likviriton has been researched along with daidzein* in 3 studies
3 other study(ies) available for likviriton and daidzein
Article | Year |
---|---|
Simultaneous determination of puerarin, daidzin, daidzein, paeoniflorin, albiflorin, liquiritin and liquiritigenin in rat plasma and its application to a pharmacokinetic study of Ge-Gen Decoction by a liquid chromatography-electrospray ionization-tandem m
A liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for simultaneous determination of seven constituents including puerarin, daidzin, daidzein, paeoniflorin, albiflorin, liquiritin and liquiritigenin in rat plasma using schisandrin as the internal standard (IS). The plasma samples were pretreated by a one-step direct protein precipitation with acetonitrile. The chromatographic separation was carried out on a C18 column with a gradient mobile phase consisting of acetonitrile and water (containing 0.1% formic acid and 5mM ammonium acetate). All analytes and IS were quantitated through electrospray ionization in positive ion multiple reaction monitoring (MRM) mode. The mass transitions were as follows: m/z 417.5→297.2 for puerarin, m/z 417.1→255.2 for daidzin, m/z 255.2→152.4 for daidzein, m/z 498.1→179.3 for paeoniflorin, m/z 481.1→197.3 for albiflorin, m/z 436.2→257.3 for liquiritin, m/z 257.2→137.3 for liquiritigenin and m/z 415.0→384.2 for IS, respectively. All calibration curves exhibited good linearity (r>0.9979) over a wide concentration range for all components. The intra-day and inter-day precisions (RSD) at three different levels were both less than 14.3% and the accuracies (RE) ranged from -13.2% to 14.8%. The extraction recoveries of the seven compounds ranged from 72.9% to 117.4%. The validated method was successfully applied to pharmacokinetic study of the seven components in female rat plasma after oral administration of Ge-Gen Decoction aqueous extract. Topics: Animals; Bridged-Ring Compounds; Chromatography, High Pressure Liquid; Drugs, Chinese Herbal; Flavanones; Glucosides; Isoflavones; Monoterpenes; Rats; Spectrometry, Mass, Electrospray Ionization; Tandem Mass Spectrometry | 2014 |
Simultaneous determination of puerarin, daidzein, baicalin, wogonoside and liquiritin of GegenQinlian decoction in rat plasma by ultra-performance liquid chromatography-mass spectrometry.
A specific ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) method was developed for the simultaneous determination of puerarin, daidzein, baicalin, wogonoside and liquiritin in rat plasma. Chromatographic separation was performed on a C(18) column packed with 1.7 microm particles by a linear gradient elution. The analytes and carbamazepine (internal standard, I.S.) were monitored in a selected-ion reaction (SIR) mode with a positive electrospray ionization (ESI) interface by the following ions: m/z 417.2 for puerarin, m/z 255.2 for daidzein, m/z 271.0 for baicalin, m/z 461.0 for wogonoside, m/z 441.0 for liquiritin and m/z 237.2 for carbamazepine (I.S.), respectively. The calibration curves of these analytes were linear over the concentration ranges from 0.00254-1.02 microg mL(-1) to 0.0102-10.2 microg mL(-1). Within-batch and between-batch precisions (RSD%) were all within 15% and accuracy (RE%) ranged from -10% to 10%. The extraction recoveries were on average 79.8% for puerarin, 90.8% for daidzein, 74.4% for baicalin, 70.2% for wogonoside and 84.7% for liquiritin. The validated method was successfully applied to investigate the pharmacokinetics of five bioactive compounds of GegenQinlian decoction (GQD) in rats. Topics: Animals; Chromatography, High Pressure Liquid; Drugs, Chinese Herbal; Flavanones; Flavonoids; Glucosides; Isoflavones; Mass Spectrometry; Rats; Sensitivity and Specificity | 2009 |
Simultaneous determination of 12 chemical constituents in the traditional Chinese Medicinal Prescription Xiao-Yao-San-Jia-Wei by HPLC coupled with photodiode array detection.
An HPLC-photodiode array (PDA) detection method was established for the simultaneous determination of 12 components in Xiao-Yao-San-Jia-Wei (XYSJW): geniposide, puerarin, paeoniflorin, ferulic acid, liquiritin, hesperidin, naringin, paeonol, daidzein, glycyrrhizic acid, honokiol, and magnolol. These were separated in less than 70 min using a Waters Symmetry Shield RP 18 column with gradient elution using (A) acetonitrile, (B) water, and (C) acetic acid at a flow rate of 1 ml/min, and with a PDA detector. All calibration curves showed good linear regression (r(2)>0.9992) within the test ranges. The method was validated for specificity, accuracy, precision, and limits of detection. The proposed method enables in a single run the simultaneous identification and determination for quality control of 12 multi-structural components of XYSJW forming the basis of its therapeutic effect. Topics: Acetophenones; Benzoates; Biphenyl Compounds; Bridged-Ring Compounds; Coumaric Acids; Drugs, Chinese Herbal; Flavanones; Glucosides; Glycyrrhizic Acid; Hesperidin; Iridoids; Isoflavones; Lignans; Medicine, Chinese Traditional; Molecular Structure; Monoterpenes; Quality Control; Reference Standards; Reproducibility of Results; Sensitivity and Specificity | 2008 |