buprenorphine and benzoylecgonine

buprenorphine has been researched along with benzoylecgonine* in 3 studies

Other Studies

3 other study(ies) available for buprenorphine and benzoylecgonine

ArticleYear
Evaluation of an Automated Reader and Color Interpretation-Based Immunoassays for Multiplexed Drug-of-Abuse Testing in Urine.
    Journal of analytical toxicology, 2017, Jun-01, Volume: 41, Issue:5

    On-site drugs of abuse testing devices have undergone continuous improvement. We evaluated three devices with different designs: an automated reader, the Multi-Drug Screen Test Device with DxLINK (DxLINK; Innovacon, Alere, San Diego, USA) and two colorimetric immunoassays, the One Step Multi-Line Screen Panel with Integrated E-Z Split Key Cup II (E-Z Cup; Innovacon, Alere) and the One Step Multi-Drug Screen Panel card (Multi4 card; Alere, Abon Biopharm, Hangzhou, China). Eleven drugs [amphetamine, secobarbital, oxazepam, buprenorphine, benzoylecgonine, methylenedioxymethamphetamine (MDMA), 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC), methamphetamine, methadone, morphine and nortriptyline] were tested using the DxLINK and E-Z Cup. Four drugs (benzoylecgonine, THC, methamphetamine and morphine) were tested using the Multi4 card using control materials (Detectabuse Stat-Skreen; Biochemical Diagnostics, Edgewood, NY, USA). The concentrations (-50%, -25%, +25%, +50% and 3× cut-off values) of the control materials were confirmed by mass spectrometry. Concordance rates were calculated around cut-offs. All devices showed high overall agreement rates of >90% with a few exceptions: the DxLINK exhibited lower sensitivity for benzoylecgonine, methadone and nortriptyline (60% and 30%, 92% and 40%, and 96% and 60% sensitivity at +50% and +25% cut-off levels, respectively). The E-Z Cup exhibited lower sensitivity for oxazepam and nortriptyline (97% and 50%, and 97% and 40% sensitivity at +50% and +25% cut-off levels, respectively). We additionally evaluated test-band color by visual inspection using a standard color-scale card. When detailed color criteria for determination of positivity were applied for the E-Z Cup, using slightly less stringent criteria, oxazepam, buprenorphine, MDMA and nortriptyline showed increases in sensitivity from 70-80% to 90-100%, all with a specificity above 98%. Overall, all devices exhibited satisfactory performance at ±50% cut-off levels for commonly used drugs, with the exception of lower sensitivity for cocaine testing for DxLINK. Careful evaluation of devices and elaborate calibration of visual interpretation for determining positivity may help improve the performance of these devices.

    Topics: Amphetamine; Automation; Buprenorphine; China; Cocaine; Dronabinol; Gas Chromatography-Mass Spectrometry; Illicit Drugs; Immunoassay; Mass Spectrometry; Methadone; Methamphetamine; Morphine; Sensitivity and Specificity; Substance Abuse Detection

2017
Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.
    Scandinavian journal of clinical and laboratory investigation, 2015, Volume: 75, Issue:2

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders.. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine.. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred.. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

    Topics: Adolescent; Adult; Aged; Amphetamines; Breath Tests; Buprenorphine; Cocaine; Drug Users; Exhalation; Female; Humans; Male; Methadone; Methamphetamine; Middle Aged; Morphine; Morphine Derivatives; Patient Compliance; Substance Abuse Detection; Young Adult

2015
Estimation of illicit drugs consumption by wastewater analysis in Paris area (France).
    Forensic science international, 2010, Jul-15, Volume: 200, Issue:1-3

    Illicit drugs consumption is actually an important public health concern that needs to be well defined to be managed. A new method, expressed as sewage epidemiology has been proposed by Daughton and developed by Zuccato. This method involves estimating the consumption from the measurement of drug residues in sewage. Several studies have been carried out, leading to an assessment of drugs consumption in some European countries. This work, carried out in Paris area (France) brings new data to this assessment and allows a comparison of cocaine and MDMA consumptions with European estimations. Four wastewater treatment plants (WWTPs) have been retained for the study, taking into account biological treatment, volume capacity, geographic location and social environment. Cocaine and its major metabolite benzoylecgonine (BZE), amphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and buprenorphine were measured in raw water and WWTP effluent using HPLC-MS/MS after SPE extraction. Amphetamine was rarely detected. Cocaine and BZE were quantified at levels from 5 to 282 ng L(-1) and 15 to 849 ng L(-1), respectively. MDMA and buprenorphine concentrations remained under 20 ng L(-1). Cocaine consumption was estimated from cocaine or BZE concentrations measured in raw water and the results showed significant difference in drug taking during week or weekend. The estimated doses observed in this study are lower than those reported for others countries, especially Spain and Italy. MDMA consumption was estimated at lower levels than cocaine.

    Topics: Amphetamine; Buprenorphine; Chromatography, High Pressure Liquid; Cocaine; Humans; Illicit Drugs; Mass Spectrometry; N-Methyl-3,4-methylenedioxyamphetamine; Paris; Sewage

2010