographic Image Enhancement; Rhodium; Sensitivity and Specificity; Tungsten | 2007 |
Glandular radiation dose in tomosynthesis of the breast using tungsten targets.
Topics: Breast Neoplasms; Computer Simulation; Humans; Models, Statistical; Molybdenum; Monte Carlo Method; Radiation Oncology; Radiographic Image Enhancement; Radiometry; Radiotherapy; Reproducibility of Results; Rhodium; Software; Tungsten; X-Rays | 2008 |
Comparison of anode/filter combinations in digital mammography with respect to the average glandular dose.
Topics: Aged; Breast; Female; Filtration; Humans; Mammography; Middle Aged; Molybdenum; Radiation Dosage; Radiographic Image Enhancement; Radiometry; Rhodium; Selenium; Sensitivity and Specificity; Tungsten | 2009 |
Water splitting over new niobate photocatalysts with tungsten-bronze-type structure and effect of transition metal-doping.
Topics: Alloys; Barium; Catalysis; Hydrogen; Lanthanoid Series Elements; Light; Nickel; Niobium; Oxides; Oxygen; Photochemistry; Potassium; Rhodium; Spectrophotometry; Strontium; Transition Elements; Tungsten; Water | 2011 |
Mean glandular dose coefficients (D(g)N) for x-ray spectra used in contemporary breast imaging systems.
Topics: Algorithms; Breast; Female; Humans; Mammography; Models, Biological; Molybdenum; Monte Carlo Method; Radiation Dosage; Radiographic Image Enhancement; Rhodium; Spectrometry, X-Ray Emission; Tungsten; X-Rays | 2015 |
Integration of Quantum Confinement and Alloy Effect to Modulate Electronic Properties of RhW Nanocrystals for Improved Catalytic Performance toward CO
Topics: Adsorption; Alloys; Carbon Dioxide; Catalysis; Electronics; Hydrogen; Hydrogenation; Methanol; Models, Theoretical; Nanoparticles; Particle Size; Rhodium; Surface Properties; Tungsten | 2017 |
Effect of exposure factors on image quality in screening mammography.
Topics: Breast Neoplasms; Female; Humans; Kuwait; Mammography; Phantoms, Imaging; Radiographic Image Enhancement; Rhodium; Silver; Tungsten | 2017 |
APPLICATION OF THE EUROPEAN PROTOCOL IN THE EVALUATION OF DIGITAL MAMMOGRAPHY UNITS WITH TUNGSTEN TARGET TUBES.
Topics: Breast; Breast Neoplasms; Calibration; Europe; Female; Humans; Image Processing, Computer-Assisted; Linear Models; Mammography; Phantoms, Imaging; Radiation Dosage; Radiographic Image Enhancement; Rhodium; Signal-To-Noise Ratio; Silver; Software; Tungsten | 2019 |
Au
Topics: 1-Butanol; Alloys; Gold; Metal Nanoparticles; Oxides; Rhodium; Tungsten | 2019 |
Investigation of detector uniformity issues for Siemens Inspiration systems.
Topics: Algorithms; Artifacts; Breast Neoplasms; Calibration; Dose-Response Relationship, Drug; Female; Humans; Image Processing, Computer-Assisted; Mammography; Molybdenum; Phantoms, Imaging; Quality Control; Radiographic Image Enhancement; Reproducibility of Results; Rhodium; Selenium; Signal-To-Noise Ratio; Temperature; Tungsten; X-Rays | 2020 |
Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra.
Topics: Algorithms; Cadmium Compounds; Computer Simulation; False Positive Reactions; Female; Humans; Image Processing, Computer-Assisted; Mammography; Models, Statistical; Models, Theoretical; Molybdenum; Monte Carlo Method; Normal Distribution; Reproducibility of Results; Rhodium; Sensitivity and Specificity; Spectrophotometry; Tellurium; Tungsten; Uncertainty; X-Rays | 2020 |
Catalog of x-ray spectra of Mo-, Rh-, and W-anode-based x-ray tubes from 10 to 50 kV.
Topics: Electrodes; Mammography; Rhodium; Tungsten; X-Rays | 2021 |
Measured low-energy x-ray spectra of interest in diagnostic radiology and mammography.
Topics: Germanium; Humans; Mammography; Molybdenum; Monte Carlo Method; Radiology; Rhodium; Silver; Tungsten; Water; X-Rays | 2022 |