cardiovascular-agents has been researched along with umirolimus* in 80 studies
3 review(s) available for cardiovascular-agents and umirolimus
Article | Year |
---|---|
True double bifurcation lesions: new application of the self-expandable Axxess stent and review of literature with dedicated bifurcation devices.
Complex coronary artery bifurcation lesions occurred in hard clinical scenarios, such as acute coronary syndromes, may represent a challenge for interventional cardiologists, with not-defined general consensus on treatment. Even if provisional stenting is the most common option used to restore rapidly the coronary branches flow, improvements in industrial technologies and design of new dedicated bifurcation devices might open new modalities of treatment in these complex cases. The Axxess stent (Biosensors Europe SA, Morges, Switzerland) is a self-expanding biolimus-eluting conical V-shape stent, specifically designed to treat "easily" coronary artery bifurcation lesions, with reported favorable long-term clinical results in stable patients compared to a provisional technique. We report for the first time the feasibility to use this device in a case of "true double coronary bifurcation lesion" occurred in the context of acute coronary syndrome. Moreover, we reviewed studies with bifurcation dedicated devices and available cases of "true double bifurcation lesions", underlying advantages/disadvantages of using one device over the others during acute coronary syndrome. Topics: Acute Coronary Syndrome; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Humans; Male; Prosthesis Design; Sirolimus; Treatment Outcome | 2019 |
Impact of side branch stenting on five-year long-term clinical outcome with the bifurcation-dedicated Axxess Biolimus A9-eluting stent system.
Our aim was to evaluate the five-year clinical impact of side branch (SB) stenting with a drug-eluting stent (DES) following Axxess stent implantation in coronary bifurcation lesions.. Four hundred patients treated with Axxess were pooled from the AXXESS Plus and DIVERGE five-year follow-up studies. We compared unadjusted and propensity-adjusted major adverse clinical events (MACE) between Axxess with no SB stenting ("Axxess provisional") versus Axxess with SB stenting ("Axxess additional"). "Axxess additional" had no impact on the MACE rate, with unadjusted and adjusted HR 1.59 (95% CI: 0.95-2.64) and 1.37 (95% CI: 0.88-2.13), respectively. No differences were seen in the individual components of death, myocardial infarction and ischaemia-driven target lesion revascularisation, respectively, both in unadjusted (HR 0.92 [95% CI: 0.38-2.19]; HR 1.73 [95% CI: 0.78-3.82]; HR 1.65 [95% CI: 0.84-3.26]) and adjusted analysis (HR 0.92 [95% CI: 0.41-2.09]; HR 1.13 [95% CI: 0.59-2.17]; HR 1.31 [95% CI: 0.74-2.31]). No differences in definite stent thrombosis were seen with unadjusted HR 2.1 (95% CI: 0.45-9.88) and adjusted HR 1.0 (95% CI: 0.32-3.1).. Stenting the SB following Axxess implantation does not impact on long-term clinical outcomes compared to MV stenting only. The Axxess stent system offers a safe and tailored alternative for the treatment of coronary bifurcation lesions. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Logistic Models; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFO
This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).. Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Metals; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Randomized Controlled Trials as Topic; Recurrence; Risk Assessment; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2014 |
34 trial(s) available for cardiovascular-agents and umirolimus
Article | Year |
---|---|
Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial.
Given the characteristic differences between intravascular ultrasound (IVUS) and optical frequency domain imaging (OFDI), their approach to therapeutic guidance during percutaneous coronary interventions (PCIs) and arterial healing response after stenting may also vary.. MISTIC-1 (The Multimodality Imaging Study in Cardiology cohort 1) is a multicenter, randomized-controlled, noninferiority trial that compared imaging end points between OFDI- and IVUS-guided PCI. Patients with stable coronary artery disease were randomly assigned to either OFDI- or IVUS-guided PCI using a Biolimus A9-eluting stent according to a prespecified protocol for imaging guidance. Stent sizing was based on external elastic lamina in IVUS-guided PCI while lumen up-size in OFDI-guided PCI. Postprocedural OFDI was investigated regardless of randomization, while operators in IVUS-guided PCI arm were blinded to the images. The primary end point was in-segment minimum lumen area assessed using OFDI at 8 months, while the secondary end point was a composite of cardiovascular mortality, target-vessel myocardial infarction, or target-lesion revascularization (device-oriented composite end point). Patients were followed up to 3 years after the index procedure.. OFDI-guided PCI was not inferior to IVUS-guided PCI in terms of in-segment minimum lumen area at 8 months. Although a small sample size was acknowledged, OFDI could be an alternative to IVUS when considering intracoronary imaging-guided PCI in selected populations with coronary artery diseases. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03292081. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Japan; Male; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2020 |
Impact of diabetes on clinical outcomes after revascularization with sirolimus-eluting and biolimus-eluting stents with biodegradable polymer from the SORT OUT VII trial.
In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared.. Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention.. In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years.. At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95).. TLF did not differ between O-SES- and N-BES-treated diabetic patients. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention: A Randomized Noninferiority Trial With 1-Year Follow-Up (SORT OUT VIII Trial).
The aim of this study was to compare the thin-strut biodegradable-polymer everolimus-eluting platinum-chromium stent (EES) with the biodegradable-polymer biolimus-eluting stainless-steel stent (BES).. Currently available drug-eluting coronary stents have been refined to reduce the risk for coronary events following implantation.. This randomized, multicenter, all-comers, noninferiority trial was undertaken at 3 sites in western Denmark. Patients with clinical indications for percutaneous coronary intervention were eligible for inclusion. Patients were randomly assigned (1:1) to either EES or BES. The primary endpoint, target lesion failure, was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a nontarget lesion) and efficacy (target lesion revascularization) at 12 months, analyzed using intention-to-treat principles. The trial was powered to assess target lesion failure noninferiority of the EES compared with the BES with a predetermined noninferiority margin of 3%.. A total of 1,385 patients were assigned to treatment with EES and 1,369 patients to treatment with BES. The analysis showed that 55 patients (4.0%) assigned to the EES and 60 (4.4%) assigned to the BES met the primary endpoint (absolute risk difference 0.4%; upper limit of 1-sided 95% confidence interval: 1.7%; p < 0.001).. At 1-year follow-up, the EES was found to be noninferior to the BES with respect to target lesion failure. (Everolimus-eluting SYNERGY Stent Versus Biolimus-Eluting Biomatrix NeoFlex Stent-SORT-OUT VIII; NCT02093845). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Denmark; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Two-year outcome after biodegradable polymer sirolimus- and biolimus-eluting coronary stents (from the randomised SORT OUT VII trial).
Topics: Absorbable Implants; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Humans; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy.
There are few randomised studies concerning the optimal duration of dual antiplatelet therapy (DAPT) for patients who receive a second-generation drug-eluting stent (DES). This trial aimed to investigate the safety of six-month compared with 12-month DAPT maintenance after second-generation DES implantation.. A prospective, randomised, multicentre trial was performed at 10 medical centres. The 1,368 patients included in the study received a biolimus-eluting stent (BES) or a zotarolimus-eluting stent (ZES). The primary outcome measured was the composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), or ischaemia-driven target lesion revascularisation at the 12-month follow-up. The secondary outcome was the percentage of uncovered struts at six months in 60 patients (30 ZES, 30 BES) using optical coherence tomography (OCT) assessment. Each patient was randomly assigned to six-month (n=684) or 12-month DAPT (n=684). Major adverse cardiac events at 12 months occurred in eight patients (1.2%) in the six-month DAPT group and in four patients (0.6%) in the 12-month DAPT group (risk difference 0.6%; 95% confidence interval [CI]: -0.4-1.6%; p=0.24). The upper 95% CI limit was lower than the pre-specified limit of 4% non-inferiority (p for non-inferiority <0.05). The percentage of uncovered struts was 3.16±4.30% at six months in 60 stents of 60 patients.. After second-generation DES implantation, six-month DAPT was not inferior to 12-month DAPT in terms of MACE occurrence over the 12-month follow-up period. OCT examination revealed favourable stent strut coverage at six months after stent implantation. Topics: Aged; Aspirin; Cardiovascular Agents; Clopidogrel; Coronary Angiography; Coronary Artery Disease; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Two-year outcomes of high bleeding risk patients with acute coronary syndrome after Biolimus A9 polymer-free drug-coated stents: a LEADERS FREE substudy.
Topics: Acute Coronary Syndrome; Cardiovascular Agents; Double-Blind Method; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Hemorrhage; Humans; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2018 |
Early Strut Coverage in Patients Receiving Drug-Eluting Stents and its Implications for Dual Antiplatelet Therapy: A Randomized Trial.
This study sought to measure early strut coverage in patients receiving drug-eluting stents (DESs) and to explore the feasibility of short-term dual antiplatelet therapy (DAPT) based on the degree of early strut coverage.. Data for early strut coverage in patients receiving new-generation DESs, and its implications for DAPT continuation were limited.. A randomized, multicenter trial was conducted in 894 patients treated with DESs. Patients were randomly assigned to everolimus-eluting stent (EES) (n = 444) or biolimus-eluting stent (BES) (n = 450) groups and optical coherence tomography (OCT)-guided (n = 445) or angiography-guided (n = 449) implantation groups using a 2-by-2 factorial design. Early strut coverage was measured as the percentage of uncovered struts on 3-month follow-up OCT examination. The primary outcome was the difference in early strut coverage between EES and BES groups and between OCT- and angiography-guided implantation groups. The secondary outcome was a composite of cardiac death, myocardial infarction, stent thrombosis, and major bleeding during the first 12 months post-procedure in patients receiving 3-month DAPT based on the presence of early strut coverage (≤6% uncovered) on 3-month follow-up OCT.. Three-month follow-up OCT data were acquired for 779 patients (87.1%). The median percentage of uncovered struts at 3 months was 8.9% and 8.2% in the EES and BES groups, respectively (p = 0.69) and was lower in the OCT-guided group (7.5%) than in the angiography-guided group (9.9%; p = 0.009). Favorable early strut coverage (≤6% uncovered strut) was observed in 320 of 779 patients (41.1%). At 12 months, the composite event rarely occurred in the 3-month (0.3%) or 12-month (0.2%) DAPT groups (p = 0.80).. OCT-guided DES implantation improved early strut coverage compared with angiography-guided DES implantation, with no difference in strut coverage between EES and BES groups. Short-term DAPT may be feasible in selected patients with favorable early strut coverage (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of The Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus-eluting Stents Versus Biolimus A9-eluting Stents [DETECT-OCT]; NCT01752894). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Everolimus; Feasibility Studies; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Republic of Korea; Risk Factors; Sirolimus; Stroke; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
5-Year clinical follow-up of the COBRA (complex coronary bifurcation lesions: Randomized comparison of a strategy using a dedicated self-expanding biolimus A9-eluting stent vs. a culotte strategy using everolimus-eluting stents) study.
We evaluated healing responses with optical coherence tomography, and long-term clinical outcomes after treatment with a dedicated stent versus a conventional culotte technique.. Dedicated bifurcation stents have been proposed as an alternative treatment for coronary bifurcation lesions. The long-term performance of dedicated stents versus conventional dual-stent techniques for the treatment of complex coronary bifurcation lesions is unknown.. Forty patients with true coronary bifurcation lesions were randomized to treatment with a dedicated Axxess bifurcation stent in the proximal main vessel and additional Biomatrix stents in branches versus culotte stenting using Xience stents.. The percentage of uncovered struts in each bifurcation segment at 9 months (primary endpoint) was similar between groups. Five-year clinical follow-up was available for all patients and included major adverse cardiac events [MACE; a composite of cardiac death, myocardial infarction (MI) and ischemia-driven target lesion revascularization (TLR)], target-vessel (TVR) and non-target-vessel revascularization (non-TVR), non-TLR and stent thrombosis. At 5 years, in the culotte group, one patient had undergone TLR and another suffered a clinical MI, resulting in 10% MACE versus none in the Axxess group. TVR (5% vs. 10%, P = 0.54) and non-TVR (5% vs. 20%, P = 0.39) rates were similar between the Axxess and culotte groups, respectively. There was no stent thrombosis.. Compared with culotte stenting with Xience, complex coronary bifurcation stenting using a dedicated strategy combining the Axxess and Biomatrix stents results in similar stent strut coverage at 9 months, and excellent clinical outcomes at 5 years. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.
Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer.. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size.. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Hong Kong; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Early Follow-Up Optical Coherence Tomographic Findings of Significant Drug-Eluting Stent Malapposition.
Using optical coherence tomography, we evaluated early follow-up findings of significant stent malapposition (SSM) in patients treated with second-generation drug-eluting stent.. From the DETECT-OCT randomized trial (Determination of the Duration of the Dual Antiplatelet Therapy by the Degree of the Coverage of the Struts on Optical Coherence Tomography From the Randomized Comparison Between Everolimus- Versus Biolimus-Eluting Stent), a total of 386 patients (390 lesions) who underwent both postintervention and 3-month follow-up optical coherence tomography examinations were included for the present analysis. SSM was defined as a stent that had a strut with a maximal wall-to-strut distance of ≥200 μm. Postintervention, SSM was detected in 175 lesions (44.9%), including 117 lesions with a maximal wall-to-strut distance of ≥200 to <400 μm and 58 lesions with a maximal wall-to-strut distance of ≥400 μm. As the implanted stent diameter-to-reference vessel diameter ratio grew, the risk of postintervention SSM dropped (odds ratio, 0.587; 95% CI, 0.367-0.941; P=0.0398). The optimal value that best separated SSM from non-SSM postintervention was a stent diameter-to-reference vessel diameter ratio of 1.0. At 3 months follow-up, the frequency of SSM decreased from 44.9% to 33.6% (131 lesions; P=0.0001), mainly driven by the decrease in lesions with a maximal wall-to-strut distance of ≥200 to <400 μm. As the maximal wall-to-strut distance on postintervention optical coherence tomography was larger, the risk of 3-month SSM increased (odds ratio, 1.607; 95% CI, 1.131-2.286; P=0.0284). The optimal value that best separated SSM from non-SSM at 3 months follow-up was a maximal wall-to-strut distance postintervention of 230 μm.. A spontaneous decrease in SSM was observed early in this qualified study with a large number of study patients treated with second-generation drug-eluting stent.. URL: https://www.clinicaltrials.gov . Unique identifier: NCT01752894. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2018 |
Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable P
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention.. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce.. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization.. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17).. The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Rehospitalizations Following Primary Percutaneous Coronary Intervention in Patients With ST-Elevation Myocardial Infarction: Results From a Multi-Center Randomized Trial.
Rehospitalizations (RHs) after ST-elevation myocardial infarction carry a high economic burden and may deteriorate quality of life. Characterizing patients at higher risk may allow the design of preventive measures. We studied the frequency, reasons, and predictors for unplanned cardiac and noncardiac RHs in ST-elevation myocardial infarction patients undergoing primary percutaneous coronary intervention.. In this post-hoc analysis of the COMFORTABLE AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction; NCT00962416) trial including 1137 patients, unplanned cardiac and noncardiac RHs occurred in 133 (11.7%) and in 79 patients (6.9%), respectively, at 1 year. The most frequent reasons for unplanned cardiac RHs were recurrent chest pain without evidence of ischemia (20.4%), recurrent chest pain with ischemia and coronary intervention (16.9%), and ischemic events (16.9%). Unplanned noncardiac RHs occurred most frequently attributed to bleeding (24.5%), infections (14.3%), and cancer (9.1%). On multivariate analysis, left ventricular ejection fraction (22% increase in the rate of RHs per 10% decrease;. Among ST-elevation myocardial infarction patients undergoing primary percutaneous coronary intervention in the setting of a randomized, clinical trial, unplanned cardiac RHs occurred in 12% with recurrent chest pain being the foremost reason. Unplanned noncardiac RHs occurred in 7% with bleeding as the leading cause. Left ventricular ejection fraction and Syntax score were independent predictors of unplanned cardiac RHs and identified patient subgroups in need for improved secondary prevention.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00962416. Topics: Absorbable Implants; Age Factors; Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Drug-Eluting Stents; Europe; Female; Humans; Israel; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Patient Readmission; Percutaneous Coronary Intervention; Prosthesis Design; Risk Factors; Sirolimus; ST Elevation Myocardial Infarction; Stroke Volume; Time Factors; Treatment Outcome; Ventricular Function, Left | 2017 |
Safety and Efficacy of Polymer-Free Biolimus A9-Coated Versus Bare-Metal Stents in Orally Anticoagulated Patients: 2-Year Results of the LEADERS FREE Oral Anticoagulation Substudy.
The aim of this study was to compare the performance of drug-coated stents (DCS) versus bare-metal stents (BMS) in patients who are candidates for long-term oral anticoagulation (OAC) after percutaneous coronary interventions.. The randomized controlled LEADERS FREE (A Randomized Clinical Evaluation of the BioFreedom™ Stent) trial demonstrated the superior safety and efficacy of a polymer-free biolimus A9 DCS compared with a similar BMS used with 1 month of dual antiplatelet therapy in 2,466 patients at high bleeding risk.. The 2 stents were compared in a pre-specified analysis of the 879 LEADERS FREE patients (35.6%) scheduled to remain on OAC after percutaneous coronary intervention. The primary safety endpoint was a composite of cardiac death, myocardial infarction, and stent thrombosis. The primary efficacy endpoint was the incidence of clinically driven target lesion revascularization.. Baseline characteristics of 448 DCS and 431 BMS recipients were similar, 78.8% had histories of atrial fibrillation, and 21% presented with acute coronary syndromes. Four hundred patients in the DCS group and 376 in the BMS group were discharged on OAC after percutaneous coronary intervention. At 2 years, for the DCS and BMS recipients, respectively, the incidence of clinically driven target lesion revascularization was 7.5% versus 11.2% (hazard ratio: 0.63; 95% confidence interval: 0.40 to 1.01; p = 0.0514), the safety endpoint was reached by 14.4% and 15.0% (p = NS), and the rates of major bleeding events (Bleeding Academic Research Consortium 3 to 5) were 10.7% and 12.9% (p = NS).. The efficacy advantage of DCS over BMS up to 2 years appears confirmed in patients on long-term OAC. Despite the very short course of dual antiplatelet therapy, both the DCS and BMS groups experienced similarly high rates of major bleeding. (A Randomized Clinical Evaluation of the BioFreedom™ Stent [Leaders Free]; NCT01623180). Topics: Acute Coronary Syndrome; Administration, Oral; Aged; Aged, 80 and over; Anticoagulants; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Double-Blind Method; Drug-Eluting Stents; Female; Hemorrhage; Humans; Kaplan-Meier Estimate; Male; Metals; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Stents; Time Factors; Treatment Outcome | 2017 |
Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents.
Our aim was to report the long-term safety and efficacy of the biodegradable polymer-coated biolimus- eluting Nobori stent compared to the durable polymer-coated sirolimus-eluting CYPHER stent.. SORT OUT V randomised 2,468 patients 1:1 to the Nobori (n=1,229) versus the CYPHER stent (n=1,239). Clinically driven event detection based on Danish registries was used. The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation). Individual components of the primary endpoint comprise the secondary endpoints. At five-year follow-up, the composite endpoint rate was found to be similar in patients treated with the two study stents (Nobori 182/1,229 [14.8%] vs. CYPHER 197/1,239 [15.8%]; odds ratio [OR] 0.93, 95% CI: 0.75-1.16; p=0.53). The rates of definite stent thrombosis were also found to be similar in patients treated with the two study stents (Nobori 23/1,229 [1.9%] vs. CYPHER 18/1,239 [1.5%]; OR 1.31, 95% CI: 0.70-2.47; p=0.40), as were the other secondary endpoints.. At five-year follow-up, the Nobori stent with a biodegradable polymer coating provided a similar safety and efficacy profile when compared to the durable polymer first-generation CYPHER stent. Topics: Absorbable Implants; Acute Coronary Syndrome; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Incidence; Male; Middle Aged; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Recurrence; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.
We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern. Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Metals; Neointima; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2017 |
Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial.
The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients.. Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking.. The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months.. From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33).. At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Denmark; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
First generation versus second generation drug-eluting stents for the treatment of bifurcations: 5-year follow-up of the LEADERS all-comers randomized trial.
Historically, percutaneous coronary intervention (PCI) of bifurcation lesions was associated with worse procedural and clinical outcomes when compared with PCI of non-bifurcation lesions. Newer generation drug-eluting stents (DES) might improve long-term clinical outcomes after bifurcation PCI.. The LEADERS trial was a 10-center, assessor-blind, non-inferiority, all-comers trial, randomizing 1,707 patients to treatment with a biolimus A9(TM) -eluting stent (BES) with an abluminal biodegradable polymer or a sirolimus-eluting stent (SES) with a durable polymer (ClinicalTrials.gov Identifier: NCT00389220). Five-year clinical outcomes were compared between patients with and without bifurcation lesions and between BES and SES in the bifurcation lesion subgroup. There were 497 (29%) patients with at least 1 bifurcation lesion (BES = 258; SES = 239). At 5-year follow-up, the composite endpoint of cardiac death, myocardial infarction (MI) and clinically-indicated (CI) target vessel revascularization (TVR) was observed more frequently in the bifurcation group (26.6% vs. 22.4%, P = 0.049). Within the bifurcation lesion subgroup, no differences were observed in (cardiac) death or MI rates between BES and SES. However, CI target lesion revascularization (TLR) (10.1% vs. 15.9%, P = 0.0495), and CI TVR (12.0% vs. 19.2%, P = 0.023) rates were significantly lower in the BES group. Definite/probable stent thrombosis (ST) rate was numerically lower in the BES group (3.1% vs. 5.9%, P = 0.15). Very late (>1 year) definite/probable ST rates trended to be lower with BES (0.4% vs. 3.1%, P = 0.057).. In the treatment of bifurcation lesions, use of BES led to superior long-term efficacy compared with SES. Safety outcomes were comparable between BES and SES, with an observed trend toward a lower rate of very late definite/probable ST between 1 and 5 years with the BES. © 2015 Wiley Periodicals, Inc. Topics: Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2016 |
Polymer-Free Biolimus A9-Coated Stents in the Treatment of De Novo Coronary Lesions: 4- and 12-Month Angiographic Follow-Up and Final 5-Year Clinical Outcomes of the Prospective, Multicenter BioFreedom FIM Clinical Trial.
The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions.. The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland).. A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany.. Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported.. The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119). Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Germany; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Neointima; Paclitaxel; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Single-Blind Method; Sirolimus; Stainless Steel; Surface Properties; Time Factors; Treatment Outcome | 2016 |
Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial.
Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy.. The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05).. The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year.. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chromium Alloys; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Intention to Treat Analysis; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Registries; Risk Factors; Scandinavian and Nordic Countries; Single-Blind Method; Sirolimus; Stainless Steel; Time Factors; Treatment Outcome | 2016 |
Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction.
To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up.. The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up.. The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES.. BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up.. NCT 00389220. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Angiography; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Predictive Value of Tests; Prosthesis Design; Recurrence; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.
To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating.. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year.. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups.. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. Topics: Absorbable Implants; Aged; Brazil; Cardiovascular Agents; Coated Materials, Biocompatible; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Comparison of everolimus-eluting and biolimus-eluting coronary stents with everolimus-eluting bioresorbable scaffold: study protocol of the randomized controlled EVERBIO II trial.
Second-generation everolimus-eluting stents (EES) and third generation biolimus-eluting stents (BES) have been shown to be superior to first-generation paclitaxel-eluting stents (PES) and second-generation sirolimus-eluting stents (SES). However, neointimal proliferation and very late stent thrombosis is still an unresolved issue of drug-eluting stent (DES) implantation overall. The Absorb™ (Abbott Vascular, Abbott Park, IL, USA) is the first CE approved DES with a bioresorbable vascular scaffold (BVS) thought to reduce long-term complication rates. The EVERBIO II trial was set up to compare the BVS safety and efficacy with both EES and BES in all patients viable for inclusion.. The EVERBIO II trial is a single-center, assessor-blinded, randomized trial. The study population consists of all patients aged≥18 years old undergoing percutaneous coronary intervention. Exclusion criterion is where the lesion cannot be treated with BVS (reference vessel diameter>4.0 mm). A total of 240 patients will be enrolled and randomly assigned into 3 groups of 80 with either BVS, EES or BES implantation. All patients will undergo a follow-up angiography study at 9 months. Clinical follow-up for up to 5 years will be conducted by telephone. The primary endpoint is in-segment late lumen loss at 9 months measured by quantitative coronary angiography. Secondary endpoints are patient-oriented major adverse cardiac event (MACE) (death, myocardial infarction and target-vessel revascularization), device-oriented MACE (cardiac death, myocardial infarction and target-lesion revascularization), stent thrombosis according to ARC and binary restenosis at follow-up 12 months angiography.. EVERBIO II is an independent, randomized study, aiming to compare the clinical efficacy, angiographic outcomes and safety of BVS, EES and BES in all comer patients.. The trial listed in clinicaltrials.gov as NCT01711931. Topics: Absorbable Implants; Cardiovascular Agents; Clinical Protocols; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Humans; Myocardial Infarction; Percutaneous Coronary Intervention; Prosthesis Design; Research Design; Sirolimus; Switzerland; Time Factors; Tissue Scaffolds; Treatment Outcome | 2014 |
Randomised comparison of strut coverage between Nobori biolimus-eluting and sirolimus-eluting stents: an optical coherence tomography analysis.
The aims of this study were to compare strut tissue coverage at six-month follow-up after Nobori biolimus-eluting stent (N-BES) versus sirolimus-eluting stent (SES) implantation.. A total of 120 patients with a single stenotic lesion requiring revascularisation were randomly assigned to either N-BES (n=60) or SES (n=60). Baseline optical coherence tomography (OCT) was performed post stent implantation, and follow-up OCT was scheduled at six months. Post-intervention and follow-up OCT analyses were available in 51 (85.0%) and 52 (86.7%) patients, respectively. The primary endpoint was the percentage of uncovered struts at follow-up OCT in all cross-sections with analysis of 0.2 mm longitudinal intervals. In addition, an OCT contour plot analysis was constructed to investigate the distribution patterns of uncovered struts. The percentage of uncovered struts of N-BES was significantly lower versus SES (15.9±12.2% versus 25.1±18.3%, respectively, p=0.003). N-BES showed a greater NIH thickness than SES (median [interquartile range] 52.4 μm [41.9-74.9] versus 42.1 μm [30.6-56.0], p=0.005). Contour plot analyses showed a lower incidence of a diffuse distribution pattern of uncovered struts (46.8% versus 75.0%, respectively, p=0.022).. This randomised OCT study showed that N-BES had a significantly lower percentage of uncovered struts, and less common diffuse distribution pattern of uncovered struts versus SES. Topics: Aged; Cardiovascular Agents; Coronary Stenosis; Coronary Vessels; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Republic of Korea; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2014 |
Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus
This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial.. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES.. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat.. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005).. The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Topics: Absorbable Implants; Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Europe; Female; Humans; Intention to Treat Analysis; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Odds Ratio; Percutaneous Coronary Intervention; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
Randomized comparison of the Nobori biolimus A9-eluting stent with the sirolimus-eluting stent in patients with stenosis in native coronary arteries.
The aim of this randomized-controlled trial is to compare biolimus A9-eluting stent (Nobori) to sirolimus eluting stent (Cypher).. The Nobori coronary stent is coated only abluminally with a biodegradable polymer, poly-lactic acid, and the antiproliferative agent biolimus A9. This stent has been studied in randomized trials versus Taxus Express and Taxus Liberte and showed noninferiority and superiority for in-stent late loss. This is the first randomized trial of Nobori stent versus Cypher stent.. We conducted a randomized (3:2), controlled trial comparing Nobori and Cypher, in 335 patients (198 Nobori and 137 Cypher) at 15 centers in Japan. Patients with de-novo lesions in up to two native coronary arteries were considered for enrollment. The primary endpoint was freedom from target vessel failure (TVF), a composite of cardiac death, myocardial infarction, and target vessel revascularization at 9 months.. At 9 months, the primary endpoint of freedom from TVF was 92.6% in Nobori and 93.8% in Cypher arm (noninferiority test P < 0.001). As main secondary endpoints, the in-stent late loss was 0.12 ± 0.30 mm and 0.14 ± 0.34 mm in Nobori and Cypher stents, respectively. Target lesion revascularization was 0.5% in Nobori and 3.9% in Cypher treated patients (P = 0.04). Definite and probable stent thromboses were not recorded in any patient.. Despite the relatively small number of patients, this well controlled clinical trial confirmed the primary hypothesis of non-inferiority of the Nobori biolimus A9-eluting stent to the Cypher sirolimus-eluting stent for freedom from TVF. Both stents showed excellent midterm results. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Japan; Lactic Acid; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polyesters; Polymers; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome | 2012 |
2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up.. BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegradation of the polymer used for drug release and after discontinuation of dual antiplatelet therapy are of particular interest.. A total of 1,707 patients were randomized to unrestricted use of BES (n = 857) or SES (n = 850) in an all-comers patient population.. At 2 years, BES remained noninferior compared with SES for the primary endpoint, which was a composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularization (BES 12.8% vs. SES 15.2%, hazard ratio [HR]: 0.84, 95% confidence interval [CI]: 0.65 to 1.08, p(noninferiority) < 0.0001, p(superiority) = 0.18). Rates of cardiac death (3.2% vs. 3.9%, HR: 0.81, 95% CI: 0.49 to 1.35, p = 0.42), myocardial infarction (6.3% vs. 5.6%, HR: 1.12, 95% CI: 0.76 to 1.65, p = 0.56), and clinically indicated target vessel revascularization (7.5% vs. 8.6%, HR: 0.86, 95% CI: 0.62 to 1.20, p = 0.38) were similar for BES and SES. The rate of definite stent thrombosis through 2 years was 2.2% for BES and 2.5% for SES (p = 0.73). For the period between 1 and 2 years, event rates for definite stent thrombosis were 0.2% for BES and 0.5% for SES (p = 0.42). After discontinuation of dual antiplatelet therapy, no very late definite stent thrombosis occurred in the BES group.. At 2 years of follow-up, the unrestricted use of BES with a biodegradable polymer maintained a similar safety and efficacy profile as SES with a durable polymer. (Limus Eluted From a Durable Versus Erodable Stent Coating [LEADERS]; NCT00389220). Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Survival Rate; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Implantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score is associated with decreased cardiac mortality compared to a permanent polymer sirolimus-eluting stent: two year follow-up results from the "all-comers" LE
The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI).. The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 8 Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Heart Diseases; Humans; Male; Middle Aged; Polymers; Proportional Hazards Models; Prospective Studies; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2011 |
The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).
The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES).. One thousand seven hundred and seven patients were randomised to unrestricted use of BES (n=857) or SES (n=850) in an all-comers population. Three year follow-up was available in 95% of the patients, 812 treated with BES and 809 treated with SES. At three years, BES remains non-inferior to SES for the primary endpoint of major adverse cardiac events (composite of cardiac death, myocardial infarction (MI), or clinically-indicated target vessel revascularisation (CI-TVR) (BES 15.7% versus SES 19%; HR 0.82 CI 0.65-1.03; p=0.09). The MACE Kaplan Meier event curves increasingly diverge with the difference in events increasing from 1.4% to 2.4% and 3.3% at 1, 2 and 3 years, respectively in favour of BES. The rate of cardiac death was non-significantly lower 4.2% versus 5.2% (HR=0.81 CI 0.52-1.26; p=0.34) and the rate of myocardial infarction was equivalent 7.2% versus 7.1% (HR 1.01 CI 0.70-1.44; p=0.97) for BES versus SES, respectively. Thus BES was non-inferior to SES in all the safety endpoints. Clinically-indicated TVR occurred in 9.4% of BES treated patients versus 11.1% of SES treated patients (HR 0.84 CI 0.62-1.13; p=0.25). Rates of definite stent thrombosis were 2.2% for BES and 2.9% for SES (HR 0.78 CI 0.43-1.43; p=0.43), with the event rate increase of 0.2% from one to three years for BES and 0.9% for SES. For patients presenting with ST-elevation myocardial infarction BES was superior to SES in reducing MACE.. The findings of the three year follow-up support the claim that the biodegradable polymer biolimus-eluting stent has equivalent safety and efficacy to permanent polymer sirolimus-eluting stent in an all-comers patient population. Its performance is superior in some subpopulations such as in ST-elevation MI patients and event rates for BES are overall lower than for SES with a trend toward increasing divergence of outcomes over three years. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Drug Therapy, Combination; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Platelet Aggregation Inhibitors; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2011 |
Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial.
To assess the efficacy of the AXXESS stent on the treatment of left main coronary artery (LMCA) bifurcation lesions using IVUS.. The treatment of LMCA bifurcation lesions remains challenging even with the use of drug-eluting stents. The AXXESS system is a biolimus A9-eluting self-expanding stent, dedicated to the treatment of bifurcation lesions.. Data were obtained from the AXXENT trial, a prospective, single-arm, multicenter study designed to evaluate the efficacy of the AXXESS stent on the treatment of LMCA bifurcation lesions. IVUS was available in 26 cases at 6-months follow-up. Volumetric and cross-sectional analyses within the AXXESS stent, and cross-sectional analyses at the ostia of left anterior descending (LAD) and left circumflex coronary arteries (LCX) were performed.. Within the AXXESS stent, percent neointimal volume obstruction was (3.0 +/- 4.1)% with a minimal lumen area of 10.3 +/- 2.6 mm(2). AXXESS stent volume showed an 12.4% increase at follow-up compared with postprocedure (P = 0.04). Lumen area was significantly smaller in the LCX ostium compared with the LAD ostium at follow-up (3.6 +/- 1.3 mm(2) vs. 5.5 +/- 2.0 mm(2), P = 0.0112). There was greater neointimal formation in the LCX ostium compared with the LAD ostium (1.37 +/- 1.20 mm(2) vs. 0.30 +/- 0.36 mm(2), P = 0.0003).. The AXXESS stent in the LMCA showed enlargement through 6-months follow-up and significant neointimal suppression. Greater neointimal formation and relatively inadequate stent expansion may contribute to luminal narrowing in the LCX ostium. Topics: Aged; Alloys; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Prospective Studies; Prosthesis Design; Sirolimus; Stents; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional; United States | 2009 |
Biolimus-eluting biodegradable polymer versus sirolimus-eluting permanent polymer stent performance in long lesions: results from the LEADERS multicentre trial substudy.
Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions.. A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group.. BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment. Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Male; Middle Aged; Myocardial Infarction; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Impact of vessel size on angiographic and clinical outcomes of revascularization with biolimus-eluting stent with biodegradable polymer and sirolimus-eluting stent with durable polymer the LEADERS trial substudy.
We assessed the impact of vessel size on outcomes of stenting with biolimus-eluting degradable polymer stent (BES) and sirolimus-eluting permanent polymer stent (SES) within a randomized multicenter trial (LEADERS).. Stenting of small vessels might be associated with higher rates of adverse events.. "All-comer" patients (n = 1,707) were randomized to BES and SES. Post-hoc-stratified analysis of angiographic and clinical outcomes at 9 months and 1 year, respectively, was performed for vessels with reference diameter Topics: Absorbable Implants; Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Europe; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Polymers; Proportional Hazards Models; Prosthesis Design; Risk Assessment; Severity of Illness Index; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Randomized comparison of the Nobori Biolimus A9-eluting coronary stent with the Taxus Liberté paclitaxel-eluting coronary stent in patients with stenosis in native coronary arteries: the NOBORI 1 trial--Phase 2.
The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation.. We conducted a randomized (2:1), controlled trial comparing the Biolimus A9-eluting stent Nobori and the paclitaxel-eluting stent Taxus Liberté, in 243 patients (153 Nobori and 90 Taxus) at 29 centers in Europe, Asia, and Australia. Patients with previously untreated lesions in up to 2 native coronary arteries were considered for enrollment. The primary end point was in-stent late loss at 9 months, whereas secondary end points included other quantitative coronary angiography parameters, such as in-segment late loss and the rate of restenosis as well as key intravascular ultrasound parameters. Clinical secondary end points were stent thrombosis and composite of major adverse cardiac events comprising death, myocardial infarction, and target vessel revascularization. At 9 months, the in-stent late loss was significantly lower in the Nobori group compared with the Taxus group (0.11+/-0.30 mm versus 0.32+/-0.50 mm) reaching both the primary hypothesis of noninferiority of Nobori stent versus Taxus Liberté stent (P<0.001) and the secondary hypothesis of superiority (P=0.001). This finding was confirmed by a significant reduction in binary restenosis from 6.2% in Taxus to 0.7% in Nobori (P=0.02) and neointimal volume obstruction, detected by intravascular ultrasound, from 5.5+/-7.2% in Taxus to 1.8+/-5.2% in Nobori (P=0.01). The major adverse cardiac events rate was 4.6% in the Nobori and 5.6% in the Taxus cohort of patients. The stent thrombosis rate was 0% in the Nobori arm and 4.4% in the Taxus arm.. The NOBORI 1 clinical trial confirmed its primary hypothesis--noninferiority of the Nobori Biolimus A9-eluting stent versus the Taxus Liberté stent in reducing neointimal proliferation. Both stents showed a low major adverse cardiac events rate in the studied population. Topics: Angioplasty, Balloon, Coronary; Asia; Australia; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Europe; Female; Humans; Hyperplasia; Male; Middle Aged; Myocardial Infarction; Paclitaxel; Prospective Studies; Risk Assessment; Sirolimus; Thrombosis; Time Factors; Treatment Outcome; Ultrasonography, Interventional | 2009 |
The pharmacokinetics of Biolimus A9 after elution from the Nobori stent in patients with coronary artery disease: the NOBORI PK study.
The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents.. : The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents.. Twenty patients with coronary artery disease were treated with single 14-mm (10 patients) or 28-mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay.. At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters.. Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Chromatography, Liquid; Colorado; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Prospective Studies; Prosthesis Design; Serbia; Sirolimus; Tandem Mass Spectrometry; Treatment Outcome | 2008 |
Analysis of bifurcation lesions treated with novel drug-eluting dedicated bifurcation stent system: intravascular ultrasound results of the AXXESS PLUS trial.
The aim of this intravascular ultrasound (IVUS) study was to assess the efficacy of the AXXESS Plus stent system for the treatment of bifurcation coronary lesions.. The AXXESS Plus is a novel bifurcation drug-eluting stent, comprised of a self-expanding flare-shaped stent platform and bioabsorbable polymer coating that releases Biolimus A9.. Data were obtained from the AXXESS PLUS trial, a prospective, multicenter, nonrandomized, single-arm study to evaluate safety and efficacy. Six-month follow-up IVUS analysis was available in 49 cases. Volumetric analysis using Simpson's method within the AXXESS stent, and cross-sectional analysis at the ostium of main branch and/or side branch was performed. Impact of bifurcation angle on stent expansion at the carina was also evaluated.. Within the AXXESS stent, neointimal volume obstruction percentage was 2.3% +/- 2.2%, with a minimum lumen area of 7.9 +/- 2.6 mm(2). Lumen area was 5.2 +/- 1.7 mm(2) at main branch ostium, and 4.0 +/- 1.5 mm(2) at side branch ostium. In two cases, incomplete stent apposition was observed at the proximal edge of the AXXESS stent. In one case, a gap between the AXXESS stent and an additional stent was observed. Greater bifurcation angle inversely correlated with smaller stent area at side branch ostium (r = -0.54, P = 0.03) but not at main branch ostium (r = -0.2, P = 0.29).. This novel self-expanding, drug-eluting bifurcation stent demonstrated effective lesion coverage along with significant neointimal suppression equivalent to current generation balloon-expandable drug-eluting stent technology. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Hyperplasia; Male; Middle Aged; Prospective Studies; Prosthesis Design; Sirolimus; Time Factors; Treatment Outcome; Tunica Intima; Ultrasonography, Interventional | 2007 |
43 other study(ies) available for cardiovascular-agents and umirolimus
Article | Year |
---|---|
Real-world reasons and outcomes for 1-month versus longer dual antiplatelet therapy strategies with a polymer-free BIOLIMUS A9-coated stent.
A large trial established the favorable profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a 1-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. This is the first study comparing outcomes for a 1-month versus longer DAPT strategies following PF-BES-percutaneous coronary intervention (PCI).. All patients undergoing PF-BES-PCI (January 2016 to July 2018) were included in the multicenter CHANCE registry. Patients were stratified according to DAPT strategy at discharge (planned 1-month vs. planned >1-month). Primary outcomes were the 390-day estimates of a patient-oriented and of a device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularization; DOCE: cardiac death, target vessel-MI or ischemia-driven target lesion revascularization). Landmark analyses from 1-month post-PCI were carried.. Following PF-BES-PCI, 328(40.3%) and 485(59.6%) patients were discharged with 1-month and longer DAPT (12 months [6-12]), respectively. Patients with a previous or index MI were less likely to be discharged on 1-month DAPT. Patients prescribed with 1-month DAPT were more likely to be at HBR than those with longer DAPT (90.2% vs. 69.9%, p = .001). No between-groups differences in the primary outcomes (planned 1-month vs. planned >1-month DAPT: POCE 11.9% vs. 13.2%, p = .747; DOCE: 4.8% vs. 8.1%, p = .500) were observed, also after adjusting for confoundings (POCE: adjusted-hazard ratio [adj-HR] 1.26, 95%CI 0.74-2.13; DOCE: adj-HR 1.00, 95%CI 0.49-1.99). Landmark analyses showed similar results.. In a large all-comers registry of PF-BES PCI, no interaction of planned DAPT strategy (1-month vs. >1-month) with outcomes was found. This observation warrants investigation in adequately powered randomized studies (ClinicalTrials.gov NCT03622203). Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Drug Administration Schedule; Drug-Eluting Stents; Dual Anti-Platelet Therapy; Female; Humans; Italy; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Prosthesis Design; Registries; Sirolimus; Time Factors; Treatment Outcome | 2020 |
Safety and efficacy of polymer-free biolimus-eluting stents versus ultrathin stents in unprotected left main or coronary bifurcation: A propensity score analysis from the RAIN and CHANCE registries.
Evaluate safety and efficacy of polymer-free biolimus-eluting stents (PF-BESs) versus ultrathin stents in unprotected left main (ULM) or bifurcation.. PF-BESs due to reduced length of dual antiplatelet therapy (DAPT) are increasingly used. However, there are limited data about safety and efficacy for ULM or bifurcation.. We selected all-patients treated for ULM or bifurcation from two multicenter real life registries (RAIN [NCT03544294] evaluating ultrathin stents, CHANCE [NCT03622203] appraising PF-BES). After propensity score with matching, the primary endpoint was major adverse cardiac events (MACE; a composite of all-cause death, myocardial infarction, target lesion revascularization [TLR], and stent thrombosis [ST]), while its components along with target vessel revascularization (TVR) secondary endpoints.. Three thousand and three patients treated with ultrathin stents and 446 with PF-BESs, resulting respectively in 562 and 281 after propensity score with matching (33 and 22%, respectively, with ULM disease). After 12 (8-20) months, rates of MACE were similar (9 vs. 8%, p = 0.56) without difference in TLR and ST (3.0 vs. 1.7%, p = .19 and 1.8 vs. 1.1%, p = .42). These results were consistent for ULM group (3 vs. 1.7% and 1.8 vs. 1.1%, p = .49 and .76), for non-ULM group (2.1 vs. 3.4%, p = .56 and 1.2 vs. 1.7%, p = .78) and for two-stent strategy (8.7 vs. 4.5% and 4.3 vs. 3.2%, p = .75 and .91). Among patients treated with 1 month of DAPT in both groups, those with ultrathin stents experienced higher rates of MACE related to all-cause death (22 vs. 12%, p = .04) with higher although not significant rates of ST (3 vs. 0%, p = .45).. PF-BES implanted on ULM or BiF offered freedom from TLR and ST comparable to ultrathin stents. PF-BESs patients assuming DAPT for 1 month experienced a lower despite not significant incidence of ST. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Clinical Protocols; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Propensity Score; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors | 2020 |
Application of the MADS classification system in a "mega mammoth" stent trial: Feasibility and preliminary clinical implications.
We attempted to test the feasibility of application of the MADS classification system in the largest stent trial to date and evaluate the preliminary clinical implications of this approach.. In the randomized GLOBAL LEADERS trial, testing two different antiplatelet strategies in patients undergoing PCI with bivalirudin and biolimus-eluting stents, the e-CRF was dedicated to bifurcation treatment according to the MADS classification. Based on this e-CRF, the techniques used for bifurcations treatment in GLOBAL LEADERS were described and compared with two large, all-comer registries of bifurcations treatment (I-BIGIS and COBIS), used as historical controls.. Among 15,991 patients enrolled in the trial, 22,921 lesions treated at the index and staged procedure were available for analysis and 2,757 of these lesions were bifurcations and 7 were trifurcation lesions. The e-CRF-based MADS classification was achieved in 2,757 of these lesions (100%). 80.3% of bifurcations were treated using a single stent, 18.9% using 2 stents and 0.7% using 3 stents. Overall, the "main across side first" approach (A) was used in 77.4% with the "side branch first" approach (S) being the second most frequently used technique (10.2%). A single stent was used in the majority of the "A" approach (87.9%). A reduction in the use of 2-stent techniques (from 33.9 to 18.9%) was observed between GLOBAL LEADERS and I-BIGIS. The "A" approach was the most frequently used technique in GLOBAL LEADERS, while in COBIS the "S" strategy was most frequently employed.. Application of the MADS classification through an e-CRF was feasible in the largest stent trial today and provided useful information about the trends observed overtime in the treatment of bifurcation lesions. Topics: Antithrombins; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Feasibility Studies; Hirudins; Humans; Peptide Fragments; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prosthesis Design; Randomized Controlled Trials as Topic; Recombinant Proteins; Sirolimus; Terminology as Topic; Treatment Outcome | 2019 |
Impact of Diabetes on Clinical Outcomes After Polymer-Free Amphilimus- and Biolimus-Eluting Stent Implantation.
Topics: Cardiovascular Agents; Coronary Artery Disease; Diabetes Mellitus; Drug-Eluting Stents; Humans; Italy; Percutaneous Coronary Intervention; Prosthesis Design; Registries; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2019 |
Angiographic and clinical performance of polymer-free biolimus-eluting stent in patients with ST-segment elevation acute myocardial infarction in a metropolitan public hospital: The BESAMI MUCHO study.
This study aimed at assessing the performance of a new generation polymer-free biolimus-eluting stent (BES) in real-world patients with ST-segment elevation myocardial infarction (STEMI).. Polymers components of early-generation drug-eluting stents have been implicated in the pathogenesis of delayed arterial healing, vessel remodeling, and delayed stent thrombosis. Recently, a novel polymer-free BES has shown excellent clinical performance in clinical trial setting.. Overall, 175 consecutive patients (64 ± 14 years, 141 men) treated with the BioFreedom (Biosensors Europe, Morges, Switzerland) polymer-free BES because of STEMI were included in this study. The primary endpoint was the rate of major adverse cardiac events (MACE), a composite of cardiac death, recurrent myocardial infarction, and ischemia-driven target vessel revascularization at 1 year follow-up. A subgroup of patients underwent 6-month angiographic follow-up. Dual antiplatelet therapy was prescribed for 12 months after STEMI.. At 1 year, the cumulative rate of MACE was 4.6%. One patient (0.6%) had an arrhythmic cardiac death and five (2.9%) had ischemia-driven target vessel revascularization, although only three (1.7%) had target lesion revascularization. Two (1.1%) patients had acute stent thrombosis yielding nonfatal myocardial infarction. In 70 patients (63 ± 14 years, 61 men), quantitative coronary angiography at 6-month follow-up revealed diameter stenosis of 24.1 ± 13.7% and minimal lumen diameter of 2.29 ± 0.56 mm, yielding a late lumen loss of 0.13 ± 0.14 mm.. In real-world setting, implantation of a new-generation polymer-free BES during STEMI is associated with favorable clinical and angiographic results, pointing toward the overall efficacy and safety of the device in complex clinical scenarios. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Hospitals, Public; Hospitals, Urban; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Recurrence; Registries; Risk Factors; Rome; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2018 |
Twelve-month outcomes of patients unsuitable for prolonged DAPT presenting with an acute coronary syndrome and treated with polymer-free biolimus A9 drug-coated stents.
Prolonged dual anti-platelet therapy (DAPT) is undesirable in certain patients. The biolimus-A9 drug-coated stent (BA9-DCS) has a rapid drug-elution profile allowing shortened DAPT.. The demographics, procedural data, and clinical outcomes for 505 patients presenting with an ACS to three UK centres and treated with a BA9-DCS stent (PCI-DCS) were collected, and compared to a consecutive ACS cohort of unselected patients treated in the same period with drug-eluting stents (PCI-DES).. PCI-DCS patients were older, more often female with hypertension, chronic kidney disease, severe LV dysfunction, and peripheral vascular disease more frequent than the PCI-DES cohort. PCI-DCS patients had a much higher Mehran bleed risk score (21.5 ± 7.7 vs. 15.9 ± 7.7, P < 0.0001). Baseline disease burden was greater in the PCI-DCS cohort with more left main and three vessel disease. During PCI, more stents (1.91 ± 1.1 vs. 1.57 ± 0.94, P < 0.0001), total stent length (38.2 ± 20.8 vs. 31.4 ± 20.3, P < 0.0001) and longer stents (38.2 ± 20.8 vs. 31.4 ± 20.3 mm, P < 0.0001) were used in the PCI-DCS cohort with rotational atherectomy also used more frequently. Physician-recommended DAPT duration was 2.9 ± 3.9 months for PCI-DCS patients and 11.3 ± 2.4 months for PCI-DES patients (P < 0.0001). At 12-month follow-up, definite stent thrombosis (0.6% vs. 1.1%) and TLR (3.2% vs. 2.7%) rates were similar between the two groups. After adjustment for baseline differences, there were no statistically significant differences in death and combined MACE rates at 12 months.. The outcomes of patients treated with polymer-free BA9 drug-coated stent who present with an ACS and who were deemed unsuitable for prolonged DAPT are encouraging. Further studies are warranted. Topics: Acute Coronary Syndrome; Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Drug Administration Schedule; Drug Therapy, Combination; Drug-Eluting Stents; Female; Hemorrhage; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Preliminary Data; Prosthesis Design; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Time Factors; Treatment Outcome; United Kingdom | 2018 |
Mid-term outcome of biolimus-eluting stents with biodegradable polymer: results from a multinational prospective 'all-comers' registry.
The Nobori biolimus-eluting stent (BES) is a biodegradable polymer drug-eluting stent (DES). Several studies have shown its noninferiority in comparison with durable polymer DES.. We sought to investigate the efficacy and the safety of Nobori BES in an all-comer population undergoing a percutaneous coronary intervention.. A total of 12 912 patients with 19 947 coronary lesions, undergoing percutaneous coronary intervention with Nobori BES implantation at 200 centres around the world between August 2010 and December 2015, were included in this prospective registry. Patients were stratified into four groups according to the total stent length, with cutoffs at 18, 24 and 28 mm. The primary endpoint was the occurrence of major adverse cardiac events defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularization at 1 year.. At 1 year, the major adverse cardiac events rate was the highest (4.6%) in the fourth quartile of stent length (>28 mm), whereas the overall rate of the primary endpoint in the all cohort was 3.5%. Both target lesion revascularization and target vessel revascularization rates were significantly higher in patients with longer stent length was implanted (all P<0.05). The incidence of definite and probable stent thrombosis at 1 year was 0.5% in all cohort and similar across the four groups (varying from 0.4 to 0.7%, all P=NS).. Our data confirmed the efficacy and the safety of the Nobori BES in routine clinical practice. Longer stent length is associated with a higher risk of adverse cardiac events, and yet, this risk is comparable with that of other DES. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prospective Studies; Prosthesis Design; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Abluminal-Coated Drug-Eluting Bifurcation-Dedicated Stent for the Treatment of Tibioperoneal Bifurcation.
Endovascular treatment of below-the-knee region disease is often challenging because of the involvement of arterial bifurcations. Several cases have been reported on the use of coronary stents for the treatment of these patients, but limited evidence is available on the use of dedicated coronary bifurcation devices. We here report the endovascular treatment of a symptomatic bifurcation lesion in below-the-knee region, using a self-expanding Biolimus A9-eluting stent in combination with a "conventional" coronary drug-eluting stent. Topics: Angiography; Angioplasty, Balloon; Cardiovascular Agents; Drug-Eluting Stents; Humans; Leg; Male; Middle Aged; Peripheral Arterial Disease; Prosthesis Design; Radiography, Interventional; Sirolimus; Tibial Arteries; Treatment Outcome | 2017 |
Comparative Case-Control analysis of a dedicated self-expanding Biolimus A9-eluting Bifurcation stent versus provisional or mandatory side branch intervention strategies in the treatment of coronary bifurcation lesions.
In a number of coronary bifurcation lesions, both the main vessel and the side branch (SB) need stent coverage.. To analyze the procedural performance and the impact on radiation times (RT) and contrast medium consumption (CMC) of the Axxess™ stent system (Biosensors, Switzerland) treating de novo bifurcation lesions (DBL).. One hundred and ten consecutive prospectively enrolled cases (Axxess Group) and 110 age, sex, and lesion location matched controls undergoing mandatory (Group A, n = 56) or provisional (Group B, n = 54) SB intervention were analyzed.. Although more pre-dilatation was performed in the Axxess Group (92.7% vs. 46.4% [Group A] vs. 24.1% [Group B]), and more stents were used (2.4 vs. 1.2 vs. 1.05), RT and CMC were significantly lower in the Axxess Group [7.9 min/129 ml vs. 14.2 min/209 ml vs. 7.8 min/152 ml; P < 0.001]. Final Thrombolysis In Myocardial Infarction three flow in both branches was significantly more frequent in the Axxess Group (98.2% vs. 94.6% vs. 88.9%; P = 0.02), and post-interventional troponin T elevations were the lowest in the Axxess Group. Eighty one percent of the Axxess-stents could be implanted without technical difficulties. Difficult implantations procedures were mainly related to coronary anatomy. There was no safety concerns (cardiac death, stent-thrombosis) compared to controls. Cumulative 6-months MACE rates were 11% versus 23% versus 25%. TLR rates at 6-months were 5%, 18%, and 15%, respectively.. Axxess bifurcation stent system procedures were associated with significantly less RT and CMC compared to conventional DBL therapy strategies. Difficult coronary anatomy may hinder successful implantation and a learning curve has to be considered. © 2016 Wiley Periodicals, Inc. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Case-Control Studies; Contrast Media; Coronary Angiography; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Female; Germany; Humans; Male; Middle Aged; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Radiation Dosage; Radiation Exposure; Radiography, Interventional; Registries; Risk Factors; Sirolimus; ST Elevation Myocardial Infarction; Time Factors; Treatment Outcome | 2017 |
Comparison of Biolimus Versus Everolimus for Drug-Eluting Stents in the Percutaneous Treatment of Infra-Inguinal Arterial Disease.
Drug-eluting stents (DES) are now considered the most promising device to treat peripheral artery disease (PAD) and minimize restenosis. There is uncertainty however on the best antirestenotic drug for such devices. In particular, biolimus (i.e. umirolimus) and everolimus are two of the most promising agents, given the extensive data in support of their coronary safety and efficacy, but their comparative effectiveness for peripheral interventions is not established.. Building upon our extensive experience in the percutaneous treatment of infra-inguinal artery disease with DES, we compared the acute and longterm outlook of patients treated with biolimus-eluting stents (BES) and everolimus-eluting stents (EES). We collected baseline, procedural and outcome details on all patients undergoing infra-inguinal BES or EES implantation. The endpoints of interest were death, amputation, revascularization, their composite, and change in Fontaine class. A total of 80 patients were included (20 treated with BES and 60 with EES). Most features were similar in the two groups, despite longer lesions in the EES group. Unadjusted analysis showed similar results irrespective of the drug used, with composite endpoint occurring, respectively, in 4 (20.0%) and 10 (16.7%) (p=0.741).. However, analysis with inverse probability of treatment weighting showed significant differences in the risk of revascularization (hazard ratio of BES vs EES=9.55 [95% confidence interval 2.16-42.23], p=0.003) and composite endpoint (hazard ratio=5.11 [1.33-19.62], p=0.018). In conclusion, EES appear superior to BES for endovascular therapy of infrainguinal artery disease. Dedicated randomized trials are required to definitely confirm or disprove these findings. Topics: Aged; Aged, 80 and over; Amputation, Surgical; Cardiovascular Agents; Comparative Effectiveness Research; Drug-Eluting Stents; Endovascular Procedures; Everolimus; Female; Humans; Limb Salvage; Male; Middle Aged; Peripheral Arterial Disease; Prosthesis Design; Retrospective Studies; Sirolimus; Time Factors; Treatment Outcome | 2017 |
Optical coherence tomography-based assessment of bifurcation stenting using the Axxessª Biolimus A9ª-eluting stent system.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Humans; Predictive Value of Tests; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Differences of side branch jailing between left main-left anterior descending artery stenting and left main-left circumflex artery stenting with Nobori biolimus-eluting stent.
The aim of this study is to indicate differences of side branch jailing between the left main (LM)-left anterior descending artery (LAD) stenting and the LM-left circumflex artery (LCx) stenting. Thirty-one patients who underwent single-stenting using a two-link ten-crowns biolimus-eluting stent (Japanese design of BES, J-BES) and subsequent kissing balloon dilation (KBD) on an LM bifurcation with optical coherence tomography (OCT) were divided into two groups according to the stented vessel. Bifurcation angles were measured by three-dimensional (3D) quantitative coronary analysis. The jailing pattern on a side branch ostium was evaluated by stent-enhanced 3D-OCT. Incomplete stent apposition (ISA) after KBD was compared between the stented vessels. The to-be-stented angle of the LM-LCx stenting (n = 11) was significantly steeper than that of the LM-LAD stenting (n = 20) (132.6° ± 16.9° vs. 150.7° ± 10.6°, p < 0.01). The incidence of the free carina type, which has no stent links bridging from a carina, in the LM-LCx stenting was significantly higher than that in the LM-LAD stenting (90.9 vs. 45.0 %, p = 0.02). The percentage of ISA at the bifurcation segment in the LM-LCx stenting was significantly smaller than that in the LM-LAD stenting (4.4 ± 8.2 vs. 12.7 ± 9.2 %, p = 0.0003). This study showed, by higher incidence of the favorable configuration, that the LM-LCx stenting achieved a smaller percentage of ISA than the LM-LAD stenting. These insights may help guide LM bifurcation stenting with J-BES. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Imaging, Three-Dimensional; Japan; Male; Middle Aged; Prosthesis Design; Radiographic Image Interpretation, Computer-Assisted; Retrospective Studies; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Unfavorable bioresorbable vascular scaffold resorption, a cause of restenosis?
We report a case of bioresorbable vascular scaffold restenosis which could be caused by abnormal resorption 17months after implantation. Topics: Absorbable Implants; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Male; Middle Aged; Non-ST Elevated Myocardial Infarction; Prosthesis Design; Retreatment; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy.
The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Occlusion; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Hypolipidemic Agents; Male; Percutaneous Coronary Intervention; Plaque, Atherosclerotic; Retreatment; Sirolimus; Stents; Time Factors; Tomography, Optical Coherence; Treatment Outcome | 2016 |
One-year outcome from an all-comers population of patients with ST-segment elevation myocardial infarction treated with biolimus-eluting stent with biodegradable polymer.
To evaluate the performance of biolimus-eluting stent (BES) in patients with ST-elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI) in a real world clinical scenario.. Randomized studies suggest that the BES with biodegradable polymer is more effective and safe than early generation coronary stents in patients with STEMI.. We included all consecutive STEMI patients undergoing PCI in this prospective, multicenter registry. The primary endpoint of the study was the rate of major adverse cardiac events (MACE), a composite of cardiac death, recurrent myocardial infarction and ischemia-driven target vessel revascularization at 1-year follow-up.. Between June and December 2012 we enrolled 311 STEMI patients. The primary endpoint occurred in 3.2% (95% confidence interval: 1.6-5.8) of patients: cardiac death, re-infarction, and ischemia-driven TVR occurred in 2.3%, 1.3%, and 0.6% of patients, respectively. One-year MACE-free survival was 96.8% ± 1.0%.. In a real-world cohort of STEMI patients undergoing PCI, the use of BES is associated with good 1-year clinical outcome. These results confirm and expand previous findings showing the efficacy and safety of BES in the setting of randomized trials. Topics: Aged; Cardiovascular Agents; Disease-Free Survival; Drug-Eluting Stents; Female; Humans; Italy; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Prospective Studies; Prosthesis Design; Recurrence; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Outcomes following implantation of the Biolimus A9-eluting BioMatrix coronary stent: Primary analysis of the e-BioMatrix registry.
To assess the safety and efficacy of Biolimus A9-eluting stents (BES, BioMatrix™ and BioMatrix Flex™) in routine clinical practice.. The LEADERS randomized trial has documented equivalent efficacy and superior safety of the BES when compared to a first generation Sirolimus-eluting Cypher(TM) stent.. 5,472 patients from 57 centers, treated with BES, were enrolled in an international multicenter registry and followed clinically up to 2 years.. Mean patient age was 63.2 ± 11 years, 24% of patients had diabetes, and 49.8% presented with an acute coronary syndrome. 99.3% of patients were discharged on dual antiplatelet therapy (DAPT), 83.3% remained on DAPT at 1 year and 30.6% at 2 years. The incidence of the composite primary end point [major adverse cardiac events (MACE) at 12 months] was 4.5% [cardiac death 0.9%, myocardial infarction 1.7%, clinically indicated target vessel revascularization (ci-TVR) 2.8%]. MACE incidence was 6.8% at 24 months (cardiac death 1.5%, myocardial infarction 2.4%, ci-TVR 4.3%). At 12 months, 32 patients (0.6%) had suffered at least one definite or probable stent thrombosis (ST), and 91 patients (1.7%) a major bleed (MB). Nine patients with ST (27.3%) and 7 patients with a MB (7.7%) died during the first year after the index procedure. Between 12 and 24 months after implantation, there were 18 (0.4%) additional MB and 8 (0.2%) additional ST.. This large international cohort documents a low 12 and 24 months MACE incidence and a very low ST incidence in an unselected patient population undergoing BES implantation. The results are in keeping with those of the randomized controlled LEADERS trial. Even though ST with this stent was a rare event, it was still associated with significant mortality. MB remains a problem, and warrants improved tailoring of DAPT in recipients of drug eluting stents. Topics: Aged; Cardiovascular Agents; Comorbidity; Coronary Artery Disease; Coronary Thrombosis; Drug Therapy, Combination; Drug-Eluting Stents; Female; Humans; Incidence; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Platelet Aggregation Inhibitors; Proportional Hazards Models; Registries; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2015 |
Long-term safety and feasibility of three-vessel multimodality intravascular imaging in patients with ST-elevation myocardial infarction: the IBIS-4 (integrated biomarker and imaging study) substudy.
We assessed the feasibility and the procedural and long-term safety of intracoronary (i.c) imaging for documentary purposes with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in patients with acute ST-elevation myocardial infarction (STEMI) undergoing primary PCI in the setting of IBIS-4 study. IBIS4 (NCT00962416) is a prospective cohort study conducted at five European centers including 103 STEMI patients who underwent serial three-vessel coronary imaging during primary PCI and at 13 months. The feasibility parameter was successful imaging, defined as the number of pullbacks suitable for analysis. Safety parameters included the frequency of peri-procedural complications, and major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and any clinically-indicated revascularization at 2 years. Clinical outcomes were compared with the results from a cohort of 485 STEMI patients undergoing primary PCI without additional imaging. Imaging of the infarct-related artery at baseline (and follow-up) was successful in 92.2% (96.6%) of patients using OCT and in 93.2% (95.5%) using IVUS. Imaging of the non-infarct-related vessels was successful in 88.7% (95.6%) using OCT and in 90.5% (93.3%) using IVUS. Periprocedural complications occurred <2.0% of OCT and none during IVUS. There were no differences throughout 2 years between the imaging and control group in terms of MACE (16.7 vs. 13.3%, adjusted HR1.40, 95% CI 0.77-2.52, p = 0.27). Multi-modality three-vessel i.c. imaging in STEMI patients undergoing primary PCI is consistent a high degree of success and can be performed safely without impact on cardiovascular events at long-term follow-up. Topics: Aged; Cardiovascular Agents; Coronary Vessels; Drug-Eluting Stents; Europe; Feasibility Studies; Female; Humans; Male; Metals; Middle Aged; Multimodal Imaging; Myocardial Infarction; Percutaneous Coronary Intervention; Predictive Value of Tests; Prospective Studies; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2015 |
Instant Stent-Accentuated 3-Dimensional Optical Coherence Tomography of Struts Pulled Up by Pulling Stuck Wire and Folded by Kissing Balloon Dilation.
Topics: Angioplasty, Balloon, Coronary; Cardiac Catheters; Cardiovascular Agents; Coronary Angiography; Coronary Stenosis; Coronary Vessels; Drug-Eluting Stents; Humans; Imaging, Three-Dimensional; Male; Middle Aged; Predictive Value of Tests; Prosthesis Design; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2015 |
Drug-Eluting Stent Implantation on Calcified Nodule: Ex Vivo Intravascular Images and Histopathology.
Topics: Aged; Angioscopy; Autopsy; Biopsy; Cardiovascular Agents; Coronary Artery Disease; Coronary Vessels; Drug-Eluting Stents; Fatal Outcome; Female; Humans; Percutaneous Coronary Intervention; Sirolimus; Treatment Outcome; Ultrasonography, Interventional; Vascular Calcification | 2015 |
Successful retrograde percutaneous coronary intervention to a right coronary ostium agenesis via an extremely tortuous epicardial collateral.
Topics: Adult; Cardiovascular Agents; Collateral Circulation; Coronary Angiography; Coronary Circulation; Coronary Vessel Anomalies; Coronary Vessels; Drug-Eluting Stents; Humans; Male; Percutaneous Coronary Intervention; Sirolimus; Treatment Outcome | 2015 |
Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations.
To compare biodegradable polymer biolimus-eluting (BES) with abluminal drug elution and durable polymer everolimus-eluting (EES) stents in the treatment of bifurcation lesions.. The persistence of a polymer in drug-eluting stents (DES) following drug elution has been viewed as a possible culprit for restenosis. DES with biodegradable polymer may thus be associated with improved clinical outcomes, especially in high-risk lesions such as those at bifurcation sites.. We performed a retrospective study of consecutive de novo bifurcation lesions treated with EES between October 2006 and October 2011 and BES between February 2008 and March 2012. Study endpoints included major adverse cardiac events (MACE) defined as all-cause death, myocardial infarction (MI), including peri-procedural MI, and target vessel revascularization (TVR) as well as target lesion revascularization (TLR) separately.. We analyzed 236 bifurcation lesions treated with either BES (79 lesions in 69 patients) or EES (157 lesions in 154 patients). Patient and procedural characteristics were broadly similar between the two groups. Estimated MACE and TVR rates at 2-year follow-up were similar between the BES and EES groups (MACE = 13.6 ± 4.6% vs. 14.6 ± 3.2% (P = 0.871); TVR = 6.9 ± 3.5% vs. 8.0 ± 2.7% (P = 0.889). No significant differences were noted between the two groups following propensity-score matched analysis. There was no probable or definite stent thrombosis.. BES use in the treatment of bifurcation lesions appears to be associated with good clinical outcomes, comparable to those seen with EES, at long-term follow-up. These results are hypothesis-generating and need to be validated with larger studies. Topics: Absorbable Implants; Aged; Cardiovascular Agents; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Percutaneous Coronary Intervention; Polymers; Prosthesis Design; Retrospective Studies; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2014 |
Incidence and clinical impact of stent fracture after the Nobori biolimus-eluting stent implantation.
Stent fracture (SF) after drug-eluting stent implantation has become an important concern. The aim of this study was to assess the incidence, predictors, and clinical impact of SF after biolimus-eluting stent.. A total of 1026 patients with 1407 lesions undergoing the Nobori biolimus-eluting stent implantation and follow-up angiography within 9 months after index procedure were analyzed. SF was defined as complete or partial separation of the stent, as assessed by using plain fluoroscopy, intravascular ultrasound, or optical coherence tomography during the follow-up. We assessed the rate of SF and the cumulative incidence of clinically driven target lesion revascularization and definite stent thrombosis within 9 months. SF was observed in 58 (4.1%) of 1407 lesions and 57 (5.5%) of 1026 patients. Lesions with hinge motion (OR 8.90, 95% CI 3.84 to 20.6, P<0.001), tortuosity (OR 4.16, 95% CI 1.75 to 9.88, P=0.001), and overlapping stents (OR 2.41, 95% CI 0.95 to 6.10, P=0.06) were predictors of SF. Cumulative incidence of clinically driven target lesion revascularization within 9 months was numerically higher in the SF group than that in the non-SF group (12.0% versus 1.0%). Cumulative incidence of definite stent thrombosis within 9 months tended to be higher in the SF group than that in the non-SF group (1.7% versus 0.5%).. SF after biolimus-eluting stent occurs in 4.1% of lesions and appears to be associated with clinically driven target lesion revascularization. Topics: Aged; Aged, 80 and over; Cardiovascular Agents; Chi-Square Distribution; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Thrombosis; Drug-Eluting Stents; Female; Humans; Incidence; Japan; Logistic Models; Male; Middle Aged; Multivariate Analysis; Odds Ratio; Percutaneous Coronary Intervention; Prosthesis Design; Prosthesis Failure; Risk Factors; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2014 |
Treatment of coronary bifurcations with third generation drug-eluting stent: making major headway or just baby steps?
Topics: Absorbable Implants; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Everolimus; Female; Humans; Male; Percutaneous Coronary Intervention; Polymers; Sirolimus | 2014 |
Intricacies in the analysis and interpretation of optical coherence tomography findings.
Topics: Cardiovascular Agents; Coronary Stenosis; Coronary Vessels; Female; Humans; Male; Percutaneous Coronary Intervention; Sirolimus; Tomography, Optical Coherence | 2014 |
Automated assessment and 3-dimensional visualization of the pattern of neointimal tissue maturity in vivo following drug-eluting stent implantation.
Topics: Algorithms; Angina, Unstable; Automation; Cardiovascular Agents; Coronary Vessels; Drug-Eluting Stents; Humans; Image Interpretation, Computer-Assisted; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Wound Healing | 2014 |
Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix DES by OCT. 20 patients undergoing BioMatrix DES (n = 15) or S-Stent BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix and S-Stent, respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix = 9 and S-Stent = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix group compared to 23 (4.0 %) in the S-Stent group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition. Topics: Aged; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Coronary Vessels; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Neointima; Percutaneous Coronary Intervention; Predictive Value of Tests; Prosthesis Design; Sirolimus; Time Factors; Tomography, Optical Coherence; Treatment Outcome; Ultrasonography, Interventional | 2013 |
Long-term comparison of everolimus-eluting and biolimus-eluting stents.
Second-generation everolimus-eluting stents (EES) are safer and more efficient than first-generation paclitaxel-eluting stents (PES). Third-generation biolimus-eluting stents (BES) have been found to be non-inferior to PES. To date, there is no available comparative study between EES and BES. We aimed to investigate the safety and efficacy of BES with biodegradable polymer compared to EES with durable polymer at a follow-up of two years in an unselected population of consecutively enrolled patients.. A group of 814 consecutive patients undergoing percutaneous coronary intervention (PCI) was enrolled between 2007 and 2010, of which 527 were treated with EES and 287 with BES implantation. Clinical outcome was compared in 200 pairs using propensity score matching. The primary endpoint was a composite of death, myocardial infarction (MI) and target vessel revascularisation (TVR) at two-year follow-up. Median follow-up was 22 months. The primary outcome occurred in 11.5% of EES and 10.5% of BES patients (HR 1.11, 95% CI: 0.61-2.00, p=0.74). At two years, there was no significant difference with regard to death (HR 0.49, 95% CI: 0.18-1.34, p=0.17), cardiac death (HR 0.14, 95% CI: 0.02-1.14, p=0.66) or MI (HR 6.10, 95% CI: 0.73-50.9, p=0.10). Stent thrombosis (ST) incidence was evenly distributed between EES (n=2) and BES (n=2) (p-value=1.0).. This first clinical study failed to demonstrate any significant difference regarding safety or efficacy between these two types and generations of drug-eluting stents (DES). Topics: Aged; Cardiovascular Agents; Chi-Square Distribution; Coronary Artery Disease; Coronary Thrombosis; Drug-Eluting Stents; Everolimus; Female; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Multivariate Analysis; Myocardial Infarction; Percutaneous Coronary Intervention; Propensity Score; Proportional Hazards Models; Prosthesis Design; Risk Factors; Sirolimus; Time Factors; Treatment Outcome | 2013 |
In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.
To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries.. Rabbits were fed with 1% cholesterol diet (n = 14) for 14 days, both iliac arteries were balloon denuded and radiated, and then rabbits were switched to 0.15% cholesterol diet. After 4 weeks, BF (n = 8), BMF (n = 8), and BMS (n = 8) were deployed in denuded and radiated areas. Four weeks later animals were euthanized, arterial segments were processed for morphometry.. The neointimal area in vessels implanted with BF stents was significantly less than that seen in vessels implanted with BMS (0.90 mm(2) ± 0.14 vs. 1.29 mm(2) ± 0.23, P <0.01). Percent fibrin and fibrin score were higher with BMF stents compared to BMS (P <0.03 and <0.04) and giant cell number was significantly higher with both BMF and BF stents (P < 0.01 for both). Percent endothelialization was significantly higher and % uncovered struts were lower with BMS compared to either BMF or BF stents (P < 0.05 for both).. This study demonstrates that compared to BMS, BF stents significantly decreased neointimal hyperplasia. Topics: Absorbable Implants; Angioplasty, Balloon; Animals; Atherosclerosis; Cardiovascular Agents; Constriction, Pathologic; Disease Models, Animal; Drug-Eluting Stents; Fibrin; Hypercholesterolemia; Hyperplasia; Iliac Artery; Inflammation; Male; Metals; Neointima; Plaque, Atherosclerotic; Polymers; Prosthesis Design; Rabbits; Sirolimus; Stents; Time Factors | 2012 |
Clinical performance of a drug-eluting stent with a biodegradable polymer in an unselected patient population: the NOBORI 2 study.
Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting.. A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5).. The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions. Topics: Absorbable Implants; Aged; Analysis of Variance; Angioplasty, Balloon, Coronary; Asia; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Europe; Female; Guideline Adherence; Humans; Kaplan-Meier Estimate; Male; Middle Aged; Myocardial Infarction; Polymers; Practice Guidelines as Topic; Product Labeling; Prospective Studies; Prosthesis Design; Registries; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2012 |
Delamination of abluminal polymer of biolimus-eluting stent.
Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Stenosis; Drug-Eluting Stents; Humans; Male; Microscopy, Electron, Scanning; Polymers; Prosthesis Design; Severity of Illness Index; Sirolimus; Treatment Outcome; Vascular Calcification | 2012 |
Nobori stent shows less vascular inflammation and early recovery of endothelial function compared with Cypher stent.
The current study sought to examine inflammation at the stented segments of Nobori (Terumo Corporation, Tokyo, Japan) and Cypher (Cordis, Miami, Florida) drug-eluting stents (DES), as well as free radical production and endothelial function of the adjacent nonstented segments in a pig coronary model.. Nobori is a novel DES, incorporating a biolimus A9-eluting biodegradable polymer coated only on the abluminal surface of the stent. These unique features may favorably affect inflammation and endothelial function, as compared to the currently marketed DES. Presently, pre-clinical data on direct comparison of the various generations of DES are not available.. A total of 18 DES were implanted in pig coronary arteries and subsequently explanted at 1 month. Stented segments were assessed by angiography and histology. Ex vivo vasomotor function and superoxide production in segments proximal and distal to the stent were determined. The vasoconstriction, endothelial-dependent relaxation, and endothelial-independent relaxation of proximal and distal nonstented segments were measured.. Histological evaluation revealed lower inflammatory response with Nobori than with Cypher DES. There is trend for lower angiographic percentage diameter stenosis in Nobori versus Cypher groups (p = 0.054). There was increased endothelium-dependent relaxation, decreased endothelin-1-mediated contraction, and less superoxide production in the vessel segments proximal and distal to Nobori versus Cypher stents.. Our data show significantly lower inflammatory response in the stented segments, and rapid recovery of endothelial function of peristent segments in the Nobori group compared with Cypher DES group at 1 month in porcine coronary artery model. Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Vessels; Dose-Response Relationship, Drug; Drug-Eluting Stents; Endothelium, Vascular; Inflammation; Japan; Models, Animal; Prosthesis Design; Recovery of Function; Sirolimus; Superoxides; Sus scrofa; Time Factors; Vasoconstriction; Vasoconstrictor Agents; Vasodilation; Vasodilator Agents | 2012 |
Vascular responses to a biodegradable polymer (polylactic acid) based biolimus A9-eluting stent in porcine models.
The time-dependent changes in endothelial and healing properties of coronary arteries implanted with a biodegradable polymer-based biolimus A9-eluting stent (BioPol-BES) have not been investigated. We evaluated the short-term and the long-term in vivo response of BioPol-BES, as compared to a permanent polymer-based sirolimus-eluting stent (PermPol-SES), and a bare metal stent (BMS).. Overlapping stents were placed in 33 swine (n=11 for BES, SES, and BMS, respectively) for two and four weeks and single stents in 30 miniature pigs (n=18 for BES, n=9 for SES, n=3 for BMS) for three, nine and 15-month evaluations. The vessel patency, arterial healing and endothelialisation were assessed by angiography, histopathology and scanning electron microscopy. At four weeks, the endothelialisation at overlapping stent regions was greater with BioPol-BES (87.8±3.7%) and BMSs (98.0±0.4%) than with PermPol-SES (66.4±3.2%). The inflammation score in vessels implanted with single BioPol-BES increased slightly from three to 15 months (0.00±0.00 to 0.28±0.14), while this increase was more pronounced with PermPol-SES (0.11±0.07 to 1.56±0.68). Compared to BMS moderate lymphocyte infiltration was seen with BioPol-BES, and marked granulomatous formation with PermPol-SES.. The level of endothelial coverage in BioPol-BES was comparable to BMS at four weeks, with no significant increase of inflammatory reaction up to 15 months. Topics: Angioplasty, Balloon; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Endothelial Cells; Granuloma; Inflammation; Lactic Acid; Lymphocytes; Metals; Microscopy, Electron, Scanning; Models, Animal; Polyesters; Polymers; Prosthesis Design; Sirolimus; Swine; Swine, Miniature; Time Factors; Ultrasonography; Vascular Patency; Wound Healing | 2012 |
Bioresorbable polymers: a temporary solution?
Topics: Cardiovascular Agents; Coronary Stenosis; Drug-Eluting Stents; Female; Humans; Male; Percutaneous Coronary Intervention; Sirolimus | 2012 |
Comparison of pharmacokinetics of the limus-eluting stents in Japanese patients.
The aim of this study was to compare the pharmacokinetics of the four limus-eluting stents used in Japanese patients.. There are presently no reports comparing human pharmacokinetics among drug-eluting stents (DESs).. We retrospectively analyzed data from pharmacokinetic studies of patients implanted with an 18-mm DES: Cypher stent (sirolimus, n = 10), Endeavor stent (zotarolimus, n = 7), Xience V stent (everolimus, n = 6), and Nobori stent (biolimus A9, n = 10), in multicenter trials of Japan. Total drug doses of the Cypher stent, Endeavor stent, Xience V stent, and Nobori stent were 150, 180, 88, and 293 μg, respectively. Drug concentrations were measured in serial whole blood samples after implantation and the pharmacokinetics were analyzed.. Mean peak drug levels were 0.86 ng mL(-1) for Cypher, 1.80 ng mL(-1) for Endeavor, 0.50 ng mL(-1) for Xience V, and 0.09 ng mL(-1) for Nobori. After adjustment for the loaded dose, mean peak drug levels of the Cypher and Xience V stents were similar (0.0057 ng mL(-1) μg(-1) each) while the Endeavor (0.0100 ng mL(-1) μg(-1)) was higher, and the Nobori (0.0003 ng mL(-1) μg(-1)) was lower, compared with the Cypher and Xience V stents. The other pharmacokinetic parameters of four DESs differed according to characteristics of the coated drug. The systemic exposure of biolimus A9 was much lower than that of the other DESs studied.. In Japanese patients, systemic exposure was low, regardless of the type of limus drug eluted from the stents; but specific pharmacokinetic activities were varied according to the drug characteristics, concentration, and DES design. Topics: Aged; Analysis of Variance; Asian People; Cardiovascular Agents; Clinical Trials as Topic; Drug-Eluting Stents; Everolimus; Female; Humans; Japan; Linear Models; Male; Middle Aged; Models, Biological; Multicenter Studies as Topic; Prosthesis Design; Retrospective Studies; Sirolimus | 2011 |
Long-term complication after LM bifurcation treatment.
Two months after left anterior descending (LAD) artery and left circumflex (LCx) artery bare metal stent implantation, a proliferative subocclusive in-stent restenosis in LCx coronary with severe LM coronary (LM) involvement developed. The present clinical case describes a simplified strategy for unprotected LM percutaneous coronary intervention using two bioabsorbable biolimus-eluting stents without involvement of the LAD coronary using an "L" technique. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Male; Metals; Middle Aged; Prosthesis Design; Sirolimus; Stents; Time Factors; Treatment Outcome | 2010 |
Percutaneous UPLM revascularisation: the time has come.
Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Metals; Prosthesis Design; Sirolimus; Stents; Time Factors; Treatment Outcome | 2010 |
The AXXESS™ self-expanding biolimus A9™ eluting stent system for coronary bifurcation lesions.
Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Drug-Eluting Stents; Humans; Materials Testing; Patient Selection; Prosthesis Design; Sirolimus; Treatment Outcome | 2010 |
Treating the left main bifurcation lesion: the "three stent solution".
Topics: Alloys; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Restenosis; Coronary Stenosis; Drug-Eluting Stents; Humans; Prosthesis Design; Sirolimus; Stents; Treatment Outcome; Ultrasonography, Interventional | 2009 |
In vivo evaluation of a biolimus eluting nickel titanium self expanding stent with overlapping balloon expandable drug eluting and bare metal stents in a porcine coronary model.
Long lesions and complex vessel anatomy frequently require the use of overlapping stents to treat a lesion. The purpose of this study was to evaluate the long-term effects of overlapping the Axxess Biolimus A9 eluting stent (BES) with two of the most commonly used, commercially available drug eluting stents. These stents were compared to BxVelocity bare metal (BMS) stents in a porcine coronary stent-injury model.. Nineteen juvenile farm swine, 25-35 kg in weight, 3-6 months in age were utilised. Each animal received an Axxess stent to their coronary artery as permitted by the individual animal's anatomy. A second stent, either a Cypher, sirolimus eluting stent (SES) or, a Taxus, paclitaxel eluting stent (PES), or a BxVelocity bare metal stent (BMS) were implanted in an overlapped fashion. The animals were then followed for either 28 or 180 days as specified by a randomisation scheme. At the end of each follow-up period, they were euthenised, and the vessels containing the overlapping stents were harvested, processed into histological sections, and analysed. Compared to bare metal stents, overlapped segments using DES exhibited delayed vascular healing compared to both the proximal and distal non-overlap sites at each of the follow-up time point. Overall, in the non-overlap stent segments, SES induced significantly more inflammation and neointimal hyperplasia compared to PES and BMS.. In this study of BMS and two different types of DES overlapped with the Axxess Biolimus A9 eluting stent, we found that while there was a delay in the degree of vascular healing with DES compared to BMS, the specific type of DES that was overlapped with BES did not affect the behaviour of the overlap zone in terms of most of the histomorphometric measures at 28 or 180 days. This was true whether the stent was drug eluting or bare metal. More inflammation with delayed healing was seen in the SES compared to PES and BMS. Topics: Angioplasty, Balloon, Coronary; Animals; Cardiovascular Agents; Cell Proliferation; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Hyperplasia; Inflammation; Models, Animal; Nickel; Paclitaxel; Platelet Aggregation Inhibitors; Prosthesis Design; Sirolimus; Stents; Swine; Time Factors; Titanium; Wound Healing | 2009 |
Reproducibility of quantitative optical coherence tomography for stent analysis.
To assess the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with optical coherence tomography (OCT).. Ten drug-eluting stents (244 frames, 1712 struts) imaged with OCT nine months after implantation were analysed by two independent analysts. One of the analysts repeated the analysis of five stents (120 frames, 795 struts) one week later. Offline analysis was performed with the proprietary LightLab Imaging software. The number of struts was counted and lumen and stent area contours were traced. Tissue coverage thickness was measured at 360 degrees of vessel circumference and in front of every individual strut. The number of malapposed struts was determined. There was good agreement for strut number count (Kendall's Tau-b 0.90 for inter- and 0.94 for intra- observer variability). The relative difference for lumen area, stent area and tissue coverage measurements was around 1%. There was complete inter- and intra- observer agreement for malapposed struts classification (4 out of 1708 struts, Kappa=1).. In a Corelab setting, the inter- and intra- observer reproducibility for strut count, strut apposition and strut tissue coverage measurements with OCT is excellent. This emphasises the value of OCT as a tool for the clinical long-term assessment of stents. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Artery Disease; Drug-Eluting Stents; Humans; Image Interpretation, Computer-Assisted; Observer Variation; Predictive Value of Tests; Prosthesis Design; Reproducibility of Results; Sirolimus; Tomography, Optical Coherence; Treatment Outcome | 2009 |
Long-term outcome after the V stenting technique in de novo bifurcation lesions using drug-eluting stents.
To report long-term outcome data on the V technique using drug-eluting stents.. From April 2002 to December 2006, 31 consecutive patients were successfully treated with V stenting of a de novo bifurcation lesion. The technique involves the deployment of two stents in the two branches of a bifurcation, the proximal edges of the stents just touching one another. Patients exclusively received either sirolimus- (10), paclitaxel- (20) or biolimus-eluting (one) stents. On average, 1.5 +/- 0.8 stents with a total length of 26.6 +/- 17.2 mm and 1.1 +/- 0.4 stents with a total length of 18.3 +/- 7.6 mm were deployed in the distal main vessel and side branch respectively. Mean duration of follow-up was 853 +/- 553 days. Within 30 days, three patients died; two other patients had definite stent thrombosis involving the V stents, both requiring re-PCI. Beyond 30 days and within one year, there was one death and three cases of target vessel revascularisation, including one target lesion revascularisation. There were a further three deaths (one cardiac) beyond one year. Eleven patients (35.5%) had angiographic follow-up, exhibiting a binary restenosis rate of 9.1% at 203 +/- 33 days.. In this real-world cohort, late clinical events stand in accord with studies on competitive techniques, but early outcome was less encouraging, probably due to the baseline risks. Topics: Aged; Angioplasty, Balloon, Coronary; Cardiovascular Agents; Coronary Angiography; Coronary Artery Disease; Coronary Restenosis; Drug-Eluting Stents; Female; Humans; Male; Middle Aged; Netherlands; Paclitaxel; Prosthesis Design; Registries; Retrospective Studies; Risk Assessment; Risk Factors; Sirolimus; Thrombosis; Time Factors; Treatment Outcome | 2009 |
Interference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses.
There is evidence that endothelial coverage of drug-eluting stents might be delayed or absent, a risk factor for late thrombotic events. We studied the effects of different drug-polymer-device iterations on endothelium-dependent coronary vasomotion. Systemic markers of endothelial inflammation were correlated with coronary vasomotor changes.. Patients with paclitaxel-eluting stents (n=11), sirolimus-eluting stents (n=21), biolimus A9-eluting stents (n=28), zotarolimus-eluting stents (n=10), and bare-metal stents (n=13) were studied 10, 9, 9, 9, and 12 months after implantation, respectively. Endothelium-dependent coronary vasomotion was tested proximally and distally to the stent and at a reference vessel segment during atrial pacing at increasing heart rates by quantitative coronary angiography. Indexes of platelet-monocyte binding and other biomarkers were studied in a subgroup of 19 patients. The baseline characteristics and hemodynamics of the patients in the different stent groups were comparable. Significant differences were observed across the 5 stent groups, concerning the vasomotion of segments proximal (P=0.006) and distal (P=0.003) to the stent. Normal vasomotion (vasodilatation) was maintained in the biolimus A9-eluting stent, zotarolimus-eluting stent, and bare-metal stent groups, whereas vasoconstriction was observed in the sirolimus-eluting stent and paclitaxel-eluting stent groups. Platelet-monocyte binding in whole blood showed a significant inverse correlation with vasomotion in reference but not in segments adjacent to the stent (r=-0.57; P=0.01).. Paclitaxel-eluting stents and sirolimus-eluting stents seem to cause endothelial dysfunction of the implanted vessel, whereas biolimus A9-eluting stents and zotarolimus-eluting stents behave more closely to bare-metal stents, with preserved endothelial vasomotor response. Coronary vasoconstriction was not associated with detectable systemic endothelial activation. Topics: Blood Platelets; Cardiovascular Agents; Cell Aggregation; Coronary Angiography; Coronary Vessels; Drug-Eluting Stents; Endothelium, Vascular; Female; Humans; Male; Middle Aged; Monocytes; P-Selectin; Paclitaxel; Sirolimus; Vasoconstriction; Vasodilation | 2008 |
Bifurcation stenting with a dedicated biolimus-eluting stent: X-ray visual enhancement of the final angiographic result with "StentBoost Subtract".
A 51 year-old man underwent percutaneous coronary intervention of a significant "true" bifurcation lesion involving the proximal left anterior descendens (LAD) artery and an important first diagonal branch with a dedicated bifurcation stent, which is a conical self-expandable biolimus-eluting stent with a "flared" distal part allowing for optimal scaffolding of the carina of the bifurcation, and two additional sirolimus-eluting stents, deployed with the V-stenting technique, one in the LAD and one in the diagonal branch, in overlap with the distal part of the "flared" biolimus-eluting stent. An X-ray enhancing visualization technique, "StentBoost Subtract," was used to obtain an improved visualization of the stent in relation to the corresponding vessel lumen and revealed good expansion of all the stents and good apposition to the vessel wall. Topics: Angioplasty, Balloon, Coronary; Cardiovascular Agents; Cineangiography; Contrast Media; Coronary Angiography; Coronary Artery Disease; Humans; Male; Middle Aged; Prosthesis Design; Radiographic Image Interpretation, Computer-Assisted; Radiography, Interventional; Severity of Illness Index; Sirolimus; Stents | 2007 |