Page last updated: 2024-09-03

4-(n,n-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole and oxadiazoles

4-(n,n-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole has been researched along with oxadiazoles in 7 studies

Compound Research Comparison

Studies
(4-(n,n-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole)
Trials
(4-(n,n-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole)
Recent Studies (post-2010)
(4-(n,n-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole)
Studies
(oxadiazoles)
Trials
(oxadiazoles)
Recent Studies (post-2010) (oxadiazoles)
8026,0572572,359

Research

Studies (7)

TimeframeStudies, this research(%)All Research%
pre-19900 (0.00)18.7374
1990's3 (42.86)18.2507
2000's2 (28.57)29.6817
2010's2 (28.57)24.3611
2020's0 (0.00)2.80

Authors

AuthorsStudies
Hasegawa, H; Nagata, O; Takahara, E; Yamada, T1
Fukushima, T; Ichihara, H; Imai, K1
Adachi, S; Al-Kindy, S; Fukushima, T; Ichihara, H; Imai, K1
Fukushima, T; Hirayama, K; Imai, K; Kubota, K; Miyano, H; Santa, T; Yuji, R1
Fukushima, T; Funatsu, T; Hirayama, K; Imai, K; Miyano, H; Santa, T; Tsukamoto, Y; Yoshida, H1
Fujioka, T; Goto, K; Inoue, K; Ishii, Y; Min, JZ; Nakano, T; Todoroki, K; Tomita, R; Toyo'oka, T1
Fukuuchi, T; Iijima, R; Kaneko, K; Kawasaki, A; Mawatari, KI; Nakagomi, K; Satoh, M; Yamaoka, N; Yasuda, M; Yui, S1

Other Studies

7 other study(ies) available for 4-(n,n-dimethylaminosulphonyl)-7-(1-piperazinyl)-2,1,3-benzoxadiazole and oxadiazoles

ArticleYear
Sensitive analytical method for the novel H1-receptor antagonist HSR-609 in human plasma and urine by high-performance liquid chromatography with pre-column fluorescent derivatization.
    Journal of chromatography. B, Biomedical applications, 1996, Dec-13, Volume: 687, Issue:2

    Topics: Benzoxepins; Chromatography, High Pressure Liquid; Fluorescence; Histamine H1 Antagonists; Humans; Male; Oxadiazoles; Piperazines; Pyridines; Reproducibility of Results; Sensitivity and Specificity; Sulfonamides

1996
Enantiomeric determination of D- and L-lactate in rat serum using high-performance liquid chromatography with a cellulose-type chiral stationary phase and fluorescence detection.
    Analytical biochemistry, 1999, May-01, Volume: 269, Issue:2

    Topics: Acetylation; Animals; Blood Chemical Analysis; Cellulose; Chromatography, High Pressure Liquid; Fasting; Lactic Acid; Male; Oxadiazoles; Piperazines; Rats; Rats, Sprague-Dawley; Reproducibility of Results; Spectrometry, Fluorescence; Stereoisomerism; Sulfonamides

1999
Fluorimetric determination of D- and L-lactate derivatized with 4-(N, N-dimethylaminosulfonyl)-7-piperazino-2,1,3-benzoxadiazole (DBD-PZ) by high-performance liquid chromatography.
    Biomedical chromatography : BMC, 1999, Volume: 13, Issue:6

    Topics: Calibration; Chromatography, High Pressure Liquid; Fluorometry; Lactates; Oxadiazoles; Piperazines; Stereoisomerism; Sulfonamides; Time Factors; Wine

1999
Development of an HPLC-fluorescence determination method for carboxylic acids related to the tricarboxylic acid cycle as a metabolome tool.
    Biomedical chromatography : BMC, 2005, Volume: 19, Issue:10

    Topics: Animals; Carboxylic Acids; Chromatography, High Pressure Liquid; Citric Acid Cycle; Fluorescent Dyes; Male; Oxadiazoles; Piperazines; Rats; Rats, Sprague-Dawley; Spectrometry, Fluorescence; Spectrometry, Mass, Electrospray Ionization; Sulfonamides

2005
A further study on the combined use of internal standard and isotope-labeled derivatization reagent for expansion of linear dynamic ranges in liquid chromatography-electrospray mass spectrometry.
    Biomedical chromatography : BMC, 2006, Volume: 20, Issue:10

    Topics: Chromatography, Liquid; Fatty Acids; Isotope Labeling; Molecular Structure; Oxadiazoles; Piperazines; Reference Standards; Reproducibility of Results; Spectrometry, Mass, Electrospray Ionization; Sulfonamides

2006
Automatic analyzer for highly polar carboxylic acids based on fluorescence derivatization-liquid chromatography.
    Biomedical chromatography : BMC, 2015, Volume: 29, Issue:3

    Topics: Automation; Beverages; Carboxylic Acids; Chromatography, High Pressure Liquid; Chromatography, Liquid; Culture Media; Fluorescent Dyes; Fruit; Humans; Limit of Detection; Morpholines; Oxadiazoles; Piperazines; Reproducibility of Results; Signal-To-Noise Ratio; Sulfonamides; Tandem Mass Spectrometry; Tumor Cells, Cultured; Wine

2015
Sensitive Analysis of Sialic Acid and Related Compound by Hydrophilic Interaction Liquid Chromatography Using Fluorescence Detection after Derivatization with DBD-PZ.
    Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2018, Volume: 34, Issue:7

    Topics: Chromatography, Liquid; Fluorescence; Hydrophobic and Hydrophilic Interactions; Molecular Structure; Oxadiazoles; Piperazines; Sialic Acids; Sulfonamides

2018