oxytetracycline--anhydrous has been researched along with acetonitrile* in 2 studies
2 other study(ies) available for oxytetracycline--anhydrous and acetonitrile
Article | Year |
---|---|
Determination of tetracyclines residues in honey by on-line solid-phase extraction high-performance liquid chromatography.
An automated system using on-line solid-phase extraction (SPE) high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of tetracyclines (TCs), such as tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC), metacycline (MC), and doxycycline (DC) in honey. One milliliter diluted honey sample was injected into a conditioned C18 SPE column and the matrix was washed out with water for 3 min. By rotation of the switching valve, TCs were eluted and transferred to the analytical column by the chromatographic mobile phase. Chromatographic conditions were optimized. TCs were separated in less than 8 min with a gradient elution using a mixture of 0.8% formic acid and acetonitrile. The UV detection was performed at 365 nm. The conditions for on-line SPE, including solvent and total time for loading sample and washing matrix were also optimized. Time for extraction and separation decreased greatly. For the five kinds of TCs, the limits of detection (LODs) at a signal-to-noise of 3 ranged from 5 to 12 ng g(-1). The relative standard deviations (R.S.D.) for the determination of TCs ranged from 3.4 to 7.1% within a day and ranged from 3.2 to 8.9% in 3 days, respectively. Topics: Acetonitriles; Anti-Bacterial Agents; Automation; Chlortetracycline; Chromatography, High Pressure Liquid; Doxycycline; Food Analysis; Formates; Honey; Methacycline; Oxytetracycline; Reproducibility of Results; Sensitivity and Specificity; Solid Phase Extraction; Solvents; Tetracyclines; Time Factors | 2008 |
C(18) columns for the simultaneous determination of oxytetracycline and its related substances by reversed-phase high performance liquid chromatography and UV detection.
Simultaneous determination of oxytetracycline, 4-epioxytetracycline, alpha-apooxytetracycline, tetracycline and beta-apooxytetracycline on C(18) columns has been accomplished using a high performance liquid chromatographic method with UV detection. Separation was achieved on a Hypersil BDS RP-C(18) column (250 mm x 4.6 mm) and on a Waters C(18) Symmetry column (150 mm x 3.9mm), 5 microm particle size each. These columns were equilibrated with mobile phases consisted of methanol-acetonitrile-0.1M phosphate buffer pH 8.0 (12.5:12.5:75, v/v/v) and (15:15:70, v/v/v), respectively. The flow rate was 1.0 ml/min and the total elution time was 15 and 5 min, respectively. Both methods were applied to oxytetracycline raw material, human and veterinary formulations, where the excipients did not interfere. External standard calibration curves were linear for 4-epioxytetracycline, oxytetracycline, alpha-apooxytetracycline, tetracycline and beta-apooxytetracycline in the concentration range of 0.27-200 microM, 0.05-200 microM, 0.03-200 microM, 0.35-200 microM and 0.20-200 microM on column A and 0.08-200 microM, 0.15-200 microM, 0.09-200 microM, 0.25-200 microM and 0.47-200 microM on column B, respectively. Day-to-day relative standard deviation of the determination for every component was less than 3%. Concerning the first column, limits of detection and quantification of the above compounds were in the concentration ranges of 10-106 nM and 30-352 nM, respectively, whereas on the second column these ranges became 27-144 nM and 81-475 nM, respectively. Recovery of the separated compounds was 95-105%. Topics: Acetonitriles; Anti-Bacterial Agents; Calibration; Chromatography, High Pressure Liquid; Methanol; Molecular Structure; Oxytetracycline; Reproducibility of Results; Silicon Dioxide; Solvents; Spectrophotometry, Ultraviolet; Technology, Pharmaceutical; Tetracycline; Time Factors; Veterinary Drugs | 2007 |