betadex has been researched along with 1-(9-fluorenyl)methyl-chloroformate* in 2 studies
2 other study(ies) available for betadex and 1-(9-fluorenyl)methyl-chloroformate
Article | Year |
---|---|
On-line sample preconcentration by sweeping and poly(ethylene oxide)-mediated stacking for simultaneous analysis of nine pairs of amino acid enantiomers in capillary electrophoresis.
This study proposes a sensitive method for the simultaneous separation and concentration of 9 pairs of amino acid enantiomers by combining poly(ethylene oxide) (PEO)-based stacking, β-cyclodextrin (β-CD)-mediated micellar electrokinetic chromatography (MEKC), and 9-fluoroenylmethyl chloroformate (FMOC) derivatization. The 9 pairs of FMOC-derivatized amino acid enantiomers were baseline separated using a discontinuous system, and the buffer vials contained a solution of 150 mM Tris-borate (TB), 12.5% (v/v) isopropanol (IPA), 0.5% (w/v) PEO, 35 mM sodium taurodeoxycholate (STDC), and 35 mM β-CD, and the capillary was filled with a solution of 1.5 M TB, 12.5% (v/v) IPA, 35 mM STDC, and 35 mM β-CD. Based on the difference in viscosity between the sample zone and PEO solution and because of the STDC sweeping, the discontinuous system effectively stacked 670 nL of the 9 pairs of FMOC-derivatized amino acid enantiomers without losing chiral resolution. Consequently, the limits of detection for the 9 pairs of FMOC-derivatized amino acid enantiomers were reduced to 40-60 nM. This method was successfully used to determine d-Tryptophan (Trp), l-Trp, d-Phenylalanine (Phe), l-Phe, d-Glutamic acid (Glu), and l-Glu in various types of beers. Topics: Amino Acids; beta-Cyclodextrins; Chromatography, Micellar Electrokinetic Capillary; Fluorenes; Naphthalenes; o-Phthalaldehyde; Online Systems; Polyethylene Glycols; Stereoisomerism; Taurodeoxycholic Acid | 2013 |
Chiral capillary electrophoretic separation of amino acids derivatized with 9-fluorenylmethylchloroformate using mixed chiral selectors of beta-cyclodextrin and sodium taurodeoxycholate.
Chiral separation of 19 pairs of amino acid (AA) enantiomers derivatized with 9-fluorenylmethylchloroformate (FMOC) was successfully conducted by capillary electrophoresis using the mixture of beta-CD and sodium taurodeoxycholate (STDC) as selectors. Resolution was considerably superior to that obtained by using either beta-CD or STDC alone. After a systematic inspection, a buffer composed of 150 mM borate and 18% v/v isopropanol at pH 8.0, dissolved with 30 mM beta-CD and 30 mM STDC, was adopted and able to generate baseline resolution (>1.50) for 17 pairs of FMOC-AA enantiomers and somewhat lower resolution for arginine (1.36) and alanine (1.18), respectively. Experimental data revealed that the addition of the second selector did not increase the mobility difference between a pair of enantiomers (Delta mu = mu(D) - mu(L) and the number of theoretical plates (N), but decreased the summed apparent mobility of a pair of enantiomers (Sigma mu = mu(D) - mu(L)), which was mainly due to the decrease of the electroosmotic flow. The variation of Sigma mu was thus the major reason responsible for the improvement of chiral resolution in this study. The result demonstrated that not only the intrinsic selectivity of the selectors was the basis of the chiral separation, but also the non-chiral effect of the selectors, the change of the electroosmotic flow, was an important factor in enhancing the enantioseparation resolution. This study could probably help to explain the reasons for resolution improvement in some dual selectors systems, which are not very clear at present. Topics: Amino Acids; beta-Cyclodextrins; Electrophoresis, Capillary; Fluorenes; Stereoisomerism; Taurodeoxycholic Acid | 2006 |