captax and 2-5-dihydroxybenzoic-acid

captax has been researched along with 2-5-dihydroxybenzoic-acid* in 2 studies

Other Studies

2 other study(ies) available for captax and 2-5-dihydroxybenzoic-acid

ArticleYear
Analysis of
    Journal of the American Society for Mass Spectrometry, 2021, Apr-07, Volume: 32, Issue:4

    Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) can determine the chemical identity and spatial distribution of several molecules in a single analysis, conserving its natural histology. However, there are no specific studies on the spatial distribution of alkaloids in

    Topics: Alkaloids; Benzothiazoles; Coca; Coumaric Acids; Cyclotrons; Gentisates; Plant Leaves; Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization; Spectroscopy, Fourier Transform Infrared

2021
Significant sensitivity improvements by matrix optimization: a MALDI-TOF mass spectrometric study of lipids from hen egg yolk.
    Chemistry and physics of lipids, 2010, Volume: 163, Issue:6

    Due to its sensitivity, the tolerance of impurities and the simplicity of performance, matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is increasingly used to analyze lipids from biological sources. Although its detailed role is not understood so far, the applied matrix has a pronounced effect on the achievable spectrum quality and particularly how sensitive the individual lipid classes are detectable. Different matrix compounds were recently established in the lipid field including 2,5-dihydroxybenzoic acid (DHB), 9-aminoacridine (9-AA), para-nitroaniline (PNA), 2-mercaptobenzothiazole (MBT), and 2-(2-aminoethylamino)-5-nitropyridine (AAN). It is the aim of this paper to compare the properties of these matrices with the newly synthesized matrix, alpha-cyano-2,4-difluorocinnamic acid (Di-FCCA). An organic extract from hen egg yolk was used as a simple and easily available test system. It will be shown that Di-FCCA is the matrix of choice to detect lipids in the positive-ion mode due to an achievable sensitivity gain of more than one order of magnitude compared to alternative matrices. In contrast, Di-FCCA is not suitable for negative-ion detection of phospholipids. Here, 9-AA is unequivocally the matrix of choice.

    Topics: Aminacrine; Aniline Compounds; Animals; Benzothiazoles; Chickens; Cinnamates; Egg Yolk; Gentisates; Lipids; Pyridines; Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization

2010