acetaminophen and 8-aminoquinoline

acetaminophen has been researched along with 8-aminoquinoline in 5 studies

Research

Studies (5)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's0 (0.00)18.2507
2000's2 (40.00)29.6817
2010's3 (60.00)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Kertesz, V; Van Berkel, GJ1
Abu-Rabie, P; Spooner, N2
Denniff, P; Spooner, N1
Abu-Rabie, P; Brynjolffssen, J; Denniff, P; Galluzzo, P; Sanders, G; Spooner, N1

Other Studies

5 other study(ies) available for acetaminophen and 8-aminoquinoline

ArticleYear
Application of a liquid extraction based sealing surface sampling probe for mass spectrometric analysis of dried blood spots and mouse whole-body thin tissue sections.
    Analytical chemistry, 2009, Nov-01, Volume: 81, Issue:21

    Topics: Acetaminophen; Aminoquinolines; Analgesics, Non-Narcotic; Animals; Blood Specimen Collection; Chromatography, High Pressure Liquid; Frozen Sections; Male; Mass Spectrometry; Mice; Propranolol; Tissue Distribution

2009
Direct quantitative bioanalysis of drugs in dried blood spot samples using a thin-layer chromatography mass spectrometer interface.
    Analytical chemistry, 2009, Dec-15, Volume: 81, Issue:24

    Topics: Acetaminophen; Aminoquinolines; Benzethonium; Blood Chemical Analysis; Chromatography, High Pressure Liquid; Humans; Ibuprofen; Mass Spectrometry; Phthalic Acids; Proguanil; Sensitivity and Specificity; Simvastatin

2009
The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs.
    Bioanalysis, 2010, Volume: 2, Issue:8

    Topics: Acetaminophen; Aminoquinolines; Artifacts; Bias; Blood Chemical Analysis; Blood Specimen Collection; Cellulose; Desiccation; Female; Hematocrit; Humans; Male; Paper; Pharmaceutical Preparations; Quality Control

2010
Method of applying internal standard to dried matrix spot samples for use in quantitative bioanalysis.
    Analytical chemistry, 2011, Nov-15, Volume: 83, Issue:22

    Topics: Acetaminophen; Aminoquinolines; Chromatography, High Pressure Liquid; Dried Blood Spot Testing; Humans; Mass Spectrometry; Methanol; Sensitivity and Specificity

2011
Dried matrix spot direct analysis: evaluating the robustness of a direct elution technique for use in quantitative bioanalysis.
    Bioanalysis, 2011, Volume: 3, Issue:24

    Topics: Acetaminophen; Aminoquinolines; Automation; Chromatography, High Pressure Liquid; Dried Blood Spot Testing; Humans; Pharmaceutical Preparations; Reproducibility of Results; Solvents; Tandem Mass Spectrometry

2011