hydrocodone has been researched along with benzoylecgonine* in 2 studies
2 other study(ies) available for hydrocodone and benzoylecgonine
Article | Year |
---|---|
Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass spectrometry: comparison with nominal mass technology.
High-resolution mass spectrometry (HRMS) is being applied in postmortem drug screening as an alternative to nominal mass spectrometry, and additional evaluation in quantitative casework is needed. We report quantitative analysis of benzoylecgonine, citalopram, cocaethylene, cocaine, codeine, dextromethorphan, dihydrocodeine, diphenhydramine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, hydrocodone, hydromorphone, meperidine, methadone, morphine, oxycodone and oxymorphone in postmortem blood by ultra-performance liquid chromatography (UPLC)-MS(E)/time-of-flight (TOF). The method employs analyte-matched deuterated internal standardization and MS(E) acquisition of precursor and product ions at low (6 eV) and ramped (10-40 eV) collision energies, respectively. Quantification was performed using precursor ion data obtained with a mass extraction window of ± 5 ppm. Fragment and residual precursor ion acquisitions at ramped collision energies were evaluated as additional analyte identifiers. Extraction recovery of >60% and matrix effect of <20% were determined for all analytes and internal standards. Defined limits of detection (10 ng/mL) and quantification (25 ng/mL) were validated along with a linearity analytical range of 25-3,000 ng/mL (R(2) > 0.99) for all analytes. Parallel UPLC-MS(E)/TOF and UPLC-MS/MS analysis showed comparable precision and bias along with concordance of 253 positive (y = 1.002x + 1.523; R(2) = 0.993) and 2,269 negative analyte findings in 159 postmortem cases. Analytical performance and correlation studies demonstrate accurate quantification by UPLC-MS(E)/TOF and extended application of HRMS in postmortem casework. Topics: Blood Chemical Analysis; Chromatography, High Pressure Liquid; Chromatography, Liquid; Citalopram; Cocaine; Codeine; Dextromethorphan; Diphenhydramine; Evaluation Studies as Topic; Forensic Pathology; Humans; Hydrocodone; Hydromorphone; Meperidine; Methadone; Morphine; Oxycodone; Oxymorphone; Pyrrolidines; Quality Control; Reproducibility of Results; Tandem Mass Spectrometry | 2014 |
Dilute and shoot: analysis of drugs of abuse using selected reaction monitoring for quantification and full scan product ion spectra for identification.
Our objective was to develop a "dilute and shoot" liquid chromatography-tandem mass spectrometry confirmatory procedure that uses full scan product ion spectra to identify drugs that are present above cutoff values as determined by isotope dilution relative to a deuterium-labeled internal standard. Deuterium-labeled internal standards are added to urine which is then diluted prior to analysis. Full scan product ion spectra were obtained in the data-dependent mode using a linear ion trap (ABI 4000 Qtrap). Identification was based on a purity fit of greater than 70. Ninety-seven urine specimens were analyzed by the method described, and results were compared to values obtained from a reference laboratory using selected reaction monitoring (SRM). The ion trap provided about 30-fold increase in signal-to-noise ratio as compared with the same instrument operated in a traditional full scan product ion mode. The assays were linear to at least 10 times the cutoff. Selecting appropriate triggers for obtaining full scan product ion spectra minimized space charging for specimens that contained high concentrations of drugs. There was 100% concordance between the full scan identification and the SRM results for identification of amphetamine, methamphetamine, benzoylecgonine, morphine, codeine, hydrocodone, and hydromorphone. The ability to "dilute and shoot" reduces the turnaround time for results. The data acquired with SRM and full scan product ion spectra provide accurate quantification and a high degree of specificity. Topics: Chromatography, Liquid; Cocaine; Humans; Hydrocodone; Hydromorphone; Ions; Methamphetamine; Reproducibility of Results; Signal-To-Noise Ratio; Substance Abuse Detection; Tandem Mass Spectrometry | 2012 |