likviriton and magnolol

likviriton has been researched along with magnolol* in 3 studies

Other Studies

3 other study(ies) available for likviriton and magnolol

ArticleYear
[Simultaneous determination of six ingredients in Huoxiang Zhengqi oral liquid by UPLC].
    Zhongguo Zhong yao za zhi = Zhongguo zhongyao zazhi = China journal of Chinese materia medica, 2013, Volume: 38, Issue:14

    To develop a UPLC method for the simultaneous determination of liquiritin, narirutin, hesperidin, ammonium glycyrrhetate, honokiol and magnolol in Huoxiang Zhengqi oral liquid.. A Zorbax Eclipse C18 column was used with the mobile phase of acetonitrile and 0. 05% phosphate acid by gradient elution at the detection wavelength of 220 nm. The flow rate was 0.42 mL x min(-1) and the column temperature was 30 degrees C.. The calibration curves were linear in the ranges of 0.001 7-0.034, 0.003 4-0.068, 0.006 4-0.128, 0.012 8-0.256, 0.003 2-0.064, 0.006 4-0.128 microg, respectively. The average recoveries were 103.3%, 98.39%, 98.29%, 102.1%, 98.45%, 102.2% with RSDs of 2.1%,1.0%, 0.50%, 2.3%, 0.9%, 2.0%, respectively.. The UPLC method was simple, rapid and accurate, it could be used for quality control of Huoxiang Zhengqi oral liquid.

    Topics: Administration, Oral; Biphenyl Compounds; Chromatography, High Pressure Liquid; Disaccharides; Drugs, Chinese Herbal; Flavanones; Glucosides; Hesperidin; Lignans; Pharmaceutical Solutions

2013
Simultaneous determination of 12 chemical constituents in the traditional Chinese Medicinal Prescription Xiao-Yao-San-Jia-Wei by HPLC coupled with photodiode array detection.
    Journal of pharmaceutical and biomedical analysis, 2008, Dec-15, Volume: 48, Issue:5

    An HPLC-photodiode array (PDA) detection method was established for the simultaneous determination of 12 components in Xiao-Yao-San-Jia-Wei (XYSJW): geniposide, puerarin, paeoniflorin, ferulic acid, liquiritin, hesperidin, naringin, paeonol, daidzein, glycyrrhizic acid, honokiol, and magnolol. These were separated in less than 70 min using a Waters Symmetry Shield RP 18 column with gradient elution using (A) acetonitrile, (B) water, and (C) acetic acid at a flow rate of 1 ml/min, and with a PDA detector. All calibration curves showed good linear regression (r(2)>0.9992) within the test ranges. The method was validated for specificity, accuracy, precision, and limits of detection. The proposed method enables in a single run the simultaneous identification and determination for quality control of 12 multi-structural components of XYSJW forming the basis of its therapeutic effect.

    Topics: Acetophenones; Benzoates; Biphenyl Compounds; Bridged-Ring Compounds; Coumaric Acids; Drugs, Chinese Herbal; Flavanones; Glucosides; Glycyrrhizic Acid; Hesperidin; Iridoids; Isoflavones; Lignans; Medicine, Chinese Traditional; Molecular Structure; Monoterpenes; Quality Control; Reference Standards; Reproducibility of Results; Sensitivity and Specificity

2008
Determination of liquiritin, naringin, hesperidin, thymol, imperatorin, honokiol, isoimperatorin, and magnolol in the traditional Chinese medicinal preparation Huoxiang-zhengqi liquid using high-performance liquid chromatography.
    Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan, 2006, Volume: 126, Issue:11

    High-performance liquid chromatography was employed to determine the contents of the eight marker components liquiritin, naringin, hesperidin, thymol, imperatorin, honokiol, isoimperatorin, and magnolol in the traditional Chinese medicinal preparation Huoxiang-zhengqi liquid. The separation was performed on a C(18) column by stepwise gradient elution with water-methanol-acetonitrile (0.01 min, 68:30:2; 20 min, 60:38:2; 50 min, 34:64:2; 65 min, 34:64:2; 75 min, 28:70:2; 85 min, 68:30:2) as the mobile phase at a flow rate of 1 ml/min, with UV detection at 283 nm. Eight regression equations showed good linear relationships between the peak area ratio of each marker to internal standard and amounts. The recoveries of the markers listed above were 97.4, 98.5, 97.4, 98.6, 97.8, 99.2, 97.0, and 97.5%, respectively. The repeatability and reproducibility (relative standard deviation) of the method were less than 2.2 and 3.0%, respectively.

    Topics: Biphenyl Compounds; Chromatography, High Pressure Liquid; Drugs, Chinese Herbal; Flavanones; Furocoumarins; Glucosides; Hesperidin; Lignans; Reproducibility of Results; Solutions; Thymol

2006