Page last updated: 2024-09-03

7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate and cysteine

7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate has been researched along with cysteine in 7 studies

Compound Research Comparison

Studies
(7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate)
Trials
(7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate)
Recent Studies (post-2010)
(7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate)
Studies
(cysteine)
Trials
(cysteine)
Recent Studies (post-2010) (cysteine)
310240,13241811,457

Research

Studies (7)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's4 (57.14)18.2507
2000's2 (28.57)29.6817
2010's1 (14.29)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Kalafatis, M; Kung, C; Mann, KG; Silveira, JR; Xue, J1
Crooks, R; Dudman, NP; Guo, XW; Silberberg, JS; Xie, L1
Deufel, T; Feussner, A; Rolinski, B; Roscher, AA; Weiss, N; Wolfram, G1
Bosoni, T; Montalbetti, L; Moratti, R; Rizzo, V; Scoglio, E; Valli, M1
Arcelloni, C; Fermo, I; Paroni, R1
Aoyagi, K; Ichinose, S; Ikeda, R; Maeda, M; Maeda, T; Nakamura, M; Nakashima, K; Nakazato, M; Ohba, Y; Takamura, N; Wada, M1
Chang, SJ; Kato, H; Nakazawa, K; Ogawa, S; Otani, L; Umehara, S; Yoshimura, E; Zhao, Z1

Other Studies

7 other study(ies) available for 7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate and cysteine

ArticleYear
Determination of the disulfide bridges in factor Va heavy chain.
    Biochemistry, 1994, Nov-08, Volume: 33, Issue:44

    Topics: Amino Acid Sequence; Animals; Cattle; Chromatography, High Pressure Liquid; Cyanogen Bromide; Cysteine; Disulfides; Factor Va; Fibrinolysin; Fluorescent Dyes; Fluorobenzenes; Fluorometry; Iodine Radioisotopes; Molecular Sequence Data; Molecular Weight; Protein Conformation; Sequence Homology, Amino Acid; Serine Endopeptidases; Staphylococcus aureus; Sulfhydryl Reagents; Trypsin

1994
Assay of plasma homocysteine: light sensitivity of the fluorescent 7-benzo-2-oxa-1, 3-diazole-4-sulfonic acid derivative, and use of appropriate calibrators.
    Clinical chemistry, 1996, Volume: 42, Issue:12

    Topics: Calibration; Chromatography, High Pressure Liquid; Cysteine; Drug Stability; Fluorescent Dyes; Fluorobenzenes; Homocysteine; Homocystine; Humans; Light; Quality Control; Reproducibility of Results

1996
Determination of total homocysteine in human plasma by isocratic high-performance liquid chromatography.
    European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies, 1997, Volume: 35, Issue:9

    Topics: Chromatography, High Pressure Liquid; Cysteine; Fluorescent Dyes; Fluorobenzenes; Homocysteine; Humans; Male; Oxidation-Reduction; Phosphines; Regression Analysis; Reproducibility of Results; Sensitivity and Specificity

1997
Study of factors affecting the determination of total plasma 7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate (SBD)-thiol derivatives by liquid chromatography.
    Journal of chromatography. B, Biomedical sciences and applications, 1998, Mar-20, Volume: 706, Issue:2

    Topics: Adult; Borohydrides; Chromatography, High Pressure Liquid; Cysteine; Dipeptides; Dithiothreitol; Female; Fluorescent Dyes; Fluorobenzenes; Homocysteine; Humans; Hydrogen-Ion Concentration; Male; Middle Aged; Phosphines; Reducing Agents; Reproducibility of Results; Sensitivity and Specificity; Spectrometry, Fluorescence; Sulfhydryl Reagents

1998
High-performance liquid chromatographic method to quantify total cysteine excretion in urine.
    Analytical biochemistry, 2002, Aug-01, Volume: 307, Issue:1

    Topics: Adolescent; Adult; Aged; Amino Acids, Diamino; Borohydrides; Calibration; Case-Control Studies; Chromatography, High Pressure Liquid; Cystamine; Cysteine; Cystinuria; Disulfides; Female; Fluorescent Dyes; Fluorobenzenes; Humans; Male; Middle Aged; o-Phthalaldehyde; Oxidation-Reduction; Reference Standards; Sensitivity and Specificity; Sulfhydryl Reagents

2002
A validated HPLC-fluorescence method with a semi-micro column for routine determination of homocysteine, cysteine and cysteamine, and the relation between the thiol derivatives in normal human plasma.
    Biomedical chromatography : BMC, 2009, Volume: 23, Issue:9

    Topics: Chromatography, High Pressure Liquid; Cysteamine; Cysteine; Fluorobenzenes; Homocysteine; Humans; Reproducibility of Results; Sensitivity and Specificity; Spectrometry, Fluorescence

2009
Optimized method for determining free L-cysteine in rat plasma by high-performance liquid chromatography with the 4-aminosulfonyl-7-fluoro-2,1,3-benzoxadiazole conversion reagent.
    Bioscience, biotechnology, and biochemistry, 2011, Volume: 75, Issue:11

    Topics: Animals; Chromatography, High Pressure Liquid; Cysteine; Cystine; Fluorescent Dyes; Fluorobenzenes; Male; Oxadiazoles; Rats; Rats, Wistar

2011