betadex has been researched along with benzylparaben* in 2 studies
2 other study(ies) available for betadex and benzylparaben
Article | Year |
---|---|
Exploiting β-cyclodextrin in molecular imprinting for achieving recognition of benzylparaben in aqueous media.
The molecularly imprinted polymer (MIP) based on methacrylic acid functionalized β-cyclodextrin (MAA-β-CD) monomer was synthesized for the purpose of selective recognition of benzylparaben (BzP). The MAA-β-CD monomer was produced by bridging a methacrylic acid (MAA) and β-cyclodextrin (β-CD) using toluene-2,4-diisocyanate (TDI) by reacting the -OH group of MAA and one of the primary -OH groups of β-CD. This monomer comprised of triple interactions that included an inclusion complex, π-π interaction, and hydrogen bonding. To demonstrate β-CD performance in MIPs, two MIPs were prepared; molecularly imprinted polymer-methacrylic acid functionalized β-cyclodextrin, MIP(MAA-β-CD), and molecularly imprinted polymer-methacrylic acid, MIP(MAA); both prepared by a reversible addition fragmentation chain transfer polymerization (RAFT) in the bulk polymerization process. Both MIPs were characterized using the Fourier Transform Infrared Spectroscopy (FTIR), Field Emission Scanning Electron Microscopy (FESEM), and Brunauer-Emmett-Teller (BET). The presence of β-CD not only influenced the morphological structure, it also affected the specific surface area, average pore diameter, and total pore volume of the MIP. The rebinding of the imprinting effect was evaluated in binding experiments, which proved that the β-CD contributed significantly to the enhancement of the recognition affinity and selective adsorption of the MIP. Topics: Adsorption; beta-Cyclodextrins; Hydrogen Bonding; Microscopy, Electron, Scanning Transmission; Molecular Imprinting; Parabens; Polymers; Spectroscopy, Fourier Transform Infrared | 2015 |
Cloud point extraction of parabens using non-ionic surfactant with cylodextrin functionalized ionic liquid as a modifier.
A cloud point extraction (CPE) process using non-ionic surfactant (DC193C) to extract selected paraben compounds from water samples was investigated using reversed phase high performance liquid chromatography (RP-HPLC). The CPE process with the presence of β-cyclodextrin (βCD) functionalized ionic liquid as a modifier (CPE-DC193C-βCD-IL) is a new extraction technique that has been applied on the optimization of parameters, i.e., pH, βCD-IL concentration and phase volume ratio. This CPE-DC193C-βCD-IL method is facilitated at 30 °C, showing great losses of water content in the surfactant-rich phase, resulting in a high pre-concentration factor and high distribution coefficient. The developed method CPE-DC193C-βCD-IL did show enhanced properties compared to the CPE method without the modifier (CPE-DC193C). The developed method of CPE-DC193C-βCD-IL gives an excellent performance on the detection of parabens from water samples with the limit of detection falling in the range of 0.013-0.038 µg mL-1. Finally, the inclusion complex formation, hydrogen bonding, and π-π interaction between the βCD-IL, benzyl paraben (ArP), and DC 193C were proven using 1H NMR and 2D NOESY spectroscopy. Topics: beta-Cyclodextrins; Chromatography, High Pressure Liquid; Chromatography, Reverse-Phase; Hydrogen-Ion Concentration; Ionic Liquids; Parabens; Surface-Active Agents; Water | 2013 |