iohexol and technetium tc 99m pentetate

iohexol has been researched along with technetium tc 99m pentetate in 23 studies

Research

Studies (23)

TimeframeStudies, this research(%)All Research%
pre-19902 (8.70)18.7374
1990's15 (65.22)18.2507
2000's3 (13.04)29.6817
2010's3 (13.04)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Brown, SC; O'Reilly, PH1
Monclair, T; Monn, E; Rootwelt, K; Stake, G2
Almén, T; Bergquist, D; Frennby, B; Hellsten, S; Lilja, B; Nyman, U; Sterner, G; Törnquist, C1
Effersöe, H; Golman, K; Groth, S; Jensen, LI; Rosenkilde, P1
Grönberg, T; Monclair, T; Monn, E; Rootwelt, K; Stake, G1
Farah, NB; Jones, DA; O'Reilly, PH1
Ekholm, SE; Fonte, D; Holtas, S; Isaac, L; Morris, TW1
Almén, T; Eriksson, LG; Frennby, B; Hellsten, S; Lilja, B; Lindblad, B; Nilsson, M; Nyman, U; Törnquist, C1
Heiene, R; Moe, L1
Gleadhill, A; Michell, AR1
Berg, KJ; Jakobsen, JA; Kjaersgaard, P; Kolmannskog, F; Nordal, KP; Nossen, JO; Rootwelt, K1
Bomanji, JB; Dhawan, RT; Ell, PJ; Foo, M; Setna, FJ1
Frennby, B1
Auner, I; Bianchi, C; Donadio, C; Lucchesi, A; Tramonti, G1
Aas, M; Cappelen, T; Skretting, A; Winderen, M1
Houlihan, C; Jenkins, M; Jerums, G; Osicka, T; Parkin, D; Scott, A1
Fünfstück, R; Gottschild, D; Hartung, R; Keil, E; Stein, G; Wiendieck, E1
Bailey, DB; Dykes, NL; Prey, JD; Rassnick, KM1
Guliaev, AM; Lishmanov, IuB; Rybal'chenko, EV; Vesnina, ZhV1
Egilmez, H; Erselcan, T; Hasbek, Z; Tandogan, I1
Chen, CY; Gong, MC; Jing, HL; Li, F; Li, XM; Qin, Y; Shi, XM; Song, HM; Wang, BB; Wu, Y1
Feng, CX; McCrea, CA; Milo, JE; Montgomery, JE; Snead, EC; Wanasundara, SN; Wesolowski, CA; Wesolowski, MJ1

Trials

3 trial(s) available for iohexol and technetium tc 99m pentetate

ArticleYear
Angiography with nonionic X-ray contrast media in severe chronic renal failure: renal function and contrast retention.
    Nephron, 1996, Volume: 73, Issue:4

    Topics: Adult; Aged; Angiography; Contrast Media; Double-Blind Method; Female; Glomerular Filtration Rate; Humans; Iohexol; Kidney Failure, Chronic; Kidney Function Tests; Male; Middle Aged; Prospective Studies; Technetium Tc 99m Pentetate; Tomography, X-Ray Computed; Triiodobenzoic Acids

1996
A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes.
    Australian and New Zealand journal of medicine, 1999, Volume: 29, Issue:5

    Topics: Adult; Aged; Contrast Media; Diabetes Mellitus; Electrophoresis, Capillary; Female; Glomerular Filtration Rate; Humans; Iohexol; Male; Metabolic Clearance Rate; Middle Aged; Technetium Tc 99m Pentetate

1999
[Radionuclide renoscintigraphy for the evaluation of nephroprotective action of acetylcysteine].
    Klinicheskaia meditsina, 2009, Volume: 87, Issue:10

    Topics: Acetylcysteine; Contrast Media; Coronary Angiography; Female; Follow-Up Studies; Free Radical Scavengers; Humans; Injections, Intravenous; Iohexol; Male; Middle Aged; Myocardial Ischemia; Radionuclide Imaging; Radiopharmaceuticals; Renal Insufficiency; Technetium Tc 99m Pentetate; Treatment Outcome

2009

Other Studies

20 other study(ies) available for iohexol and technetium tc 99m pentetate

ArticleYear
The estimate of glomerular filtration rate during urography. Acceptability of a nonionic contrast medium as a marker of renal function.
    Investigative radiology, 1992, Volume: 27, Issue:10

    Topics: Aged; Creatinine; Glomerular Filtration Rate; Humans; Iohexol; Male; Middle Aged; Technetium Tc 99m Pentetate; Urography

1992
The clearance of iohexol as a measure of the glomerular filtration rate in children with chronic renal failure.
    Scandinavian journal of clinical and laboratory investigation, 1991, Volume: 51, Issue:8

    Topics: Adolescent; Child; Child, Preschool; Female; Glomerular Filtration Rate; Humans; Iohexol; Kidney Failure, Chronic; Male; Metabolic Clearance Rate; Reference Values; Technetium Tc 99m Pentetate

1991
Use of urographic contrast media to determine glomerular filtration rate. Determining the glomerular filtration rate of each kidney with computed tomography and scintigraphy.
    Investigative radiology, 1991, Volume: 26 Suppl 1

    Topics: Adult; Aged; Female; Gamma Cameras; Glomerular Filtration Rate; Humans; Iohexol; Kidney; Kidney Diseases; Male; Middle Aged; Radionuclide Imaging; Technetium Tc 99m Pentetate; Tomography, X-Ray Computed

1991
A single plasma sample method for estimation of the glomerular filtration rate in infants and children using iohexol, II: Establishment of the optimal plasma sampling time and a comparison with the 99Tcm-DTPA method.
    Scandinavian journal of clinical and laboratory investigation, 1991, Volume: 51, Issue:4

    Topics: Adolescent; Child; Child, Preschool; Evaluation Studies as Topic; Female; Glomerular Filtration Rate; Humans; Infant; Infant, Newborn; Injections, Intravenous; Iohexol; Male; Metabolic Clearance Rate; Technetium Tc 99m Pentetate; Time Factors

1991
Measurement of renal function with iohexol. A comparison of iohexol, 99mTc-DTPA, and 51Cr-EDTA clearance.
    Investigative radiology, 1990, Volume: 25, Issue:7

    Topics: Adult; Aged; Chromium; Edetic Acid; Female; Glomerular Filtration Rate; Humans; Iohexol; Male; Organotechnetium Compounds; Pentetic Acid; Radioisotope Renography; Technetium Tc 99m Pentetate

1990
Glomerular filtration rate estimated by X-ray fluorescence technique in children: comparison between the plasma disappearance of 99Tcm-DTPA and iohexol after urography.
    Scandinavian journal of clinical and laboratory investigation, 1990, Volume: 50, Issue:2

    Topics: Adolescent; Child; Child, Preschool; Female; Fluorescence; Glomerular Filtration Rate; Humans; Iohexol; Male; Organotechnetium Compounds; Pentetic Acid; Radionuclide Imaging; Technetium Tc 99m Pentetate; Urography; Urologic Diseases

1990
Measurement of the plasma clearance of urographic contrast media for the determination of glomerular filtration rate.
    The Journal of urology, 1988, Volume: 139, Issue:1

    Topics: Adult; Aged; Evaluation Studies as Topic; Glomerular Filtration Rate; Humans; Iohexol; Microcomputers; Middle Aged; Organometallic Compounds; Pentetic Acid; Spectrometry, X-Ray Emission; Technetium; Technetium Tc 99m Pentetate; Urography

1988
Penetration of subarachnoid contrast medium into rabbit spinal cord. Comparison between metrizamide and iohexol.
    Investigative radiology, 1986, Volume: 21, Issue:2

    Topics: Animals; Contrast Media; Iodobenzoates; Iohexol; Metrizamide; Pentetic Acid; Perfusion; Rabbits; Spinal Cord; Subarachnoid Space; Technetium; Technetium Tc 99m Pentetate; Triiodobenzoic Acids

1986
Determination of the relative glomerular filtration rate of each kidney in man. Comparison between iohexol CT and 99mTc-DTPA scintigraphy.
    Acta radiologica (Stockholm, Sweden : 1987), 1995, Volume: 36, Issue:4

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Evaluation Studies as Topic; Female; Glomerular Filtration Rate; Humans; Iohexol; Kidney; Male; Middle Aged; Radioisotope Renography; Technetium Tc 99m Pentetate; Time Factors; Tomography, X-Ray Computed

1995
Estimation of glomerular filtration rate in dogs with 99M-Tc-DTPA and iohexol.
    Research in veterinary science, 1995, Volume: 58, Issue:2

    Topics: Animals; Dog Diseases; Dogs; Female; Glomerular Filtration Rate; Iohexol; Kidney Diseases; Male; Technetium Tc 99m Pentetate

1995
Evaluation of iohexol as a marker for the clinical measurement of glomerular filtration rate in dogs.
    Research in veterinary science, 1996, Volume: 60, Issue:2

    Topics: Animals; Automation; Contrast Media; Dog Diseases; Dogs; Glomerular Filtration Rate; Humans; Iohexol; Kidney Diseases; Metabolic Clearance Rate; Regression Analysis; Reproducibility of Results; Software; Technetium Tc 99m Pentetate

1996
Contrast nephrotoxicity and the role of radionuclide renal scan.
    Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 1996, Volume: 37, Issue:11

    Topics: Aged; Contrast Media; Humans; Iohexol; Kidney; Kidney Tubular Necrosis, Acute; Male; Middle Aged; Radionuclide Imaging; Technetium Tc 99m Mertiatide; Technetium Tc 99m Pentetate

1996
Use of iohexol clearance to determine the glomerular filtration rate. A comparison between different clearance techniques in man and animal.
    Scandinavian journal of urology and nephrology. Supplementum, 1997, Volume: 182

    Topics: Adolescent; Adult; Aged; Aged, 80 and over; Animals; Chromium Radioisotopes; Contrast Media; Edetic Acid; Female; Glomerular Filtration Rate; Humans; Iohexol; Kidney; Male; Metabolic Clearance Rate; Middle Aged; Radionuclide Imaging; Swine; Technetium Tc 99m Pentetate; Tomography, X-Ray Computed

1997
Early glomerular effects of contrast media in rats: evaluation with a simple method.
    Renal failure, 1998, Volume: 20, Issue:5

    Topics: Animals; Contrast Media; Diatrizoate; Disease Models, Animal; Glomerular Filtration Rate; Injections, Intravenous; Iohexol; Iopamidol; Kidney Glomerulus; Male; Osmolar Concentration; Rats; Rats, Sprague-Dawley; Reference Values; Technetium Tc 99m Pentetate; Time Factors

1998
[Measurement of glomerular filtration rate in connection with 99Tc-DTPA renography].
    Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke, 1999, Feb-10, Volume: 119, Issue:4

    Topics: Chromium Radioisotopes; Contrast Media; Creatinine; Glomerular Filtration Rate; Humans; Iohexol; Kidney Neoplasms; Radioisotope Renography; Radiopharmaceuticals; Technetium Tc 99m Pentetate

1999
[Validity of iohexol clearance in patients with chronic renal failure and normal renal function in comparison to (99m)Tc-DTPA-clearance].
    Deutsche medizinische Wochenschrift (1946), 2003, Jan-17, Volume: 128, Issue:3

    Topics: Adult; Aged; Aged, 80 and over; Contrast Media; Female; Glomerular Filtration Rate; Humans; Iohexol; Metabolic Clearance Rate; Middle Aged; Radiopharmaceuticals; Reference Values; Renal Insufficiency; Spectrometry, X-Ray Emission; Technetium Tc 99m Pentetate

2003
Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats.
    American journal of veterinary research, 2009, Volume: 70, Issue:9

    Topics: Animals; Area Under Curve; Body Surface Area; Body Weight; Carboplatin; Carcinoma; Cat Diseases; Cats; Chromatography, High Pressure Liquid; Glomerular Filtration Rate; Iohexol; Metabolic Clearance Rate; Sarcoma; Technetium Tc 99m Pentetate

2009
Contrast-induced nephropathy: controlled study by differential GFR measurement in hospitalized patients.
    Acta radiologica (Stockholm, Sweden : 1987), 2012, Mar-01, Volume: 53, Issue:2

    Topics: Blood Urea Nitrogen; Contrast Media; Creatinine; Female; Glomerular Filtration Rate; Humans; Inpatients; Iohexol; Iopamidol; Kidney Diseases; Male; Middle Aged; Prospective Studies; Technetium Tc 99m Pentetate

2012
Application of plasma clearance of iohexol in evaluating renal function in chinese children with chronic kidney disease.
    Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae, 2015, Volume: 37, Issue:2

    Topics: Child; Glomerular Filtration Rate; Humans; Iohexol; Renal Insufficiency, Chronic; Technetium Tc 99m Pentetate

2015
Tikhonov gamma variate adaptive regularization applied to technetium Tc 99m diethylenetriamine pentaacetic acid plasma clearance, compared with three other methods, for measuring glomerular filtration rate in cats.
    American journal of veterinary research, 2019, Volume: 80, Issue:4

    Topics: Animals; Cats; Creatinine; Female; Gamma Cameras; Glomerular Filtration Rate; Iohexol; Kidney Function Tests; Radionuclide Imaging; Radiopharmaceuticals; Technetium Tc 99m Pentetate

2019