Page last updated: 2024-08-18

ethylene dimethacrylate and muramidase

ethylene dimethacrylate has been researched along with muramidase in 7 studies

Research

Studies (7)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's2 (28.57)18.2507
2000's2 (28.57)29.6817
2010's3 (42.86)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Friends, GD; Künzler, JF; Ozark, RM1
Fréchet, JM; Svec, F1
Hahn, R; Jungbauer, A; Merhar, M; Podgomik, A; Schallaun, E1
Armenta, JM; Gu, B; Lee, ML; Thulin, CD1
Chen, W; Crommen, J; Duan, Q; Jiang, Z; Liu, C; Liu, Z; Wang, Q; Zhou, Z1
Masini, JC1
Gao, W; Li, JY; Lian, HZ; Liu, XL; Mao, L1

Other Studies

7 other study(ies) available for ethylene dimethacrylate and muramidase

ArticleYear
High-strength hydrogels based on N-vinyl pyrrolidinone and 4-t-butyl-2-hydroxycyclohexylmethacrylate.
    Journal of biomedical materials research, 1992, Volume: 26, Issue:1

    Topics: Adsorption; Hydrogel, Polyethylene Glycol Dimethacrylate; Methacrylates; Muramidase; Oxygen; Permeability; Polyethylene Glycols; Pyrrolidinones; Spectrophotometry, Ultraviolet

1992
Modified poly(glycidyl methacrylate-co-ethylene dimethacrylate) continuous rod columns for preparative-scale ion-exchange chromatography of proteins.
    Journal of chromatography. A, 1995, May-19, Volume: 702, Issue:1-2

    Topics: Animals; Chickens; Chromatography, High Pressure Liquid; Chromatography, Ion Exchange; Conalbumin; Epoxy Compounds; Methacrylates; Muramidase; Ovalbumin; Proteins; Serum Albumin, Bovine; Trypsin Inhibitors

1995
Affinity monoliths generated by in situ polymerization of the ligand.
    Analytical chemistry, 2001, Nov-01, Volume: 73, Issue:21

    Topics: Chromatography, Affinity; Cross-Linking Reagents; Epoxy Compounds; Ligands; Methacrylates; Muramidase; Peptides; Polymers

2001
Coupled affinity-hydrophobic monolithic column for on-line removal of immunoglobulin G, preconcentration of low abundance proteins and separation by capillary zone electrophoresis.
    Journal of chromatography. A, 2007, Apr-27, Volume: 1148, Issue:1

    Topics: Cytochromes c; Electrophoresis, Capillary; Humans; Hydrophobic and Hydrophilic Interactions; Immunoglobulin G; Methacrylates; Microscopy, Electron, Scanning; Muramidase; Polymers; Proteins; Reproducibility of Results; Serum Albumin; Solid Phase Extraction; Trypsinogen

2007
Preparation and evaluation of a novel monolithic column containing double octadecyl chains for reverse-phase micro high performance liquid chromatography.
    Journal of chromatography. A, 2014, Jun-06, Volume: 1345

    Topics: Animals; Chickens; Chromatography, High Pressure Liquid; Chromatography, Reverse-Phase; Cytochromes c; Ethylene Glycols; Methacrylates; Microscopy, Electron, Scanning; Muramidase; Polycyclic Aromatic Hydrocarbons; Reproducibility of Results; Ribonucleases; Tocopherols

2014
Separation of proteins by cation-exchange sequential injection chromatography using a polymeric monolithic column.
    Analytical and bioanalytical chemistry, 2016, Volume: 408, Issue:5

    Topics: Animals; Cattle; Chickens; Chromatography, Ion Exchange; Cytochromes c; Epoxy Compounds; Horses; Methacrylates; Muramidase; Myoglobin; Polymers; Ribonuclease, Pancreatic

2016
One-pot preparation of zwitterionic sulfoalkylbetaine monolith for rapid and efficient separation of lysozyme from egg white.
    Journal of pharmaceutical and biomedical analysis, 2019, Oct-25, Volume: 175

    Topics: Betaine; Egg White; Hydrogen-Ion Concentration; Hydrophobic and Hydrophilic Interactions; Methacrylates; Muramidase; Nucleosides; Permeability; Phenols; Polymerization; Polymers; Porosity; Static Electricity

2019