ascorbic-acid and methacrylic-acid

ascorbic-acid has been researched along with methacrylic-acid* in 4 studies

Other Studies

4 other study(ies) available for ascorbic-acid and methacrylic-acid

ArticleYear
Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study.
    Physics in medicine and biology, 2011, Nov-21, Volume: 56, Issue:22

    This study evaluates the dosimetric performance of the polymer gel dosimeter 'Methacrylic and Ascorbic acid in Gelatin, initiated by Copper' and its suitability for quality assurance and analysis of I-131-targeted radionuclide therapy dosimetry. Four batches of gel were manufactured in-house and sets of calibration vials and phantoms were created containing different concentrations of I-131-doped gel. Multiple dose measurements were made up to 700 h post preparation and compared to equivalent Monte Carlo simulations. In addition to uniformly filled phantoms the cross-dose distribution from a hot insert to a surrounding phantom was measured. In this example comparisons were made with both Monte Carlo and a clinical scintigraphic dosimetry method. Dose-response curves generated from the calibration data followed a sigmoid function. The gels appeared to be stable over many weeks of internal irradiation with a delay in gel response observed at 29 h post preparation. This was attributed to chemical inhibitors and slow reaction rates of long-chain radical species. For this reason, phantom measurements were only made after 190 h of irradiation. For uniformly filled phantoms of I-131 the accuracy of dose measurements agreed to within 10% when compared to Monte Carlo simulations. A radial cross-dose distribution measured using the gel dosimeter compared well to that calculated with Monte Carlo. Small inhomogeneities were observed in the dosimeter attributed to non-uniform mixing of monomer during preparation. However, they were not detrimental to this study where the quantitative accuracy and spatial resolution of polymer gel dosimetry were far superior to that calculated using scintigraphy. The difference between Monte Carlo and gel measurements was of the order of a few cGy, whilst with the scintigraphic method differences of up to 8 Gy were observed. A manipulation technique is also presented which allows 3D scintigraphic dosimetry measurements to be compared to polymer gel dosimetry measurements without generating misleading errors due to the limited spatial resolution.

    Topics: Ascorbic Acid; Calibration; Gels; Methacrylates; Monte Carlo Method; Phantoms, Imaging; Radiometry; Radiotherapy Dosage; Radiotherapy Planning, Computer-Assisted

2011
Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.
    Physics in medicine and biology, 2007, May-21, Volume: 52, Issue:10

    Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our studies of the effects of variations in the composition of the MAGIC gel performed in order to optimize its performance over the useful dose range of 0 to 20 Gy. A new formulation (termed 'MAGIC-2') is comprised of 87% water, 4% methacrylic acid, 9% gelatin, 17.38 x 10(-6) M Cu(2+) and a molar ratio of ascorbic acid to [Cu(2+)] of 1000:1. MAGIC-2 has a dose-response slope-to-intercept ratio that is 78% greater than the original formulation and other more favorable properties.

    Topics: Ascorbic Acid; Copper; Copper Sulfate; Gelatin; Hydroquinones; Methacrylates; Phantoms, Imaging; Polymers; Radiotherapy Dosage; Water

2007
Radiological properties of normoxic polymer gel dosimeters.
    Medical physics, 2005, Volume: 32, Issue:4

    The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m(-3)) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.

    Topics: Ascorbic Acid; Copper; Electrons; Methacrylates; Models, Statistical; Monte Carlo Method; Organophosphorus Compounds; Oxygen; Photons; Polymers; Probability; Radiometry; Water

2005
Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere.
    Physics in medicine and biology, 2001, Volume: 46, Issue:12

    Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere and which we have named MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper). To produce dosimeter gels, an aqueous solution of gelatin, open to the atmosphere, is mixed with methacrylic acid, copper(II) ions, ascorbic acid and hydroquinone. It is believed that the copper(II) and ascorbic acid form a complex with oxygen which (with radiolysis of water) serves as a free radical source for the initiation of the polymerization of methacrylic acid. At room air the water proton spin relaxation rate R2 in MAGIC gels is proportional to absorbed dose though the precise relationship depends on the composition of the gel and the initiating complex. For example, in the range 0-30 Gy the slope of the response of R2 versus dose at 20 MHz was 0.300, 0.519 and 0.681 s(-1) Gy(-1), respectively, when the concentration of MAA was 3, 6 and 9%. The slopes increased to 0.310, 0.567 and 0.868 s(-1) Gy(-1) at 85 MHz. An important determinant of the sensitivity to detect small dose changes is shown to be the slope-to-intercept ratio of the dose-response curve. These varied from 0.08 to 0.17, comparable to hypoxic gels described earlier. MAGIC gels can be manufactured and used much more easily than the previous formulations and can be imaged by magnetic resonance imaging or optical scanning, and thus they will likely be of considerable interest to radiation physicists.

    Topics: Ascorbic Acid; Copper; Dose-Response Relationship, Radiation; Gelatin; Gels; Hydroquinones; Ions; Magnetic Resonance Imaging; Magnetic Resonance Spectroscopy; Methacrylates; Phantoms, Imaging; Polymers; Pressure; Protons; Radiometry

2001