germanium and cadmium-telluride

germanium has been researched along with cadmium-telluride* in 2 studies

Other Studies

2 other study(ies) available for germanium and cadmium-telluride

ArticleYear
A new PET scanner with semiconductor detectors enables better identification of intratumoral inhomogeneity.
    Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 2009, Volume: 50, Issue:1

    An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images with high spatial resolution and low scatter noise. Both phantom images and patients' images were analyzed to evaluate intratumoral inhomogeneity.. This study was performed with a cold spot phantom that had 6-mm-diameter cold sphenoid defects, a dual-cylinder phantom with an adjusted concentration of 1:2, and an "H"-shaped hot phantom. These were surrounded with water. Phantom images and (18)F-FDG PET images of patients with nasopharyngeal cancer were compared with conventional bismuth germanate PET images. Profile curves for the phantoms were measured as peak-to-valley ratios to define contrast. Intratumoral inhomogeneity and tumor edge sharpness were evaluated on the images of the patients.. The contrast obtained with the semiconductor PET scanner (1.53) was 28% higher than that obtained with the conventional scanner (1.20) for the 6-mm-diameter cold sphenoid phantom. The contrast obtained with the semiconductor PET scanner (1.43) was 27% higher than that obtained with the conventional scanner (1.13) for the dual-cylinder phantom. Similarly, the 2-mm cold region between 1-mm hot rods was identified only by the new PET scanner and not by the conventional scanner. The new PET scanner identified intratumoral inhomogeneity in more detail than the conventional scanner in 6 of 10 patients. The tumor edge was sharper on the images obtained with the new PET scanner than on those obtained with the conventional scanner.. These phantom and clinical studies suggested that this new PET scanner has the potential for better identification of intratumoral inhomogeneity, probably because of its high spatial resolution and low scatter noise.

    Topics: Adult; Aged; Bismuth; Cadmium Compounds; Carcinoma, Squamous Cell; Female; Germanium; Glucose; Humans; Male; Nasopharyngeal Neoplasms; Neoplasms; Phantoms, Imaging; Positron-Emission Tomography; Semiconductors; Tellurium; Time Factors

2009
The use of cadmium telluride detectors for the qualitative analysis of diagnostic x-ray spectra.
    Physics in medicine and biology, 1984, Volume: 29, Issue:9

    A method is introduced for the evaluation of x-ray spectra from x-ray machines operating in the range 50-100 kVp using a cadmium telluride (CdTe) detector with low detection efficiency. The pulse height distribution obtained with this kind of detector does not represent the true photon spectra owing to the presence of K-escape, Compton scattering, etc.; these effects were evaluated using a Monte Carlo method. A stripping procedure is described for implementation on a Univac 1100/82 computer. The validity of our method was finally tested by comparison with experimental results obtained with a Ge detector and with data from the literature; the results are in good agreement with published data.

    Topics: Cadmium; Cadmium Compounds; Germanium; Monte Carlo Method; Radiography; Radiometry; Technology, Radiologic; Tellurium

1984