Page last updated: 2024-08-17

methylene blue and methylene green

methylene blue has been researched along with methylene green in 27 studies

Research

Studies (27)

TimeframeStudies, this research(%)All Research%
pre-19902 (7.41)18.7374
1990's3 (11.11)18.2507
2000's7 (25.93)29.6817
2010's15 (55.56)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Dutt, MK1
Deng, J; Lei, C1
Bolton, FJ; Marland, J; Phoenix, DA; Wainwright, M; Wareing, DR1
Akeo, K; Hiramitsu, T; Okisaka, S; Tsukamoto, H; Watanabe, K1
de Lucca, AR; Kubota, LT; Pereira, AC; Santos, Ade S1
BORISOV, IN1
Jura-Półtorak, A; Koźma, EM; Nawrat, Z; Olczyk, K; Olczyk, P; Wisowski, G1
Blackwell, AE; Minteer, SD; Ulyanova, YV1
Chang, TC; Lin, C1
Lin, Y; Mao, L; Su, L; Yu, P; Zhu, N1
Chen, SM; Ting, TW; Upadhyay, AK1
Blackwell, AE; Minteer, SD; Moehlenbrock, MJ; Worsham, JR1
Bagherian, G; Chamjangali, MA; Goudarzi, N; Namazi, N1
Adkins, E; Atanassov, P; Garcia, KE; Johnson, GR; Lau, C; Luckarift, HR; Rincón, RA1
Halámek, J; Katz, E; Valdés-Ramírez, G; Wang, J; Windmiller, JR; Zhou, M; Zhou, N1
Chesta, CA; Glusko, CA; Montejano, HA; Previtali, CM1
Azmat, R; Naz, R; Qamar, N1
Etienne, M; Kohring, GW; Urbanova, V; Walcarius, A; Wang, Z1
Cheng, H; Huang, P; Lu, X; Mao, L; Yang, L; Yu, P1
Jiang, Q; Ma, W; Mao, L; Yang, L; Yu, P1
Bolivar, JM; Brugger, D; Haltrich, D; Krondorfer, I; Nidetzky, B; Peterbauer, CK; Stoisser, T; Zahma, K1
Ghaedi, M; Karimi, H; Yousefi, F1
He, Y; Liu, S; Shen, Y; Wang, L; Yin, P1
Bülow, L; Kettisen, K; Sakai, H1
Contin, A; Conzuelo, F; Pinyou, P; Plumeré, N; Pöller, S; Schuhmann, W; Sliozberg, K; Vivekananthan, J1
Chung, TD; Han, SH; Jang, W; Lee, D; Lee, S; Rho, J1
John, CW; Proshlyakov, DA1

Other Studies

27 other study(ies) available for methylene blue and methylene green

ArticleYear
Method for the demonstration of DNA-phosphate groups and DNA-aldehyde molecules with a basic dye, methylene green.
    Cellular and molecular biology, including cyto-enzymology, 1980, Volume: 26, Issue:2

    Topics: Aldehydes; Animals; Coloring Agents; DNA; Histocytochemistry; Kidney; Liver; Methylene Blue; Phosphates; Rats; Staining and Labeling

1980
Hydrogen peroxide sensor based on coimmobilized methylene green and horseradish peroxidase in the same montmorillonite-modified bovine serum albumin-glutaraldehyde matrix on a glassy carbon electrode surface.
    Analytical chemistry, 1996, Oct-01, Volume: 68, Issue:19

    Topics: Bentonite; Biosensing Techniques; Carbon; Colloids; Coloring Agents; Electrodes; Glutaral; Horseradish Peroxidase; Hydrogen Peroxide; Methylene Blue; Serum Albumin, Bovine; Spectrophotometry, Ultraviolet

1996
A study of photobactericidal activity in the phenothiazinium series.
    FEMS immunology and medical microbiology, 1997, Volume: 19, Issue:1

    Topics: Acridine Orange; Bacillus cereus; Coloring Agents; Dermatitis, Phototoxic; Enterococcus faecalis; Escherichia coli; Gram-Negative Bacteria; Gram-Positive Bacteria; Light; Methylene Blue; Molecular Structure; Oxygen; Photosensitizing Agents; Proflavine; Pseudomonas aeruginosa; Staphylococcus aureus; Tolonium Chloride

1997
The localization of glutathione peroxidase in the photoreceptor cells and the retinal pigment epithelial cells of Wistar and Royal College of Surgeons dystrophic rats.
    Pigment cell research, 1999, Volume: 12, Issue:2

    Topics: Animals; Coloring Agents; Female; Glutathione Peroxidase; Horseradish Peroxidase; Immunoblotting; Methylene Blue; Osmium Tetroxide; p-Dimethylaminoazobenzene; Pigment Epithelium of Eye; Rats; Rats, Wistar; Retinal Degeneration; Retinal Rod Photoreceptor Cells

1999
Electrochemical behavior and electrocatalytic study of the methylene green coated on modified silica gel.
    Journal of colloid and interface science, 2002, Oct-01, Volume: 254, Issue:1

    Topics: Catalysis; Electrochemistry; Electrodes; Hydrogen-Ion Concentration; Methylene Blue; NAD; Oxidation-Reduction; Silica Gel; Silicon Dioxide

2002
[On the technic of staining with methylene green-pyronin].
    Arkhiv patologii, 1963, Volume: 35(3)

    Topics: Coloring Agents; Methylene Blue; Staining and Labeling

1963
The influence of physical and chemical agents on photooxidation of porcine pericardial collagen.
    Bio-medical materials and engineering, 2005, Volume: 15, Issue:3

    Topics: Animals; Biocompatible Materials; Collagen; Coloring Agents; Light; Methylene Blue; Oxidants, Photochemical; Oxygen; Pepsin A; Pericardium; Swine; Time Factors

2005
Poly(methylene green) employed as molecularly imprinted polymer matrix for electrochemical sensing.
    The Analyst, 2006, Volume: 131, Issue:2

    Topics: Bronchodilator Agents; Coloring Agents; Electrochemistry; Humans; Methylene Blue; Microscopy, Electron, Transmission; Polymers; Theophylline

2006
Photosensitized reduction of DDT using visible light: the intermediates and pathways of dechlorination.
    Chemosphere, 2007, Volume: 66, Issue:6

    Topics: DDT; Dichlorodiphenyl Dichloroethylene; Environmental Restoration and Remediation; Kinetics; Light; Methylene Blue; Oxidation-Reduction; Photosensitizing Agents

2007
Physiologically relevant online electrochemical method for continuous and simultaneous monitoring of striatum glucose and lactate following global cerebral ischemia/reperfusion.
    Analytical chemistry, 2009, Mar-15, Volume: 81, Issue:6

    Topics: Animals; Biosensing Techniques; Brain Ischemia; Carbon; Corpus Striatum; Electrochemical Techniques; Electrodes; Glucose; Glucose Dehydrogenases; Hydrogen-Ion Concentration; Lactate Dehydrogenases; Lactic Acid; Male; Methylene Blue; NAD; Nanotubes, Carbon; Oxidation-Reduction; Rats; Rats, Sprague-Dawley; Reperfusion Injury

2009
Amperometric biosensor for hydrogen peroxide based on coimmobilized horseradish peroxidase and methylene green in ormosils matrix with multiwalled carbon nanotubes.
    Talanta, 2009, Jun-30, Volume: 79, Issue:1

    Topics: Biosensing Techniques; Electrochemical Techniques; Electrodes; Enzymes, Immobilized; Horseradish Peroxidase; Hydrogen Peroxide; Hydrogen-Ion Concentration; Methylene Blue; Nanotubes, Carbon; Sensitivity and Specificity; Siloxanes; Temperature

2009
Comparison of electropolymerized thiazine dyes as an electrocatalyst in enzymatic biofuel cells and self powered sensors.
    Journal of nanoscience and nanotechnology, 2009, Volume: 9, Issue:3

    Topics: Bioelectric Energy Sources; Bioreactors; Biosensing Techniques; Carbon; Electrochemical Techniques; Equipment Failure; Glucose 1-Dehydrogenase; Kinetics; Methylene Blue; NAD; Oxidation-Reduction; Phenothiazines; Polymers

2009
Selective spectrophotometric determination of periodate based on its reaction with methylene green and its application to indirect determination of ethylene glycol and glycerol.
    Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 2010, Volume: 76, Issue:1

    Topics: Ethylene Glycol; Glycerol; Hydrogen-Ion Concentration; Limit of Detection; Methylene Blue; Olive Oil; Periodic Acid; Plant Oils; Spectrophotometry; Water

2010
Enzymatic fuel cells: integrating flow-through anode and air-breathing cathode into a membrane-less biofuel cell design.
    Biosensors & bioelectronics, 2011, Sep-15, Volume: 27, Issue:1

    Topics: Alcohol Dehydrogenase; Bioelectric Energy Sources; Electrodes; Electron Transport; Fungi; Laccase; Malate Dehydrogenase; Methylene Blue

2011
Enzyme-based NAND gate for rapid electrochemical screening of traumatic brain injury in serum.
    Analytica chimica acta, 2011, Oct-03, Volume: 703, Issue:1

    Topics: Biocatalysis; Biomarkers; Brain Injuries; Buffers; Electrochemistry; Electrodes; Glutamic Acid; Humans; Hydrogen-Ion Concentration; L-Lactate Dehydrogenase; Methylene Blue; NAD; Time Factors

2011
Simple procedures for analyzing and purifying methylene green.
    Biotechnic & histochemistry : official publication of the Biological Stain Commission, 2012, Volume: 87, Issue:5

    Topics: Chemistry Techniques, Analytical; Chromatography, Thin Layer; Methylene Blue; Molecular Structure; Time Factors

2012
Reduction of methylene green by EDTA: a relation between dielectric constant of medium and activated state.
    Pakistan journal of pharmaceutical sciences, 2013, Volume: 26, Issue:1

    Topics: Chromatography, High Pressure Liquid; Coloring Agents; Edetic Acid; Hydrogen-Ion Concentration; Kinetics; Linear Models; Mass Spectrometry; Methanol; Methylene Blue; Models, Chemical; Osmolar Concentration; Oxidation-Reduction; Reducing Agents; Solvents; Spectrum Analysis; Temperature; Ultraviolet Rays; Water

2013
Reagentless D-sorbitol biosensor based on D-sorbitol dehydrogenase immobilized in a sol-gel carbon nanotubes-poly(methylene green) composite.
    Analytical and bioanalytical chemistry, 2013, Volume: 405, Issue:11

    Topics: Biosensing Techniques; Enzymes, Immobilized; L-Iditol 2-Dehydrogenase; Limit of Detection; Methylene Blue; NAD; Nanotubes, Carbon; Phase Transition; Polymers; Sorbitol

2013
Hybridization of bioelectrochemically functional infinite coordination polymer nanoparticles with carbon nanotubes for highly sensitive and selective in vivo electrochemical monitoring.
    Analytical chemistry, 2013, Apr-16, Volume: 85, Issue:8

    Topics: Animals; Biosensing Techniques; Corpus Striatum; Electrochemical Techniques; Glucose; Glucose 1-Dehydrogenase; Guinea Pigs; Male; Methylene Blue; Microdialysis; Microelectrodes; NAD; Nanoparticles; Nanotubes, Carbon; Polymerization; Sensitivity and Specificity; Terbium

2013
Zeolitic imidazolate framework-based electrochemical biosensor for in vivo electrochemical measurements.
    Analytical chemistry, 2013, Aug-06, Volume: 85, Issue:15

    Topics: Adsorption; Animals; Biosensing Techniques; Electrochemistry; Glucose 1-Dehydrogenase; Guinea Pigs; Imidazoles; Male; Methylene Blue; Models, Molecular; Molecular Conformation; Organometallic Compounds; Pseudomonas; Zeolites

2013
Convenient microtiter plate-based, oxygen-independent activity assays for flavin-dependent oxidoreductases based on different redox dyes.
    Biotechnology journal, 2014, Volume: 9, Issue:4

    Topics: 2,6-Dichloroindophenol; Coloring Agents; Enzyme Assays; High-Throughput Screening Assays; Methylene Blue; Oxidation-Reduction; Oxidoreductases; Phenothiazines

2014
Silver and zinc oxide nanostructures loaded on activated carbon as new adsorbents for removal of methylene green: a comparative study.
    Human & experimental toxicology, 2014, Volume: 33, Issue:9

    Topics: Adsorption; Carbon; Hydrogen-Ion Concentration; Methylene Blue; Molecular Structure; Nanostructures; Osmolar Concentration; Oxides; Silver Compounds; Temperature; Water Pollutants, Chemical; Water Purification; Zinc Oxide

2014
Characterization of the interaction of a mono-6-thio-β-cyclodextrin-capped CdTe quantum dots-methylene blue/methylene green system with herring sperm DNA using a spectroscopic approach.
    Luminescence : the journal of biological and chemical luminescence, 2014, Volume: 29, Issue:7

    Topics: Animals; beta-Cyclodextrins; Cadmium Compounds; DNA; Fishes; Male; Methylene Blue; Molecular Structure; Quantum Dots; Spectrometry, Fluorescence; Spermatozoa; Tellurium

2014
Potential electron mediators to extract electron energies of RBC glycolysis for prolonged in vivo functional lifetime of hemoglobin vesicles.
    Bioconjugate chemistry, 2015, Apr-15, Volume: 26, Issue:4

    Topics: Azure Stains; Benzoxazines; Blood Substitutes; Drug Compounding; Electrons; Erythrocytes; Glycolysis; Hemoglobins; Humans; Indigo Carmine; Indoles; Liposomes; Methemoglobin; Methylene Blue; NADP; Oxazines; Oxidation-Reduction; Oxygen

2015
Coupling of an enzymatic biofuel cell to an electrochemical cell for self-powered glucose sensing with optical readout.
    Bioelectrochemistry (Amsterdam, Netherlands), 2015, Volume: 106, Issue:Pt A

    Topics: Biocatalysis; Bioelectric Energy Sources; Biosensing Techniques; Electrodes; Enzymes, Immobilized; Glucose; Glucose 1-Dehydrogenase; Hypocreales; Methylene Blue; Models, Molecular; Optical Phenomena; Oxidation-Reduction; Oxidoreductases Acting on CH-CH Group Donors; Protein Conformation

2015
3D interdigitated electrode array in the microchannel free of reference and counter electrodes.
    Biosensors & bioelectronics, 2018, Mar-15, Volume: 101

    Topics: Biosensing Techniques; Creatine Kinase, MB Form; Electrochemical Techniques; Electrodes; Equipment Design; Humans; Immunoassay; Indoles; Limit of Detection; Methylene Blue; Oxidation-Reduction; Polymers

2018
Fourier Transform Infrared Spectrovoltammetry and Quantitative Modeling of Analytes in Kinetically Constrained Redox Mixtures.
    Analytical chemistry, 2019, 08-06, Volume: 91, Issue:15

    Topics: Electrochemical Techniques; Methylene Blue; Models, Chemical; Myoglobin; Oxidation-Reduction; Phenothiazines; Spectroscopy, Fourier Transform Infrared

2019